The document summarizes the basic parameters of three types of thermosyphon evaporators - INT, IKT, and IPT. Some key parameters that vary between the types are heat exchange surface area, housing inner diameter, temperature range of heated and evaporated medium, nominal operating pressures, heat exchange tube lengths, tube outer diameters and wall thicknesses, and number of strokes through each tube. Diagrams show the design and fluid flow paths for INT and IKT type evaporators.
The document summarizes the basic parameters of three types of thermosyphon evaporators - INT, IKT, and IPT. Some key parameters that vary between the types are heat exchange surface area, housing inner diameter, temperature range of heated and evaporated medium, nominal operating pressures, heat exchange tube lengths, tube outer diameters and wall thicknesses, and number of strokes through each tube. Diagrams show the design and fluid flow paths for INT and IKT type evaporators.
The document summarizes the basic parameters of three types of thermosyphon evaporators - INT, IKT, and IPT. Some key parameters that vary between the types are heat exchange surface area, housing inner diameter, temperature range of heated and evaporated medium, nominal operating pressures, heat exchange tube lengths, tube outer diameters and wall thicknesses, and number of strokes through each tube. Diagrams show the design and fluid flow paths for INT and IKT type evaporators.
From - 70 up to + 350 From - 70 up to + 450 evaporated medium (5), Nominal pressure, MPa, no more, in tubes of equipment of diameter, mm 1,6; 2,5; 4,0; 6,3 6001000 1,0; 1,6; 2,5 1,0; 1,6 1200 1400 1,0; 1,6; 2,5 16002000
2200 1,0; 1,6 In housing for equipment of diameter, mm 6001000 1,0; 1,6; 2,5; 4,0 1,6; 2,5 1,0; 1, 1200 1400 1,0; 1,6; 2,5 16002000
2200 1,0; 1,6 Heat exchange tubes length, mm for equipment of diameter, mm 6001000 2000; 3000; 4000 12002200 3000; 4000 3000; 6000 Outer diameter and wall thickness of heat exchange tube, mm 252 252; 252,5 Number of strokes through tube 1 2; 4; 6 Diagram and step of heat exchange tube installation at tube Diagram at tops of equiangular triangles. Step 32. plates, mm Figure 1. The evaporators of T and type design 1. Dy product enter (exit); Dy product enter; Dy exit of product steams.
Figure 2. The evaporators of and type design 2. Dy steams enter; Dy product enter; Dy exit of product stems; Dy exit of condensate.
95 TOP Refrigeration and Air Conditioning - Mechanical Engineering Multiple Choice Questions and Answers List - MCQs Preparation For Engineering Competitive Exams