You are on page 1of 30

DISEO POR FUERZA CORTANTE DE VIGAS PRINCIPALES

VIGAS PRINCIPALES DEL PRIMER NIVEL

DATOS: VP1 & VP7


fc= 210.00Kg/cm2
fy= 4200.00Kg/cm2
PL= 1.800tn/m
PD= 4.150tn/m 60.00cm
L= 7.200m

30.00cm

Wu= 8.870tn/m

7.20m

Diagrama de fuerza cortante

31.93tn

3.60m
3.60m

31.93tn

peralte efectivo(d)= 54.00cm

Vc=0.53()*b*d Vc= 12442.30Kg


Vc= 12.44tn
Vc/2= 6.22tn

Vn= = 0.85
/ Vn= 37.57tn

SI Vn tenemos: 37.57tn > 12.44tn


37.57tn

Vnd

12.44tn
no necesita Av
6.22tn
m= 0.60m

0.54m
m

3.60m
3.00m

Vnd= 31.93tn

Vnd=+
Vs= 19.49tn

Vs2=1.06()
Vs2= 24.88tn

S<d/2 y Smax<60cm d/2= 27.00cm


d/4= 13.50cm

acero area
3/8 0.71cm2 0.60m
Av= 1.42cm2

0.60m
1.19m

S=(
)/ S= 16.52cm
S= 16.50cm
# de estribos

#Av= 18.21
#Av= 18.00 3/8

Por condicion sismica


nucleo confinado

col 1@5,2@10 = 25.00cm


viga

275.00cm
# de estribos
#Av= 16.00 estribos fuera de la zona del nucleo confinado
total de #Av= 19.00

Avmin=(3.5 S=( S= 56.80cm


)/ )/(3.5) Smax= 27.00cm

Podemos tomar valores de S: 15.00cm 20.00cm 25.00cm


asumendo S= 20.00cm

S=( Vs=(
Vs= 16102.80Kg
)/ )/ Vs= 16.10tn

Vn=+
37.57tn
Vn= 28.55tn
Vn
12.44tn n= 2.70m
16.10tn

n
3.60m
0.90m

90.00cm -
25.00cm
65.00cm #Av= 4 3/8 @ 20cm

300.38cm -
25.00cm
90.00cm
185.00cm #Av= 11 3/8 16.5cm

USAR: 3/8:

1@5cm, 2@10cm, 11 @ 17cm , 4 @ ### resto@25cm A/E


DISEO POR FUERZA CORTANTE DE VIGAS PRINCIPALES

VIGAS PRINCIPALES DEL PRIMER NIVEL

DATOS: VP2 AL VP6


fc= 210.00Kg/cm2
fy= 4200.00Kg/cm2
PL= 3.200tn/m
PD= 5.220tn/m 60.00cm
L= 7.200m

30.00cm

Wu= 12.748tn/m

7.20m

Diagrama de fuerza cortante

45.89tn

3.60m
3.60m

45.89tn

peralte efectivo(d)= 54.00cm

Vc=0.53()*b*d Vc= 12442.30Kg


Vc= 12.44tn
Vc/2= 6.22tn

Vn= = 0.85
/ Vn= 53.99tn

SI Vn tenemos: 53.99tn > 12.44tn


53.99tn

Vnd

12.44tn
no necesita Av
6.22tn
m= 0.41m

0.54m m

3.60m
3.19m

Vnd= 45.89tn

Vnd=+
Vs= 33.45tn

Vs2=1.06()
Vs2= 24.88tn

S<d/4 y Smax<30cm d/2= 27.00cm


d/4= 13.50cm

acero area
3/8 0.71cm2 0.41m
Av= 1.42cm2

0.41m
0.83m

S=(
)/ S= 9.63cm
S= 9.60cm
# de estribos

#Av= 33.18
#Av= 33.00 3/8

Por condicion sismica


nucleo confinado

col 1@5,2@10 = 25.00cm


viga

293.00cm
# de estribos
#Av= 30.00 estribos fuera de la zona del nucleo confinado
total de #Av= 33.00

Avmin=(3.5 S=( S= 56.80cm


)/ )/(3.5) Smax= 13.50cm

Podemos tomar valores de S: 10.00cm 12.00cm 13.00cm


asumendo S= 12.00cm

S=( Vs=(
Vs= 26838.00Kg
)/ )/ Vs= 26.84tn

Vn=+
53.99tn
Vn= 39.28tn
Vn
12.44tn n= 2.60m
26.84tn

n
3.60m
1.00m

100.00cm -
25.00cm
75.00cm #Av= 7 3/8 @ 12cm

318.52cm -
25.00cm
100.00cm
193.00cm #Av= 20 3/8 10cm

USAR: 3/8:

1@5cm, 2@10cm, 20 @ 10cm , 7 @ ### resto@25cm A/E


DISEO POR FUERZA CORTANTE DE VIGAS PRINCIPALES

VIGAS PRINCIPALES DEL PRIMER NIVEL

DATOS: VP1 & VP7 VOLADO


fc= 210Kg/cm2
fy= 4200Kg/cm2
PL= 1.000tn/m
PD= 2.200tn/m 45.00cm
L= 2.100m

30.00cm

Wu= 4.780tn/m

2.10m

Diagrama de fuerza cortante

10.04tn

2.10m

peralte efectivo(d)= 39.00cm

Vc=0.53()*b*d Vc= 8986.10Kg


Vc= 8.99tn
Vc/2= 4.49tn

Vn= = 0.85
/ Vn= 11.81tn

Vs=+ Vs= 2.82tn

acero area
S=(
3/8 0.71cm2 S= 82.38cm
)/
S=(
)/
Av= 1.42cm2

Vs1.06() = 17.97tn

S<d/2 cm y S<60 cm d/2= 19.5cm


d/4= 9.8cm
Usar estribos 3/8 @ 20.00cm

Seccion de refuerzo minimo


Vu= 10.04tn

Vn= 4.49tn
m= 1.30m
Vu= 3.82tn

m
2.10m

Avmin=(3.5 S=(
)/ )/ S= 56.80cm
(3.5)
Por condicion sismica
nucleo confinado
col
1@5,2@10 = 25.00cm
viga

130.10cm -
25.00cm
105.10cm

# de estribos

#Av= 6.00 3/8 @ 20.00cm

Longitud utilizada= 145.00cm

USAR: 3/8: 1@5cm, 2@10cm, 6 @ 20cm resto@30cm


@
DISEO POR FUERZA CORTANTE DE VIGAS PRINCIPALES

VIGAS PRINCIPALES DEL PRIMER NIVEL

DATOS: VP2 & VP VOLADO


fc= 210Kg/cm2
fy= 4200Kg/cm2
PL= 1.800tn/m
PD= 3.350tn/m 45.00cm
L= 2.100m

30.00cm

Wu= 7.750tn/m

2.10m

Diagrama de fuerza cortante

16.28tn

2.10m

peralte efectivo(d)= 39.00cm

Vc=0.53()*b*d Vc= 8986.10Kg


Vc= 8.99tn
Vc/2= 4.49tn

Vn= = 0.85
/ Vn= 19.15tn

Vs=+ Vs= 10.16tn

acero area
S=(
3/8 0.71cm2 S= 22.89cm
)/
S=(
)/
Av= 1.42cm2

Vs1.06() = 17.97tn

S<d/2 cm y S<60 cm d/2= 19.5cm


d/4= 9.8cm
Usar estribos 3/8 @ 20.00cm

Seccion de refuerzo minimo


Vu= 16.28tn

Vn= 4.49tn
m= 1.61m
Vu= 3.82tn

m
2.10m

Avmin=(3.5 S=(
)/ )/ S= 56.80cm
(3.5)
Por condicion sismica
nucleo confinado
col
1@5,2@10 = 25.00cm
viga

160.72cm -
25.00cm
135.72cm

# de estribos

#Av= 7.00 3/8 @ 20.00cm

Longitud utilizada= 165.00cm

USAR: 3/8: 1@5cm, 2@10cm, 7 @ 20cm resto@30cm


@
DISEO POR FUERZA CORTANTE DE VIGAS SECUNDARIAS

VIGAS PRINCIPALES DEL PRIMER NIVEL

DATOS: VS1 & VS6


fc= 210.00Kg/cm2
fy= 4200.00Kg/cm2
PL= 2.500tn/m
PD= 5.120tn/m 35.00cm
L= 3.780m

25.00cm

Wu= 11.418tn/m

3.78m

Diagrama de fuerza cortante

21.58tn

1.89m
1.89m

21.58tn

peralte efectivo(d)= 29.00cm

Vc=0.53()*b*d Vc= 5568.31Kg


Vc= 5.57tn
Vc/2= 2.78tn

Vn= = 0.85
/ Vn= 25.39tn

SI Vn tenemos: 25.39tn > 5.57tn


25.39tn

Vnd

5.57tn
no necesita Av
2.78tn
m= 0.21m

0.29m m

1.89m
1.68m

Vnd= 21.49tn

Vnd=+
Vs= 15.92tn

Vs2=1.06()
Vs2= 11.14tn

S<d/4 y Smax<30cm d/2= 14.50cm


d/4= 7.25cm

acero area
3/8 0.71cm2 0.21m
Av= 1.42cm2

0.21m
0.41m

S=(
)/ S= 10.86cm
S= 10.80cm
# de estribos

#Av= 15.58
#Av= 15.00 3/8

Por condicion sismica


nucleo confinado

col 1@5,2@10 = 25.00cm


viga

143.00cm
# de estribos
#Av= 13.00 estribos fuera de la zona del nucleo confinado
total de #Av= 16.00

Avmin=(3.5 S=( S= 68.16cm


)/ )/(3.5) Smax= 14.50cm

Podemos tomar valores de S: 15.00cm 20.00cm 25.00cm


asumendo S= 20.00cm

S=( Vs=(
Vs= 8647.80Kg
)/ )/ Vs= 8.65tn

Vn=+
25.39tn
Vn= 14.22tn
Vn
5.57tn n= 1.00m
8.65tn

n
1.89m
0.89m

89.00cm -
25.00cm
64.00cm #Av= 4 3/8 @ 20.0cm

168.27cm -
25.00cm
89.00cm
54.00cm #Av= 5 3/8 10.8cm

USAR: 3/8:

1@5cm, 2@10cm, 5 @ 11cm , 4 @ ### resto@25cm A/E


DISEO POR FUERZA CORTANTE DE VIGAS SECUNDARIAS

VIGAS PRINCIPALES DEL PRIMER NIVEL

DATOS: VS2 AL VS5


fc= 210.00Kg/cm2
fy= 4200.00Kg/cm2
PL= 2.550tn/m
PD= 5.170tn/m 35.00cm
L= 3.800m

25.00cm

Wu= 11.573tn/m

3.80m

Diagrama de fuerza cortante

21.99tn

1.90m
1.90m

21.99tn

peralte efectivo(d)= 29.00cm

Vc=0.53()*b*d Vc= 5568.31Kg


Vc= 5.57tn
Vc/2= 2.78tn

Vn= = 0.85
/ Vn= 25.87tn

SI Vn tenemos: 25.87tn > 5.57tn


25.87tn

Vnd

5.57tn
no necesita Av
2.78tn
m= 0.20m

0.29m m

1.90m
1.70m

Vnd= 21.92tn

Vnd=+
Vs= 16.35tn

Vs2=1.06()
Vs2= 11.14tn

S<d/4 y Smax<30cm d/2= 14.50cm


d/4= 7.25cm

acero area
3/8 0.71cm2 0.20m
Av= 1.42cm2

0.20m
0.41m

S=(
)/ S= 10.58cm
S= 10.50cm
# de estribos

#Av= 16.15
#Av= 16.00 3/8

Por condicion sismica


nucleo confinado

col 1@5,2@10 = 25.00cm


viga

144.00cm
# de estribos
#Av= 13.00 estribos fuera de la zona del nucleo confinado
total de #Av= 16.00

Avmin=(3.5 S=( S= 68.16cm


)/ )/(3.5) Smax= 14.50cm

Podemos tomar valores de S: 15.00cm 20.00cm 25.00cm


asumendo S= 20.00cm

S=( Vs=(
Vs= 8647.80Kg
)/ )/ Vs= 8.65tn

Vn=+
25.87tn
Vn= 14.22tn
Vn
5.57tn n= 1.00m
8.65tn

n
1.90m
0.90m

90.00cm -
25.00cm
65.00cm #Av= 4 3/8 @ 20.0cm

169.55cm -
25.00cm
90.00cm
54.00cm #Av= 5 3/8 10.5cm

USAR: 3/8:

1@5cm, 2@10cm, 5 @ 11cm , 4 @ ### resto@25cm A/E


DISEO POR FUERZA CORTANTE DE VIGAS SECUNDARIAS

VIGAS PRINCIPALES DEL PRIMER NIVEL

DATOS: VS7 & VS12


fc= 210.00Kg/cm2
fy= 4200.00Kg/cm2
PL= 2.900tn/m
PD= 5.552tn/m 35.00cm
L= 3.780m

25.00cm

Wu= 12.703tn/m

3.78m

Diagrama de fuerza cortante

24.01tn

1.89m
1.89m

24.01tn

peralte efectivo(d)= 29.00cm

Vc=0.53()*b*d Vc= 5568.31Kg


Vc= 5.57tn
Vc/2= 2.78tn

Vn= = 0.85
/ Vn= 28.25tn

SI Vn tenemos: 28.25tn > 5.57tn


28.25tn

Vnd

5.57tn
no necesita Av
2.78tn
m= 0.19m

0.29m m

1.89m
1.70m

Vnd= 23.91tn

Vnd=+
Vs= 18.34tn

Vs2=1.06()
Vs2= 11.14tn

S<d/4 y Smax<30cm d/2= 14.50cm


d/4= 7.25cm

acero area
3/8 0.71cm2 0.19m
Av= 1.42cm2

0.19m
0.37m

S=(
)/ S= 9.43cm
S= 9.40cm
# de estribos

#Av= 18.12
#Av= 18.00 3/8

Por condicion sismica


nucleo confinado

col 1@5,2@10 = 25.00cm


viga

145.00cm
# de estribos
#Av= 15.00 estribos fuera de la zona del nucleo confinado
total de #Av= 18.00

Avmin=(3.5 S=( S= 68.16cm


)/ )/(3.5) Smax= 14.50cm

Podemos tomar valores de S: 15.00cm 20.00cm 25.00cm


asumendo S= 20.00cm

S=( Vs=(
Vs= 8647.80Kg
)/ )/ Vs= 8.65tn

Vn=+
28.25tn
Vn= 14.22tn
Vn
5.57tn n= 0.90m
8.65tn

n
1.89m
0.99m

99.00cm -
25.00cm
74.00cm #Av= 4 3/8 @ 20.0cm

170.37cm -
25.00cm
99.00cm
46.00cm #Av= 5 3/8 9.4cm

USAR: 3/8:

1@5cm, 2@10cm, 5 @ 9cm , 4 @ ### resto@25cm A/E


DISEO POR FUERZA CORTANTE DE VIGAS SECUNDARIAS

VIGAS PRINCIPALES DEL PRIMER NIVEL

DATOS: VS8 & VS11


fc= 210.00Kg/cm2
fy= 4200.00Kg/cm2
PL= 3.200tn/m
PD= 6.230tn/m 35.00cm
L= 3.800m

25.00cm

Wu= 14.162tn/m

3.80m

Diagrama de fuerza cortante

26.91tn

1.90m
1.90m

26.91tn

peralte efectivo(d)= 29.00cm

Vc=0.53()*b*d Vc= 5568.31Kg


Vc= 5.57tn
Vc/2= 2.78tn

Vn= = 0.85
/ Vn= 31.66tn

SI Vn tenemos: 31.66tn > 5.57tn


31.66tn

Vnd

5.57tn
no necesita Av
2.78tn
m= 0.17m

0.29m m

1.90m
1.73m

Vnd= 26.82tn

Vnd=+
Vs= 21.26tn

Vs2=1.06()
Vs2= 11.14tn

S<d/4 y Smax<30cm d/2= 14.50cm


d/4= 7.25cm

acero area
3/8 0.71cm2 0.17m
Av= 1.42cm2

0.17m
0.33m

S=(
)/ S= 8.14cm
S= 8.10cm
# de estribos

#Av= 21.39
#Av= 21.00 3/8

Por condicion sismica


nucleo confinado

col 1@5,2@10 = 25.00cm


viga

148.00cm
# de estribos
#Av= 18.00 estribos fuera de la zona del nucleo confinado
total de #Av= 21.00

Avmin=(3.5 S=( S= 68.16cm


)/ )/(3.5) Smax= 14.50cm

Podemos tomar valores de S: 15.00cm 20.00cm 25.00cm


asumendo S= 20.00cm

S=( Vs=(
Vs= 8647.80Kg
)/ )/ Vs= 8.65tn

Vn=+
31.66tn
Vn= 14.22tn
Vn
5.57tn n= 0.80m
8.65tn

n
1.90m
1.10m

110.00cm -
25.00cm
85.00cm #Av= 5 3/8 @ 20.0cm

173.29cm -
25.00cm
110.00cm
38.00cm #Av= 5 3/8 8.1cm

USAR: 3/8:

1@5cm, 2@10cm, 5 @ 8cm , 5 @ ### resto@25cm A/E


DISEO POR FUERZA CORTANTE DE VIGAS SECUNDARIAS

VIGAS PRINCIPALES DEL PRIMER NIVEL

DATOS: VS13 & VS18 VOLADO


fc= 210.00Kg/cm2
fy= 4200.00Kg/cm2
PL= 0.900tn/m
PD= 1.720tn/m 25.00cm
L= 3.780m

25.00cm

Wu= 3.938tn/m

3.78m

Diagrama de fuerza cortante

7.44tn

1.89m
1.89m

7.44tn

peralte efectivo(d)= 19.00cm

Vc=0.53()*b*d Vc= 3648.20Kg


Vc= 3.65tn
Vc/2= 1.82tn

Vn= = 0.85
/ Vn= 8.76tn

SI Vn tenemos: 8.76tn > 3.65tn


8.76tn

Vnd

3.65tn
no necesita Av
1.82tn
m= 0.39m

0.19m m

1.89m
1.50m

Vnd= 7.88tn

Vnd=+
Vs= 4.23tn

Vs2=1.06()
Vs2= 7.30tn

S<d/2 y Smax<60cm d/2= 9.50cm


d/4= 4.75cm

acero area
3/8 0.71cm2 0.39m
Av= 1.42cm2

0.39m
0.79m

S=(
)/ S= 26.80cm
S= 26.80cm
# de estribos

#Av= 5.58
#Av= 5.00 3/8

Por condicion sismica


nucleo confinado

col 1@5,2@10 = 25.00cm


viga

124.00cm
# de estribos
#Av= 4.00 estribos fuera de la zona del nucleo confinado
total de #Av= 7.00

Avmin=(3.5 S=( S= 68.16cm


)/ )/(3.5) Smax= 9.50cm

Podemos tomar valores de S: 15.00cm 20.00cm 25.00cm


asumendo S= 20.00cm

S=( Vs=(
Vs= 5665.80Kg
)/ )/ Vs= 5.67tn

Vn=+
8.76tn
Vn= 9.31tn
Vn
3.65tn n= 2.00m
5.67tn

n
1.89m
-0.11m

-11.00cm -
25.00cm
-36.00cm #Av= -2 3/8 @ 20.0cm

149.63cm -
25.00cm
-11.00cm
135.00cm #Av= 5 3/8 22.0cm

USAR: 3/8:

1@5cm, 2@10cm, 5 @ 22cm , resto@25cm A/E


DISEO POR FUERZA CORTANTE DE VIGAS SECUNDARIAS

VIGAS PRINCIPALES DEL PRIMER NIVEL

DATOS: VS14 & VS17 VOLADO


fc= 210.00Kg/cm2
fy= 4200.00Kg/cm2
PL= 0.950tn/m
PD= 1.813tn/m 25.00cm
L= 3.800m

25.00cm

Wu= 4.153tn/m

3.80m

Diagrama de fuerza cortante

7.89tn

1.90m
1.90m

7.89tn

peralte efectivo(d)= 19.00cm

Vc=0.53()*b*d Vc= 3648.20Kg


Vc= 3.65tn
Vc/2= 1.82tn

Vn= = 0.85
/ Vn= 9.28tn

SI Vn tenemos: 9.28tn > 3.65tn


9.28tn

Vnd

3.65tn
no necesita Av
1.82tn
m= 0.37m

0.19m m

1.90m
1.53m

Vnd= 8.36tn

Vnd=+
Vs= 4.71tn

Vs2=1.06()
Vs2= 7.30tn

S<d/2 y Smax<60cm d/2= 9.50cm


d/4= 4.75cm

acero area
3/8 0.71cm2 0.37m
Av= 1.42cm2

0.37m
0.75m

S=(
)/ S= 24.07cm
S= 24.00cm
# de estribos

#Av= 6.36
#Av= 6.00 3/8

Por condicion sismica


nucleo confinado

col 1@5,2@10 = 25.00cm


viga

127.00cm
# de estribos
#Av= 5.00 estribos fuera de la zona del nucleo confinado
total de #Av= 8.00

Avmin=(3.5 S=( S= 68.16cm


)/ )/(3.5) Smax= 9.50cm

Podemos tomar valores de S: 15.00cm 20.00cm 25.00cm


asumendo S= 20.00cm

S=( Vs=(
Vs= 5665.80Kg
)/ )/ Vs= 5.67tn

Vn=+
9.28tn
Vn= 9.31tn
Vn
3.65tn n= 1.90m
5.67tn

n
1.90m
0.00m

0.00cm -
25.00cm
-25.00cm #Av= -2 3/8 @ 20.0cm

152.67cm -
25.00cm
0.00cm
127.00cm #Av= 5 3/8 22.0cm

USAR: 3/8:

1@5cm, 2@10cm, 5 @ 22cm , resto@25cm A/E