You are on page 1of 7

TECHNICAL SITE SURVEY REPORT

(TSSR)

SITE ID :___MW5903_____

SITE NAME :___NKHORONGO___

Jun. 2014
3G SITE SURVEY SHEET

Site Name Nkhorogo No MW5903 Date 12-08-2014


Location Town Mzuzu
Site Type Airtel
Site Type Greenfield Rooftop Existing Structure Indoor Outdoor VDM Build Cell C Upgrade
GPS Position Measured During Survey Latitude S 11.391651 Longitude E 33.989855

ACCESS INFORMATION
Contact Person Number
Substitute Number
Access Days 12-08-2014 Access road Good Bad Very bad
Notes

TOWER N/A Existing New Tower Height 55 m


Antenna Height (2G) 27m
Antenna Azimuth (2G) A Sector 20 B Sector 130 C Sector 240
Microwave Height 43m
Tower Type Monopole Concrete Mono Pole Lattice Stub Enviro Spec Signboard Round pole
Other
Type of Loading Required Urban Rural Environ Strategic Rooftop/Stub
Terrain Category flat Tower Category .
Aviation Lights Motivated Metro Rural Paint Yes No Colour red and white
Notes

EQUIPMENT SHELTER
N/A New Existing
Shelter Type N/A Isotherm Special
Equipment Space Available Unavailable
Cable Tray Space Available Unavailable
Size 2.4x2.8 2.4x2.4 2.0x2.0 Other 2.5*4.5
Feeder Entry Plate Existing New
Notes

OUTDOOR FOUNDATION
N/A New Existing Renovate
Concret base 2 m by 3 m
Notes

1
RF&RRU INSTALLATION
A Sector Jump cable size 1/2 Jump cable length 2m Qty 2
B Sector Jump cable size 1/2 Jump cable length 2m Qty 2
C Sector Jump cable size 1/2 Jump cable length 2m Qty 2
A Sector RRU mounting height 45m Fiber &DC Cable length 60m Qty 2
B Sector RRU mounting height 45m Fiber &DC Cable length 60m Qty 2
C Sector RRU mounting height 45m Fiber &DC Cable length 60m Qty 2
Ant Information
Proposal 3G Antenna Height 45m
Available free space range_______ (43-48)m_______________
Proposal Antenna Azimuth A Sector 20 B Sector 130 C Sector 240
Existing 2G Antenna type V-pole X-pole H-Frame
H-Frame New Existing
Antenna Pole Yes No Qty 3 Length 2 m
Transmission Type Tie Cable Cable Microwave Satelite
Trunking (75x50) N/A PVC Steel Length 11m Paint Yes No Colour .
Antenna Mount Wall Mount Floor Mount Pole Mount
Access Workman Cage Platform Scaffolding Cherry Ricker Abseiling
Notes

DC INFORMATION
Existing Rec. Model Existing Capacity 2.4KVA
Output Voltage +24V -48V
Existing circuit Breaker Detail:
Breaker Available Unavailable Capacity 32A
Note:

First to shut down _______63*3+10*4+6*4____________________________________________


Second to shut down _________________________________________________________
Battery:
Battery Supplier/Type Existing Capacity (2V,588AH)*24 Group 1
Notes

2
SURVEY PHOTOS
The photo for Existing Tower

The position for 3G RRU& ANT.

The photo for site environment

3
The photo
for Site
location.

4
The photo
for existing
room
location or
outside
equipments

The photo
for Existing
DC.

5
The photo
for the space
for New
Equipment.

The photo
for access
road

You might also like