DATA SHEET FOR ACTUATOR WITH INTEGRAL STARTER ON-OFF DUTY

S.no Description Unit Data Unit Data


1 Manufacturer Auma India
2 Actuator Model *VTP
3 Actuator torque Nm *VTP
4 Torque Range of actuator *VTP
5 Actuator Speed rpm *VTP
6 Type of service On-Off duty
7 No. of turns / Operating time *VTP
8 Duty S2-15 min
9 No. of Starts per Hour (Max) 60 starts/hr for on-off
10 Enclosure IP67
11 Motor type & reference standard Squirrel cage induction motor & IS325
12 Rated Voltage and Frequency 415 Volts, 50 Hz, 3Ph, AC
13 Admissible Voltage Fluctuation % + / -10
14 Admissible Frequency Fluctuation % + /- 5
15 Admissible Voltage and Frequency Variation % 10 (absolute)
16 Insulation Class F class with temp rise limited to class B
17 Admissible ambient temperature deg C -20 to +80
18 Cable Gland (Double Compression) 3XM25X1.5
19 Lubrication Grease EP0 Servogem
20 Limit switches 2 nos. 2NO+2NC contacts (1 for OPEN & 1 for CLOSE)
21 Torque switches 2 nos. 2NO+2NC contacts (1 for OPEN & 1 for CLOSE)
22 Rating of switches 5A/0.5A at 250V AC/DC
23 Thermo-switches 3 nos. ( One in each winding)
24 Local Position Indication Continuous Local Mechanical Position Indicator
25 Space Heater 110 V Single phase AC (internally generated)
26 Motor nominal output KW *VTP
27 Frame size *VTP
28 Nominal current A *VTP
29 Starting Current A *VTP
30 Full load speed rpm *VTP
31 Power factor cos *VTP
32 Full load efficiency *VTP
33 Paint Shade Epoxy Paint, Smoke Grey (692 as per IS 5)
34 Terminal Plan No. /Wiring Diagram *VTP
35 Remote control/PLC provision Required
36 Weight of Actuator (Approx) *VTP

*VTP Vendor to provide