You are on page 1of 1

LIGHTING FIXTURE

MAX HEIGHT = 200mm

0.20
2" X 8" CAP
4 -12mm VERTICAL REBARS

10mm TIE BARS SPACED;

0.20
5@100mm; 5@150mm;REST
4 -12mm VERTICAL REBARS @ 200mm

0.50
0.20

4- 12mm REBARS SPACED


@ 100mm BOTH WAYS

0.50
0.20
1.80

0.35

10mm HORIZONTAL BARS


FROM CHB REINFORCEMENT
ANCHORED TO COLUMN
POST 8"X 2" CAP
MAX ZOCALO HT. 2 DETAIL OF COLUMN FOOTING
S-1 SCALE: 1:15MTS 10mm HORIZONTAL BARS SPACED @
EVERY 3 LAYERS OF CHB

0.40
10mm VERTICAL BARS
0.40

SPACED @ 800mm O.C

10mm VERTICAL BARS


FROM CHB REINFORCEMENT NGL SIDE WALK
SPACED @ 800mm O.C
NGL

10mm TIE BARS SPACED;

0.42
5@100mm; 5@150mm;REST

0.57
0.40

@ 200mm
150X200X400mm CHB

0.05
4- 12mm REBARS SPACED 10mm DOWELS TO MATCH VERTICAL WALL
@ 100mm BOTH WAYS REINFORCEMENT ALTERNATE BENDS

0.15
3-12mm cont. REBARS
0.15

0.30

1 SECTION OF COLUMN 3 SECTION OF ZOCALO WALL


S-1 SCALE: 1:15MTS S-1 SCALE: 1:15MTS

CIVIL ENGINEER: PROJECT TITLE: APPROVED: SHEET CONTENT: DATE ISSUED: SHEET NO.:

----------
DATE REVISED:

----------
PROPOSED RESIDENTIAL REVISION NO.:
S-01
STRUCTURAL DETAILS
PRC NO. PRT NO.: PROPERTY FENCE MARICRIS PERALTA JAMIAS
OWNERS
ANGELA PERALTA JAMIAS
REF. NO.:
----------

ARMAQ TIN: ISSUED ON: BLOCK 9 LOT 1


RA 9266 : THIS DRAWING AS AN INSTRUMENT OF BRGY. PASONG CAMACHILLE, GENERAL TRIAS, CAVITE ----------
SERVICE IS THE
PROPERTY OF ARCH. MARK ANTHONY C. QUINITIO AND E:\SEAGATE BACKUP\Seagate
SUCH MUST NOT BE ISSUED AT: CADD FILE:
Backup Plus
REPRODUCED OR COPIED IN OR IN WHOLE WITHOUT Drive(F#)\sideline\Fence
Lancaster Gabriel\Gabrele
4 OF 4
PERMISSION. Fence.dwg