Share technical questions here i will Update and will complete all questions in NPGCL Test
1.Vertex is also called=Node
2.Bulb power is 2% then current will be =4% 3.What is transformer part Primary coil secondary coil & = Core 4. Electric lines of force about negative point charge are =radial inwards 5.Which is Semiconducter Switch = Thyristor 6. How thyrister is turned off= Forced Commutation 7. Protection relay used are =Instantanous and Time Over current 8.Current transformer is used with Protection device for measuring 9.Which is not Part of Steam Turbine??Moderator 10.Diode Operation voltage 0-0.7v? 11.Power Plants run on Natural Gas ,Steam coal , etc are =Fossil Fuel Plants 12.Which Plant donot used Heat Exchangers or turbines= Geothermal 13.steam power plant flow chart or something how many steps=4 14. in a generator of 60 HZ and 10 Pole what will be N Speed = 120*60/10=720 15. In a Substation where no transformer is Switchig Substation 16.high frequency application we use --Air core Transformer 17.Sin wave is characterized by amplitude, frequency and (phase) 18.Dynamic Disturbance Recorders (DDRs), which record incidents that portray power system behavior during dyna 19.Induction motor rotor are Squirrel cage and Wound type 20. A sinosoid is representd by Phasor 21.If there are less then 4 free electron then its =Conductor 22.Which is Not a substation = Line Substation 23.Which is not at type of thyristor?= inverter Grade 24. Efficency of thermal plant =33-48% 25.What is basic pronciple behind motor operation?=electromagnetism 26. induction motor is similar to=asynchronous 27.Synchronous generators are used, because they offer precise control of voltage, frequency, VARS , watts. 28.Voltage Regulation in generation voltage = i think +-3 4 was not in opt 29. SEIMENS is unit of Conductance 30.System protection devices which includes .Reliablity selectivity, cost , speed , simplicity 31.2 types of Exciters 1. Rotating and 2. static 32. Which transfomrmer is used in arc Welding???? Leakage 33.When admittance increases current increases or Decrease? Increase 34.Power switch is characterized into how many groups 35. stator core is made of many thin metal sheets called lamination 36.most squirrel cage rotor are made bye die casting of Alumunium conductor bars 37.all process system consist of three main factor or trem, varriabel control variable uncontrolled 38.The sensitivity of measurement is a measure of the change in the instrument output, which occurs when the quanti 39.Substation transform voltage from high to low . and reverse and perform many of the several important function 40. The input for a distribution substation is typically at least two transmission or subtransmission lines 41. Generators are cooled by Air-water cooled and Fins 42.A process control system consists of process, measurement control:= Analysis 43.Generator voltage is determined from excitation is island operation 44.The matrix obtained by deleting the column corresponding to the reference node in the element node incidence ma 45 Stainer is used to prevent foreign particles to reach turbine alongwith steam. 46. is used for emergency stop of steam along (throttle valve ) 47.Complex quantities in power system are represented by (phasor) 48.When a small resistance or impedance is accidentally or intentionally inserted b/w two points of different potential 49.The loss in a T/F due to reversal of direction of current is called: Hysterisis loss. 50.The frequency of generator depends on speed and (no of poles) 51.Higher efficiency can be obtained at higher temperature, this is dictated by (carnot efficiency) 52.The boiler in which tubes are placed in a horizontal cylinder is called (horizontal , fin tube)????? system behavior during dynamic events such as low-frequency
uency, VARS , watts.
which occurs when the quantity being measured changes by a given amount. e several important function ansmission lines he element node incidence matrix A is called bus incidence matrix A
wo points of different potential, it is called short circuit)
First Generation of Mobile Phones Was Analog Voice, and The Second Gen-Eration Was Digital Voice. The Third Generation of Mobile Phones, or 3G As It Is Called, Is All About Digital Voice and Data