You are on page 1of 3

5.

DESIGN OF PILE
400mm DIA PILE DESIGN(APPLICABLE FOR 0m- 0.5m FILL)
INPUT DATA :
Dia of Pile = 400 mm
Grade of Concrete = 30 N/mm2
Grade of Steel = 500 N/mm2
Maxm.Vertical Load On Pile = 79.3/10= 8T 79.30 KN
Maxm. Tension On Pile = 0/10= 0.00 KN
Maxm. Lateral Load On Pile = 21.668/10= 2.2 T 21.67 KN
Pile Cut-off Level = 0.075
Bottom Of Pile = 4.575
Length of Pile = 4.500 m

Embeded length of pile (Le) = 4.5 m


L1 = 0 (Since pile is totally embeded )

Depth of fixity, LF = 2.79 m As per Geotechnical Recommendation

Axial Load On Pile = 8.00 T

Lateral load at the pile head, H = 2.20 T

From C - 4.2
Deflection at the pile head,
3 3
Y = H(e+ZF) /3EI x 10 For free head pile
= 1.0494 mm

Fixed end moment ,MF = H.(e+ZF) For free head pile


= 60.454 kNm

From Fig. 5A for free head


pile reduction factor, m = 0.4
for piles in sand and normally loaded clays
consolidated case and L1/T = 0
Now , actual moment ,M = m*MF
= 0.4*60.454
= 24.181 kN-m
REINFORCEMENT OF PILE

1. Design for axial compression

Axial load ,P = 80 kN
Diameter of pile = 400.000 mm
Gross area , Ag = 125663.71 mm2
Load factor = 1.5
Pu = 120.00 kN
Pu/Ag = 0.955 N/mm2
fck = 30
fy = 500
p = 0.00 From SP 16, Chart 26

Minm % age of steel required = 0.4 From Clause 6.11.1 (Part I/ Sec 1) of IS 2911- 2010
Area of steel required, As = 502.655 mm2
Diameters of bar used, = 16 mm
Areas of respective bar dia. = 201.06 mm2
Nos. of respective bar dia. provided
= 8
Total no. of bars provided = 8
Area of steel provided, As = 1608.50 mm2
% age of steel provided = 1.28 O.K

2. Design for combined axial compression and bending

Axial load ,P = 80 kN
Moment, M = 24.181 kN-m
Length of column, (L1+Lf) = 2790.00 mm
Ratio of length to dia of column = 7.00 < 12 , Hence short column
ex/D = 0.000 (From Table 1, SP16)
ex = 0.000 mm
Minimum eccentricity , emin = 18.91 mm eccentricity of 200thk. block wall placed on pile cap
Additional Moments, M = 16.0000 kN-m = 200
Total Moment Mtotal = 40.181488 kN-m
=
Diameter of pile = 400 mm
Clear cover = 50 mm
d'/D = 0.125 (Taking as 0.15)
fck = 30
fy = 500
Load factor = 1.5
Pu/fckd2 = 0.025
Mu/fckd3 = 0.031
p/fck = 0.037 From SP-16 ,Chart61
p = 1.11

Minm % age of steel required = 0.4 From Clause 6.11.1 (Part I/ Sec 1) of IS 2911- 2010
Area of steel required, As = 1394.867 mm2
Diameters of bar used, = 16 mm
Areas of respective bar dia. = 201.06 mm2
Nos. of respective bar dia. provided
= 8
Total no. of bars provided = 8
Area of steel provided, As = 1608.50 mm2
% age of steel provided = 1.28 O.K

3. Design for pullout

Pull out ,P = 0 T Tension


Diameter of pile = 400 mm
fck = 30
fy = 500
Load factor = 1.5
Area of steelp/f
required,
ck Ast = 1.5*P*10000/(0.87*fy)
= 0.00
p = 0.00

Minm % age of steel required = 0.4 From Clause 6.11.1 (Part I/ Sec 1) of IS 2911- 2010
Area of steel required, As = 502.655 mm2
Diameters of bar used, = 16 mm
Areas of respective bar dia. = 201.06 mm2
Nos. of respective bar dia. provided
= 8
Total no. of bars provided = 8
Area of steel provided, As = 1608.50 mm2
% age of steel provided = 1.28 O.K
4. Checking for Shear

Shear ,V = 2.2 T shear


Diameter of pile = 400 mm
Eqivalent side of rectangle,a = 354 mm
Clear cover = 50 mm
effective depth ,d = 288.49 mm
fck = 30 N/mm2
fy = 500 N/mm2
pile dia
Load factor = 1.5
Calc shear stress , Vu/bd = 0.323 N/mm2
%age of steel prov in one side = 0.3200 %
pile cap
Permissible shear stress,tc= = 0.41 From SP-16 ,Table 61
O.K
Hence, Shear reinforcement is not required
Vus-tcbd= -8929.599278 N
From Clause 26.5.1.6 of IS 456
Diameter of bar used, = 8 mm
Area of 8mm bar = 50.27 mm2
Spacing ,Sv = 0.87*fy*Asv*d/Vus
= 573 mm

Provide shear reinforcement 8mm @ 150mm c/c

Spacing of shear reinf below depth of fixity (as per clause 26.5.3.2 )
i) The least lateral dimension of compression member = 400 mm
ii) Sixteen times the smallest diameter of the longitudinal reif bar = 256 mm
ii)300mm

Provide shear reinforcement 8mm @ 150mm c/c for full length of the pile.