Professional Documents
Culture Documents
Department of Education
Region VII, Central Visayas
Division of Cebu City
TISA NATIONAL HIGH SCHOOL
F. Llamas St. Tisa Cebu City
_____ 25. It is a term referring to the use of electrical instruments in testing the wiring installation for accuracy.
a. assessment b. Examine c. Testing d. Commissioning
_____ 26. What is the unit in measuring voltage?
a. ohm b. ampere c. volt d. hertz
_____ 27. It is an instrument used to measure voltage.
a. ohmmeter b. voltmeter c. ammeter d. clamp ammeter
_____ 28. Which of the following action should be done when measuring voltage?
a. test the circuit for voltage immediately to avoid waste of time c. adjust the pointer to zero
b. set the selector to a higher range d. test the circuit for resistance
_____ 29. The ideal size of the wire to be use for lighting outlet.
a. #8 AWG b. #10 AWG c. #12 AWG d. #14 AWG
_____ 30. The ideal size of the wire to be use for convenience outlet.
a. #8 AWG b. #10AWG c. #12 AWG d. #14 AWG
_____ 31. Which of the following breakers should be use for heavy current consuming appliances?
a. 30A b. 40A c. 20A d. 15A
_____ 32. Which of the following wire sizes is to be used for the special purpose outlet?
a. #10 AWG b. #12 AWG c. #14 AWG d. #16 AWG
_____ 32. What should be the ideal length of the wire that will come out from the junction box intended for
splicing? a. b. 2 to 2 C. 4 d. 3
_____ 33. In installing switches, what should be the length of the skinned wire to be inserted to the switch?
a. b. 2 to 2 c. 4 d. 3
_____ 34. What should be the ideal length of the wire that will come out in the utility box intended for switch
connection? a. b. 2 to 2 c. 4 d. 3
_____ 35. It is where splices or joints in the circuit were being made.
a. utility box b. junction box c. square box d. toolbox
_____ 36. It is used when mounting a flash type switch.
a. utility box b. junction box c. square box d. toolbox.
_____ 37. How many bends are allowed for a conduit run?
a. 2 b. 3 c. 4 d.5
_____ 38. The following are examples of conduit bends EXCEPT
a. saddle bend b. offset bend c. elbow bend d. arm bend
_____ 39. A type of splice used inside the junction box.
a. western union short tie b. western union long tie c. rat tail d. plain tap
_____ 40. PPEs that should be worn when cutting metal with a hack saw.
a. gloves and goggles b. gloves and apron c. gloves and shades d. gloves and long sleeves
_____ 41. A type of switch used to control one lamp in two different locations.
a. SPST b. SPDT c. three-way d. four way
_____ 42. It is where the breakers were being place.
a. junction box b. utility box c. panel board d. main switch box
_____ 43. What are you going to do if you notice a wire hanging from the ceiling?
a. pull it and keep for safe c. test if it is live by touching
b. cut it using pliers d. test if it is live using multi-tester
_____ 44. In sizing wires, the bigger the number, the _____________ the wire is.
a. smaller b. bigger c. longer d. shorter
_____ 45. In resistance reading, what is the equivalent per scale in number 5 to 10?
a. .2 b.2 c. .5 d. 5
46 -50. Refer to the electrical plan given. List down electrical fixtures/materials and their quantity found in the
plan.