JOB NUMBER: 0 Page

Isolated Foundation(F-1) (ACI 318M-95) PREPARED BY: 0


3 of 4
CHECKED BY: 0
PROJECT: MOSQUE -AL-NAKHEEL 6
DATE: Jan-1900

CHECK FORCE TRANSFER AT COLUMN

Bearing strength of column


Pnb (0.85fcA1) > Pu 9475.38 KN OK ACI-SECT.10.17.1
0.65
A1 490000 mm2

CHECK FORCE TRANSFER AT COLUMN

Bearing strength of footing


Pnb (0.85fcA1)(A2/A1)0.5 > Pu 45346.4 KN OK ACI-SECT.10.17.1
0.65
A1 490000 mm2
A2 11222500 mm2 Use minimum dowels 0.005*A1 2450 mm2

CHECK DEVELOPMENT LENGTH FOR COLUMN DOWELS

Column Vertical dowels


ld required 203 mm < d OK Per SABP-002-table-3

Footing Bottom bars


ld required 268 mm < 1287.5 OK Per SABP-002-table-4
with alpha value reduces

Footing Top bars


ld required 268 mm < 1287.5 OK Per SABP-002-table-5
with alpha value reduces