You are on page 1of 7

SENSIBILIDAD DE LA ALTURA DEL MECHURRIO CON RESPECTO A "K" EN LA BASE

INTENSIDAD DE CALOR RADIA- DISTANCIA A PARTIR DEL CENTRO DE LA LLAMA ALTURA DEL ME-
DA POR LA LLAMA(BTU/h-pie2) (pies) CHURRIO (m)
1000 281 48
1200 257 40
1300 247 37
1400 238 35
1500 230 32
1600 222 30
1700 216 28
1800 210 26
1900 204 24
2000 199 23
2100 194 21
2200 190 20
2300 185 19
2400 181 17
2500 178 16
2600 174 15
2700 171 14
2800 168 13
2900 165 13
3000 162 12
MENSERCA
HOJA DE CLCULO PARA EL DIMENSIONAMIENTO DE FLARE

PROYECTO: ING CONCEPTUAL "ADECUACIN DE LA ESTACION DE DESCARGA GUARA-2"


O.D.I:
TAG:
CONTINGENCIA:

"DATOS"
CAUDAL DE GAS (MMPCED) 46.00
PESO MOLECULAR DEL GAS 19.73
TEMPERATURA DEL GAS EN EL MECHURRIO (R) 540
RELACIN DE CALORES ESPECFICOS( K=Cp/Cv) 1.2
PRESIN DEL GAS EN EL TIP(psia) 14.696
DENSIDAD DEL GAS @ T y P (lb/pie3) 0.0505
FACTOR DE COMPRESIBILIDAD DEL GAS @ T y P 0.9900
NMERO DE MACH EN EL TIP 0.3
CALOR DE COMBUSTIN DEL GAS (BTU/Lb) 21000
VELOCIDAD DEL VIENTO (pies/seg) 20
VELOCIDAD DEL SONIDO EN EL GAS (pies/seg) 1277.99
INTENSIDAD DE CALOR SOLAR (BTU/hr-pie2) 350
"RESULTADOS"

FLUJO MSICO DE GAS ( Lb/hr) 102579


RELACIN SONICA 4.7758
DAMETRO DEL TIP(pulg) 16.5
LONGITUD DE LA LLAMA(pies) 149.79
VELOCIDAD DEL GAS EN EL TIP (pies/seg) 383
VELOC DEL GAS DE ACUERDO AL DIMETRO Y FLUJO MSICO EN EL TIP (pies/seg) 379.51
RELACIN VELOCIDAD DEL VIENTO/VELOCIDAD DEL GAS EN EL TIP 0.053
DESPLAZAMIENTO HORIZONTAL/LONG DE LA LLAMA 0.662
DESPLAZAMIENTO VERTICAL/LONG DE LA LLAMA. 0.589
DESPLAZAMIENTO HORIZONTAL DE LA LLAMA(pies) 79.34
DESPLAZAMIENTO VERTICAL DE LA LLAMA (pies) 88.22
CALOR TOTAL LIBERADO POR LA COMBUSTIN (BTU/hr) 2154167001.5
CAIDA DE PRESION TOTAL EN EL MECHURRIO (psi) 1.179
DISTANCIA HORIZONTAL SUPUESTA ENTRE EL MECHURRIO Y UN PUNTO DE EXPO-
SICIN (pies) 0
FRACCIN DE CALOR RADIADO POR LA LLAMA 0.2188
INTEN DE CALOR RADIADA POR LA LLAMA EN LA BASE, MAX PERMISIBLE "K" (BTU/hr-pie2) 1200
ALTURA DE LA ESTACA (m) 20.34
ALTURA DEL

DIMENSIONES DE LA ESTACA
DAMETRO DE LA ESTACA(pulg) 17.0
ALTURA DE LA ESTACA (m) 38
CAPACIDAD (MMPCND) 46.00

TIEMPO DE EXPOSICIN PARA LA INTENSI DE CALOR SUPUESTA {440 BTU/h-pie2} (min) INFINITO
NMERO DE ESTACAS 1.0
DISTANCIA DE LA ESTACA DE PROCESO Y TERCEROS (m) 78
SENSIBILIDAD DE LA ALTURA DEL MECHURRIO CON RESPECTO A "K" EN LA BASE

INTENSIDAD DE CALOR RADIA- DISTANCIA A PARTIR DEL CENTRO DE LA LLAMA ALTURA DEL ME-
DA POR LA LLAMA(BTU/h-pie2) (pies) CHURRIO (m)
1000 175 31
800 195 38
1300 153 25
1400 148 23
1500 143 22
1600 138 20
1700 134 19
1800 130 18
1900 127 17
2000 123 16
2100 121 15
2200 118 14
2300 115 13
2400 113 12
2500 110 12
INTENSIDAD DE CALOR RADIADA EN FUNCIN DE LA DISTANCIA HORIZONTAL

ALTURA DEL DISTANCIA DISTANCIA DESDE EL PORCENTAJE DE HUMEDAD FRACCIN DE "K" TRASMITIDA INTENSIDAD CALOR RADIADA
FLARE(m) HORIZ (m) CENTRO LLAMA (m) RELATIVA DEL AIRE % A LA ATMSFERA (POR LA LLAMA+LA SOLAR)
(BTU/h-pie2)
20 5 29 80 0.8031 1485
20 10 29 80 0.8031 1487
20 20 32 80 0.7991 1307
20 30 37 80 0.7912 1025
20 40 45 80 0.7823 798
20 50 53 80 0.7738 647
20 66 68 80 0.7619 508
20 76 78 80 0.7555 458
20 81 82 80 0.7528 440
20 91 92 80 0.7474 411
20 101 103 80 0.7425 389
20 111 113 80 0.7381 373
20 121 123 80 0.7341 361
20 131 134 80 0.7304 352
20 141 144 80 0.7269 344
20 151 155 80 0.7238 338
20 161 165 80 0.7208 333
20 171 176 80 0.7180 329
20 181 186 80 0.7154 326
20 191 197 80 0.7129 323
20 201 207 80 0.7106 321
20 211 218 80 0.7084 319
20 221 229 80 0.7063 317
20 231 239 80 0.7043 316
20 241 250 80 0.7024 314
20 251 261 80 0.7006 313
20 261 271 80 0.6988 312
20 271 282 80 0.6971 311
20 281 292 80 0.6955 310
20 291 303 80 0.6940 310
20 301 314 80 0.6925 309
20 311 324 80 0.6910 308

DISTANCIA HORIZONTAL SEGURA


INTENSIDAD DE CALOR RADIADA EN FUNCIN DE LA DISTANCIA HORIZONTAL

ALTURA DEL DISTANCIA DISTANCIA DESDE EL PORCENTAJE DE HUMEDAD FRACCIN DE "K" TRASMITIDA INTENSIDAD CALOR RADIADA
FLARE(m) HORIZ (m) CENTRO LLAMA (m) RELATIVA DEL AIRE % A LA ATMSFERA (POR LA LLAMA+LA SOLAR)
(BTU/h-pie2)
15 5 24 80 0.8133 1500
15 10 23 80 0.8152 1593
15 20 27 80 0.8071 1232
15 30 34 80 0.7956 880
15 40 43 80 0.7845 665
15 50 52 80 0.7748 542
15 66 68 80 0.7621 440
15 76 78 80 0.7554 405
15 86 88 80 0.7496 381
15 96 99 80 0.7444 365
15 106 109 80 0.7398 353
15 116 120 80 0.7355 343
15 126 130 80 0.7316 337
15 136 141 80 0.7281 331
15 146 151 80 0.7248 327
15 156 162 80 0.7217 323
15 166 172 80 0.7189 320
15 176 183 80 0.7162 318
15 186 194 80 0.7137 316
15 196 204 80 0.7113 314
15 206 215 80 0.7090 313
15 216 225 80 0.7069 312
15 226 236 80 0.7049 311
15 236 247 80 0.7029 310
15 246 257 80 0.7011 309
15 256 268 80 0.6993 308
15 266 279 80 0.6976 308
15 276 289 80 0.6960 307
15 286 300 80 0.6944 307
15 296 311 80 0.6929 306
15 306 321 80 0.6914 306
15 316 332 80 0.6900 305

DISTANCIA HORIZONTAL SEGURA


ESTUDIOS ESPECIALES DE INGENIERA E IMPACTO AMBIENTAL VARGAS (ESEIMA)

HOJA DE CLCULO PARA EL DIMENSIONAMIENTO DE FLARE

PROYECTO:
O.D.I:
TAG:
CONTINGENCIA:

"DATOS"
CAUDAL DE GAS (MMPCED) 27.00
PESO MOLECULAR DEL GAS 19.4
TEMPERATURA DEL GAS EN EL MECHURRIO (R) 540
RELACIN DE CALORES ESPECFICOS( K=Cp/Cv) 1.304
PRESIN DEL GAS EN EL TIP(psia) 14.696
DENSIDAD DEL GAS @ T y P (lb/pie3) 0.0493
FACTOR DE COMPRESIBILIDAD DEL GAS @ T y P 0.9986
NMERO DE MACH EN EL TIP 0.3075
CALOR DE COMBUSTIN DEL GAS (BTU/Lb) 18370
VELOCIDAD DEL VIENTO (pies/seg) 30
VELOCIDAD DEL SONIDO EN EL GAS (pies/seg) 1343.51
INTENSIDAD DE CALOR SOLAR (BTU/hr-pie2) 300
"RESULTADOS"

FLUJO MSICO DE GAS ( Lb/hr) 57511


RELACIN SONICA 4.6169
DAMETRO DEL TIP(pulg) 12.00
LONGITUD DE LA LLAMA(pies) 106.86
VELOCIDAD DEL GAS EN EL TIP (pies/seg) 413
VELOC DEL GAS DE ACUERDO AL DIMETRO Y FLUJO MSICO EN EL TIP (pies/seg) 412.8
RELACIN VELOCIDAD DEL VIENTO/VELOCIDAD DEL GAS EN EL TIP 0.073
DESPLAZAMIENTO HORIZONTAL/LONG DE LA LLAMA 0.333
DESPLAZAMIENTO VERTICAL/LONG DE LA LLAMA. 0.475
DESPLAZAMIENTO HORIZONTAL DE LA LLAMA(pies) 35.54
DESPLAZAMIENTO VERTICAL DE LA LLAMA (pies) 50.72
CALOR TOTAL LIBERADO POR LA COMBUSTIN (BTU/hr) 1056484252.4
CAIDA DE PRESION TOTAL EN EL MECHURRIO (psi) 1.359
CAUDAL DE GAS DE PURGA DEL FLARE (MPCED) 1.62
FRACCIN DE CALOR RADIADO POR LA LLAMA 0.2773
INTEN DE CALOR RADIADA POR LA LLAMA EN LA BASE, MAX PERMISIBLE "K" (BTU/hr-pie2) 1200
INTEN DE CALOR RADIADA POR LA LLAMA MAX PERMISIBLE PARA PROCESOS Y TERCEROS "K" (BTU/hr-pie2) 440
DISTANCIA DESDE EL CENTRO DE LA LLAMA A TERCEROS Y PROCESOS "D" (pie) 230

DIMENSIONES DE LA ESTACA
DAMETRO DE LA ESTACA (pulg) 12.0
ALTURA DE LA ESTACA (m) 35
CAPACIDAD (MMPCED) 27.00
TIEMPO DE EXPOSICIN PARA LA INTENSI DE CALOR SUPUESTA {440 BTU/h-pie2} (min) INFINITO
NMERO DE ESTACAS 1.0
DISTANCIA DESDE LA ESTACA HASTA PROCESO Y/O TERCEROS (m) #N/A
440.00
INTENSIDAD DE CALOR RADIADA EN FUNCIN DE LA DISTANCIA HORIZONTAL

ALTURA DEL DISTANCIA DISTANCIA DESDE EL PORCENTAJE DE HUMEDAD FRACCIN DE "K" TRASMITIDA INTENSIDAD CALOR RADIADA
FLARE(m) HORIZ (m) CENTRO LLAMA (m) RELATIVA DEL AIRE % A LA ATMSFERA (POR LA LLAMA+LA SOLAR)
(BTU/h-pie2)
19 5 38 80 0.7904 1495
19 10 30 80 0.8013 2179
19 20 32 80 0.7987 1991
19 30 37 80 0.7918 1568
19 40 44 80 0.7833 1188
19 50 52 80 0.7749 922
19 60 61 80 0.7672 747
19 70 70 80 0.7603 632
19 80 80 80 0.7541 554
19 90 90 80 0.7486 499
19 100 100 80 0.7436 460
19 110 111 80 0.7391 431
19 120 121 80 0.7350 409
19 130 131 80 0.7312 392
19 140 142 80 0.7277 378
19 150 152 80 0.7245 368
19 160 163 80 0.7215 359
19 170 173 80 0.7187 352
19 180 184 80 0.7160 346
19 190 194 80 0.7135 341
19 200 205 80 0.7112 337
19 210 215 80 0.7089 333
19 220 226 80 0.7068 330
19 230 237 80 0.7048 327
19 240 247 80 0.7028 325
19 250 258 80 0.7010 323
19 260 269 80 0.6992 321
19 270 279 80 0.6975 319
19 280 290 80 0.6959 318
19 290 300 80 0.6943 317
19 300 311 80 0.6928 315
19 310 322 80 0.6914 314

DISTANCIA HORIZONTAL SEGURA