You are on page 1of 56

APPENDIX 8

ELECTRICAL SYMBOLS

1 of 56
Table of Contents

1. Current Systems, System Configurations And Protective Conductors .................................................... 3


2. Screening, Enclosure And Medium ....................................................................................................... 5
3. Regulating Systems .............................................................................................................................. 6
4. Mechanical Controls............................................................................................................................. 7
5. Qualifying Symbols.............................................................................................................................. 8
6. Batteries, Semi-Conductors, Generators, Motors And Converters ........................................................ 10
7. Transformers, Reactors And Transductors........................................................................................... 12
8. Conductors, Lines And Cables ............................................................................................................ 15
9. Overhead Line And Cable Accessories................................................................................................ 20
10. Terminals, Connections And Contact Elements ................................................................................. 21
11. Resistors, Coils And Capacitors ........................................................................................................ 22
12. Relay Coils And Contacts ................................................................................................................. 23
13. Circuit Breakers, Contactors, Plugs, Sockets And Push Buttons......................................................... 26
14. Automatic Tripping Devices, Starting Equipment And Remote-Control Units.................................... 29
15. Switch-gear And Distribution Boxes ................................................................................................. 33
16. Protective Devices ............................................................................................................................ 34
17. Instruments And Metering Systems................................................................................................... 35
18. Lamp Fittings, Etc ............................................................................................................................ 38
19.Generating Stations And Substations (Planned).................................................................................. 41
20. Signaling Equipment And Clocks...................................................................................................... 42
21. Protection Relay Symbols ................................................................................................................. 43
21.1 Device Function Numbers, Indicating The Device Function Which Causes Relay Operate ....... 43
21.2 Device Function Numbers, Indicating The Device Function Which Causes Relay Operate ....... 45
21.3 Device Function Numbers, Indicating The Device Function Which Causes Relay Operate ....... 48
21.4 Device Function Numbers, Indicating The Device Function Which Causes Relay Operate ....... 50
22. Building Electrical Installation (Light Switches)................................................................................ 51
23. Electro Acoustic Elements ................................................................................................................ 54
24 Cathodic Protection ........................................................................................................................... 55
25. Hazardous Area Classification .......................................................................................................... 56

2 of 56
APPENDIX - 8

1. Current Systems, System Configurations And Protective


Conductors
E0101A IEC E0102 IEC E0103 IEC E0104 IEC

Direct Current (DC) Alternating current,


(AC) low freq. (power Alternating current, Alternating current, high
or sub audio freq.) medium freq. (audio or freq. (super audio, carrier
telephone freq.) and radio freq.)

E0105 IEC E0106 IEC E0107 IEC 63B1 IEC

Direct or alternating Rectified current with Alternating current of m Three conductors within
current (DC or AC) alternating component phases and frequency f one screen
symbol for equipment
for universal use

E0108 IEC E0109 IEC E0110 IEC E0111 IEC

One Winding Three separate windings m Separate Windings,


Three-phase winding,
T-Connected

E0112 IEC E0113 IEC E0114 IEC E0115 IEC

Two-phase winding Two-phase winding, Three-phase winding


Three-phase winding,
four wire V-Connected (60o) open-delta connected

3 of 56
E0116 IEC E0117 IEC E0118 IEC E0119 IEC

Three - phase winding, Three-phase winding, Three-phase winding, Star-delta winding


delta-connected three wire four wire, star- configuration
star-connected connected, with neutral
brought out.

E0120 IEC E0121 IEC E0122 IEC E0123 ZADCO

Six-phase winding,
Connection symbol, e.g. Three-phase winding, double-delta-connected
of a primary delta- three wire zig-zag or Three-phase winding,
secondary star- interconnected star four wire zig-zag or
connected, three-phase interconnected star, with
transformer with clock neutral brought out.
hour figure 11. Capital
letter for high voltage
winding
E0124 IEC E0125 IEC E0126 IEC E0127 IEC

Six-phase winding, Six-phase winding, Danger (high voltage) Place of breakdown or


polygon-connected star-connected
faults as used in short-
circuit calculations or
protective gear diagrams
E0128 IEC E0129 IEC E0130 IEC E0131 IEC

Supply DC System Supply DC System Earth (ground), general Protective earth


positive (ground)
Negative
Mid-Wire
E0132 IEC E0133 IEC E0134 IEC E0135 IEC

No Symbol

Protective conductor
and neutral conductor Noiseless (clean) Frame or chassis
combined earth (ground) Equipotentiality

4 of 56
APPENDIX - 8

2. Screening, Enclosure And Medium

E0201 IEC E0202A IEC E0203 IEC

Empty
Enclosure, general Boundary line (any
Screen (the screen may combination of short
be drawn in any and long strokes)
convenient shape)
E0204 IEC E0205 IEC E0206 IEC E0301 IEC

Liquid material Gaseous material Insulation material Variability, general


(non-inherent)

5 of 56
APPENDIX - 8

3. Regulating Systems

E0302 IEC E0303 IEC E0304 IEC E0305 IEC

Variability, pre-set Variability, inherent Variability, inherent,


non-linear Continuous variability
adjustment
E0306 IEC E0307 IEC E0308 IEC E0309 IEC

Variability in steps Variability, continuos Variability, variable in 8 Variability, inherently


steps automatic

6 of 56
APPENDIX - 8

4. Mechanical Controls

E0401A IEC E0401B IEC E0402 IEC E0403 IEC

A/ General symbol B/ For use in restricted Locking device, padlock Devices for restricted
space facility movement of a
mechanical link
(unblocked position)
E0404 IEC E0405 IEC E0406 IEC E0407 IEC

Devices for restricted Mechanical interlock Automatic return Non-automatic return


movement of a between two devices (e.g. spring return)
mechanical link
(unblocked position)
E0408 IEC E0409 IEC E0410 IEC E0411 IEC

Manually operated Manually operated Operated by pulling


Operated by pushing
control, general control with restricted
access
E0412 IEC E0413 IEC E0414 IEC E0415 IEC

Operated by turning Operated by hand-wheel Operated by pedal Operated by lever


E0416 IEC E0417 IEC E0418 IEC E0419 IEC

Operated by roller Operated by cam Operated by crank Operated by removable


handle

7 of 56
APPENDIX - 8

5. Qualifying Symbols

E0503 IEC E0504 IEC E0505 IEC E0506 IEC

Uni-directional rotation
Repeating 0 times Rectilinear force or Bi-directional in the direction of the
motion in the direction pectilinear force or arrow for example
of the arrow motion clockwise
E0507 IEC E0508 ZADCO E0509 ZADCO E0510 IEC

Bi-directional rotation
Start (on) Stop (off) Automatic release
limited in both
function
directions
E0511 IEC E0512 IEC E0513 IEC E0514 IEC

Light-operated arrow Temperature Permanent magnet Contactor function


pointing towards symbol dependence
light generating and/or
modulating arrows
pointing away from
symbols
E0515 IEC E0516 IEC E0517 IEC E0518 IEC

Disconnector (isolator) Switch-disconnector


Circuit breaker
function (isolating switch) Position switch function
function limit switch function

8 of 56
E0519 IEC E0520 IEC E0521 IEC E0522 IEC

Delayed action in the


direction of movement Spring return function Non-spring return Operating when the
from the arc towards its (stay put) function characteristic value is
center. (to be linked higher than the setting
with double line E0401 value
to the symbol of the
device)
E0523 IEC E0524 IEC E0525 IEC

Operating when the


Operating when the Operating when the
characteristics value is
characteristics value is characteristic value
lower than the setting
either higher than a becomes zero
value
given high setting or
lower than a given low
setting

9 of 56
APPENDIX - 8

6. Batteries, Semi-Conductors, Generators, Motors And


Converters

E0601 IEC E0602 IEC E0603 IEC E0604 IEC

Primary cell or
accumulator (the long
line represents the Battery of accumulators or Battery with tapping Semi-conductor diode
positive pole, the other primary cells
the negative)
E0605 IEC E0606 IEC E0607 IEC E0608 IEC

Bi-directional diode Breakdown diode, Breakdown diode, bi- Thyristor, general


(varistor) undirectional directional
E0609 IEC E0610 IEC E0611 IEC E0612 IEC

Reverse blocking Reverse blocking thyristor Bi-directional thyristor Transistor


thyristor n-gate (anode p-gate (cathode side PNP
side controlled) controlled)
E0613 IEC E0614 IEC E0615 IEC E0616 IEC

Machine capable of use Mechanically coupled


Transistor Machine general symbol. machines, general
The asterisk shall be as motor or generator,
NPN
replaced by a letter general
designation as follows:-
Motor(M), generator(G),
synchronous
Converter (c)

10 of 56
E0617 ZADCO E0618 IEC E0619 IEC E0620 IEC

Shunt winding or Series winding


Non rotary generator, Stator with two windings
separate winding
oscillator
E0621 IEC E0622 IEC E0623 IEC E0624 IEC

Commutating or
compensating winding Synchronous converter, Power converter, Rectifier, power
general general the arrow is converter AC/DC
optional
E0625 IEC E0626 IEC E0627 IEC E0628 IEC

DC Converter, power
Inverter, power Frequency changer, Static switch
converter DC/DC
converter DC/AC power converter f1/f2
E0629 IEC E0630 ZADCO E0631 IEC E0632 IEC

DC generator with Three - phase induction


Synchronous generator motor with squirrel -
permanent magnet Three phase induction
(GS) or synchronous cage rotor.
excitation motor with slip ring
motor (MS), three
rotor
phase, both leads of
each phase brought out
E0633 IEC

Three - phase induction


motor with squirrel -
cage rotor, all six
winding ends brought
out

11 of 56
APPENDIX - 8

7. Transformers, Reactors And Transductors


E0701 IEC E0702 IEC E0703 IEC E0704 IEC

Choke reactor, inductor, Ferro-magnetic core, Ferro-magnetic core Winding of a


winding general with air gap, general transformer, general
multi - line
representation
E0705 IEC E0706 IEC E0707 IEC E0708 IEC

Transformer, single
phase with two separate Transformer with two
Transformer, single Transformer with two tappings single phase
phase with two separate windings multi line
tappings single phase multi line representation
windings simplified representation
simplified single line
single line representation
representation
E0709 IEC E0710 IEC E0711 IEC E0712 IEC

Inductor (reactor) with


Auto-transformer, single Auto-transformer, single Choke reactor, inductor, Ferro-magnetic core
phase simplified single- phase multi line winding simplified unless otherwise
line representation representation single - line indicated, general
representation multi line representation
E0713 IEC E0714 IEC E0715 IEC E0716 IEC

Induction regulator, Current transformer,


Induction regulator, Current transformer,
single phase multi-line general multi line
single phase simplified general simplified single
representation representation
single - line line representation
representation

12 of 56
E0717 IEC E0718 IEC E0719 IEC E0720 IEC

Current transformer Current transformer


with two secondary with two secondary Current transformer
windings on one core windings on one core Current transformer with two cores multi
simplified single line multi line representation with two cores line representation
representation simplified single line
representation
E0721 IEC E0722 IEC E0723 IEC E0724 IEC

Voltage transformer Voltage transformer, Transductor winding, Transductor core


simplified single line multi line representation general
representation
E0725 IEC E0726 IEC E0727 IEC E0728 IEC

Current transformer,
Transformer with off- where the primary
Transformer with off- Current transformer,
voltage tap changer, conductor forms five
voltage tap changer, where the primary
three-phase winding turns simplified
three phase conductor forms five
single line
winding turns multi line
representation
representation
E0729 IEC E0730 IEC E0736 ZADCO E0737 IEC

Current transformer Current transformer


with three primary Current transformer Current transformer
with three primary surrounding three surrounding three
windings simplified conductors (core
single line windings multi line conductors (core
representation balance) simplified balance) multi line
representation single line representation
representation

13 of 56
E0731 IEC E0732 IEC E0733 IEC E0734 IEC

Current transformer, Transductor element in Zig-Zag transformer


with one secondary Current transformer,
with one secondary assembled
tapping (three leads representation
brought out) simplified tapping (three leads
single - line brought out) multi line
representation representation
E0735 IEC

Tertiary winding
transformer

14 of 56
APPENDIX - 8

8. Conductors, Lines And Cables

E0801 IEC E0802 IEC E0803 IEC E0804 IEC

Conductor or group of
General symbol Conductors (n ) within Flexible conductor
conductors, general one screen
denoting screening of
conductors
E0805 IEC E0806 IEC E0807 IEC E0808 IEC

General symbol Conductors (n )


denoting twisting of twisted General symbol Conductors (n ) within
conductors denoting cable one cable
E0810 IEC E0811 IEC E0812 IEC

Empty
Underground line Line mounted in sight
Line not mounted in
sight
E0813 IEC E0814 IEC E0815 IEC E0816 IEC

Submarine line Conductors in conduit Neutral conductor Earthed conductor


E0817 IEC E0818 IEC E0819 IEC E0820 IEC

Earthed metallic screen Conductors, crossing Junction of conductors Double junction of


without electrical conductors
connection

15 of 56
E0821 IEC E0822 IEC E0823 IEC E0824 IEC

Common connection to Test point indicator


a group of apparatus Conductor joint, in line Method of indicating
(e.g. multipled or splice conductors data if the
looped) marked wires lie in one
cable bundle or circuit
E0825 IEC E0826 IEC E0827 IEC E0828 IEC

Method of indicating Method of indicating Conductors dividing Conductors dividing


data for each separate data for each separate
wire or cable in one wire or cable if more
bundle or channel than one cable is
represented by one line
E0829 IEC E0830 IEC E0831 IEC E0832 IEC

Conductors dividing Bundle of wires or Bundle of wires or Bundle of wires or


cables cables, crossing cables, dividing
E0833 IEC E0834 IEC E0835 IEC

Empty

Wiring or conductor Wiring or conductor


Wiring or conductor passing through
going downwards
going upwards vertically

16 of 56
E0839 IEC E0840 IEC

Empty Empty
Coaxial pair, general
Coaxial pair with outer
conductor connected to
earth
E0841 IEC E0842 IEC E0843 IEC E0844 IEC

Coaxial pair with screen End of coaxial Conductor or cable not Conductor or cable not
conductor connected connected and
especially insulated
E0845 IEC E0846 IEC E0847 IEC E0848 IEC

Four separate circuits or Three phase circuit 50 Three phase circuit 50


Three phase circuit 50
conductors Hz three conductors of Hz three conductors of
Hz three conductors of
120mm2 and neutral of
120mm2 and neutral of 120mm2 and neutral of
50mm2 for multi-line
50mm2 single -line 50mm2 for multi-line
representation
representation representation
E0849 IEC E0850 IEC E0851 IEC E0852 ZADCO

Coaxial socket Coaxial plug


Earth bar Main plant earth
electrode
E0853 ZADCO E0854 ZADCO E0855 ZADCO E0856 ZADCO

Equipment frame earth Earth cable on surface


connection Earth cable branch
Supplementary earth connection
electrode

17 of 56
E0857 ZADCO E0858 ZADCO E0859 ZADCO E0860 ZADCO

Conduit laid in floor Conduit run on surface Conduit concealed in Cable run on surface
screed slab
E0861 ZADCO E0862 ZADCO E0863 ZADCO E0864 ZADCO

Elect./Inst./Telecom.
Micc cable run on Cable tray G.I / PVC trunking cable in under ground
surface PVC duct
E0865 ZADCO E0866 ZADCO E0867 ZADCO E0868 ZADCO

Under ground earth Under ground earth Earth cable in concrete Earth cable in concrete
cable in excavated cable in excavated trench (existing) trench (proposed)
trench (Existing) trench (proposed)
E0869 ZADCO E0870 ZADCO E0871 ZADCO E0872 ZADCO

Elect../Inst./Telecom. Elect./Inst./Telecom. Elect./Inst./Telecom. Elect./Inst./Telecom.


under ground cable in under ground cable in cable in concrete trench cable in concrete trench
excavated trench excavated trench (existing) (proposed)
(existing) (proposed)
E0873 IEC E0874 IEC E0875 IEC E0876 IEC

Three-phase wiring with


Neutral conductor Protective conductor Combined protective neutral conductor and
and neutral conductor protective conductor

18 of 56
E0877 IEC E0878 IEC E0879 IEC E0880 IEC

Three-phase
or three conductors Single-phase and neutral Two-phase or two
Three-phase and neutral conductors
or single conductor and
or three conductors and
neutral
neutral

19 of 56
APPENDIX - 8

9. Overhead Line And Cable Accessories

E0910 ZADCO E0911 ZADCO E0912 IEC

Empty

Conduit entry Stuffing gland Straight-through joint


box underground
E0913 IEC E0914 IEC E0915 IEC E0916 IEC

Junction for three cables Junction for four cables Cable sealing end box
underground underground Branching box (e.g.
with four outlets)

20 of 56
APPENDIX - 8

10. Terminals, Connections And Contact Elements

E1001 IEC E1002 IEC E1003 IEC E1004 ZADCO

Terminal strip
Terminal connections of Terminal connections of Connection link with
conductors, general conductors, general bolted contacts
moveable contact
hinged
E1005A IEC E1005B IEC E1006 IEC E1007 ZADCO

Connecting link, closed Connecting link, open Brush on commuter or Draw-out representation
slip ring of switch-gear
accessories
E1005A IEC

Mated Plug and socket

21 of 56
APPENDIX - 8

11. Resistors, Coils And Capacitors

E1101 IEC E1102 IEC E1103 IEC E1104 IEC

Resistor with fixed Inductor, coil, winding,


Resister Shunt
tappings choke
E1105 IEC E1106 IEC E1107 IEC E1108 IEC

Capacitor, capacity, Polarized capacitor, Polarized electrolytic Non-polarized


general general capacitor electrolytic capacitor
E1109 IEC E1110 IEC E1111 IEC E1111 IEC

Chasis capacitor Feed through capacitor Code letters, indicating 2. Reactance


type of impedance
1 impedance
E1111 IEC E1111 IEC E1112 IEC E1113 ADC O

4. Resistance Variable resistor Variable resistor with


3. Self inductance
inherent non-linear
character
E1114 IEC E1115 IEC E1116 IEC E1117 IEC

Resistor with inherent Resistor with inherent non- Resistor with sliding
non-linear character linear character contact Shunt / series capacitor

22 of 56
APPENDIX - 8

12. Relay Coils And Contacts

E1201 IEC E1202 IEC E1203 IEC E1204 IEC

CON= Contactor Relay coil with one Relay coil with two
Non-inductive winding
IR = Interposing winding windings, separate
(bifilar)
Relay representation
CC = Closing coil
TC = Tripping Coil
K= Re-
Acceleration
E1205 IEC E1206 IEC E1207 IEC E1208 IEC

Relay coil of a very


Relay coil of a remnant Relay coil of a slow Relay coil of slow-
slow-releasing relay
relay releasing relay operating relay
E1209 IEC E1210 IEC E1211 IEC E1212 IEC

Relay coil of a very slow Relay coil of a Relay coil of an AC


Relay coil of a high-speed
operating relay polarized relay relay
relay (fast-operating and
releasing)
E1213 IEC E1214 IEC E1215 IEC E1216 IEC

Relay coil of a relay un- Relay coil of a Relay coil of an Relay coil of a slow-
affected by alternating mechanically latched relay impulse, sequence operating and slow
current relay releasing relay

23 of 56
E1217 IEC E1218 IEC E1219 IEC E1220 IEC

Actuating device for a Make contact Break contact Change over contact,
thermal relay(e.g. break before make
thermal overload relay)
E1221 IEC E1222 IEC E1223 IEC E1224 IEC

Change over contact, Contact with two breaks Contact with two
make before break Two way contact with
breaks
center-off position
E1225 IEC E1226 IEC E1227 IEC E1228 IEC

Two-way contact with Passing make contact


center-off position with Passing make contact Passing make contact
closing momentarily when closing momentarily
spring return from the its operating device is closing momentarily
left-hand position, but when its operating when its operating
actuated device is actuated or
not from the right-hand device is released
one (stay put) released
E1229 IEC E1230 IEC E1231 IEC E1232 IEC

Make contact (of a Break contact


Make contact (of a Break contact (of a
multiple contact (of a multiple contact
multiple contact assembly) multiple contact
assembly) which is early assembly) which is
which is late to operate assembly) which is late
to operate relative to the early to operate relative
relative to the other to operate relative to
other contacts of the to the other contacts of
contacts of the assembly the other contacts of
assembly the assembly
the assembly
E1233 IEC E1234 IEC E1235 IEC E1236 ZADCO

Flasher, operated by an Break contact delayed


actuating device of a Make contact delayed Break contact delayed
when closing when closing when opening
thermal relay

24 of 56
E1236A ZADCO E1237 IEC E1238 IEC E1239 ZADCO

Make contact delayed Self operating thermal Break contact of a Change-over contact,
when opening break contact thermal relay break before make of a
polarized relay
226C9 ZADCO 226C10 ZADCO

Empty Empty
Single-pole, 4 position
Single-pole, 6 position
switch with position
switch with a wiper that
diagram
bridger only while passing
from one position to the
next

25 of 56
APPENDIX - 8

13. Circuit Breakers, Contactors, Plugs, Sockets And Push


Buttons
E1301 IEC E1302 IEC E1303 IEC E1304 IEC

Switch Change over switch, Two way switch with


break before make Circuit breaker
center-off position
E1305 IEC E1306 IEC E1307 IEC E1308 ZADCO

Switch disconnector (on- Switch disconnector Two way disconnector


Disconnector (isolator) (isolator) with
load isolating switch) (on-load isolating
switch) with automatic interruption of circuit
release
E1309 ZADCO E1310 IEC E1311 IEC E1311A IEC

Two way disconnector Two way disconnector Contactor Contactor normally


(isolator) without (isolator) with center off closed
interruption of circuit position
E1312 IEC E1313 IEC E1314 IEC E1315 IEC

3-position switch,
Contactor with normally closed (only Mercury switch Multi-pole plug and
automatic release opening when operated socket isolator, N-pole
to the left)

26 of 56
E1316 IEC E1317 IEC E1318 IEC E1319 ZADCO

Connector assembly Connector assembly Mated connectors, plug


fixed portion movable portion side fixed and socket MCB (Miniature circuit
side movable breaker with thermal &
magnetic protection)
E1320 ZADCO E1320A ZADCO E1320B ZADCO E1321 ZADCO

Triple pole circuit


RCCB (Restricted current breaker e.g. air C.B
MCCB (Mounded case circuit breaker with fitted with 3 thermal
circuit breaker with ELCB (Earth leakage
thermal & magnetic over circuit breaker with earth over current relays and 3
thermal & magnetic current protection and thermo magnetic relays
over current protection) leakage protection)
earth leakage protection)
E1322 ZADCO E1323 ZADCO E1324 IEC E1325 IEC

Earth Switch Rack draw-out type Remote control unit, Manually operated
circuit breaker (typical rotary stack type with three-pole switch
for other draw-out spring return to neutral 1. Simplified single-
components) position and padlock line representation
facility
E1326 IEC E1327 IEC E1328 IEC E1329 IEC

Manually operated Push - Button


three-pole switch Push - button with Push - button with
2. Multi-line indicator lamp restricted access (glass
reorientation cover, etc)

27 of 56
E1330 IEC E1331 IEC E1332 IEC E1333 ZADCO

Selector switch - 3
Stop push button Emergency stop push position
Start push button
(non-locking) button
(non-locking)
E1334 ZADCO E1335 IEC E1336 IEC E1337 IEC

Selector switch - 2 Plug & socket (male


position & female) Limit switch - make Limit switch - break
contact contact

28 of 56
APPENDIX - 8

14. Automatic Tripping Devices, Starting Equipment And


Remote-Control Units

E1401 IEC E1402 IEC

Empty Empty

Measuring relay or Measuring relay controlled


related device, general by two or more mutually
dependent magnitudes
E1405-1 IEC E1405-2 IEC E1405-3 IEC E1405-4 IEC

Undervoltage Differential current Reverse current


Over current
E1405-5 IEC E1405-6 IEC E1405-7 IEC E1405-8 IEC

Time Frequency Earth-fault current Reverse power

E1405-9 IEC E1405-10 IEC E1405-11 IEC E1405-12 IEC

Overspeed
Phase-failure detection Interturn short circuits
Out of synchronism
(out of step)

29 of 56
E1405-13 IEC E1405-14 IEC E1405-15 IEC E1405-16 IEC

Thermal overload Electromagnetic


Time delay Inverse time lag (bimetal)
characteristic

30 of 56
E1405-17 IEC E1405-18 IEC E1405-19 IEC E1405-20 IEC

Flow
Pressure Fluid level
Temperature
E1405-21 IEC E1405-22 IEC E1405-23 IEC E1408 IEC

Direction of energy flow Direction of energy flow Bi-directional energy


flow Blow out device coil
towards from bus bars away from bus bars type

E1409 IEC E1410 IEC E1411 IEC E1412 IEC

Starter, general (for use on Automatic starter Automatic starter


Blow out device single-line diagrams)
permanent magnet type
E1413 IEC E1414 ZADCO E1415 IEC E1416 IEC

Starter with automatic Direct on-line contactor Series parallel starter


Direct on line contactor
release starter with protective starter for reversing
device motors
E1417 IEC E1418 IEC E1419 IEC E1420 ZADCO

Auto transformer starter Star delta starter Remote control unit


Pole changing starter
with ammeter
(e.g 8/4 poles)
controlled by rotary
stack switch for use on
single line diagram

31 of 56
E1421 ZADCO E1422 ZADCO E1423 ZADCO E1424 ZADCO

Remote control unit as Remote control unit Remote control unit


Remote control unit
E1420 & E1421, but for without ammeter without ammeter
with ammeter controlled
use on layouts only controlled by rotary controlled by push
by push buttons for use
stack switch for use on buttons for use on
on single line diagrams
single line diagrams single line diagrams
E1425 ZADCO E1426 ZADCO E1427 ZADCO E1428 ZADCO

Remote control unit as Safety switch for use on Safety switch for use
E1423& E1424, but for on layouts only Emergency switch for
single line diagram
use on layouts only use on single line
diagrams
E1429 ZADCO E1430 ZADCO E1431 ZADCO E1432 ZADCO

Remote control unit Remote control unit


Emergency switch for Remote ammeter for use
with push buttons for with start/stop push
use on layouts only on layouts only
use in P & IDS buttons and
local/remote selector
switch

32 of 56
APPENDIX - 8

15. Switch-gear And Distribution Boxes

E1501 IEC E1502 ZADCO E1503 IEC E1504 IEC

Switch gear, general Over-ground, weather-


Control desk Distribution center or proof enclosure, general
bus bars with incoming symbol pillar box
and outgoing, circuits

33 of 56
APPENDIX - 8

16. Protective Devices

E1601 IEC E1602 IEC E1603 IEC E1604 IEC

Fuse with supply side Fuse with supply side Fuse switch Fuse disconnector (fuse
indicated by thick line indicated by thick line isolator)
E1605 IEC E1606 IEC E1607 IEC E1608 IEC

Fuse with mechanical Fuse with separate alarm Fuse with alarm contact
Fuse switch
linkage (striker fuse) contact (3-terminals)
disconnector (on load
isolating fuse switch)
E1609 IEC E1610 IEC E1611 IEC E1612 IEC

Spark gap Over-voltage arrester Protective gas discharge


Lightning arrester
tube
E1613 IEC E1614 IEC

Link (closed) Link (open)

34 of 56
APPENDIX - 8

17. Instruments And Metering Systems

E1701 IEC E1702 IEC E1703 IEC

Indicating instrument, Recording instrument,


Integrating instrument,
general general
general
E1705 IEC E1706 IEC E1707 IEC E1708 IEC

Telemetering transmitter Telemetering receiver


Measuring instrument Telemetering receiver
e.g. voltmeter for controlling a measuring
controlling telemetering instrument (e.g.
transmitter voltmeter)
E1709 IEC E1710 IEC E1711 IEC E1712 IEC

Permanent-magnet Permanent magnet Moving permanent


moving coil ratio-meter Moving permanent
moving coil instrument magnet ratio-meter
(quotient meter) magnet instrument
(quotient meter)
E1713 IEC E1714 IEC E1715 IEC E1716 IEC

Electro-dynamic, Electro-dynamic, iron- Electro-dynamic, iron-


Electro-dynamic, cored instrument
ironless ratio-meter cored instrument
ironless instrument
(quotient meter)
E1717 IEC E1718 IEC E1719 IEC E1720 IEC

Vibrating reed
Moving -iron system Moving-iron ratio-meter instrument Electrostatic instrument
(quotient meter)

35 of 56
E1721 IEC E1722 IEC E1723 IEC E1724 IEC

Non-insulated Insulated thermocouple,


Thermal (hot wire) Bimetallic instrument
thermocouple, thermal thermal converter
instrument
converter
E1725 IEC E1726 IEC E1727 IEC E1728 IEC

Accuracy class index, Test voltage above 500 v Instrument used with Instrument used with the
e.g. 1.5 with errors e.g. 2kv (indication 0 the supporting surface supporting surface
expressed as a for apparatus not subject vertical horizontal
percentage of the true to dielectric tests)
valve
E1730 IEC E1731 IEC E1732 IEC

Empty

Zero adjuster Electronic device in


measuring circuit Electronic device in
auxiliary circuit
E1733 IEC E1734 IEC E1735 IEC E1736 IEC

Thermocouple, directly Thermocouple Instrument shunt


Thermocouple, general heated, non-insulated indirectly heated
(the negative pole is heating element insulated heating
represented by the element
thicker line)
E1737 IEC E1738 IEC

Empty

Amplifier Single phase bridge


connected rectifier

36 of 56
*
Note:

Terminologies for use in meters applicable to E1701, E1702, E1703

1. Ampere
2. Volt
3. Differential volt
4. Double volt
5. Watt
6. Watt-hour
7. Hertz
8. Synchroscope
9. Power-factor
10. Reactive volt-ampere hour
11. Volt-ampere hour
12. OHM
13. Hour
14. Direction indicator
15. Minute
16. Second
17. Time
18. Multiples and sub-multiples
Tera =1012
Giga = 109
Mega = 106
Kilo = 103
Mili = 103
Micro= 106
Nano= 109
Pico= 1012
19. Ammeter selector switch ZADCO
20. Voltmeter selector switch ZADCO
21. Selector switch ZADCO
22. Auto voltage regulator ZADCO

37 of 56
APPENDIX - 8

18. Lamp Fittings, Etc

E1801 IEC E1802 ZADCO E1803 ZADCO E1804 IEC

Emergency lamp fitting, Emergency lamp fitting, Emergency lighting


Lighting outlet position,
maintained non maintained luminaire on special
shown with wiring
circuit
E1805 ZADCO E1806 IEC E1807 IEC E1808 IEC

Signal Lamp /
Neon (signal) lamp Illuminating Lamp *
Discharge lamp (e.g. Hg
Discharge lamp, general =mercury, no. = sodium)

*
Notes:

If it is desired to indicate the color (c) a notation in accordance with IEC publication 62 is placed adjacent
to the symbol e.g.

RD - redBU-blue YE-yellow
WH-white GN-green AM-amber

If it is desired to indicate the type of lamp, a notation according to the following codes is placed adjacent to
the symbol:

Ne-neon
Xe-xenon
Nq-sodium vapour
Hg-mercury
I-iodine
IN-incandescent
EL-electroluminescent
ARC-fluorescent
FL-fluorescent
IR-infra-red
UV-ultra-violet
LED-light-emitting diode

38 of 56
E1810 ZADCO E1811 ZADCO E1812 IEC

Empty

Wall mounted Fluorescent lamp,


Suspended incandescent incandescent light fitting general symbol
light fitting
E1813 IEC E1813A ZADCO E1814 IEC E1815 IEC

Luminaries with two Luminaries with five Fluorescent lamp on Spot light
fluorescent tubes fluorescent tubes special circuit, e.g.
emergency circuit
E1816 IEC E1817 ZADCO E1818 IEC E1819 IEC

Navigation lamp Electrical appliance


Flood light
Flood light mounted on
lighting mast
E1820 IEC E1821 IEC E1822 IEC E1823 IEC

Heating element (e.g Signal lamp, flashing type Auxiliary apparatus for Light dependent resistor
from heater)
discharge lamp photo-conductive
(e.g. ballast) device with
symmetrical
conductivity
E1824 IEC E1825 IEC E1826 IEC E1827 ZADCO

Photodiode Optical coupling device Emergency lighting with Fluorescent lamp with
photo-conductive device opto isolator shown with battery back-up battery back-up
with asymmetrical light emitting diode and
conductivity photo-transistor

39 of 56
E1828 ZADCO E1829 ZADCO E1830 ZADCO

Bulkhead light fitting Lighting pole Lighting pole

40 of 56
APPENDIX - 8

19.Generating Stations And Substations

E1901 IEC E1902 IEC E1903 IEC E1904 IEC

Generating station, oil or Generating station, Generating station


Generating station
gas thermo-electric hydro-electric
(power plant), general
E1905 IEC E1906 IEC E1907 IEC

Empty

Generating station oil or Substation, general (e.g. Plant station


gas with gas turbine intake station

GENERATING STATIONS AND SUBSTATIONS (IN SERVICE)

E1911 IEC E1912 IEC E1913 IEC E1914 IEC

Generating station Generating station, oil or Generating station, Generating station


(power plant), general gas thermo-electric hydro-electric
E1915 IEC E1916 IEC E1917 IEC E1918 IEC

Generating station oil or Substation, general (e.g. Plant station Rectifier substation
gas with gas turbine intake station)

41 of 56
APPENDIX - 8

20. Signaling Equipment And Clocks

E2001 IEC E2002 IEC E2003 IEC E2004 IEC

Bell, electric, general


Buzzer, electric, general Horn, electric, general Siren, electric, general
E2005 IEC E2006 IEC E2007 IEC E2008 IEC

Electromechanical Electro mechanical Clock, general Master clock


position indicator with indicator with alarm con
one de-energized and tact
two operating positions
E2009 IEC E2010 IEC E2011 IEC E2012 ZADCO

Time - switch Synchronous clock (e.g. 50 Clock with an electric Drop enunciator make
HZ) motor rewind contact actuated by the
actuating system, make
contact actuated by the
target
E2013 IEC E2014 IEC

Mechanical indicator Common alarm indication

42 of 56
APPENDIX - 8

21. Protection Relay Symbols

21.1 Device Function Numbers, Indicating The Device Function Which


Causes Relay Operate
E2101 IEEE E2101 IEEE E2101 IEEE

2. Time-delay starting or
1. Master element closing relay 3. Checking or
interlocking relay
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

4. Master contactor 5. Stopping device 6. Starting circuit 7. Rate-of-change relay


breaker
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

8. Control power 9. Reversing device 10. Unit sequence 11. Multifunction device
disconnecting device switch
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

12. Over-speed device 13. Synchronous-speed 14. Under-speed device 15. Speed or frequency
device matching device
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

16. Reserved for future 18. Accelerating or 19. Starting-to-running


17. Shunting or
application decelerating device transition contactor
discharge switch

43 of 56
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

20. Electrically operated 21. Distance relay 22. Equalizer circuit 23. Temperature control
valve breaker device
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

24. Volts per hertz relay 25. Synchronizing or 26. Apparatus thermal 27. Under-voltage relay
synchronism-check device
device
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

28. Flame detector 29. Isolating contactor 30. Annunciator relay 31. Separate excitation
device

44 of 56
APPENDIX - 8

21.2 Device Function Numbers, Indicating The Device Function Which


Causes Relay Operate
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

32. Directional power 33. Position switch 34. Master sequence 35. Brush-operating or
relay device slip-ring short-
circuiting device
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

36. Polarity or 37. Undercurrent or under- 38. Bearing protective 39. Mechanical
polarizing voltage power relay device condition monitor
device
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

41. Field circuit breaker 42. Running circuit 43. Manual transfer or
40. Field relay breaker selector device
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

44. Unit sequence 45. Atmospheric condition 46. Reverse-phase or 47. Phase-sequence or
starting relay monitor phase-balance phase-balance
current relay voltage relay
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

48. Incomplete sequence 49. Machine or 50. Instantaneous over- 51. AC time over-
relay transformer thermal current relay current relay
relay

45 of 56
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

52. AC circuit breaker 53. Exciter or DC 54. Turning gear 55. Power factor relay
generator relay engaging device

46 of 56
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

56. Field application 57. Short-circuiting or 58. Rectification failure 59. Over-voltage relay
relay grounding device relay

47 of 56
APPENDIX - 8

21.3 Device Function Numbers, Indicating The Device Function Which


Causes Relay Operate
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

60. Voltage or current 61. Density switch or 62. Time-delay 63. Pressure switch
balance relay sensor stopping or
opening relay
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

64. Ground detector 65. Governor 66. Notching or 67. AC directional


relay jogging device over-current relay
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

69. Permissive control 70. Rheostat 71. Level switch


68. Blocking relay device
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

73. Load-resistor 74. Alarm relay 75. Position changing 76. DC over-current
contactor mechanism relay
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

77. Telemetering device 78. Phase-angle measuring 79. reclosing relay 80. Flow switch
relay

48 of 56
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

81. Frequency relay 82. DC load-measuring 83. Automatic selective 84. Operating
reclosing relay control or transfer mechanism
relay
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

86. Lockout relay 87. Differential 88. Auxiliary motor or


85. Carrier or pilot-wire motor generator
relay protective relay

49 of 56
APPENDIX - 8

21.4 Device Function Numbers, Indicating The Device Function Which


Causes Relay Operate
E2101 IEEE E2101 IEEE E2101 IEEE E2101 IEEE

90. Regulating device 91. Voltage directional 92. Voltage and power
89. Line switch
relay directional relay
E2101 IEEE E2101 IEEE E2101 IEEE
95, 96, 97, 98, 99

93. Field-changing 94. Tripping or trip-free


contactor relay
Used only for specific applications in individual
installations if none of the functions assigned to
the numbers from 1 to 94 is suitable

50 of 56
APPENDIX - 8

22. Building Electrical Installation (Light Switches)

E2201 ZADCO E2202 ZADCO E2203 ZADCO E2204 ZADCO

5A, one way, single pole 20/15A, one way, single SA, two way, single 20/15A two way,
switch to identify the pole switch to identify the pole switch to identify single pole switch to
number of gangs use: number of gangs use: 1G, the number of gangs identify the number of
1G, 2G, 3G, and 4G 2G, 3G, and 4G use: 1G, 2G, 3G and gangs use: 1G, 2G, and
4G 4G
E2205 ZADCO E2206 ZADCO E2207 ZADCO

Empty
5A, intermediate way 20/15A, intermediate way Switch, period limiting
switch to identify the switch to identify the
number of gangs use: number of gangs use: 1G,
1G, 2G, 3G, and 4G 2G, 3G, and 4G
E2209 ZADCO E2210 ZADCO E2211 ZADCO E2212 ZADCO

One way, double pole Metal clad one way, single Metal clad one way, Water tight single pole
switch pole switch double pole switch switch
E2214 ZADCO E2215 IEC E2216 ZADCO

Empty

Pendant switch Dimmer 13A switched socket


out let
E2217 ZADCO E2218 ZADCO E2219 ZADCO E2220 ZADCO

15A switched socket 110V switched socket 24V switched socket


Multiple switched socket
outlet outlet outlet
out let
(e.g. 2 plugs)

51 of 56
E2221 ZADCO E2222 ZADCO E2223 ZADCO E2224 ZADCO

Welding socket outlet Switched fused spur unit Telephone socket outlet TV socket outlet
with outlet
E2226C ZADCO E2226D ZADCO E2226E ZADCO E2226F ZADCO

Mirror light with shaver 2 Pole isolator 3 Pole isolator 3 Pole & neutral
outlet isolator
E2225 IEC E2226 ZADCO E2226A ZADCO E2226B ZADCO

Plug 20A flex outlet 45A flex outlet Shaver outlet


E2226G ZADCO E2226H ZADCO E2226J ZADCO E2227 IEC

Fused spur unit with Fused spur unit without Electric bell
Switched fused spur unit
outlet outlet
without outlet
E2228 ZADCO E2229 ZADCO E2230 ZADCO E2231 IEC

Bell push Bell indicator N=NO. of Bell transformer Buzzer


ways
E2232 ZADCO E2233 ZADCO E2234 IEC E2235 ZADCO

Fire and gas control


Smoke detector Heat detector Fire alarm break glass panel
unit
(manually operated)

52 of 56
E2236 ZADCO E2237 ZADCO E2238 ZADCO E2239 ZADCO

Self contained water Thermostat Telephone junction


Automatic fire detection
heater box
E2241 ZADCO E2242 ZADCO E2243 ZADCO

Empty

Exhaust fan wall Exhaust fan roof


Switch board / distribution mounted
board fuse board mounted
E2244 ZADCO E2245 ZADCO E2246 ZADCO E2247 ZADCO

Fan regulator Cooker control unit Main distribution board Ceiling fan

53 of 56
APPENDIX - 8

23. Electro Acoustic Elements

E2301 ZADCO E2302 ZADCO E2303 ZADCO E2304 ZADCO

Microphone Earphone Loudspeaker


Two way intercom
system
E2305 ZADCO E2306 ZADCO

Pickup Sound recorder

54 of 56
24 Cathodic Protection

E2401 ZADCO E2402 ZADCO E2403 ZADCO E2404 ZADCO

Transformer rectifier Current control box Borehole grounded Horizontal grounded

55 of 56
25. Hazardous Area Classification

EH02 API EH03 API EH04 API

Division 1 Division 2 Unclassified (SAFE)


area

56 of 56