Over 60 years of Alarko experience in Circulation Pumps...

ALARKO OPTIMA
Protect the nature...
Alarko intends to improve the quality of life significantly by extending its range of products with
innovative products with respect for the environment and higher performance as well as significant
energy-saving features. The process of adaptation to the European Union ECO Design directives
resulted in a real milestone for Alarko circulation pumps: namely Alarko Optima.

Major Benefits
of Alarko Optima

1. Class-A Energy Saving


2. Ideal Performance
3. Reliability
4. Ease of Installation and
Commissioning
5. After sales services and ease of
supplying spare parts
6. Electronic-controlled
7. Meets SGM-2011/15 standard of
Turkey and EC 641/2009 standard
of the EC

All Alarko circulation pumps already meet the requirements of 2020.

European Commission Eco Design


Requirements for Circulation Pumps
Replacement of the
wet-rotor type
circulation pumps
integrated into the
product prior to August
No requirements EEI 0,23
1, 2015
IDEAL
PERFORMANCE Wet-rotor type
circulation pumps
integrated into the
product New Production
No requirements EEI 0,23

Unlike the traditional single and


three-speed pumps, Alarko Optima
serves at the ideal operation levels Independent
wet-rotor type
continuously with three different circulation pumps for No
Heating/Cooling requiremen
EEI 0,27 EEI 0,23
modes of operation. And this results Systems
in high energy saving.
01/01/2014 01/08/2015 01/01/2020

2
EASE OF
INSTALLATI USER
SAFETY ON AND FRIENDLY
COMMISSIONING LCD SCREEN

The compliance of Alarko Optima Alarko Optima circulation pumps All controls and settings are
circulation pumps with the following are equipped with the connection performed with 5 buttons only.
standards and directives has been box and connection sockets which Two-line OLED screen.
proven by the relevant tests. help commissioning them rapidly
and easily. These special connection User friendly control system with
Machinery Directive 2006/42/EC Turkish software.
sockets located on the control box
Low Voltage Directive 2006/95/EC) allow the pump to be connected English language support
safely and rapidly without contacting provided as standard in the menu.
EMC Directive 2004/108/EC
the mains voltage and electronic
Service info feature which
Ecodesign Directive 2009/125/ EC systems.
displays the latest 5 error codes
TS EN 60335-2-51:2003 + A 2:2012 and descriptions.
TS EN 16297-1:2012
TS EN 16297-2:2012
TS EN 60335-1:2012

ECM Technology offers significant advantages when compared with other motor drive technologies.

ECM No external sensors and controllers are


necessary.
The motor service life is extended thanks to the
low level of tension at the motor bearings.
The motor runs at lower temperatures The levels of vibration and noise are lower.
and generates less heat.

General Selection Chart


13

12

11
4/12
10

8
8/12
7
5/8
H(m)

6
5/12 6/12
5
5/9
4

3
4/4
2

0
0 5 10 15 20 25 30 35 40 45 50 55 60
Q (m3/h)

3
excellence is in the
details of design...
Optima circulation pumps produced with the latest technologies, with every single
component designed carefully, succeeded in all the tests performed.
Designed and produced completely by Turkish engineers, Optima is one step ahead
of the time...

1
3
Door with special design
which allows easy

5
connection of cables.
High-efficiency controller
unique to Optima
and the control box Energy efficiency
extending the service improved by the stator
life of the controller by liner made of special

2 minimizing heat. composite material.

User Friendly and Energy


Saving OLED screen and
keypad developed for
4 Stator with special
design to minimize
Optima specifically.
the losses during
operation.

4
6 High-efficiency rotor

9
with fixed magnet
maximizing the
efficiency of the motor.
Pump body with
special design
offering high
10
8
hydraulic efficiency
and silent operation.
Polypropylene
Specially designed insulation liner ensuring
PPO fan with high thermal insulation of
hydraulic efficiency. the pump body.
Supplied with the pump as

7
standard.

Maintenance free
and durable carbon
bearings and filter
made of special
stainless material to
prevent contaminants
in the fluid from getting
into the motor.

5
E rP
READY

OPTIMA
4/4 LOW ENERGY CONSUMPTION
SAVE the NATURE

Maximum Pumping Height [m] According to the pump type


Maximum Flow Rate [m3/h] According to the pump type
Motor Speed [rpm] 1.600 3.700
1~ 230 V AC %10, 50 Hz, PE
Input Voltage and Frequency (ground protected)
Rated Current [A] 0,7
Power drawn [W] 12 166
Energy Efficiency Index
< 0.23
(EEI)
Insulation Class F
Protection Class IP 44
Temperature Class TF 110
Maximum System Pressure PN 6/10 (1)
Sound Pressure < 56 dB (depends on the type)
Relative Humidity < %90
Weight 10 kg
1
Pump is suitable for use in both pressure values.

113
83
88

40 4x14 m

156
220 204

100

110

66 53
151
75,5 227,2
92 92

6
Variable Pressure Operating Mode
v (m/s)
0 0,2 0,4 0,6 0,8 1 1,2 Variable
1,4 Pressure Operating Mode
v (m/s) Variable Pressure 1,6 1,8
Operating Mode
6 v (m/s)
0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8
6 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8
6
5m
5
5m
5 5m
5
4m
4
4m
4 4m
4
3m
(m)H (m)

3
3m
3 3m
HH(m)

2 2m

2 2m
2 2m

1
1
1

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
0
0 0 1 2 3 4 5 Q (m 3/h) 7
6 8 9 10 11 12 13
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Q (m 33/h)
Q (m /h)

Fixed Pressure Operating Mode


v (m/s)
0 0,2 0,4 0,6 0,8 1 1,2 Fixed
1,4 Pressure Operating
1,6 Mode
1,8
6 v (m/s) Fixed Pressure Operating Mode
v (m/s)
0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8
6 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8
6
5m
5
5m
5 5m
5
4m
4
4m
4 4m
4
3m
(m)H (m)

3
3m
3 3m
HH(m)

2 2m

2 2m
2 2m

1 1m

1 1m
1 1m

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
0 Q (m 3/h)
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13
0 1 2 3 4 5 6
Q (m 3/h) 7 8 9 10 11 12 13
Q (m 3/h)

v (m/s) Manual Operation Mode


Manual Operation Mode
0 0,2 0,4 0,6 0,8 v (m/s) 1 1,2 1,4 Manual 1,6 1,8
Operation Mode
v (m/s)
6
0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8
0 3700 rpm 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8
6
6
3700 rpm
3700 rpm
5
3400 rpm
5
5 3400 rpm
3400 rpm
OPTIMA 4/4

4
4
4
2800 rpm
(m)H (m)

3
2800 rpm
2800 rpm
3
HH(m)

3
2200 rpm
2
2200 rpm
2 2200 rpm
2
1600 rpm
1 1600 rpm
1600 rpm
1
1

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
0 Q (m 3/h)
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Q (m 33/h)
Q (m /h)

7
E rP
READY

OPTIMA
4/12 LOW ENERGY CONSUMPTION
SAVE the NATURE

Maximum Pumping Height [m] According to the pump type


Maximum Flow Rate [m3/h] According to the pump type
Motor Speed [rpm] 1.400 4.600
1~ 230 V AC %10, 50 Hz, PE
Input Voltage and Frequency (ground protected)
Rated Current [A] 2,5
Power drawn [W] 33 550
Energy Efficiency Index
< 0.23
(EEI)
Insulation Class F
Protection Class IP 44
Temperature Class TF 110
Maximum System Pressure PN 6/10 (1)
Sound Pressure < 56 dB (depends on the type)
Relative Humidity < %90
Weight 14 kg
1
Pump is suitable for use in both pressure values.

139
85.6
88

40 4x14 m

180
250 253.2

100

110

71.2 63.6
151
75.5 243
97.5 97.5

8
Variable Pressure Operating Mode
Variable Pressure Operating Mode
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5
13 0 0,5 1 1,5 2 2,5 3 3,5 Variable
4 Pressure
4,5 Operating
5 5,5
Mode
13
12 m1,5
12 0 0,5 1
12 m
2 2,5 3 3,5 4 4,5 5 5,5
13
12
11 m
11 12 m 11 m
12
11
10 m
10 11 m 10 m
11
10 9m
9 10 m 9m
10
9
8m
8 9m 8m
9
8
7m
7 8m 7m
(m)(m)

8
7
6m
6
H (m)H H

7m 6m
7
6 5m
5 6 m5 m
6
5
4m
4 5m 4m
5
4
3 4m
4
3
2
3
2
1
2
1
0
1
0 0 5 10 15 20 25
0 5 10 Q (m 3/h) 15 20 25
0 Q (m 3/h)
0 5 10 15 20 25
Q (m 3/h)

v (m/s) Fixed Pressure Operating Mode


0 0,5 1 1,5 2 2,5 v (m/s)3 3,5 Fixed
4 Pressure
4,5 Operating
5 Mode
5,5
13 0 0,5 1 1,5 2 2,5 v (m/s)3 3,5 4 Pressure
4,5 Operating
5 5,5
Fixed Mode
13 12 m
12 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5
12 m
13
12 11 m
11
12 m 11 m
12
11 10 m
10
11 m 10 m
11
10 9m
9
10 m 9m
10
9 8m
8
9m 8 m7 m
9
8
7
H (m)

8m7m6m
8
7
H (m)H (m)

6
7m 6m
7
6 5m
5 6m 5m
6
5 4m
4
5m 4m
5
4 3m
3
4 m3 m
4
3 2m
2
3m2m
1m
3
2
1
2 m1 m
2
1
0
0 5 10 15 20 1 m 25
1
0 Q (m 3/h)
0 5 10 15 20 25
0 Q (m 3/h)
0 5 10 15 20 25
Q (m 3/h)

Manual Operation Mode


0 0,5 1 1,5 2 2,5 3 3,5 4 4,5
Manual 5
Operation 5,5
Mode
13 4600rpm
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5
Manual Operation Mode
13 4600rpm
12
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5
13
12
11 4600rpm
12 4100rpm
OPTIMA 4/12

11
10
11
10 4100rpm
9
10 4100rpm
9
8
9
8
7 3350rpm
H (m)H (m)H (m)

8
7
6 3350rpm

7 3350rpm
5
6
2700rpm
6
4
5
2700rpm
5 2050rpm
3
4 2700rpm
4
2 2050rpm
3
1400rpm
2050rpm
3
1
2
1400rpm
2
0
1
0 1400rpm 5 10 15 20 25
1
0 Q (m 3/h)
0 5 10 15 20 25
0 Q (m 3/h)
0 5 10 15 20 25
Q (m 3/h)

9
E rP
READY

OPTIMA
5/8 LOW ENERGY CONSUMPTION
SAVE the NATURE

Maximum Pumping Height [m] According to the pump type


Maximum Flow Rate [m3/h] According to the pump type
Motor Speed [rpm] 1.400 4.800
1~ 230 V AC %10, 50 Hz, PE
Input Voltage and Frequency (ground protected)
Rated Current [A] 1,5
Power drawn [W] 10 350
Energy Efficiency Index
< 0.23
(EEI)
Insulation Class F
Protection Class IP 44
Temperature Class TF 110
Maximum System Pressure PN 6/10 (1)
Sound Pressure < 56 dB (depends on the type)
Relative Humidity < %90
Weight 12 kg
1
Pump is suitable for use in both pressure values.

113
75
102

50 4x14 m

170
240 204

110

125

67 53
166
83 233
54 94

10
v (m/s) Variable Pressure Operating Mode
9

8 8m

v (m/s) Variable Pressure Operating Mode


7m Variable Pressure Operating Mode
97 v (m/s)
9

86 8m 6m
8 8m

7 7m 5m
5 7m
7
H (m)

6m
6 4m
4 6m
6
5m
5 3m
5m
H (m)

3
5
H (m)

4m
4 4m
4
2
3m
3 3m
3
1
2
2
0
1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
1 Q (m 3/h)
0
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
0 1 2 3 4 5 6 7 8 9Q (m 310
/h) 11 12 13 14 15 16 17 18 19
Q (m 3/h)
Fixed Pressure Operating Mode
v (m/s)
0 0,5 1 1,5 2 2,5
9 Fixed Pressure Operating Mode
v (m/s) Fixed Pressure Operating Mode
0 0,5 1
8m v (m/s) 1,5 2 2,5
8 0
9 0,5 1 1,5 2 2,5
9
8m 7m
8
7 8m
8
7m
7 7m 6m
67
6m
6 6m 5m
56
(m)H (m)

5m
5 5m 4m
45
(m)
HH

4m
4 4m
4 3m
3
3m
3 3m
3 2m
2
2m
2 2m
2 1m
1 1m
1 1m
1

0
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Q (m 3/h)
Q (m33/h)
Q (m /h)

vv (m/s)
(m/s)
v (m/s) ManualOperation
Manual Operation
Manual Mode
Operation
Mode Mode
000 0.50.5
0.5 11 1 1.5
1.5 1.5 22 2
9
9
4800rpm
4800rpm
4800rpm
88
8

77
7
4100rpm
4100rpm
66 4100rpm
OPTIMA 5/8

6
55
(m)
HH(m)

5
H (m)

3400rpm
3400rpm
44
3400rpm
4
33 2700rpm
2700rpm
3 2700rpm
22
2000rpm
2000rpm
2
11 1400rpm
2000rpm

1 1400rpm
00
0 1 2 3 4 55 66 77 88 99 10
10 11
11 12
12 13
13 14
14 15
15 16
16 17
17
Q (m
Q (m33/h)
/h)
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Q (m 3/h)

11
E rP
READY

OPTIMA
5/9 LOW ENERGY CONSUMPTION
SAVE the NATURE

Maximum Pumping Height [m] According to the pump type


Maximum Flow Rate [m3/h] According to the pump type
Motor Speed [rpm] 1.400 4.100
1~ 230 V AC %10, 50 Hz, PE
Input Voltage and Frequency (ground protected)
Rated Current [A] 2,3
Power drawn [W] 40 505
Energy Efficiency Index
< 0.23
(EEI)
Insulation Class F
Protection Class IP 44
Temperature Class TF 110
Maximum System Pressure PN 6/10 (1)
Sound Pressure < 56 dB (depends on the type)
Relative Humidity < %90
Weight 15 kg
1
Pump is suitable for use in both pressure values.

139
89.3
103

50 4x14 m

200
280 253.2

110

125

80.6 65.2
166
83 247.6
107 107

12
Variable
VariablePressure
PressureOperating
OperatingMode
Mode
00 0,5
0,5 11 1,5
1,5 22 2,5
2,5 33 3,5
3,5 44
1010
9 9mm
99

8 8mm
88

7 7mm
77

66 6 6mm

5 5mm
H (m)
(m)
H (m)

55
H

4 4mm
44

33

22

11

00
00 55 1010 1515 2020 2525 3030
QQ(m(m
3/h)
3/h)
3

Fixed
FixedPressure
PressureOperating
OperatingMode
Mode
0 0,5 1 1,5 2 2,5 3 3,5 4
0 0,5 1 1,5 2 2,5 3 3,5 4
1010

9 9m
9 9m
8m
8 8m
8
7m
7 7m
7

6 6 6mm
6
H (m)

5 5mm
(m)
H (m)

5
5
H

44 4m
4m
3 3mm
33

2m
22 2m

1m
1 1m
1

0
0
00 55 1010 1515 2020 2525 3030
QQ(m(m
3/h)
3/h)
3

Manual
ManualOperation
OperationMode
Mode
00 0,5
0,5 11 1,5
1,5 22 2,5
2,5 33 3,5
3,5 44
1010
4100rpm
4100rpm
99

88
OPTIMA 5/9

77
3350rpm
3350rpm
66
H (m)

55
(m)
H (m)

2700rpm
H

2700rpm
44

33
2050rpm
2050rpm
22
1400rpm
1400rpm
11

00
00 55 1010 1515 2020 2525 3030
QQ(m(m
3/h)
3/h)
3

13
E rP
READY

OPTIMA
5/12 LOW ENERGY CONSUMPTION
SAVE the NATURE

Maximum Pumping Height [m] According to the pump type


Maximum Flow Rate [m3/h] According to the pump type
Motor Speed [rpm] 1.400 4.600
1~ 230 V AC %10, 50 Hz, PE
Input Voltage and Frequency (ground protected)
Rated Current [A] 3,3
Power drawn [W] 26 730
Energy Efficiency Index
< 0.23
(EEI)
Insulation Class F
Protection Class IP 44
Temperature Class TF 110
Maximum System Pressure PN 6/10 (1)
Sound Pressure < 56 dB (depends on the type)
Relative Humidity < %90
Weight 15 kg
1
Pump is suitable for use in both pressure values.

139
89.3
103

50
4x14 m

200
280 253.2

110

125

80.6 65.2
166
83 247.6
107 107

14
v (m/s) Variable Pressure Operating
v (m/s) Variable Pressure Operating ModeMode
00 0,5
0,5 1 1 1,51,5 2 2 2,5 2,5 3 3 3,5 3,5 4 4
1212 v (m/s) Variable Pressure Operating Mode
12 12
mm
11 11
m2m
1111
0 0,5 1 1,5 2,5 3 3,5 4
12 10 m
10 m
12 m
1010 11 m
11
10 m 9 m9 m
99
10
9m 8 m8 m
98
8
8m 7 m7 m
8 77
7m 6 m6 m
7 66
H (m)
H (m)

6m 5m5m
6 55
H (m)

5m 4m 4m
5 44
4m
4 33

32
2
21
1
10
0
0 5 10 15 20 25 30
0 0 5 10 15 20 25 30
0 5 10 Q (m 3/h)3
15 20 25 30
Q (m /h)
Q (m 3/h)

Fixed Pressure Operating Mode


Fixed Pressure Operating Mode
Fixed Pressure Operating Mode
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5
120 0 0,5 0,5 1 1 1,5 1,5 2 2 2,5 2,5 3 3 3,5 3,54 4
4,5 4,5
12 12
11 m
11
11 m 11 m
11 11 10 m
10 10 m 10 m
10 10
9m
9 9m 9m
9 9
8m
8 8m 8m
8 8
7 7m
7 7m
7 7m
H (m)

6m
6
H (m)

6m
6
H (m)

6m
6
5m
55 5m
5 5m
4m 4m
44
4 3m 34m
m
33 3m
3 2m 2m
22
2m
2 1m 1m
11
1m
00
1
00 5 5 10 10 15 15 20 20 25 25 30 30 35 35
0
0 5 10 Q 15
(mQ3/h) 3
(m /h) 20 25 30 35
Q (m 3/h)

Manual Operation Mode


v (m/s) Manual Operation Mode
v (m/s)
0 0,5 1 1,5 2 2,5 3 3,5 4 Operation Mode
Manual
13 0 0,5 1 1,5 2 v (m/s) 2,5 3 3,5 4
13 4600rpm
12 0
4600rpm 0,5 1 1,5 2 2,5 3 3,5 4
1213
11 4600rpm
1112
10
OPTIMA 5/12

4100rpm
1011
9 4100rpm
910
8 4100rpm
89
7
3350rpm
7
H (m)

6 8 3350rpm
H (m)

6
5 7
3350rpm
2700rpm
H (m)

5
4 6 2700rpm
4
3 52050rpm
2700rpm
2 3 4 2050rpm
1400rpm
1 23
1400rpm
2050rpm
01
02 5 10 15 20 25 30
0 1400rpm
10 Q (m 3/h)
5 10 15 20 25 30
Q (m 3/h)
0
0 5 10 15 20 25 30
Q (m 3/h)

15
E rP
READY

OPTIMA
6/12 LOW ENERGY CONSUMPTION
SAVE the NATURE

Maximum Pumping Height [m] According to the pump type


Maximum Flow Rate [m3/h] According to the pump type
Motor Speed [rpm] 900 3.300
1~ 230 V AC %10, 50 Hz, PE
Input Voltage and Frequency (ground protected)
Rated Current [A] 4,5
Power drawn [W] 30 1000
Energy Efficiency Index
< 0.23
(EEI)
Insulation Class F
Protection Class IP 44
Temperature Class TF 110
Maximum System Pressure PN 6/10 (1)
Sound Pressure < 56 dB (depends on the type)
Relative Humidity < %90
Weight 28 kg
1
Pump is suitable for use in both pressure values.

172
115
122

65
4x14 m

270
340 325

130

145

102.8 81.5
185
92.5 322
129 129

16
Variable Pressure Operating Mode
0 0,5 1 1,5 2 2,5 3 3,5
11 Variable Pressure Operating Mode
0 0,5 1 1,5 2 2,5 3 3,5
11 10 m
10
10 m
10 9m
9 Variable Pressure Operating Mode
9m
90 0,5 1 1,5 2 2,5 3 3,5
11 8 8m

10 m 8m
8
10 7m
7
9m 7m
97
6m
6
8m 6m
H (m)

86
5m
H (m)

5 7m
7 5m
5
6m
4m
6 4 4m
4
H (m)

5m
5 3
3
4m
4
2
2
3
1
1
2
0
10 0
0 55 1010 15 15 20 20 25 25 30 30 35 35 40 40 45 45

0 Q3(m
Q (m /h) /h)
3
0 5 10 15 20 25 30 35 40 45

Q (m 3/h)
Fixed Fixed Pressure
Pressure Operating
Operating Mode Mode
v (mv/s)
(m /s) Fixed Pressure Operating Mode

00 0,5 11 1,51,5 v (m2/s) 2,5 2,5 3 3,5 4 4,5


0,5 2 3 3,5 4 4,5
11
110 0,5 1 1,5 2 2,5 3 3,5 4 4,5
11
10 10
m m
10
10 10 m
10
9 9 m9 m
99 9m

8m 8m
8m
8 88
7m 7m
77 7m
7
6m 6m
66
6m
H (m)
(m)(m)

6 5m
5 5m
HH

5 5m
5 4m
4 4m
4 4m
3m
34 3m
3
23
2m 3m
2m
2 1m
1 2m
2 1m
0
1
1m
10 5 10 15 20 25 30 35 40 45 50 55
0
0 5 10 15 20 25 30 35 40 45 50 55
0 Q (m3/h)
0 5 10 15 20 25 30 35 40 45 50 55
Q (m3/h) Manual Operation Mode
v ( m/s)
0 0,5 1 1,5 2 2,5 3 3/h)
Q (m 3,5 4
11 Manual Operation Mode
3300 rpm v ( m/s)
10 0 0,5 1 1,5 2 2,5 3 3,5
Manual 4
Operation Mode
11 v ( m/s)
9 03300 rpm 0,5 1 1,5 2 2,5 3 3,5 4
11
10
3300 rpm
8
10
9 2700 rpm
7
OPTIMA 6/12

89
6
H (m)

2700 rpm
5 78
2100 rpm
4 67 2700 rpm
H (m) H (m)

35
6 1500 rpm
2100 rpm
2
4
5 900 rpm
1 2100 rpm
3
4 1500 rpm
0
20 5 10 15 20 25 30 35 40 45 50
3 Q (m3/h)
900
1500rpm
rpm
1
2
0 900 rpm
10 5 10 15 20 25 30 35 40 45 50
Q (m3/h)
0
0 5 10 15 20 25 30 35 40 45 50
Q (m3/h)

17
E rP
READY

OPTIMA
8/12 LOW ENERGY CONSUMPTION
SAVE the NATURE

Maximum Pumping Height [m] According to the pump type


Maximum Flow Rate [m3/h] According to the pump type
Motor Speed [rpm] 900 3.300
1~ 230 V AC %10, 50 Hz, PE
Input Voltage and Frequency (ground protected)
Rated Current [A] 7
Power drawn [W] 40 1.540
Energy Efficiency Index
< 0.23
(EEI)
Insulation Class F
Protection Class IP 44
Temperature Class TF 110
Maximum System Pressure PN 6 veya PN 10 (1)
Sound Pressure < 56 dB (depends on the type)
Relative Humidity < %90
Weight 31 kg
1
Different pumps are available for different pressure values.

138
80 4x18 m

172
122.3

180

200

271
360 325

138
80 8x18 m

115 90.9
100 350.5
142 142

160

200

18
v (m/s) Variable Pressure Operating Mode
13
12 m v (m/s) Variable Pressure Operating Mode
12
13 11 m
11 12 m
12 10 m
11 m
10
11 9m
10 m
9
10 v (m/s) Variable Pressure Operating Mode
13 9m 8m
8
9 12 m
12 7m
8m
7
8 11 m
11
10 m 7m 6m
H (m)H (m)

106
7
9m 6m 5m
6
95
8m 5m 4m
85
4 7m
7 4m
4
3 6m
H (m)

6
3
2 5m
5
2 4m
41
1
30
0 5 10 15 20 25 30 35 40 45 50 55 60
20
0 5 10 15 20 25 30 3
Q (m /h) 35 40 45 50 55 60
1
Q (m 3/h)
0
0 5 10 15 20 25 30 35 40 45 50 55 60 Fixed Pressure Operating Mode
Q (m 3/h) v (m/s) Fixed Pressure Operating Mode
v (m/s)

0 0,5 1 1,5 v (m/s) 2 Fixed Pressure Operating


2,5 3 Mode 3,5 4
13 0 0,5 1 1,5 2 2,5 3 3,5 4
13
12 m
120 0,5 1 1,5
12 m 2 2,5 3 3,5 4
12
13 11 m
11 m
11
12
12 m
11 10 m
11 m 10 m
10
11
10 10 m
10 9m9m
99
9m
9 8m 8m
88 8m
8
7m 7m
7 7m
(m)

7
H(m)

6m 6m 6m
66
H

5m 5m 5m
55
4m 4m
44 4m
4
3m
3 3m 3m
33 2m
2 2m
2 1m
2m
12
1m
1 1m
01
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
0
0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
Q (m 3/h)

Q (m 3/h)
Q (m 3/h)

Manual Operation Mode

0 0,5 1 1,5 2 2,5 3


14 Manual Operation Mode
13 3300 rpm Manual Operation Mode
0 0,5 1 1,5 2 2,5 3
12
14 0 0,5 1 1,5 2 2,5 3
11
14 3300 rpm
13
10 3300 rpm
13
OPTIMA 8/12

12
9 2700 rpm
12
11
8
H (m)

10
11
7
69
10 2700
2100 rpm
rpm
58
9 2700 rpm
H (m)H (m)

4
87 1500 rpm
3
6
27 2100 rpm
5 900 rpm
16
4
2100 rpm
05
0 1500 5rpm 10 15 20 25 30 35 40 45 50 55 60
3
4 Q (m 3/h)
2 1500 rpm
3 900 rpm
1
2
0 900 rpm
1 0 5 10 15 20 25 30 35 40 45 50 55 60
Q (m 3/h)
0
0 5 10 15 20 25 30 35 40 45 50 55 60
Q (m 3/h)

19
MODE OPTIONS TABLE

Variable Pressure Constant Pressure

H
ma H
ks
im ma
um
rot ks
a im
tio Hsetting um
Hsetting ns rot
pe a
ed tio
ns
pe
ed

Hsetting/2

Q Q

Total friction loss > 4mSS


Total friction loss < 2mSS
Extremely long circulation line
Heating Systems with Two Pipes and Short and large diameter circulation
High friction loss
Thermostatic Valve lines
Pressure stabilizing valve use
Low friction loss
Excessively tightened branch valves

Systems with thermostatic valve


Heating Systems with Single Pipe Systems with thermostatic valve and
pressure stabilizing valve

High friction loss


Underfloor Heating Systems Systems with thermostatic valve
Pressure stabilizing valve use

Secondary circulation circuit Primary circulation circuit


Heating Systems with
High friction loss Low pressure loss
Condensing Boiler
Pressure stabilizing valve use Natural circulation

POWER CABLE OPTIONS TABLE


Motor Power Cable Section (mm2)
NOMINAL VOLTAGE
kW HP 4x1.5 4x2.5 4x4 4x6 4x10
0,37 0,5 80 133 212 316 520
0,55 0,75 58 95 150 226 372
MONOPHASE
0,75 1 42 69 110 164 271
220 V
1,1 1,5 35 55 91 136 164
1,5 2 25 41 66 98 121

WARANTY
The right to amend specifications under technologic developments is reserved

GOSB-Gebze Organize Sanayi Blgesi


A.7.1.8 i 011215 MNERAL

ahabettin Bilgisu Cad. 41480 Gebze-Kocaeli/TURKEY


Phone : (90)(262) 648 60 00 PBX
Telefax : (90)(262) 648 61 01
web : www.alarko-carrier.com.tr
ALARKO CARRIER
SANAY VE TCARET A.. e-mail : info@alarko-carrier.com.tr

You might also like