PUMP

PROCESS DATA SHEET

REV. PROJECT N
DATE UNIT
BY CLIENT
CHECKED LOCATION
APPROVED DOC N
PAGE
REV

1 ITEM NUMBER P-1-1/P-1-2


2 SERVICE Booster Pump
3 TYPE OF PUMP Low Shear Pump ( API 610/API 676 VTA)
4 N OF PUMPS 2
5 IN OPERATION 1
6 SPARE 1
7 OPERATION (Continuous / Intermittent) CONTINUOUS
8 MOTOR ELECTRICAL
9 DRIVER TURBINE -
10 OTHERS -
11 PUMP LOCATION (Indoors / Outdoors) Outdoors
12 DESIGN STANDARD API 610/API 676 SEAL TYPE VTA
13 LIQUID PUMPED Produced Water
14 OPERATING CASE Normal (Note 3) Max (Note 4)
15 PUMPING TEMPERATURE (T) C 35-65 35-65
16 MAXIMUM OPERATING TEMPERATURE C 110 110
17 VISCOSITY @ 50 o C cSt 0.55-0.65 0.55-0.65
18 VAPOR PRESSURE @ T bar a - -
19 DENSITY @ 20 o C kg/m3 1016-1017 1016-1017
20 MAXIMUM DENSITY kg/m3 1017 1017
21 CORROSION DUE TO NO NO
22 TOXICITY DUE TO NO NO
23 EROSION NO NO
24 SOLIDS IN SUSPENSION NO NO
25 NORMAL CAPACITY m3/day 5500 8000
26 DESIGN CAPACITY m3/day 5500 8000
27 DISCHARGE PRESSURE @ Normal Cap. / Design Cap. bar g 2.5-5.5 2.5-5.5
28 SUCTION PRESSURE @ Normal Cap. / Design Cap. bar g 0.5 - 0.7 0.5 - 0.7
29 DIFFERENTIAL PRESSURE @ Normal Cap. / Design Cap. bar
30 DIFFERENTIAL HEAD @ Normal Cap. / Design Cap. m VTA VTA VTA VTA
31 AVAILABLE NPSH @ Normal Cap. / Design Cap. m 9.3 VTA 9.3 VTA
32 MAXIMUM SUCTION PRESSURE bar g 0.7 0.7
33 SHUT-OFF PRESSURE bar g VTA VTA
34 MINIMUM CIRCULATION FLOW (MCF) m3/h -
35 HYDRAULIC POWER @ Design Flow kW VTA
36 MECHANICAL POWER @ Design Flow kW VTA
37 CASING Duplex SS
38 MATERIAL OF CONSTRUCTION IMPELLER Duplex SS
39 SHAFT Duplex SS
40 Suction connection 8'', 150 # RF
41 Discharge connection 6'', 150 # RF
42 VTA : Vendor to advise
43 NOTES
44 1. Vendor to advise type of the low shear pump used for Booster Pump
45 2. The Booster Pump shell be designed, fabricated, inspected, testes, preserved, packed and delivered in accordance with corresponding API standard ( API 675/API 610 )
46 3. 1 duty and 1 stand by with capacity 5500 m3/day
47 4. 2 pumps in duty , Total capacity 8000 m3/d
48 5. NPSH (NPSHa-NPSHr) is greater than or equal to 1 m
49 6. VFD is required for each Booster pump motors control
50 7. Each pump and driver shall be capable of 20 % excess capacity.
51 8. Pump shall be suitable for offshore services
52