Screening Tool For New Building Design Page 1 / 6

Screening Tool For New Building Design

Screening Tool Summary

Facility Description for Thanh Trung Nguyen - 525 Cochra

Your Facility Description:



Configuration
1. Warehouse, Electricity (Constant Volume) - 68.5%
2. Office, Small, Electric (Variable Volume) - 31.5%
Total Floor Area: 590 m
Location: Toronto (A), Ontario

Utility Rates
Your marginal utility rates (including any taxes and fees):
$ 0.035 per kWh $ 11.000 per GJ
$ 8.500 per kW $ 11.000 per litre oil/propane

First Building Block


First Building Block: Warehouse, 450 m
Heating System: Electricity (Constant Volume)

Building Shell (Warehouse)


Reference Your
Building Design
Average window-to-wall-area ratio: 2.21 2.21 %
Overall window USI-value: 2.1 5.1 W/mC
Window shading coefficient: 0.74 1
Overall wall RSI-value: 3.03 2.09 mC/W
Gross exterior wall area: 718 718 m

http://screeningtool.ca/cgi-bin/summary1.cgi 8/14/2017
Screening Tool For New Building Design Page 2 / 6

Roof type: Trusses & Trusses &


joists joists
Overall roof RSI-value: 4.348 4
Gross exterior roof area: 450 450 m

Mechanical System (Warehouse)


Reference Your
Building Design
Heating efficiency: 100 70 %
Minimum outside air: 0.25 0.25 l/s/m
Demand control ventilation (DCV) type: None None
Percent of outside air controlled by DCV: 0 0%
Percent of floor area cooled: 80 80 %
Cooling efficiency: 2.5 2.5 COP
Outdoor air economizer? Yes Yes
Efficiency of exhaust air heat recovery: 0 0%
Service water heating fuel type: Electric Electric
Service water heating efficiency: 100 70 %
Service water savings: 0 0%
Mechanical Efficiency Options (only applies to Your Design):
Variable speed fans: Yes

Lighting (Warehouse)
Reference Your
Building Design
Average lighting density: 6 6 W/m
Lighting controls (select if applicable and enter floor area):
None 0%
None 0%

Process Loads (Warehouse)


Reference Your
Building Design
Average process load density: 0 0
Percent served by electricity: 0 0%

Second Building Block


Second Building Block: Office, Small, 186 m

http://screeningtool.ca/cgi-bin/summary1.cgi 8/14/2017
Screening Tool For New Building Design Page 3 / 6

Heating System: Electric (Variable Volume)

Building Shell (Office, Small)


Reference Your
Building Design
Average window-to-wall-area ratio: 24.63 24.63 %
Overall window USI-value: 2.1 5.1 W/mC
Window shading coefficient: 0.736 1
Overall wall RSI-value: 3.03 2 mC/W
Gross exterior wall area: 223 223 m
Trusses & Trusses &
Roof type:
joists joists
Overall roof RSI-value: 4.348 4
Gross exterior roof area: 93 93 m

Mechanical System (Office, Small)


Reference Your
Building Design
Heating efficiency: 100 70 %
Minimum outside air: 0.25 0.25 l/s/m
Demand control ventilation (DCV) type: None None
Percent of outside air controlled by DCV: 0 0%
Percent of floor area cooled: 80 80 %
Cooling efficiency: 3.8 2.5 COP
Outdoor air economizer? Yes Yes
Efficiency of exhaust air heat recovery: 0 0%
Service water heating fuel type: Electric Electric
Service water heating efficiency: 100 70 %
Service water savings: 0 0%
Mechanical Efficiency Options (only applies to Your Design):
Variable speed fans: Yes

Lighting (Office, Small)


Reference Your
Building Design
Average lighting density: 18 20.45 W/m
Lighting controls (select if applicable and enter floor area):
None 0%

http://screeningtool.ca/cgi-bin/summary1.cgi 8/14/2017
Screening Tool For New Building Design Page 4 / 6

None 0%

Process Loads (Office, Small)


Reference Your
Building Design
Average process load density: 0 0
Percent served by electricity: 0 0%

Building Performance Results

Based on the information you provided, your building design is not 25% more
energy efficient than the reference building that meets the Model National
Energy Code for Buildings.

Current Design Performance

Annual Energy Use (GJ)


Reference Building 424
Your Design 749

Energy Savings -325 -76.5%

Annual Energy Cost Savings $-6,223.45

LEED Canada 1.0 Energy & Atmosphere (EA)


Does not qualify (EA Prerequisite 2 is not
satisfied)

Emissions Savings
Carbon Dioxide (CO2) -48,845 kg

Annual Energy Use Comparison

http://screeningtool.ca/cgi-bin/summary1.cgi 8/14/2017
Screening Tool For New Building Design Page 5 / 6

Your Design

Annual Energy and Costs


Electricity Fossil Fuel Total Energy
End Use Costs
kWh GJ GJ
Cooling 21,699 0 78 $2,321
Heating 137,603 0 495 $9,961
Lights 18,067 0 65 $1,061
Equip. 6,345 0 23 $357
Aux. 22,869 0 82 $1,793
SWH 1,368 0 5 $87
Totals 207,951 0 749 $15,580

Reference Building

Annual Energy and Costs


Electricity Fossil Fuel Total Energy
End Use Costs
kWh GJ GJ
Cooling 13,843 0 50 $1,302
Heating 53,232 0 192 $4,907
Lights 16,725 0 60 $935
Equip. 6,345 0 23 $347
Aux. 26,695 0 96 $1,806
SWH 957 0 3 $60

http://screeningtool.ca/cgi-bin/summary1.cgi 8/14/2017
Screening Tool For New Building Design Page 6 / 6

Totals 117,797 0 424 $9,356

Disclaimer
The information presented on this web page gives approximate values of energy cost breakdowns and
potential savings. Because the input data are not as detailed as required under the MNECB or LEED,
actual results will vary. A number of factors, such as weather variations, building occupancy, other
building configurations, and operation schedules, also can affect energy usage and, consequently,
energy performance and savings. Therefore, we cannot guarantee that the building will perform as
indicated.