IIIC Conductive dust Intrinsic safety ia Ga 0,1,2 IEC 60079-11 Limit the energy of sparks and surface temperatures
Intrinsic safety ib Gb 1,2 IEC 60079-11
SIRA ATEX CERTIFICATE NUMBER Intrinsic safety ic Gc 2 IEC 60079-11
Type n (energy limitation) nL Gc 2 IEC 60079-15
TEMPERATURE CLASS (GROUP II)
SIRA 09 ATEX 1234 Pressurised (up to 2007) p Gb 1,2 IEC 60079-2 Keep the flammable gas out
Maximum surface T Class Pressurised px Gb 1,2 IEC 60079-2
temperature Pressurised py Gb 1,2 IEC 60079-2
Pressurised pz Gc 2 IEC 60079-2
450C T1 Serial number Type n (sealing & hermetic sealing) nC Gc 2 IEC 60079-15
Type n (restricted breathing) nR Gc 2 IEC 60079-15
300C T2 Reference to ATEX 95 directive Type n (simple pressurised) nZ Gc 2 IEC 60079-15
200C T3
Year of certification Encapsulation ma Ga 0,1,2 IEC 60079-18
135C T4 Encapsulation mb Gb 1,2 IEC 60079-18
100C T5
Name of notified body performing EC-type examination Oil immersion o Gb 1,2 IEC 60079-6
85C T6
Suffixes:
Dust Protection Symbol Typical
IEC EPL
Typical
Zone(s)
IEC Standard
(status at August 2009)
Basic concept of protection
N.B. For Group I applications, apparatus has rigid 150C (Electrical)
}{
(coal dust) and 450C (methane) limits rather than T classes. U component certification X special conditions for safe use apply
Enclosure t 20, 21, 22 IEC 61241-1 Standard protection for dusts, rugged tight enclosure
Intrinsic safety i Da 21, 22 IEC 61241-11 Similar to t, but with some relaxations if circuit inside
Db is intrinsically safe
TYPICAL EQUIPMENT MARKING Dc
(ELECTRICAL EQUIPMENT)
IECEx licenced mark (IECEx only) Apparatus Group and T Class Encapsulation m 22 IEC 61241-18 Protection by encapsulation of incendive parts
UK Offices
Assessment
NORTH AMERICAN / EUROPEAN AREA NORTH AMERICAN / EUROPEAN Stirling +44 (0)1786 449444
CLASSIFICATION EQUIVALENTS - DUST EQUIPMENT GROUPING EQUIVALENTS - DUST Aberdeen +44 (0)1224 874554
Combustible Combustible Combustible EU (60079-0) IEC (61241-0) US (NEC 500)
Hull +44 (0)1482 213626 Knowledge Certificate If sufficient and relevant
Dust Present
Continuously
Dust Present
Intermittently
Dust Present
Abnormally
Typical material IEC (60079-0) US (NEC 506) EU (61241-0) CA (CEC Section 18) Lowestoft +44 (0)1502 539991
Metal dusts IIIC N/A D Class II,
IEC / EU Zone 20 Zone 21 Zone 22 Group E www.drondickson.com COMPETENCE CERTIFICATE
(Scope)
US NEC 506 Zone 20 Zone 21 Zone 22 Carbonaceous dusts IIIB D D Class II,
US NEC 500 Division 1 Division 2 Group F
Non-conductive dusts IIIB D D Registration
CA CEC Section 18 Division 1 Division 2 Class II,
Group G
US area classification per ANSI / NFPA 70 National Electrical Code (NEC) Article 500 or 506
CA area classification per CSA C22.1 Canadian Electrical Code (CEC) Section 18 Fibres and flyings IIIA D D Class III Periodic Review
EU area classification per EN 61241-10 IEC area classification per IEC 61241-10
0327 011
For more information, visit the sira website: www.siracertification.com email: info@siracertification.com tel: +44 (0) 1244 670 900 August 2009
Accredited certification and EU Notified Body activities are undertaken by Sira Certification Service. Sira has provided the technical information for this publication to DronDickson. The IP and copyright remains with Sira. Sira's association with this publication does not extend to endorsement of DronDicksons products with respect to performance or fitness for purpose. a CSA International company