You are on page 1of 2

Azza

4 6 4 3
A B C

Mu = 3AB Mu = 364 kNm


Fc = 3B Fc = 34 Mpa
Fy = 4BC Fy = 443 Mpa
b = 3CA b = 336 mm
h = 6AC h = 663 mm
d = 613 mm
d' = 62.5 mm
cover = 50 mm
c = 95 mm

#1 Calculate c < 0.75 cb

c < 0.75 cb = 0.75 x 600 x d


600 + Fy

= 0.75 x 600 x 613


600 + 443

= 264 mm

#2 Calculate As1 with c determined from above c = 95 mm

Bi = 0.85 - Fc - 30 x 0.05 > 0.65


( 7 )
= 0.85 - 34 - 30 x 0.05 > 0.65
( 7
)
= 0.821

a = Bi x c

= 0.821 x 95

= 78.04 mm

As = 0.85 x Bi x F'c x c x b
F'y

= 0.85 x 0.821 x 34 x 95 x 336


443

= 1711 mm2

#3 Calculate Mn1

Mn1 = As x F'y d - a
( 2 )
= 1711 x 443 613 - 78.04
( 2 )
= 434.94 kNm

#4 Calculate Mn-Mn1

Mu - Mn1 = 364 - 434.940


0.8

= 20.06 kNm > 0


Perlu Tulangan Tekan

#5 Tulangan Tekan diperlukan, Hitung T2

Cs' = T2 = Mn - Mn1
(d - d') d' = cover + (D Tul. Tekan)

6
= 20.060 x 10
613 - 62.5

= 36440 N
#6 Kontrol tegangan leleh tulangan tekan

fs = 1 - d' 600
( c )
= 1 - 62.5 600
( 95 )
= 205 Mpa < F'y = 443 Mpa
Tulangan Tekan Belum Leleh

#7 Hitung kebutuhan tulangan tekan

As' = Cs'
( fs' - 0.85 x F'c )

As' = 36440
( 205 - 0.85 x 34 )

As' = 207 mm2

#8 Hitung tulangan tarik tambahan

Ass = T2 = 36440
F'y 443
= 82 mm2

#9 Calculate Required Reinforcement

As = 1711 + 82 mm2

= 1793 mm2 Dipakai 4 D 25 = 1963

As' = 207 mm2 Dipakai 1 D 25 = 491

Check S > 4 cm
As S = b - D
n + 1
S = 336 - 25
4 + 1
S = 4.22 cm > 4 cm
OK

Check S > 4 cm
As' S = b - D
n + 1
S = 336 - 25
1 + 1
S = 14.3 cm > 4 cm
OK

#10 Check The Moment Required

a = As x F'y - As' x fs
0.85 x F'c x b

= 1963 x 443 - 491 x 205


0.85 x 95 x 336

= 79.18 mm

Mn = 0.8 x As x F'y - As' x fs x d - a + As' x fs x d - d'


2

= 0.8 x 1963 x 443 - 491 x 205 x 613 - 79.18 + 491 x 205 x 613 - 62.5
2

= 397.07 kNm > Mu = 364 kNm OK