You are on page 1of 7

Off-Grid Module

Product Catalog

www.suntech-power.com
Suntechs Solar Products

Suntech offers a broad range off-grid solar modules designed


for urban and rural applications including telecommunications,
Why Suntech?
data collection, water pumping, and illumination. Suntech solar
panels have been used in thousands of stand-alone systems Broad product range, from 5W to 135W
worldwide. The excellent performance of the system brings IP 65 rated junction box
electricity and light in remote locations and also serves as an
Superior module temperature
independent power supply solution in high-quality industrial
coefficients2
applications.
Excellent product warranty terms
Suntech is the worlds largest crystalline silicon solar module
IEC and UL certified
manufacturer with more than 2.5GW of solar products installed
worldwide. All products are designed in conformity with both
IEC and UL standards1 and manufactured in ISO9001 and
ISO 14001 certified production facilities. Suntech is also an Product Manual Series:
active member of PV Cycle, an independent PV industry

1
association dedicated to establishing a take-back and recycling
Standard Module
program for PV solar modules and their end-of-life waste. All
Suntech off-grid solar modules come with a 25-year warranty
Product Catalog

2
on power output and a 5-year warranty on material and
Off-Grid Module
workmanship.
Product Catalog

1. Please contact a local sales representative for details.


2. Please refer to Suntech product data sheet.
www.suntech-power.com Email: sales@suntech-power.com

SPECIFICATION STP005B STP010D STP020B STP030D STP040D STP045D STP050D STP055D STP060D STP065D STP085B STP090B STP130D STP135D
-12/DEA -12/KEA -12/CEA -12/LEA -12/REA -12/REA -12/MEA -12/MEA -12/SEA -12/SEA -12/BEA -12/BEA -12/TEA -12/TEA
CATEGORIES
Open-Circuit Voltage 21.6 V 21.6 V 21.7 V 21.6 V 21.8 V 22.0 V 21.8 V 22.2 V 21.6 V 21.8 V 22.2 V 22.4 V 22.0 V 22.3 V
(Voc)
Optimum Operating 17.4 V 17.4 V 17.6 V 17.2 V 17.4 V 17.6 V 17.4 V 17.5 V 17.4 V 17.6 V 17.8 V 18.0 V 17.4 V 17.5 V
Voltage (Vmp)

Short-Circuit Current (Isc) 0.32 A 0.65 A 1.26 A 1.94 A 2.58 A 2.79 A 3.13 A 3.34 A 3.90 A 4.11 A 5.15 A 5.29 A 8.09 A 8.20 A

Optimum Operating 0.29 A 0.57 A 1.14 A 1.74 A 2.30 A 2.56 A 2.93 A 3.14 A 3.45 A 3.69 A 4.80 A 5.00 A 7.47 A 7.71 A
Current (Imp)
Maimum Power at STC* 5 Wp 10 Wp 20 Wp 30 Wp 40 Wp 45 Wp 50 Wp 55 Wp 60 Wp 65 Wp 85 Wp 90 Wp 130 Wp 135 Wp
(Pma)
Operating Temperature -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C

Maimum System Voltage 30 V DC 30 V DC 30 V DC 30 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC 1000 V DC

Maimum Series Fuse

ELECTRICAL CHARACTERISTICS
5A 5A 5A 5A 10 A 10 A 10 A 10 A 15 A 15 A 15 A 15 A 20 A 20 A
Rating
Power Tolerance 10 % 10 % 10 % 10 % 5 % 5 % 5 % 5 % 5 % 5 % 5 % 5 % 5 % 5 %

Nominal Voltage 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V

Solar Cell Monocrystalline Polycrystalline Monocrystalline Polycrystalline Polycrystalline Polycrystalline Polycrystalline Polycrystalline Polycrystalline Polycrystalline Monocrystalline Monocrystalline Polycrystalline Polycrystalline

No. of Cells 36 (49) 36 (66) 36 (218) 36 (49) 36 (49) 36 (49) 36 (49) 36 (49) 36 (49) 36 (49) 36 (49) 36 (49) 36 (49) 36 (49)

21630618 / 31036818 / 65630618 / 42668018 / 53766530 / 53766530 / 63166530 / 63166530 / 77166530 / 77166530 / 119554130 / 119554130 / 148267635 / 148267635 /
Dimensions (mm/inch) 8.512.00.7 12.214.50.7 25.812.00.7 16.826.80.7 21.126.21.2 21.126.21.2 24.826.21.2 24.826.21.2 30.426.21.2 30.426.21.2 47.021.31.2 47.021.31.2 58.326.61.4 58.326.61.4

Weight (kg/lbs) 0.8 / 1.8 1.5 / 3.3 2.5 / 5.5 3.2 / 7.0 4.5 / 9.9 4.5 / 9.9 5.3 / 11.7 5.3 / 11.7 6.2 / 13.7 6.2 / 13.7 8 / 17.6 8 / 17.6 12 / 26.4 12 / 26.4

IP65 rated IP65 rated IP65 rated IP65 rated


Junction Bo IP65 rated IP65 rated IP65 rated IP65 rated IP65 rated IP65 rated IP65 rated IP65 rated IP65 rated IP65 rated
(Openable) (Openable) (Openable) (Openable)

H+S (12 AWG) H+S (12 AWG) H+S (12 AWG) H+S (12 AWG) H+S (12 AWG) H+S (12 AWG) H+S (12 AWG) H+S (12 AWG) H+S (12 AWG) H+S (12 AWG)

Symmetrical Symmetrical Symmetrical Symmetrical Symmetrical Symmetrical Symmetrical Symmetrical Symmetrical Symmetrical
Lengths (-) Lengths (-) Lengths (-) Lengths (-) Lengths (-) Lengths (-) Lengths (-) Lengths (-) Lengths (-) Lengths (-)
Output Cables (mm/inch) 750 / 29.5 and 750 / 29.5 and 750 / 29.5 and 750 / 29.5 and 750 / 29.5 and 750 / 29.5 and 750 / 29.5 and 750 / 29.5 and 750 / 29.5 and 750 / 29.5 and

MECHANICAL CHARACTERISTICS
(+) 750 / 29.5 (+) 750 / 29.5 (+) 750 / 29.5 (+) 750 / 29.5 (+) 750 / 29.5 (+) 750 / 29.5 (+) 750 / 29.5 (+) 750 / 29.5 (+) 750 / 29.5 (+) 750 / 29.5

MC4 Connectors MC4 Connectors MC4 Connectors MC4 Connectors MC4 Connectors MC4 Connectors MC4 Connectors MC4 Connectors MC4 Connectors MC4 Connectors

Nominal Operating Cell 452C 452C 452C 452C 452C 452C 452C 452C 452C 452C 452C 452C 452C 452C
Temperature (NOCT**)

Temp. coefficient of Pma -0.48 %/C -0.47 %/C -0.48 %/C -0.47 %/C -0.48 %/C -0.48 %/C -0.47 %/C -0.47 %/C -0.47 %/C -0.47 %/C -0.48 %/C -0.48 %/C -0.47 %/C -0.47 %/C

TEMP.
Temp. coefficient of Voc -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C -0.34 %/C

0.037 %/C 0.045 %/C 0.037 %/C 0.045 %/C 0.037 %/C 0.037 %/C 0.045 %/C 0.045 %/C 0.045 %/C 0.045 %/C 0.037 %/C 0.037 %/C 0.045 %/C 0.045 %/C

CHARACTERISTICS
Temp. coefficient of Isc
*STC: Irradiance 1000W/m2, module temperature 25C, AM=1.5 **NOCT: Irradiance 800W/m2, ambient temperature 20C, wind speed 1m/s
5W ~ 20W
STP005B-12/DEA
A A Junction box

Fixing groove Module IV Graph 5W

201.9 [7.9]
4 places

216 [8.5]
10.5 [0.41] BACK VIEW
5
0.3

Current (A)

Power (W)
3

2
291.9 [11.5]

306 [12.0] 1

0 0
Section A-A 0 5 10 15 20
SIDE VIEW 81 [3.2]
22 [0.9]
14.1 [0.6] Voltage (V)
20 [0.8]
18 [0.7]
18 [0.7]

216 [8.5]

STC IV data 800 W/m2 IV data 600 W/m2 IV data


Note: mm [inch] 14.1 [0.6] STC PV data 800 W/m2 PV data 600 W/m2 PV data

STP010D-12/KEA 353.9 [13.9]

Junction box
Module IV Graph 10W
A A

0.8 12

Fixing groove
295.9 [11.6]

310 [12.2]

4 places
10.5 [0.41] BACK VIEW 9
Current (A)

Power (W)
0.4 6

FRONT VIEW 3

368 [14.5] 0 0
0 5 10 15 20

Voltage (V)

Section A-A
SIDE VIEW 81 [3.2] 29 [1.1]

20 [0.8] 14.1 [0.6]


18 [0.7]
310 [12.2] STC IV data 800 W/m2 IV data 600 W/m2 IV data
18 [0.7]

STC PV data 800 W/m2 PV data 600 W/m2 PV data

14.1 [0.6]
Note: mm [inch]

STP020B-12/CEA Blueprint of the module


18 [0.7]
291.9 [11.5]
81 [3.2] 29 [1.1]

Module IV Graph 20W

Junction 1.5
box 24

20
20 [0.8]
1.0 16
Current (A)

Power (W)

12

0.5 8
641.9 [25.3]

656 [25.8]

656 [25.8]

4
Fixing groove
4 places
0 0
10.5 [0.41] 0 5 10 15 20

Voltage (V)
BACK VIEW
A A Section A-A

14.1 [0.6]
18 [0.7]

STC IV data 800 W/m2 IV data 600 W/m2 IV data


SIDE VIEW

STC PV data 800 W/m2 PV data 600 W/m2 PV data


FRONT VIEW
14.1 [0.6]

Note: mm [inch]
306 [12.0]
30W ~ 50W
STP030D-12/LEA 665.9 [26.2]

Junction box
A A Module IV Graph 30W

2.0
Fixing 30

411.9 [16.2]
groove

426 [16.8]
4 places
1.5 25
10.5 [0.41]
BACK VIEW

Current (A)

Power (W)
20

1.0
15

FRONT VIEW 0.5


10

680 [26.8] 0 0
0 5 10 15 20

Voltage (V)
SIDE VIEW 81 [3.2] 29 [1.1] Section A-A
20 [0.8] 14.1 [0.6]
18 [0.7]
426 [16.8]
18 [0.7]

STC IV data 800 W/m2 IV data 600 W/m2 IV data


STC PV data 800 W/m2 PV data 600 W/m2 PV data
Note: mm [inch] 14.1 [0.6]

STP040D-12/REA Blueprint of the module

632 [24.9]
Module IV Graph 40W
430 [16.9]

Drainage holes 3.0


Junction box* 40
2.5
14 9 [0.55 0.35]
Mounting slots 30
8 places 2.0
Current (A)

Power (W)
A A
1.5
504 [19.8]
302 [11.9]

537 [21.1]

20

2-5.1 [0.2] BACK VIEW 1.0


Ground holes 10
2 places 0.5

0 0
0 5 10 15 20
FRONT VIEW Voltage (V)

665.0 [26.2]

12 [0.5] STC IV data 800 W/m2 IV data 600 W/m2 IV data

Section A-A STC PV data 800 W/m2 PV data 600 W/m2 PV data
30 [1.2]

2 [0.08]
Note: mm [inch]
*Both UL and IEC certified types available
25 [1.0]

STP050D-12/MEA Blueprint of the module

632 [24.9]
Module IV Graph 50W
430 [16.9]

3.5 60
Drainage holes
3.0
Junction box*
14 9 [0.55 0.35] 2.5
40
Current (A)

Mounting slots
Power (W)

8 places 2.0
A A
598 [23.5]
631 [24.8]
396 [15.6]

1.5
2-5.1 [0.2]
Ground holes
BACK VIEW 1.0
20

2 places
0.5

0 0
0 5 10 15 20 25

FRONT VIEW Voltage (V)

665 [26.2]

12 [0.5] STC IV data 800 W/m2 IV data 600 W/m2 IV data


Section A-A STC PV data 800 W/m2 PV data 600 W/m2 PV data
30 [1.2]

2 [0.08]
Note: mm [inch]
25 [1.0] *Both UL and IEC certified types available
60W ~ 130W
Blueprint of the module
STP060D-12/SEA 632 [24.9]
430 [16.9]

Module IV Graph 60W


Drainage holes
Junction box*
4.0
14 9 [0.55 0.35] 60
Mounting slots 3.5
8 places
50
A A 3.0

Current (A)

Power (W)
2.5 40

771 [30.4]
536 [21.1]
738 [29.1]
2.0
2-5.1 [0.2] 30
Ground holes 1.5
2 places BACK VIEW 1.0
20

10
0.5

0 0
0 5 10 15 20
FRONT VIEW Voltage (V)

665 [26.2]
12 [0.5]
Section A-A
STC IV data 800 W/m2 IV data 600 W/m2 IV data
30 [1.2]

STC PV data 800 W/m2 PV data 600 W/m2 PV data


2 [0.08]
Note: mm [inch]
*Both UL and IEC certified types available
25 [1.0]

Blueprint of the module


STP085B-12/BEA 508 [20.0]

Drainage holes
Module IV Graph 85W

Junction box*
14 9 [0.55 0.35] 90
Mounting slots 5
8 places 75

4
60
Current (A)

Power (W)
3
45
A A
2 30

1 15
1195 [47.0]
960 [37.8]
660 [26.0]

2-4 [0.16]
Ground holes
2 places
BACK VIEW 0
0 5 10 15 20
0

Voltage (V)
Section A-A
12 [0.5]
30 [1.2]

2 [0.08]
STC IV data 800 W/m2 IV data 600 W/m2 IV data
STC PV data 800 W/m2 PV data 800 W/m2 PV data
25 [1.0]

Note: mm [inch] FRONT VIEW


*Both UL and IEC certified types available
541 [21.3]

STP130D-12/TEA Blueprint of the module 626 [24.6]

Drainage holes
Module IV Graph 130W
Junction box*
14 9 [0.55 0.35] 8
Mounting slots 7
8 places 120

6
90
Current (A)

Power (W)

4
60
3
A A
2
702 [27.6]

30
1482 [58.3]
1202 [47.3]

1
2-4 [0.16] 0
Ground holes
2 places
BACK VIEW 0
0 5 10 15 20

Section A-A Voltage (V)

11 [0.4]
35 [1.4]

1 [0.06]
STC IV data 800 W/m2 IV data 600 W/m2 IV data
35 [1.4]
STC PV data 800 W/m2 PV data 800 W/m2 PV data

Note: mm [inch]
FRONT VIEW
*Both UL and IEC certified types available
676 [26.6]
Off-Grid Module Product Catalog 7

Suntech Application Examples


Meeting All Your Off-Grid Requirements

01 02 03
Signal transfering station Remote rural electrification 43 kWp Solar powered water pumping
and desalination system (43kWp
inDubai, UAE)

04 05 06
Road security and railroad signals Solar powered lights, such as traffic Medical and education facilities in
systems lights, street lamp and etc rural areas

07 08
Pumping systems for irrigation, rural water supplies and livestock Power source for vacation homes

09 10 11
Remote solar home systems (50 kWp in Aviation directional lighting Marine charging systems
Indonesia)

You might also like