1. Paulay, T. and Priestley, M. J. N., Seismic Design of Reinforced Concrete and Masonry
Buildings, Wiley, Section 3.6.
2. ATC, Seismic Evaluation and Retrofit of Concrete Buildings, Report ATC-40, Applied
Technology Council, Redwood City, California.
3. FEMA, Prestandard and Commentary for the Seismic Rehabilitation of Buildings, Report
FEMA 356, Federal Emergency Management Agency, Washington, D.C
The key steps in the IBC force-based seismic analysis of reinforced concrete framed buildings are
enumerated below:
1. Develop trial sizes of beams and columns using hand calculations; estimate the reactive weight at
each floor level
2. Develop a mathematical model of the building frame using the sizes of step 1
4. Calculate the design base shear V using the first mode period from step 3 (as modified by the
IBC) as
PSa (T , )W
V=
R
5. Distribute the base shear force over the height of the building using
wx hxk
Cvx = n
k
wi hi
i =1
where k is equal to 1 for periods less than or equal to 0.5 second and 2 for periods greater than 2.5
seconds, and
Fx = CvxV
Lecture 15 Page 1
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
6. Apply the lateral forces Fi in conjunction with the gravity loads and (after using load factors)
calculate design actions (forces) in all components.
8. Design components for the actions of step 6 and apply prescriptive details of ACI 318.
Values for R and Cd from the IBC for reinforced concrete frames are presented below. In CIE 525,
attention is focused on the special reinforced concrete moment frame.
R 0 Cd
Lecture 15 Page 2
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
Chapter 21 of ACI 318 provides guidance for the design and detailing of components (beams, columns,
joints, and walls) in seismic lateral-force-resisting systems.
ACI 318 writes rules regarding acceptable concrete strengths and rebar types for earthquake-resisting
construction, namely,
f c 3000 psi
Rebar shall conform with ASTM A706 unless tight quality control on ASTM A615 such that:
No welded splices in the critical regions (twice member depth from column or beam face)
ACI 318 writes rules for beams in SMRFS. What are beams?
3
b 10; bcol + 2( db ) for good moment transfer to the column
4
Prescriptive detailing requirements are used in lieu of requiring calculations for determining deformation
capacity in critical regions.
Lecture 15 Page 3
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
200
0.025
fy
Ductility is provided through compression rebar and confinement. The limit of 0.025 is to avoid rebar
congestion and recognizes that balanced failure cannot be defined once members undergo inelastic load
reversals.
At least two bars continuous top and bottom of the beam. Why?
No lap splices within 2d either side of a section where hinging can occur or in joints. Where in
the above beam?
If lap splice in a beam, splice must be enclosed in hoops or spirals with a maximum spacing of 4
in. or d/4.
Limits are also set on the placement of transverse reinforcement. What is the purpose of the transverse
reinforcement?
Shear reinforcement
Confinement
Lecture 15 Page 4
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
In the region a distance 2h either side of a plastic hinge region, except only on one side at joints,
smax d / 4
8d b
24dtie
12
smax d / 2
Lecture 15 Page 5
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
Plastic shears: shear due to development of nominal moment capacities at member ends and
f s 1.25 f y
In a plastic hinge zone, the contribution of the concrete to the shear resistance, vc , is set equal to 0.
Indirect way of requiring more shear reinforcement in regions subjected to cyclic nonlinear
deformations
Reinforced concrete SMRFs are expected to form plastic hinges during design earthquake shaking. In the
frame below, plastic hinges are shown at the ends of the beams and at the column bases. If we also
assume that all of the frame deformation during an earthquake is plastic deformation
e << p and t = e + p p
then the plastic rotation at each hinge ( p ) can be related to the total displacement t as
p h = t
and so, if the maximum roof displacement is known in the design earthquake, the maximum beam plastic
rotation can be estimated.
Lecture 15 Page 6
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
Consider first the actual and idealized moment-curvature relationships shown in the figure below. How
can this information be used to calculate maximum rotation capacities of critical connections?
Lecture 15 Page 7
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
Consider now the cantilever beam shown below for which the moment and curvature diagrams are shown.
The shaded area represents the plastic rotation that occurs in addition to the elastic rotation at the ultimate
stage of the beam. The inelastic area at the ultimate stage can be replaced by an equivalent rectangle of
height ( u y ) and width l p , having the same area as the actual inelastic curvature distribution.
l p is the plastic hinge length over which the plastic curvature is assumed to be constant
Lecture 15 Page 8
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
The plastic rotation to the left of the fixed end can be calculated as
p = (u y )l p
So, if the plastic hinge length is known (see below), the maximum roof displacement t has been
estimated, and the moment-curvature relationships established for the beams and columns (including the
effects of confinement), the maximum curvature demand on the cross sections can be established. The
task then is to ensure that max u for each hinging component.
The subject of plastic hinge length has been studied (and studied and studied). The concept of a plastic
hinge is introduced to simplify calculations and nothing else. Values and expressions for l p have been
back calculated from experimental data.
l p = 0.5h
where h is the member depth. Such an assumption should be used for calculating rotation capacities but
not for the length over which confinement reinforcement is to be placed.
ACI 318 writes rules for columns in SMRFS. What are columns?
bmin 12
bmin
0.4
bmax
As
0.01 g = 0.06
Ag
Lower limit (0.01) is to control time-dependent deformations (creep) and to have M y > M cr
Lecture 15 Page 9
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
Upper limit (0.06) is to limit rebar congestion and plastic shears in columns
To limit inelastic flexural deformation in columns, the sum of the column nominal flexural strengths shall
exceed the sum of the beam nominal flexural strengths (in the plane of the beam) at a beam-column
connection, that is,
M nc > M nb
Column axial load that gives the minimum column-moment strength. How to calculate? See
below.
What effective width? For interior beams, ACI 318 writes beff b + 16t f ; l2
If the above rule is not satisfied, ACI writes that special transverse reinforcement is required
over the full height of the column
Column axial load that gives the minimum column-moment strength. How to calculate?
No guidance given on slab width but consider the data of Kurose et al. (SP-123, p 39)
Lecture 15 Page 10
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
94
At 2% drift for J2, beff = b + 2(0.7 )t = b + 26t f
5 f
94
At 4% drift for J2, beff = b + 2(0.9 )t = b + 34t f
5 f
Consider now the generic column below (different details may be required if the column serves as a
boundary element)
l0
Lecture 15 Page 11
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
Special transverse reinforcement is required along length l0 from each joint face, where
l0 hmax
ln
6
18
Special transverse reinforcement should be provided over a longer height at the bases of the first story
columns as shown above
Calculate the plastic shear assuming nominal flexural strengths at ends of columns
Lecture 15 Page 12
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
The ACI rules for special transverse rebar are To ensure that post-spalling
strength exceeds pre-spalling
strength
Ag f c f c
For spirals, s 0.45( 1) 0.12
Ac fy fy
Lecture 15 Page 13
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
s 0.25bmin
6db
14 hx
sx = 4 + ( );4 s x 6
3
ACI Committee 352 provides information to the code-writing committees on the design of beam-column
joints for gravity and seismic actions. The report ACI 352R-91, Recommendations for the Design of
Beam-Column Joints in Monolithic Reinforced Concrete Structures, is the current ACI report on the
beam-column joints.
Type 1 for non-seismic applications: joint connects members designed to satisfy ACI 318
requirements and in which no significant inelastic deformations are expected
Type 2 for seismic applications: joint which connects members designated to have sustained
strength under deformation reversals into the inelastic range
and
Exterior: at least two horizontal members framing into opposite sides of the joint
To count as confinement as an exterior or exterior joint, a beam framing into a face must cover at least
75% of the column width. Sketches of the three joint geometries follow:
Lecture 15 Page 14
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
The basis steps in the design and detailing of beam-column joints follow the same general approach,
namely,
Experimental observations indicate that joint shear strength is fairly independent of the volume of
transverse reinforcement if minimum amounts are provided. This is the basis of the detailing procedures
in US codes. Consider the data from Kitayama et al. in SP-123 for interior joints:
Lecture 15 Page 15
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
These data suggest that there is no increase in joint shear strength for substantial increases in the joint
lateral reinforcement ratio, beyond 0.4%.
Lecture 15 Page 16
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
How are joint demands calculated? Consider the interior beam-column joint shown below:
Vcol
1.25 As f y
?????
Vj
Should slab contributions to the strengths of the beams be considered to estimate the demand on a beam-
column joint?
ACI 318 assumes that if the column rebar is correctly designed, stresses in the vertical
reinforcement should be less than f y and that the reserve strength in the reinforcement can serve
the function of vertical joint shear reinforcement.
ACI 318 and ACI 352 provide equations for the strength of beam column joints as follows:
Vu = Vn = 0.85[ f cb j h]
where values for are given in the table below, h is the depth of the column in the direction under
consideration, and b j is the joint width, which is defined below.
1 24 20 15
2 20 15 12
Lecture 15 Page 17
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
For Type 2 joints, the special transverse reinforcement in the column ends must be continued through the
beam-column joint as shown below. No specific calculation for the volume of joint shear reinforcement is
needed.
For interior joints meeting specific requirements, special transverse reinforcement can be reduced
by 50% from that in column ends
Lecture 15 Page 18
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
ACI 318 also writes rules for anchorage of beam reinforcement in a Type 2 beam-column joint, namely,
The diameter of straight bars in a beam-column joint should be smaller than 5 percent of the
column dimension in the direction, that is,
h
20
db
Note that this will not prevent slip of the beam bars in the joint. To prevent such slip,
h / db 32 , which would result in very large joints.
For hooked bars, the required development length ldh for a bar with a standard 90-degree hook
must be provided
db
ldh
A number of models have been developed for force transfer in beam-column joints. The two most popular
models are the
Truss model: assumes perfect bond of rebar in joint and assumes all forces are transmitted to the
joint by longitudinal reinforcement.
Diagonal strut model: assumes no bond of rebar in joint; force is applied as a compression force
in concrete on opposite side of joint.
Lecture 15 Page 19
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
Truss model
Forces are transferred across the joint for the two models as shown below in a figure from the text of
Paulay and Priestley:
Lecture 15 Page 20
CIE 525 Reinforced Concrete Structures Instructor: Andrew Whittaker
An alternate model is the strut-and-tie model shown below. This approach permits the user to select the
load path: one approach is to assign all forces in longitudinal reinforcement to a truss mechanism, and all
compression in the flexural compression zone to a single strut.
Which approach is correct? No single load-transfer mechanism is correct for all levels of applied load.
True mechanism is likely a combination of the diagonal strut and truss models (or the strut-and-tie model)
shown above.