EC Declaration of Conformity

The undersigned, representing the following supplier and the authorised representative established within the
Community
Rockwell Automation/Allen-Bradley Rockwell Automation, Subsidiary of
2 Executive Drive Rockwell International GmbH
Chelmsford, MA 01824 -- USA Dsselberger Strae 15
D-42781 Haan, Germany
herewith declare that the Products Relays and Control Units
Product identification (brand and Allen-Bradley/Guardmaster, Monitoring and Control Devices,
catalogue number/part number):
Bulletin 440R
(reference the attached list of catalogue numbers)

Product Safety Function: Minotaur units are used for circuit monitoring and ensure a safe state at
the machine if a fault is detected. CU units provide a controlled output
signal, conditional on time or machine movement and contactor status.

are in conformity with the provisions of the following EC Directive(s) when installed in accordance with the
installation instructions contained in the product documentation:
73/23/EEC Low Voltage Directive as amended by 93/68/EEC
98/37/EC Machine Safety Directive
89/336/EEC EMC Directive as amended by 92/31/EEC and 93/68/EEC

and complies with the provisions of the following harmonised standards:


EN 292-1: 1991 Safety of MachineryBasic concepts, general principles for designPart 1:
Basic terminology, methodology.
EN 60204-1: 1992 Safety of Machinery Electrical equipment of machines, Part 1:General
requirements
EN 50081-2: 1993 Electromagnetic compatibility - Generic emission standard -- Part 2:
Industrial environment
EN 50082-2: 1995 Electromagnetic compatibility - Generic immunity standard -- Part 2:
Industrial environment
EN 954-1: 1996 Safety of Machinery Safety related parts of control systems Part 1:
General principles for design.

Year of CE Marking 2000

Supplier: Authorised Representative in the Community:

i.V.
Signature Signature
Name: John M. Wu Name: Viktor Schiffer
Position: Director, Quality Engineering Position: Engineering Manager
Date: 13-Mar-2001 Date: 14-Mar-2001

Document Control Number: SEN-0194-A-EN 1/3


Catalogue Series 1 Description CE Mark
number
EMC LVD MSD
440R-A32003 Minotaur Power Supply Unit Yes Yes Yes
440R-B23020 Minotaur Single Channel monitoring safety relay Yes Yes Yes
440R-C23017 Minotaur Dual channel universal monitoring safety relays Yes Yes Yes
440R-C23018 Minotaur Dual channel universal monitoring safety relays Yes Yes Yes
440R-C23019 Minotaur Dual channel universal monitoring safety relays Yes Yes Yes
440R-D23021 Minotaur 2 hand control monitoring units for mechanical or Yes Yes Yes
electronic switches
440R-D23022 Minotaur 2 hand control monitoring units for mechanical or Yes Yes Yes
electronic switches
440R-D23023 Minotaur 2 hand control monitoring units for mechanical or Yes Yes Yes
electronic switches
440R-D23024 Minotaur 2 hand control monitoring units for mechanical or Yes Yes Yes
electronic switches
440R-D23025 Minotaur 2 hand control monitoring units for mechanical or Yes Yes Yes
electronic switches
440R-D23026 Minotaur 2 hand control monitoring units for mechanical or Yes Yes Yes
electronic switches
440R-E23030 Minotaur Single channel, monitoring safety relay and Yes Yes Yes
extension unit
440R-E23031 Minotaur Single channel, monitoring safety relay and Yes Yes Yes
extension unit
440R-F23027 Minotaur Dual channel universal monitoring safety relays Yes Yes Yes
440R-F23028 Minotaur Dual channel universal monitoring safety relays Yes Yes Yes
440R-G23029 Minotaur Universal monitoring safety relay with immediate Yes Yes Yes
and delayed outputs
440R-J23044 Minotaur Dual channel monitoring safety relay with Yes Yes Yes
monitored manual reset
440R-J23045 Minotaur Dual channel monitoring safety relay with Yes Yes Yes
monitored manual reset
440R-J23046 Minotaur Dual channel monitoring safety relay with Yes Yes Yes
monitored manual reset
440R-K23041 Minotaur Dual channel monitoring safety relay with auto Yes Yes Yes
reset
440R-K23042 Minotaur Dual channel monitoring safety relay with auto Yes Yes Yes
reset
440R-K23043 Minotaur Dual channel monitoring safety relay with auto Yes Yes Yes
reset
440R-L23047 Minotaur Dual channel monitoring safety relay with auto Yes Yes Yes
reset
440R-M23048 Minotaur Monitoring safety relay with immediate and Yes Yes Yes
delayed outputs
440R-N23059 Minotaur Dual channel monitoring safety relay with auto or Yes Yes Yes
monitored manual reset
440R-S07139 CU2 Electronic stop motion detector Yes Yes Yes

Document Control Number: SEN-0194-A-EN 2/3


Catalogue Series 1 Description CE Mark
number

440R-S07140 CU2 Electronic stop motion detector Yes Yes Yes


440R-S07141 CU2 Electronic stop motion detector Yes Yes Yes
440R-S07172 CU2 Electronic stop motion detector Yes Yes Yes
440R-S07173 CU2 Electronic stop motion detector Yes Yes Yes
440R-T07114 CU1 Electronic Timer Yes Yes Yes

1) If no series number or letter is given, then all series are covered.

Document Control Number: SEN-0194-A-EN 3/3