You are on page 1of 4

H07VVH6-F

PVC FLAT CABLES

Description

Application
H07VVH6-F power and control flat cables can be used on festoons
systems on handling equipment as overhead cranes. They are specially
designed for indoor and outdoor applications.

Design
Conductor
Plain copper
Flexible class 5
IEC 60228
Insulation
PVC (polyvinyl chloride)
Standards
A thread are placed in each group of cores to strip the outer sheath
International HD 359 S2; IEC
Outer sheath 60227-6
PVC (polyvinyl chloride)
Colour: black

Marking
H07VVH6-F or 07VVH6-F - Number of cores - cross section - NEXANS -
year - week

Cores identification
In accordance with HD 308 S2
4 cores: black - grey - green/yellow - brown
5 cores: black - grey - green/yellow - brown - blue
From 6 cores: black with white printed numbers + green/yellow

Lead free Cable flexibility Mechanical resistance to Weather resistance Chemical resistance Operating temperature,
Yes Flexible impacts Good Oil resistant range
Good -25 .. 60 C

Version V05 Generated 4/18/06 - http://www.nexans.fr/e-service/ Page 1 / 4


All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
H07VVH6-F
Related Information
Contact
Nexans - Special cables
170 avenue Jean Jaurs
69353 Lyon Cedex 07
France
virginie.greppa@nexans.com

Lead free Cable flexibility Mechanical resistance to Weather resistance Chemical resistance Operating temperature,
Yes Flexible impacts Good Oil resistant range
Good -25 .. 60 C

Version V05 Generated 4/18/06 - http://www.nexans.fr/e-service/ Page 2 / 4


All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
H07VVH6-F
Characteristics
Construction characteristics
Conductor material Plain copper
Conductor flexibility Flexible class 5
Insulation PVC
Lead free Yes
Outer sheath PVC
Sheath colour Black
With Green/Yellow core Yes
Electrical characteristics
Rated Voltage Uo/U 450 / 750 V
Mechanical characteristics
Cable flexibility Flexible
Mechanical resistance to impacts Good
Usage characteristics
Weather resistance Good
Chemical resistance Oil resistant
Maximum core temperature still 70 C
Operating temperature, range -25 .. 60 C

H07VVH6-F
Cross section Approx. weight
Nb. of cores External dimensions Packaging
mm kg/km
4 1.5 15 x 5 mm 150 Cut to length
4 1.5 15 x 5 mm 150 D500
4 2.5 210 Cut to length
4 2.5 210 D500
4 4 21 x 6.5 mm 300 Cut to length
4 4 21 x 6.5 mm 300 D500
4 6 23 x 7 mm 390 Cut to length
4 6 23 x 7 mm 390 D500
4 10 29 x 9 mm 620 Cut to length
4 10 29 x 9 mm 620 D500
4 16 37 x 11 mm 990 Cut to length
4 16 37 x 11 mm 990 D500
4 25 1550 Cut to length
4 25 1550 D500
4 35 2030 Cut to length
4 35 2030 D500
4 50 56 x 16.5 mm 2650 Cut to length
4 70 63 x 18 mm 3650 Cut to length
4 95 4550 Cut to length
5 1.5 18 x 5 mm 180 Cut to length
5 1.5 18 x 5 mm 180 D500
5 2.5 260 Cut to length

Version V05 Generated 4/18/06 - http://www.nexans.fr/e-service/ Page 3 / 4


All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
H07VVH6-F
Cross section Approx. weight
Nb. of cores External dimensions Packaging
mm kg/km
5 2.5 260 D500
5 4 380 Cut to length
5 6 480 Cut to length
5 10 780 Cut to length
5 16 1200 Cut to length
7 1.5 26 x 5 mm 260 Cut to length
7 1.5 26 x 5 mm 260 D500
7 2.5 380 Cut to length
7 2.5 380 D500
7 4 550 Cut to length
7 6 41 x 7 mm 700 D500
8 1.5 29 x 5 mm 300 Cut to length
8 1.5 29 x 5 mm 300 D500
8 2.5 405 Cut to length
8 2.5 405 D500
10 1.5 35 x 5 mm 360 D500
12 1.5 40.5 x 5 mm 420 Cut to length
12 1.5 40.5 x 5 mm 420 D500
12 2.5 620 Cut to length
12 2.5 620 D500
12 4 880 Cut to length
14 1.5 490 D500
16 1.5 560 Cut to length
16 1.5 560 D500
18 1.5 58 x 5 mm 620 Cut to length
18 1.5 58 x 5 mm 620 D500