380--600 V Diesel
Application Data
Engine Engine Electrical
Engine Specifications 60 Hz 50 Hz Engine Electrical System 60 Hz 50 Hz
Manufacturer Detroit Diesel/MTU Battery charging alternator:
Engine: model 16V2000 16V2000 Ground (negative/positive) Negative
G85 G65 Volts (DC) 24
R163-8A37 R163-8A38
Ampere rating 70
Engine: type 4-Cycle,
Turbocharged, Intercooled Starter motor rated voltage (DC) 24
Cylinder arrangement 16-V Battery, recommended cold cranking
amps (CCA):
Displacement, L (cu. in.) 31.84 (1943)
Qty., CCA rating each Two, 1150
Bore and stroke, mm (in.) 130 x 150 (5.12 x 5.91)
Battery voltage (DC) 12
Compression ratio 16.0:1
Piston speed, m/min. (ft./min.) 540 (1772) Fuel
Main bearings: quantity, type 9, Precision Half Shells Fuel System 60 Hz 50 Hz
Rated rpm 1800 1500 Fuel supply line, min. ID, mm (in.) 12 (0.5)
Max. power at rated rpm, kWm (BHP) 1115 (1495) 975 (1307) Fuel return line, min. ID, mm (in.) 6 (0.25)
Cylinder head material Cast Iron Max. fuel flow, Lph (gph) 480 (127)
Crankshaft material Forged Steel Min./max. fuel pressure at engine supply
Valve (exhaust) material Austenitic Steel connection, kPa (in. Hg) --30/50 (--8.8/14.8)
Governor: type, make/model ADEC Electronic Control Max. return line restriction, kPa (in. Hg) 50 (14.7)
Frequency regulation, no-load to-full load Isochronous Fuel filter: quantity, type 1, Secondary
Frequency regulation, steady state 0.25% Recommended fuel #2 Diesel
Frequency Fixed
Lubrication
Air cleaner type, all models Dry
Lubricating System 60 Hz 50 Hz
Exhaust Type Full Pressure
Exhaust System 60 Hz 50 Hz Oil pan capacity dipstick mark max.,
Exhaust flow at rated kW, m3/min. (cfm) 222 (7840) 198 (6992) L (qt.) 88 (93)
Exhaust temperature at rated kW, dry Oil pan capacity, initial filling, L (qt.) 102 (108)
exhaust, _C (_F) 550 (1022) 535 (995) Oil filter: quantity, type 2, Cartridge
Maximum allowable back pressure, Oil cooler Water-Cooled
kPa (in. Hg) 8.5 (2.5)
Exh. outlet size at eng. hookup, mm (in.) See ADV drawing
Operation Requirements
Air Requirements 60 Hz 50 Hz
Radiator-cooled cooling air,
m3/min. (scfm)] 1108 (39101) 922 (32584)
High ambient radiator-cooled cooling air, 1434 1195 Decision-Makerr 6000 Paralleling Controller
m3/min. (scfm)] (50638) (42198) Provides advanced control, system monitoring, and system diagnostics
Cooling air required for generator set with remote monitoring capabilities for paralleling multiple generator
when equipped with city water cooling or sets.
remote radiator, based on 14_C (25_F) D Paralleling capability with first-on logic, synchronizer, kW and kVAR
rise, m3/min. (scfm)] 391 (13800) load sharing, and protective relays
Combustion air, m3/min. (cfm) 87 (3072) 72 (2543) D Digital display and keypad provide easy local data access
Heat rejected to ambient air: D Measurements are selectable in metric or English units
Engine, kW (Btu/min.) 45 (2559) D Remote communication thru a PC via network or
modem configuration
Alternator, kW (Btu/min.) 64 (3640)
D Controller supports Modbusr protocol
] Air density = 1.20 kg/m3 (0.075 lbm/ft3) D Integrated voltage regulator with 0.25% regulation
D Built-in alternator thermal overload protection
D NFPA 110 Level 1 capability
Refer to G6-107 for additional controller features and accessories.
G5-388 (1000REOZDE) 4/13b
KOHLER CO., Kohler, Wisconsin 53044 USA Kohler Power Systems
Phone 920-457-4441, Fax 920-459-1646 Asia Pacific Headquarters
For the nearest sales and service outlet in the 7 Jurong Pier Road
US and Canada, phone 1-800-544-2444 Singapore 619159