You are on page 1of 8

Gas & Steam Turbine Directory

Gas Turbine Technical Data


GROSS OUTPUT NET OUTPUT (CC) NET OUTPUT (SC) HEAT RATE GROSS EFFICIENCY NET EFFICIENCY
MANUFACTURER MODEL FREQUENCY (HZ)
(MW) MW MW (KJ/KWH) % (CC) %

GT26 326 8933 40.3 50


GT24 230.7 9000 40 60
Alstom
GT13E2 202.7 9474 38 50
Power
GT11N2 113.6 10 811 33.3 50
GT11N2 53.9 7200 50 60

AE64.3A 75.2 111.7 - 10 028 35.90 53.75 50/60


AE94.21 170 258.4 - 10 366 34.73 53.13 50
Anslado Energia
AE94.2K 170 case by case - 9863 36.50 case by case 50
AE94.3A 294.2 430.0 - 9068 39.70 58.65 50

KG2-3E 1.895 16.7


VECTRA 30G 22.767 9428 36.2 60
DR-61G 23.394 9280 36.8 60
VECTRA 40G 30.460 8780 38.9 60
Dresser-Rand DR-61GP 30.742 8821 38.7 60
VECTRA 40G4 33.209 8737 39.1 60
DR-61G4 33.175 8811 38.7 60
DR-63G PC 43.738 8166 41.8 60
DR-63G PG 50.447 8213 41.6 60

106B 43 64.3 6820 50 50/60


106C 44.8 67.2 6281 54.3 50/60
106FA 77.1 118.4 6119 55 50/60
109E 124.3 193.2 6570 51.9 50
GE Energy
109FA 254.1 390.8 5998 56.9 50
109FB 284 437.1 5829 58.6 50
107EA 83.5 130.2 6800 50.2 60
107FA 183.2 274 5948 57.4 60

H-15 (natural gas) 16.9 10 500 34.3 50/60


HitachiPower
H-25 (distillate oil) 31 10 610 33.9 50/60
Systems
H-25 (natural gas) 32 10 350 34.8 50/60

GPB180D 18.4 10 690 34.2 50


GPB80D 7.4 11 010 33.1 50
Kawasaki Gas
Turbine Europe GPB60D 5.4 12 460 29.3 50
GmbH
GPB17D 1.7 13 870 26.9 50
GPB06 0.6 18 556 19.4 50

FT8 25.5 9440 38.1

MAN Diesel & TM1304-10N2 10.5 10.08 11 840 30.4 50/60


Turbo SE TM1304-12N2 12.5 12 11 320 31.8 50/60
GT6 6.9 6.63 10 590 34 50/60

M501DA 113.95 167.4 113.95 10 320 34.9 51.4 60


M501F3 185.4 285.1 185.4 9740 37 57.1 60
M501G1 267.5 398.9 267.5 9211 39.1 58.4 60
Mitsubishi Heavy M501GAC 272 404 272 9074 39.7 59.2 60
Industries3
M501J 327 470 327 8783 41 61.5 60
M701DA 144.09 212.5 144.09 10 350 34.8 51.4 50
M701F4 324.3 477.9 324.3 9027 39.9 60 50
M701F5 359 525 359 9000 40 61 50

34 www.peimagazine.com April 2012 - PEi

1204PEI_34 34 4/16/12 12:15 PM


Gas & Steam Turbine Directory

SHAFT SPEED TURBINE INLET EXHAUST MASS EXHAUST NOx EMISSIONS START-UP TIME DIMENSIONS
PRESSURE RATIO WEIGHT (TONNES)
(RPM) TEMPERATURE (C) FLOW (KG/S) TEMPERATURE (C) (PPMV) (MINUTES) LxWxH (METRES)

3000 35:1 692 603 406 12 x 4.9 x 5.5


3600 35.4:1 505 597 230 10.7 x 4 x 4.6
3000 18.2:1 624 501 350 11 x 5.4 x 5.5
3610 16:1 400 525 190 9.4 x 5.5 x 10.1
3600 15.9:1 692 597 190 9.4 x 5.5 x 10.1

3000/3600 16.7 - 213 574 <25 case by case 100 12 x 4 x 5


3000 11.5 - 535 552 <25 case by case 280 15 x 14 x 9
3000 12.0 - 540 545 case by case case by case 280 15 x 14 x 9
3000 18.2 - 702 580 <15 case by case 360 14 x 7 x 9

18 800 4.7 549


6200 17.9 67.9 547
3600 18.2 69.5 533
6200 22.4 86.3 526
3600 22.5 87.2 515
6200 23.6 90 541
3600 23 91.5 526
3600 27.9 126.6 457
3743 29.7 139.7 486

5163 12.6 141 15 case by case 317.5 37 x 7 x 10


7100 19.6 122 15 case by case 351.5 25 x 8 x 12
5231 15.6 212 15 case by case 362 28 x 20 x 10
3000 12.6 643 15 case by case 861 35 x 23 x 12
3000 16.6 655 15 case by case 1088 34 x 7 x 14
3000 18 299 15 case by case 1088 34 x 7 x 14
3600 12.7 436 9 case by case 485 40 x 21 x 9
3600 16.1 418 9 case by case 744 54 x 22 x 9

9710 52.9 564


7280 96.6 561
7280 96.6 561

9420 19:1 59.81 542 15 10 ca.190 20 x 5.7 x 10


13 790 16:1 27.28 509 9.9 10 ca.70 14.5 x 3.5 x 6.8
14 000 13:1 21.75 542 36 10 ca.70 14.5 x 3.5 x 6.8
22 000 10:5 8 521 15 6 ca.25 8.4 x 2.75 x 6.3
31 000 8.5:1 5.05 474 36 6 ca.22 6.35 x 2.2 x 5.8

5500 85.1 458


9000 10 - 46.5 490 77 16 x 3 x 5
9000 11 - 49.1 515 77 16 x 4 x 6
12 000 15 - 28.1 451

3600 14 - 354 543 25 30 145 12 x 6 x 4


3600 16 - 468 613 15 30 195 14 x 5 x 5
3600 20 - 612 601 15 30 333 15 x 6 x 6
3600 20 - 612 614 15 30 270 15 x 6 x 6
3600 23 - 620 636 25 30 317 15 x 6 x 6
3000 14 - 453 542 25 30 200 13 x 5 x 5
3000 18 - 730 592 15 30 420 17 x 6 x 6
3000 21 - 730 611 15 30 480 17 x 6 x 6

PEi - April 2012 www.peimagazine.com 35

1204PEI_35 35 4/16/12 12:15 PM


Gas & Steam Turbine Directory

GROSS OUTPUT NET OUTPUT (CC) NET OUTPUT (SC) HEAT RATE GROSS EFFICIENCY NET EFFICIENCY
MANUFACTURER MODEL FREQUENCY (HZ)
(MW) MW MW (KJ/KWH) % (CC) %

Mitsubishi Heavy M701G2 334 498 334 9110 39.5 59.3 50


Industries3 M701J 470 680 470 8783 41 61.7 50

NPO Saturn JSC GTD-110 110 165; 325 110 118.8 (Gcal) 36.5 52 50

OP16-3A 1.91 13 382 26.9 50/60


OPRA Turbines
OP16-3B (DLE) 1.91 13 382 26.9 50/60

OGT 2500 2.85 11 975 28.5

Orenda Aerospace OGT 6000 6.7 10 835 31.5


Corporation
OGT 15000 17.5 10 835 35.5
OGT 25000 27.5 9480 36

FT8-3 SwiftPac304a 36.57 26.57 Net plant efficiency 50/60


Pratt & Whitney 50.6
Power Systems FT8-3 SwiftPac604b 74.185 54 Net plant efficiency 50/60
51.3

RB211-G62 DLE 37.7 26.7 7175 Net plant efficiency 50/60


Rolls-Royce Ltd
50.2
RB211-GT62 DLE 39.7 28.6 7005 Net plant efficiency 50/60
51.4
RB211-GT61 DLE 42.6 31.1 6820 Net plant efficiency 50/60
52.8
RB211-H63 WLE 54 40.9 7085 Net plant efficiency 50/60
50.8
RB211-H63 WLE 68.3 40.9 7428 Net plant efficiency 50/60
40.9
Trent 60 DLE 64.2 50 6837 Net plant efficiency 50
52.7%
Trent 60 DLE ISI 73.1 58 6790 Net plant efficiency 50
53
Trent 60 DLE 89.4 50 7172 Net plant efficiency 50
50.2
Trent 60 DLE ISI 101.6 58 7245 Net plant efficiency 50
49.7
Trent 60 DLE 64.6 50.4 6855 Net plant efficiency 60
52.5
Trent 60 DLE ISI 72.9 58 6785 Net plant efficiency 60
53.1
Trent 60 DLE 90.3 50.4 7191 Net plant efficiency 60
50.1
Trent 60 DLE ISI 100.9 58 7243 Net plant efficiency 60
49.7
Trent 60 WLE 75.1 59.4 7109 Net plant efficiency 50
50.6
Trent 60 WLE ISI 76.9 62.2 7200 Net plant efficiency 50
50
Trent 60 WLE 102.7 59.4 7389 Net plant efficiency 50
48.7
Trent 60 WLE ISI 107.6 62.2 7481 Net plant efficiency 50
48.1
Trent 60 WLE 75.2 59.4 7056 Net plant efficiency 60
51%
Trent 60 WLE ISI 77.2 62.4 7126 Net plant efficiency 60
50.5
Trent 60 WLE 101.8 59.4 7340 Net plant efficiency 60
49

36 www.peimagazine.com April 2012 - PEi

1204PEI_36 36 4/16/12 12:15 PM


Gas & Steam Turbine Directory

SHAFT SPEED TURBINE INLET EXHAUST MASS EXHAUST NOx EMISSIONS START-UP TIME DIMENSIONS
PRESSURE RATIO WEIGHT (TONNES)
(RPM) TEMPERATURE (C) FLOW (KG/S) TEMPERATURE (C) (PPMV) (MINUTES) LxWxH (METRES)

3000 21 755 587 15 30 480 18 x 6 x 6


3000 23 893 638 25 30 560 18 x 7 x 7

3000 14.7 1210 362 517 50 40 56.2 7 x 4 x 4.7

26000 6.7 8.7 555 15 1.6 2.4 x 1.2 x 1.5


26000 6.7 8.7 555 15 1.7 2.4 x 1.2 x 1.5

3000/1800 12 951 14.9 435


/1500
3000 13.85 1015 31 420
3000/3600 19.57 1075 71.3 433
3000/3600 21.8 1227 87.6 475

PEi - April 2012 www.peimagazine.com 37

1204PEI_37 37 4/16/12 12:15 PM


Gas & Steam Turbine Directory

GROSS OUTPUT NET OUTPUT (CC) NET OUTPUT (SC) HEAT RATE GROSS EFFICIENCY NET EFFICIENCY
MANUFACTURER MODEL FREQUENCY (HZ)
(MW) MW MW (KJ/KWH) % (CC) %

Net plant efficiency


Rolls-Royce Ltd Trent 60 WLE ISI 107.4 62.4 7432 60
48.4

SGT6-8000H 274
SGT5-4000F 292 9038
SGT5-2000E 167.9 10 366
SGT-800 47.03 9597
SGT-750 35.93 8811
SGT-700 35.93 9882
SGT-600 24.77 10 533
SGT-500 19.1 10 664
Siemens SGT-400 12.9 10 355
SGT-300 7.9 11 773
SGT-200 6.75 11 492
SGT-100 4.3 12 078
SGT-100 5.25 11 874
SGT-100 5.4 11 613
SGT6-2000E 113 10 606
SGT6-5000F 208 9446
SGT5-8000H 375

Saturn 20 1.21 14 795 24.3


Centaur 40 3.515 12 910 27.9
Centaur 50 4.6 12 270 29.3
Mercury 50 4.6 9351 38.4
Taurus 60 5.67 11 425 31.5
Taurus 60 (mobile 5.67 11 425 31.5
power unit)
Solar Gas Turbines Taurus 65 6.3 10 945 32.9
Taurus 70 7.52 10 650 32.8
Mars 90 9.45 11 300 31.8
Mars 100 11.43 10 885 33
Titan 130 15 10 230 34.1
Titan 130 (mobile 15 10 230 34.1
power unit)
Titan 250 21.745 9260 24.1

Notes:
1
BTU fuels
2
Including generator
3a
All ratings are defined at ISO standard reference conditions: 101.3 kPa, 15 oC and 60% RH.
3b
All ratings are based on the use of natural gas fuel at the generator terminals with standard inlet and exhaust losses.
3c
Start-up time is from ignition to full load without synchronization time.
3d
Combined-cycle performances are based on 1-on-1 configuration.
4a
1 x FT8-3
4b
2 x FT8-3

38 www.peimagazine.com April 2012 - PEi

1204PEI_38 38 4/16/12 12:15 PM


Gas & Steam Turbine Directory

SHAFT SPEED TURBINE INLET EXHAUST MASS EXHAUST NOx EMISSIONS START-UP TIME DIMENSIONS
PRESSURE RATIO WEIGHT (TONNES)
(RPM) TEMPERATURE (C) FLOW (KG/S) TEMPERATURE (C) (PPMV) (MINUTES) LxWxH (METRES)

3600 20 600 600


3000 18.2 692 577
3000 11.7 531 536
6608 19.9 131.5 544
6100 23.8 113.3 462
6500 18.6 94 528
7700 14 80.4 543
3600 13 97.9 369
9500 16.8 39.4 555
14010 13.7 30.2 542
11053 12.3 29.2 466
16500 13 17.6 527
17384 14.2 20.8 534
17384 15.6 20.6 531
3600 11.8 365 545
3600 17.2 510 567
3000 19.2 820 625

1800 6.7 6.5 505 9.98 5.8 x 1.7 x 2


1800 9.7 19 445 26.015 9.7 x 2.4 x 2.6
1800 10.6 19.1 510 27.08 9.8 x 2.4 2.8
1800 9.9 17.7 377 58.831 11.1 x 2.9 x 3.7
1800 12.5 21.8 510 33.87 9.8 x 2.7 x 3.0
1800 12.5 21.8 510 33.045 9.8 x 2.5 x 2.9

1800 15 21.1 550 52.175 10.4 x 3.1 x 3.6


1800 16 26.9 485 67.57 14.5 x 2.5 x 3.6
1800 16.3 40.1 465 67.57 14.5 x 2.8 x 3.6
1800 17.7 42.2 485 73.668 14 x 3.3 x 3.3
1800 17.1 49.8 495
1800 140.62 18.1 x 3.7 x 4.2

1800 24.1 68.2 465 9.1 4.4 x 1.7 x 3.5

PEi - April 2012 www.peimagazine.com 39

1204PEI_39 39 4/16/12 12:15 PM


Gas & Steam Turbine Directory

Steam Turbine Technical Data


DIMENSIONS
POWER RATING INLET TEMP INLET PRESSURE GAS FLOW
OEM MODEL TYPE/APPLICATION SHAFT SPEED( RPM) LXWXH
(MW) (oC) (BAR) RATE (M3/H)
(METRES)

GRT Biomass/industrial/waste-to-energy/ 560 50/60Hz


SCP applicable
GST Geothermal 2060 50/60Hz
applicable
TM2 Concentrated solar power 4560 50/60Hz
applicable
MT Biomass/industrial/waste-to-energy/ 50130 50/60Hz
Concentrated solar power applicable
COMAX Cogeneration 100400 50/60Hz
applicable
STF15C Combined-cycle 100250 50/60Hz
applicable
Alstom Power
STF30C Combined-cycle 150400 50/60Hz
applicable
STF25 Steam power 100350 50/60Hz
applicable
STF40 Steam power 250700 50/60Hz
applicable
STF60 Steam power 500900 50/60Hz
applicable
STF100 Steam power 7001200 50/60Hz
applicable
ARABELLE Nuclear power up to 1800 50/60Hz
applicable

GT series Geothermal 20150 50/60 Hz


applicable
MCT series Cogeneration 100250 50/60 Hz
applicable
MT5 Combined-cycle 4090 50/60 Hz
applicable
MT10 Combined-cycle 80160 50/60 Hz
applicable
MT15 Combined-cycle 90150 50/60 Hz
applicable
Ansaldo Energia MT20 Combined-cycle 150250 50/60 Hz
applicable
MT25 Fossil 100300 50/60 Hz
applicable
RT20/30 Combined-cycle 150350 50/60 Hz
applicable
RT40 Fossil 300500 50/60 Hz
applicable
RT70 Fossil 500900 50/60 Hz
applicable
RT100 Fossil 9001200 50 Hz applicable

Engineered Multi-stage 500 kW 100 MW 75018 000 Varies up to 565 Up to 138


(1050 oF) (2000 psig)
Dresser-Rand
9 models available Single-stage 1 kW 3 MW 50015 000 Varies up to 540 up to125
(1000 oF) (1800 psig)

A Series Fossil up to 250 50/60 Hz


applicable
D Series Fossil 200500 50/60 Hz
applicable
G Series Fossil - three casing 400750 50/60 Hz
GE Energy
applicable
G Series Fossil - four casing 650900 50/60
applicable
N Series Nuclear power up to 1500 50/60
applicable

40 www.peimagazine.com April 2012 - PEi

1204PEI_40 40 4/16/12 12:15 PM


Gas & Steam Turbine Directory

DIMENSIONS
POWER RATING INLET PRESSURE GAS FLOW
OEM MODEL TYPE/APPLICATION SHAFT SPEED( RPM) LXWXH INLET TEMP (oC)
(MW) (BAR) RATE (M3/H)
(METRES)

Standard Power Generation 2160 50/60 Hz 540 140


applicable
Low-pressure turbines Power Generation 590 50/60 Hz saturated steam 1-20
applicable
Air turbines CAES (compressed Air Energy Storage) 2590 50/60 Hz 540 140
applicable
MAN Diesel &
MARC 1 Combined heat and power generation 24 50 Hz applicable 450 65
Turbo SE
for reneable energy and WtE
MARC 2 Combined heat and power generation 510 50 Hz applicable 520 90
for RE and WtE
MARC 4 combined heat and power generation 820 50 Hz applicable 520 120
for RE and WtE
MARC 6 combined heat and power generation 1640 50 Hz applicable 530 120
for RE and WtE

SST-010 up to 0.11 1.2 x 0.8 x 0.9 up to 15 000


SST-040 up to 0.3 2.5 x 1.5 x 2 up to 400 up to 40
SST-050 up to 0.750 1 x 1 x 1.3
SST-060 up to 6 1.5 x 2.5 x 2.5 up to 131
SST-110 up to 7 6 x 2.8 x 3.2 up to 131
SST-120 up to 10 9 x 2.8 x 3.2 up to 131
SST-900 up to 250 30003600 20 x 11 x 10 up to 585 up to 165
SST-600 up to 100 300015 000 19 x 6 x 5 up to 540 up to 140
SST-700 up to 175 300013 200 22 x 15 x 6 up to 585 up to 165

Siemens SST-800 up to 150 30003600 20 x 8.5 x 6 up to 540 up to 140


SST-300 up to 50 up to 12 000 12 x 4 x 5 up to 520 up to 120
SST-400 up to 65 30008000 18 x 8.5 x 5.5 up to 540 up to 140
SST-500 up to 100 up to 15 000 19 x 6 x 5 up to 400 up to 30
SST-100 up to 8.5 up to 7500 8 x 3.7 x 3.4 up to 480 up to 65
SST-150 up to 20 up to 13 300 12 x 4 x 5 up to 505 up to 103
SST-200 up to 10 4 x 2 x 2.5 up to 520 up to 110
SST-6000 3001200 up to 600 up to 300
SST-5000 120750 up to 600 up to 190
SST-3000 90250 up to 565 up to 177

Backpressure BT20 10 13 600 depending on 540 140


reaction turbines power output
Condensation BT63 100 4300 540 140
TGM Kanis Turbinen reaction turbines
GmbH
CT20-30 10 13 600 depending on 540 140
power output
CT63-100 100 4000 540 140

42 www.peimagazine.com April 2012 - PEi

1204PEI_42 42 4/16/12 12:15 PM

You might also like