Professional Documents
Culture Documents
THE PRINCIPAL,
P.S.R. ENGINEERING COLLEGE,
SEVALPATTI,
SIVAKASI,
VIRUDHUNAGAR DIST - 626 140.
Dear Sir,
As desired by you, we are pleased to enclose our QUOTATION for your favorable
consideration.
We believe that you will find our offer as quite attractive and cost effective to your needs.
Incase you require any further clarifications or details please do feel free to contact us.
Yours faithfully,
For Vi Micro systems Pvt. Ltd.,
AUTHORISED SIGNATURE
Ref: V17/QTN/1886 Dated : 22-Nov-2017
THE PRINCIPAL,
P.S.R. ENGINEERING COLLEGE,
SEVALPATTI,
SIVAKASI,
VIRUDHUNAGAR DIST - 626 140.
QUOTATION
1. dSPIC 33EP814 BASED CONTROLLER (VPE 33EP)
Processor : dsPIC33EP512MU814
Operating Speed : 60MHz
512KB on-chip Flash Program Memory
52KB on-chip Data Memory
Opto isolated USB Serial Port
20 x 4 Alpha Numeric LCD Display
34 pin Motor control I/F connector
# 16 PWM outputs
# 8 capture I/P signals
26 pin ADC I/F Connector
16 channel 12 bit ADC
500ksps conversion rate
4 channel 12 bit DAC terminated at J801 connector
On-Chip Features:
Memory:
On-chip ADC:
Additional Features
* 16 user definable LEDs & On board RS-232 connector with line driver
* 3 Switches are provided for user interface link frequency speed variations etc.,
* ADC Inputs are protected and terminated at 26 pin FRC Connector
* PWM Outputs and capture inputs are terminated at 34 pin FRC Connector
* I/O lines are protected and terminated at 50 pin FRC Connector
* JTAG interface connector provided
What's Included
A full pledged trainer for SCADA based Electrical Power Transmission Line Simulator with 2
artificial Transmission Line Modules for detailed study of i) Power Generation ii) Transmission
Line iii) VAR Compensation iv) Measurement & Protection v) Loading vi) Monitoring &
Control by SCADA.
The transmission line which is considered of 180KM long. The line may be used as 180KM, 3
line or 540 Km 1 line. The 180 KM line is divided into 6 sections. Each section is 30KM
long. The line inductance is taken for every 30 Km and capacitance for every 15 KM. The power
carrying capacity of the transmission line is 1000 VA (1KVA)
Specification
* Type : Artificial Transmission line
3Phase Bench Model.
* No. of Pi Sections : 18nos.
* Operating Voltage : 415V, Line to Line.
* Current Rating : 2.5A
* Short Circuit Rating : 5A
* Voltage rating : 600V P-P(Max)
This 2nd Artificial Transmission line is provided for studying the Power Flow Management
between two Transmission lines by disconnecting the 1st transmission line which drives the
Emergency Load during fault condition and the corresponding load in driven by 2nd
Transmission line through Emergency transfer switch.
This consists of shunt capacitors for voltage control and series reactor to reduce the fault
current at the time of occurrence of fault
Specification
Measurements of Sending end Voltage, Current, Power and Power factor etc.
Measurements of Receiving end Voltage, Current, Power and Power factor etc
Measurements of ABCD constants
Protection relays (Over Current, Over / Under Voltage,) are available.
PC interface facility (Optional)
Shunt capacitor: 3 delta connected shunt capacitor of 1KVAR Compensation under
loading condition
Shunt reactor with variable inductor available for compensation under no load
condition.
Series reactor with variable inductor available in all the three phases for series
compensation to improve the system stability
The receiving station is provided with a Step Down Transformer. It is provided with ON /
OFF switch, representing the circuit breaker in real system, two numbers of receiving
station module are provided for two Transmission lines.
All the Switching Circuits are connected to SCADA via PLC, so that switchover will be
automatic under various fault conditions.
This consist of
The PLC with MODBUS Communication can interface with all the Intelligent Electronic
Devices (IEDs) which in turn can be connected to SCADA Software as Distributed
Control System for better monitoring and controlling.
Make : Siemens,
Model : CPU 1212C DC / DC / DC
PLC : S7-1200
Bit processing speed 0.1 micro
Ethernet communication interface (TCP/IP Native, ISO on TCP)
In built Real Time Clock
This PLC acts as Master for Serial Communication in MODBUS Protocol
MODBUS is used to communicates Master (PLC) and Slaves (RTU)
Wincc Flexible 2008 SP3 has been used for developed the graphical representation,
Analysation & control for process in SCADA
To study SCADA principle simatic its applications in Power Systems we offer most
popular Supervisory Control (SCADA) package Simatic WinCC Flexible from
SIEMENS. This is very rich in feature and offers all drivers to interface with any PLC
available in the market.
The SCADA software can access all data from PLC through Ethernet where PLC
communicates with RTU device through MODBUS protocol
Ferranti Effect
ABCD Parameters & Power Circle Diagram (Practically through OC & SC Test)
Surge Impedance Loading
Study of Voltage Regulation, Losses and Efficiency
Study of Voltage Drop at Receiving End (Due to R-Load)
Shunt Reactor Compensation
Shunt Capacitor Compensation (Line Side Compensation)
Shunt Capacitor Compensation (Load Side Compensation)
Series Reactor Compensation
Study of Earth Fault Relay
Study of Under / Over Voltage Relay
Study of Over Current Relay
Study of Voltage Drop at Receiving End (Due to L-Load)
Study of Power Flow Management in Transmission Line
Study of Synchronizing Relay
Under / Over voltage Relay using Measurement & Protection Section (Optional)
Over Current Relay Using Measurement & Protection section (Optional)
Shunt capacitor compensation (Line Side & Load Side) of Transmission Line-2
Note: All the above mentioned experiments can also be performed by SCADA except
ABCD Parameters, Power Circle Diagram and Protection Relays
ARM Cortex M4 based Wi-Fi Node to connect to the above internet to a cloud server/PC
Inverted pendulum system is nonlinear unstable system, an ideal experiment platform for
teaching control theories and conducting various control experiments. Many abstract control
concepts such as the stability and the controllability of a control system can all be shown visually
through the inverted pendulum system. In addition to educational purposes an inverted pendulum
is also a research area for many researchers of modern control theories.
Details as below:-
a. Inverted Pendulum Mechanical setup
24V / 1.5A DC motor for actuating the Mechanical Pendulum
30cm diameter swing length
20grms weight of pendulum
Height of Mechanical setup: 25cm
b. Power Driver for Mechanical setup
MOSFET Based Power DC Drive
4 MOSFET forms H-Bridge driver
4 Nos of High speed opto coupler and driver circuit
Current sensing circuit to protect the drive
In built power supply, power ON/OFF switch
d. Feedback Sensors
NOTE:
FEATURES:-
* Ideal for demonstrating the basic principles of linear motor operation
* Movable vehicle mounted on bearing rollers for smooth motion
* Open construction of the moveable vehicle to facilitate observation of the laminated
iron core and windings
* Current Controlled output to the vehicle
* Model : PEC16LM01- E
* Type : Three Phase , 50Hz
* Power : 0.5 KW
* Voltage : 210V AC (DELTA /STAR)
* Track length : 2 meter
* Sensor : 2 No.(for home & end)4No.for Distance,
force measurement with different length
* Make : Vimicro
AUTHORISED SIGNATURE
GSTIN: 33AAACV0909J1ZJ