UNISTAR RANGE OF PRODUCTS

Sr. Products Specification Application


No.

A. RODS
Aluminum redraw IS-5484 Cables and over head
rods Conductors

B. BARE AND
COVERED OVER-
HEAD
CONDUCTORS

1. Round BS-125 Railway and Electric


Copper/Cadmium- Traction Conductors.
Copper Catenary
wire.

2. Earth Conductors- BS-6360 General earth


Copper Conductors.

3. Over-head IS-398 Over-head bulk power


Conductors with BS-215 transmission lines.
Aluminium/Aluminiu
m Alloy AAC, ACSR,
AAAC & ACAR.

4. Insulated over-head BS-6485 Over-head distribution


Conductors of line conductor for
Copper and corrosive atmosphere.
Aluminium with
PVC.covering

5. Cadmium-Copper CIL/P/125B Over-head distribution


over-head line conductor for
Conductors with PVC corrosive atmosphere.
Insulation

6. Aerial Bunched REC-32/84 & Over-head power


Conductors IEC-502 transmission and
(ABC). distribution.

C. XLPE CABLES
1. 1 KV Power Cables IS-7098 1.1 KV Power
(1.1 KV). distribution and
Part-I control Circuits.

IEC-502

2. HV Power Cables IS-7098 Medium and High


(a) from 3.3 KV to 33 Voltage
KV. Part-II
Power transmission &
IEC-502
distribution.

(b) EHV Power Cables IS-7098 Medium and High


above 33 KV & up to Voltage Power
220 KV. Part-III transmission &
distribution.
IEC-502

IEC-840

SS4241417

AEIC CS7

IEC-62067

3. Submarine Cables. IS-7098 Under water Power


(Part I & II) Transmission.

4. Radiation resistant IS-7098 Power and control cables


power Part I & II used inside reactor
cables up to 11 KV. building.

D. PVC CABLES

1. Power and Control IS-1554 General power


Cables Part I & II distribution &
up to 11 KV. Control purposes.

2. Mining Cables. NCB-UK Power distribution


Cables
IS-1554 inside coal mines.

Part I & II
3. Wiring and Service IS-694 General purpose flexible
Cables and fixed type wiring
BS-6004 cables with PVC and
including flexible Rubber insulation.
cords BS-6500

weather proof
service cables.

4. Air field lighting Defense Run-way illumination.


cables. specifications
.

5. Railway Signaling IRS-S-35 Railway Signaling


Cables. IRS-S-63 circuits for
use in Electric traction
area

6. Flexible wiring ICF/Elect/80 Power and Control


cables for 7 Cables for
Coaches. RDSO E- coaches.
14/01 (III)

7. Wiring Cables for IS-2465 Automobile wiring cables


vehicles. BS-6862 with
PVC/Rubber insulation.

8. Equipment wires DEF-61-12 Communication


screened / DEF-10 equipment
wiring, especially for
unscreened and Defense
microphone

Wires.

9. Power and Control IS-1554 Part Cables for Power


Cables with better I & II generating
flame resistance
with low smoke and IS-7098 Part stations and other
toxicity (FRLS and I & II hazardous
Survival type
Cables). IS-9968 Part industrial installations.
I

IEC-502
10. Instrumentation IS-1554 Part Cables for sensitive solid
Cables. I state

IS-9968 Part devices in electronic


I control

IEC-502 system i.e. Computer,


etc.
BS-5308

11. Winding wires for IS-8783, NSW Submersible motor


submersible pump winding.
motors.

E. RUBBER CABLES

1. Natural rubber and IS-9968 General wiring, control


(a) and
synthetic rubber (Part I & II) power distribution
insulated flexible / trailing use for
IEC-502 mine etc. with special
sheathed flexible/ properties thermal
endurance, oil resistance
and Flame Retardant
non-flexible cables
combined with higher
for
mechanical strength.
power distribution

lighting and control


etc.

up to 11 KV (UE).

Welding Cables with IS-9857 For use in electric


(b) Aluminium & Copper welding.
Conductors.

2. Ship wiring cables DGS-211, Power and Control in


up to 1000 V. ships.
DGS-212,
ABS,

LRS ,DNV, BV,

[EC-92-3, IRS

NES-526

and BS-6883
3. High temperature BS-6007 Used in location of high
Silicone ambient temperature.
IS-9968
Rubber insulated
Cables for (Part I & II)

the use upto 200 OC. and BS-6195

DGS-211

NES-526

4. Mining & Quarry IS-1026 Mining cables of all


Cables upto varieties.
IS-691
6.6 KV Flat Shuttle
Car Cables, BS-6708

Miners Cap-Lamps BS-6116


Cable.
IS-2593

NCB-UK

5. Power Cables and RDSO-E- Cables for Electric


conductors 14/01 locomotives, diesel
(I) & (II) locomotives & Electric
for rolling stock. multiple units.

6. PVC and Elastomeric IS-4289 Power and Control use in


Lift OTIS and Elevators and Lifts.
Customer
Cables with and Specification
without

steel Hauser up to
1100 V. (Round as
well as flat lift
cables)
7. Aircraft ignition and BSG-177 Aircraft wiring and
(a) wiring ignition
BS-2E-21 circuits.
Cables UNINYVIN,
BSG-189
UNIPREN,
UNITERSIL and EL-1 895

UNI-PLUG SHEATH
Cables.

Radar and Data- Defense Cables for radar and


(b) Transmission Specifications Anti-Aircraft Guns.
Cables.

8. High frequency BS-2316 High frequency


Coaxial MILC-1 7E communication
Cables. circuits and Cable TV
use.

9. Fluoro-plastic Cables JSS and MIL Aircraft wiring, High


and Specifications Temp.
wires.
Equipment wires, Cables
for Oil

rigs, computers and


electronic

exchanges.

10. Electro Logging ONGC Cables for Oil


cables. exploration
equipments.

F. CAPACITORS FOR AC SYSTEM

1 Power Factor
improvement
capacitors
High voltage All- IS-2834 Power Factor
(a) Polypropylene improvement in

dielectric capacitors industries (individual)

impregnated with compensation of motor,


Non-PCB group

Oil Unit rating - 50 compensation) EHV & HV


to 400 KVAR
sub-stations, large arc
Unit voltage - 3.3 to
13.5 KV Furnaces (Capacitor for
static
Bank rating - By
assembly of VAR control, filter circuit
and
basic units as per
required KVAR group compensation)
net-work
Bank voltage - 3.3
KV to 132 KV. (Pole mounted
capacitor).

Low and medium IS-2834 Power factor


(b) voltage self healing improvement in
low loss metallized industrial low voltage
polypropylene load (with or without
capacitors. automatic control).
(MPP OIL COOLED)
Unit rating - 1 to 50
KVAR Unit voltage -
380 to 440 V AC
Bank rating - By
assembly of basic
units as per required
KVAR Bank voltage -
380 to 440 V AC.
ISI marked.
(c) Low and medium IS-2834 Power factor
voltage 3 phase 50 improvement in
Hz capacitor made industrial low voltage
from All- load (with or without
Polypropylene automatic control).
impregnated with
Non-PCB oil Unit
rating - 1 to 50
KVAR Unit voltage -
up to 600 V AC Bank
rating - By assembly
of basic units as per
required KVAR.

Power and medium IS-2834 Power factor


(d) frequency capacitors IS-9251 improvement and
Air/Water cooled for load balancing in
induction furnace induction furnace.
application
Capacitors made
from All-
Polypropylene
impregnated with
Non-PCB oil Unit
rating - 25 to 150
KVAR Voltage rating
- 380 to 1600 V AC@

2. DC Capacitors Special application like


impulse generators filter
circuits.

3. Surge Capacitors
Surge capacitors Surge protection of
made from All- Motors
Polypropylene Transformers, etc.
impregnated with
Non-PCB Oil for 3.3,
6.6 and 11 KV
system.

You might also like