You are on page 1of 1

0.60 M.

LEGENDS & SYMBOLS


WC WATER CLOSET 0.025 0.55 0.025

LAV LAVATORY
Fau FAUCET 0.60 M.

WT HB HOSE BIB 0.025 0.55 0.025

0.60 M.
FD FLOOR DRAIN

VTR VENT THRU ROOF

0.10
0.15
V VENT
CV CHECK VALVE
0.50 M.
GT GATE VALVE

WM WATER METER PLAN SECTION


KS KITCHEN SINK
DETAIL OF MANHOLE
RW PT SD SHOWER DRAIN
DS DOWN SPOUT
CB CATCH BASIN
WT WATER TANK
FILTRATION ultra violet RW RAW WATER
3/16'' x 1'' ANGLE BAR
4'' THK. R.C. SLAB

32.5 100
UV ULTRAVIOLET
PT PRODUCT TANK
150MM THICK
EXTERIOR WALL
Fau GENERAL PLUMBING LAYOUT AND DETAILS 4" DIA. PVC PIPE

670
10MM DIA. REBARS

550
NOTES :
4'' DIA. PVC PIPE
Intersecting plumbing lines without "tick" marks denoting/
DP OUTLET
Fau Fau Fau SEPTIC TANK
suggesting pipe fitting has no connection. Only lines with " tick "
mark shall be interpreted having such connection.
Air chamber symbol, denoted as AC at every end of a water

CR line suggests AC at every end of fixture instead or where Water


hammer would likely occur due to dense fixtures connected

100
along a considerable pipe size or length.
4" THICK CHB
Plumbing lines are suggestive of line location, it does not
limit in situ conditions, however its general location must be DOWN SPOUT
observed. For Actual on site plumbing lines, as built plans shall

WT
be prepared for maintenance and repair as well as future reference.
Plumbing lines without " tick " / fitting notation implies no
significance in plumbing line direction. They could just be drawn
to imply connectivity and not general location nor direction.
et-nick notes

The undersigned Master Plumber or Sanitary Engineer shall approve


P PLUMBING DETAILS
1 WATER LINE LAYOUT the size of septic tank and plumbing lines with his Sign and Seal
below and/or his signature with handwritten revisions on this plan. NOT TO SCALE

1:50 m.
P-1 SCALE

CAP
ASA 40-9A PIPE
SIZE 2"BY ASA NUMBER DEPTH WIDTH LENGTH
PIPE CLAMP
TOILET FINISH FLOOR LINE
METAL OR APPROVED
EQUAL OF "D" "W" "L"

300
AIR CAPPED
PIPE SLEEVE
CHAMBER
PERSONS METERS METERS METERS
CB PIPE HANGER
W/ REDUCER
CAULK SEAL
10 PERSONS 1.20 0.90 1.80
ANCHOR
BOLT

150
CAULKING

TEE TO FIXTURE PIPE HANGER


15 PERSONS 1.20 1.10 2.20
PIPE
20 PERSONS 1.20 1.25 2.50
FD
RW PT AC
AIRCHAMBER
FDN
FLOOR DRAIN
25 PERSONS 1.20 1.40 2.50

30 PERSONS 1.30 1.50 3.00

5'' THICK CHB 35 PERSONS 1.30 1.60 3.20


SWAY BRACE WALL
160 240

PVC VENT
40 PERSONS 1.40 1.65 3.30
FILTRATION STACK

PIPE CLAMP 45 PERSONS 1.40 1.75 3.50


CB MSWV 50 PERSONS 1.50 1.75 3.50

13
PIPE SLEEVE
CLEAN OUT
60 PERSONS 1.50 1.95 3.90
FD PVC SEWER PIPE
70 PERSONS 160 2.00 4.00

80 PERSONS 160 2.20 4.40


CO
COUPLING REDUCER 90 PERSONS 1.80 2.20 4.40
SINK STACK PIPE DETAIL
CLEANOUT
PIPE

SINK 100 PERSONS 1.80 2.30 4.60

2.50 MANHOLE MANHOLE 4" CO


CB 0.50 0.50
4" CO 4" CO

0.30
FIREWALL

0.30 M. AIR SPACE


4" CO 4" CO 4" INLET 4" OUTLET
4" OUTLET
DIGESTIVE LEACHING

1.20

1.20
0.50
1.50
4" CO CHAMBER WELL
MANHOLE MANHOLE

0.20
0.10 M. THK. REINFORCED
0.20
4" INLET CONCRETE SLAB WITH 10 MM. DIAM.
REBARS @ 0.15 M. ON CENTER,
BOTHWAYS GRAVEL FILL
5" THK. CHB MASONRY WALL WITH 0.20 M. THK. REINFORCED 3-10 MM. DIAM. LONGITUDINAL
10MM. DIAM. VERTICAL BARS @ 0.80 M.
CONCRETE SLAB WITH 10 MM. 0.40 BARS WITH 10 MM. DIAM. TIES @
& 10MM. DIAM. HORIZONTAL BARS @
DIAM. REBARS @ 0.30 M. ON 0.30 M. ON CENTER
2 S E W E R L I N E L A Y O U T 0.60 M. ON CENTER
CENTER, BOTHWAYS
1:50 m.
P-1 SCALE

R.A. 545 :
SANITARY ENGINEER PROJECT TITLE: OWNER: SHEET CONTENTS: SHT.
DRAWINGS AND SPECIFICATIONS DULY SIGNED, STAMPED
OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE
PROPERTY AND DOCUMENTS OF THE ARCHITECT AND
NO.:
ENGINEER, WHETHER THE OBJECT FOR WHICH THEY ARE PROPOSED COMMERCIAL Mr. Wilfredo B. Bose P - 1
Engr. Demetrio B. Baluga MADE IS EXECUTED OR NOT. IT SHALL BE UNLAWFUL PLUMBING LAYOUT PLANS
FOR ANY PERSON, WITHOUT THE WRITTEN CONSENT OF
THE ARCHITECT/ENGINEER, TO DUPLICATE OR MAKE
BUILDING
COPIES OF SAID DOCUMENTS FOR USE IN THE
P.T.R. No. : ISSUED ON : REPETITION OF AND FOR OTHER PROJECTS OR DRAWN : CHECKED :
BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE.
Brgy. Maguyepyep Sallapadan, Abra Brgy. Maguyepyep Sallapadan, Abra
R.E.G. No. : 1589 ISSUED AT : DESIGNED : DATE :