SPECIFICATIONS
MODEL DCA-45ESI
Alternator
Frequency Hz 50 60
Continuous 37 45
Rated Output (kVA)
Standby 38.9 47.3
Dual Voltage
Rated Voltage (V)
190-220V, 380-440V 190-240V, 380-480V
Power Factor 0.8
No. of Phase 3 Phase, 4 wire
Exciting system Brushless, Rotating Exciter (with A.V.R)
Diesel Engine
Manufacturer & Model Isuzu BB-4JG1T
Type In lined, Direct Injected, Turbocharged
Bore x stroke 4-95.4x107
Displacement (L) 3.059
Rated Output (kw/min-1) 34.2/1500 rpm 41.2/1800 rpm
Fuel ASTM No. 2 Diesel Fuel or Equivalent
Fuel Tank Capacity (L) 100
Fuel Consumption (L/H) 6.3 7.8
Battery 95D31Rx1
Dimensions and Weight
1900
Length (mm)
Width (mm) 880
Height (mm) 1250
Dry Weight (kg) 960
Sound Level
7m dB (A) 1500/1800rpm (min1) 60 62
*1 Rated Voltage Classification
Frequency 50Hz 60Hz
190-220V 200-240V
190-220V 190-240V
380-440V 380-480V
380-440V 380-480V
*2 Fuel Consumption is based on operation at 75%
*3 Sound level reflects high-speed operation and is calculated by averaging the measurements at four points, each 7 meters from the
source
*4 Depending on location and area, output voltage may differ from values listed in catalog
The specifications given herein are subject to change without notice.

www.dmgenerator.com / Email: info@dmgenerator.com / Mob. +966566699789


characteristics of the generators job. To meet this requirement
output. Denyos DCA Series generators
PERFORMANCE incorporate a built-in parallel
ECONOMICAL PERFORMANCE
FEATURES operation drive system, allowing
-Easy starting and quick response. plant on-site, without the need to
HIGH PERFORMANCE procure any other equipment.
-Utilizing highly reliable diesel
The Denyo generating systems engines with low fuel DUAL VOLTAGE
guarantees the following levels of consumption, manufactured by
performance: For companies that operate
Japans leading engine internationally or have motors
TEMPERATURE: 100C manufacturers. that require power at different
temperature rise at 40C ambient -Uninterrupted generator voltages, a different generator is
(JEC2130) operation for up to 12 hours usually required for each voltage
under 75% load. setting. However, the DCA Series
VOLTAGE REGULATION: Within
generators are equipped with a
0.5% (except DCA 400SP) UNSURPASSED FLEXIBLITY dual voltage system, so one
FREQUENCY REGULATION: generator can be used to power
To meet todays varying needs
Within 5.0% through no load to motors with different voltage
successfully, your equipment
full-load. settings. An extremely convenient
must be as flexible as you are.
feature.
INSULATION RESISTANCE The Denyo DCA Series generator
range provides you with the ALL MODELS CAN RUN AT
-Higher than 3 Mega-ohms, flexibility to get the job done 50Hz/60Hz
measured between armature simply and economically, without
windings and earth, field windings any delays. Simply adjust the engine speed
and earth, field control circuit and on the control panel to use a DCA
earth. TRUE HEAVY-DUTY Series generator at either 50Hz or
PERFORMANCE 60Hz.
- The innovative excitation
system* fitted on all models, in For a particular job, you may EXTREMELY QUIET OPERATION
conjunction with the AVR and need that extra power from
generator. With the DCA Series, In urban areas and at the
advanced brushless generator,
the standby power rating (110% worksite, there is an ever
provides fast voltage regulation in
or 105% load except DCA- increasing demand for reduced
response to load variations,
610SPM) can be used noise pollution. In response to
enabling use soon after start up.
continuously for 1 hour in every 8 these concerns, Denyo has
This system provides output
hours of continuous operation. pioneered and a soundproof and
stability during load variations.
This extra power performance of super soundproof range of
- Synchronous brushless Denyo generators means you can generators. The DCA Series
alternator for minimal wear. get the job done, without the generators are extremely quiet
inconvenience of using another when operating at full load, even
-Designed to function in all though all soundproof models are
generator.
climatic conditions. compactly designed. Check the
specifications for the sound level
-Will safely power the
of each model.
most sensitive loads, such as PARALLEL OPERATION FEATURE
thyristors, investors and
computer systems, without the time to time, at a construction
risk of damage to these loads, site, mine site or in other
thanks to the high level electrical situations, large temporary power
supply is required for a particular
www.dmgenerator.com / Email: info@dmgenerator.com / Mob. +966566699789
www.dmgenerator.com / Email: info@dmgenerator.com / Mob. +966566699789