You are on page 1of 2

Product Data

HEMPADUR 35900

35900: BASE 35909: CURING AGENT 95900


Description: HEMPADUR 35900 is a two-component solventfree high build amine cured phenolic epoxy (novolac)
coating with excellent adhesion and resistance to crude oil up to 93C/ 200F.
Recommended use: As an interior lining in tanks, pipelines etc. for crude oil, water and produced water.
HEMPADUR 35900 may be reinforced with fibre glass mats as a solution for the repair of pitted tank
bottoms. For this specific use a clear version of HEMPADUR 35900 is available. (Please refer to the
specific Application Instruction 3590000000 Fibre Mats)
Service temperature: Maximum, dry exposure only: 160C/320F
In water (no temperature gradient): 93C/200F
Availability: Part of Group Assortment. Local availability subject to confirmation.
PHYSICAL CONSTANTS:
Shade nos/Colours: 20320/ Cream
Finish: Semi-gloss
Volume solids, %: 100
Theoretical spreading rate: 2.5 m2/l [100.2 sq.ft./US gallon] - 400 micron/16 mils
Flash point: 82 C [179.6 F]
Specific gravity: 1.4 kg/litre [11.3 lbs/US gallon]
Dry to touch: 11 hour(s) , 20C/68F
Fully cured: 7 day(s) , 20C/68F (See separate APPLICATION
INSTRUCTIONS)
VOC content: 24 g/l [0.2 lbs/US gallon]
Shelf life: 1 year for BASE and 3 years (25C/77F) for CURING AGENT from time of production.
- The physical constants stated are nominal data according to the HEMPEL Group's approved formulas.

APPLICATION DETAILS:
Version, mixed product: 35900
Mixing ratio: BASE 35909: CURING AGENT 95900
3:1 by volume
4.75:1 by weight
Application method: Airless spray / Brush (touch up)
Thinner (max.vol.): Do not dilute.
Pot life: 1 hour(s) 20C/68F (See separate APPLICATION INSTRUCTIONS)
Nozzle orifice: 0.019 - 0.025 "
Nozzle pressure: 250 bar [3625 psi] (minimum)

(Airless spray data are indicative and subject to adjustment)


Cleaning of tools: HEMPEL'S TOOL CLEANER 99610
Indicated film thickness, dry: 500 micron [20 mils]
Indicated film thickness, wet: 500 micron [20 mils]
Overcoat interval, min: see REMARKS overleaf
Overcoat interval, max: see REMARKS overleaf
-
Safety: Handle with care. Before and during use, observe all safety labels on packaging and paint containers,
consult HEMPEL Safety Data Sheets and follow all local or national safety regulations.

Date of issue: June 2016 Page: 1/2


Product Data
HEMPADUR 35900

SURFACE PREPARATION: New steel: Remove oil and grease etc. thoroughly with suitable detergent. Remove salts and other
contaminants by high pressure fresh water cleaning. Abrasive blasting to near white metal Sa 2 (ISO
8501-1:2007) with a surface profile corresponding to Rugotest No. 3, BN10a, Keane-Tator Comparator
3.0 G/S, or ISO Comparator Medium (G).
Maintenance: Remove oil and grease etc. thoroughly with suitable detergent. Remove salts and other
contaminants by high pressure fresh water cleaning. Other degrees of cleaning including wet methods
like ultra-high-pressure-water-jetting (UHPWJ) and blasting with mixtures of grit and water may be
relevant according to Hempel-specification. Remove water, any residual blasting material and other
debris.
(See separate APPLICATION INSTRUCTIONS)
APPLICATION CONDITIONS: Use only where application and curing can proceed at temperatures above: 10C/50F. The
temperature of the paint itself should be above: 20C/68F. Apply only on a dry and clean surface with
a temperature above the dew point to avoid condensation.
PRECEDING COAT: None, or as per specification.
SUBSEQUENT COAT: None.
REMARKS:

Weathering/service temperatures: The natural tendency of epoxy coatings to chalk in outdoor exposure and to become more sensitive to
mechanical damage and chemical exposure at elevated temperatures is also reflected in this product.
Induction time: To facilitate proper application properties it is recommended to allow the thoroughly mixed BASE and
CURING AGENT to prereact before application.
Application(s): Do not put tanks into service until the paint system is completely cured.

Holding primer: For service temperature up to 60oC/140oF HEMPADUR 15590 or HEMPADUR 85671
can be used as holding primer.
For service temperature above 60oC/140oF only HEMPADUR 85671 can be used as holding primer.
Maximum recoating interval between HEMPADUR 15590 and HEMPADUR 35900 is 30 days at 20oC/68
o
F.
Maximum recoating interval between HEMPADUR 85671 and HEMPADUR 35900 is 21 days at 20oC/68
o
F.
Film thicknesses/thinning: May be specified in another film thickness than indicated depending on purpose and area of use. This
will alter spreading rate and may influence drying time and overcoating interval. Normal range dry is:
250-500 micron/10-20mils
Overcoating: Overcoating intervals related to later conditions of exposure: If the maximum overcoating interval is
exceeded, roughening of the surface is necessary to ensure intercoat adhesion.
Before overcoating after exposure in contaminated environment, clean the surface thoroughly with high
pressure fresh water hosing and allow drying.

A specification supersedes any guideline overcoat intervals indicated in the table.


Environment Immersion
Surface temperature: 10C (50F) 20C (68F) 30C (86F)
Min Max Min Max Min Max
35900 3d 90 d* 1d 60 d* 12 h 30 d*
NR = Not Recommended, Ext. = Extended, m = minute(s), h = hour(s), d = day(s)

Overcoating note: *Depending on actual local conditions, the long maximum overcoating intervals may vary.
Contact HEMPEL for more information. A completely clean surface is mandatory to ensure intercoat
adhesion, especially at long overcoating intervals. Any dirt, oil, grease, and other foreign matter must
be removed with suitable detergent followed by (high pressure) fresh water cleaning. Salts to be
removed by fresh water hosing.
Note: HEMPADUR 35900 For professional use only.
ISSUED BY: HEMPEL A/S 3590020320

This Product Data Sheet supersedes those previously issued.


For explanations, definitions and scope, see Explanatory Notes available on www.hempel.com. Data, specifications, directions and recommendations given in this data sheet
represent only test results or experience obtained under controlled or specially defined circumstances. Their accuracy, completeness or appropriateness under the actual conditions
of any intended use of the Products herein must be determined exclusively by the Buyer and/or User.
The Products are supplied and all technical assistance is given subject to HEMPEL's GENERAL CONDITIONS OF SALES, DELIVERY AND SERVICE, unless otherwise expressly agreed
in writing. The Manufacturer and Seller disclaim, and Buyer and/or User waive all claims involving, any liability, including but not limited to negligence, except as expressed in said
GENERAL CONDITIONS for all results, injury or direct or consequential losses or damages arising from the use of the Products as recommended above, on the overleaf or otherwise.
Product data are subject to change without notice and become void five years from the date of issue.

Date of issue: June 2016 Page: 2/2

You might also like