DESIGN SUMMARY:
FOOTING DIMENSION (mm) FOOTING RIENFORCEMENT SPACINGS (mm) PEDESTAL (mm) REINFORCEMENT
BAR USED NO.OF BARS
L B D X-DIR Z-DIR X Y MAIN TIES
TOP BOTTOM X-DIR Z-DIR
41.9336 41.933598 10 @
3350 3350 600 12 12 77.9762 77.9762 700 700 14
say 42 42 200 O/C
SKETCHES:
Fy = 1573 KN
Mz = 103 KN.m
Fx = 0 kN
h= 0
GWT
D = 600 d = 515 mm
L = 3350 mm
B= 3350
y = 700 x
x = 700
* Dimensions are in mm