RTU560 product line

Modem 23WT23
Data sheet

Characteristics
The board 23WT23 is a printed circuit in Euro-card format (160
mm x 100 mm). All necessary configuration like transmit output
level, receiver sensitivity, two- or four wire operation are config-
urable by jumper.

The interface to the data terminal equipment (DTE) operates


according to the RS 232-C standard and supplies the following
signals:
TxD Transmit data
RxD Receive data
RTS Request to send
DCD Data carrier detected
CTS Clear to send
DSR Data set ready

The receiver level is monitored and an alarm relay indicates in


parallel to the light emitting diode (LED) ST a drop out for a
Application
longer period of the carrier (approx. 4-6 seconds).
The 23WT23 board is a modem which converts the serial data
LEDs on the front plate show the signal state of the RS 232-C
according to CCITT V.23 standard. Therefore it can be used for
interface. By the disconnect test sockets on the front plate the
the transmission via leased PTT-lines, private networks or for ra-
serial interface signals as also the VFT-lines can be measured or
dio transmission.
opened.
Two- or four-wire operation mode is selectable by jumper. The
Additional VF signal transformer have to be used for requested
voice frequency (VF) output has a high impedance which enables
higher isolation voltages. Surge voltage protection elements can
the connection of up to 10 remote stations to a multi drop line.
be optional inserted on request to protect against transient over-
voltage peaks (see Fig. 2).
The modem 23WT23 is available in two versions (rubrics):
R0001: 5 V DC power supply
The 23WT23 modem operates according to CCITT V.23 in half-
R0002: 24 V DC power supply
and full-duplex mode with 1200 bit/s. Version R002 is connec-
tor compatible to the 23WT21 modem and should be used in
RTU232 basic subrack only. In all other cases the 5 volt version
rubric 0001 should be used.

Figure 1: Block diagram 23 WT23


NF2a
A1 A1

Z0
EMI
Filter NF2b
E1 E1

NF1a S P
Z0 A2 A2
EMI
Filter
NF1b
E2 E2

Two-wire connection
NF2a A1 A1

Z0
EMI
Filter NF2b
E1 E1

S P
NF1a
A2 A2
Receive
Z0
EMI
Filter
NF1b
E2 E2
Four-wire connection
A1 A1

E1 E1

VF signal - transformer S P
A2 A2 Transmit

E2 E2

Figure 2: Communication line connection by VF signal transformer

2 | 1KGT 150 538 V003 1 - Modem 23WT23


Technical data Connection type

RTU560 backplane connector 48 pole type F DIN 41612


In addition to the RTU500 series general technical data, the fol-
lowing applies:
Test voltage

General Data DC test voltage 500 V DC


CECC 42000
Type of modulation Frequency shift keying (FSK) accord-
ing to CCITT V.23, with 1200 bps
Electromagnetic Compatibility
Type of communication point-to-point connection or multipoint
network Electrical fast transient test 1 kV
IEC 801-4, class 2

Serial Interface
Environmental conditions
Standard RS 232-C
Nominal operating temperature range: 0C... 70C
Signal lines D1 TxD/103
EN 60068-2-1, -2-2, -2-14
D2 RxD/104
S2 RTS/105 Relative humidity 5 ... 95 %
M2 CTS/106 EN 60068-2-30 (non condensing)
M1 DSR/107
M5 DCD/109 Ordering information

23WT23 R0001 1KGT008200R0001


Transmitter 5 V DC power supply
Transmit output level at ZA -6 / -10 / -13 / -26 dBm configuration 23WT23 R0002 1KGT008200R0002
by jumper
24 V DC power supply
Output impedance 600 non earthed and symmetrical
or
> 6 k configuration by jumper

Receiver

Receive level range 0...-47 dBm

Sensitivity -17 / -27 / -37 / -47 dBm by jumper

Input impedance 600 non earthed and symmetrical


or
> 6 k configuration by jumper

Level monitoring and alarm relay

Alarm delay time approx. 5 s

Alarm relay (contact) 60 V DC / 0,5 A / 30 W

Current consumption for power supplied via RTU560 backplane

5 V DC 350 mA

24 V DC 70 mA

Mechanical layout

Dimensions 160 mm x 100 mm, 3HE euro card


format
4R (20 mm) front panel

Housing type Printed circuit board

Mounting for mounting in RTU560 racks

Weight 250 g

Modem 23WT23 - 1KGT 150 538 V003 1 | 3


Data table

Data format Serial, binary, asynchronous

Traffic mode Point-to-point or multi-drop


Dim
Frequency shift keying (FSK) with carrier
Modulation type
switch off for multi-drop networks

Mid frequency 1700 Hz

MARK 1300 Hz
Frequency
SPACE 2100 Hz

Nominal transmission level -6/-10/-13/-26 dBm1

Channel delay time


Typical 1,6 ms
RTS=ON to CTS=ON

Channel delay time2 Minimum 10,1 ms

RTS=ON to DCD=ON Maximum 11,0 ms

Channel delay time2


Minimum 0,7 ms
RTS=OFF to DCD=OFF

Upper identifier frequency FA = FC + F = SPACE = TxD (D1)

Lower identifier frequency FZ = FC - F = MARK = TxD (D1)

1 As voltage level related to 775 mV


2 Without influence of the transmission channel

4 | 1KGT 150 538 V003 1 - Modem 23WT23


ABB AG Note:
Power Systems Division The specifications, data, design or other information contained in this document
P.O. Box 10 03 51 (the Brochure) - together: the Information - shall only be for information pur-

68128 Mannheim, Germany poses and shall in no respect be binding. The Brochure does not claim to be ex-
haustive. Technical data in the Information are only approximate figures. We re-

www.abb.com/substationautomation serve the right at any time to make technical changes or modify the contents of
this document without prior notice. The user shall be solely responsible for the
use of any application example or information described within this document.
The described examples and solutions are examples only and do not represent
any comprehensive or complete solution. The user shall determine at its sole
discretion, or as the case may be, customize, program or add value to the ABB
products including software by creating solutions for the end customer and to
assess whether and to what extent the products are suitable and need to be ad-
justed or customized.

This product is designed to be connected to and to communicate information


and data via a network interface. It is the users sole responsibility to provide and
continuously ensure a secure connection between the product and users or end
customers network or any other network (as the case may be). The user shall es-
tablish and maintain any appropriate measures (such as but not limited to the in-
stallation of firewalls, application of authentication measures, encryption of da-
ta, installation of anti-virus programs, etc) to protect the product, the network,
its system and the interface against any kind of security breaches, unauthorized
access, interference, intrusion, leakage and/or theft of data or information. ABB
AG is not liable for any damages and/or losses related to such security breaches,
any unauthorized access, interference, intrusion, leakage and/or theft of data or
information.

ABB AG shall be under no warranty whatsoever whether express or implied and


assumes no responsibility for the information contained in this document or for
any errors that may appear in this document. ABB AG's liability under or in con-
nection with this Brochure or the files included within the Brochure, irrespective
of the legal ground towards any person or entity, to which the Brochure has been
made available, in view of any damages including costs or losses shall be exclud-
ed. In particular ABB AG shall in no event be liable for any indirect, consequen-
tial or special damages, such as but not limited to loss of profit, loss of pro-
duction, loss of revenue, loss of data, loss of use, loss of earnings, cost of cap-
ital or cost connected with an interruption of business or operation, third party
claims. The exclusion of liability shall not apply in the case of intention or gross
negligence. The present declaration shall be governed by and construed in ac-
cordance with the laws of Switzerland under exclusion of its conflict of laws rules
and of the Vienna Convention on the International Sale of Goods (CISG).

ABB AG reserves all rights in particular copyrights and other intellectual property
rights. Any reproduction, disclosure to third parties or utilization of its contents -
in whole or in part - is not permitted without the prior written consent of ABB AG.

Copyright ABB 2014


All rights reserved

Modem 23WT23 - 1KGT 150 538 V003 1 | 5