Oil/Air

COMPLETE OIL / AIR Cooler Units


COOLER SYSTEM WITH
AXIAL FAN FOR INDUSTRIAL
Motoinverter Series
APPLICATIONS. EL MI Type
General description
In hydraulic systems energy is
transformed and transmitted. During
this process, efficiency losses occur,
i.e. mechanical and hydraulic energy
is converted into heat. It is the purpose
of the cooler to dissipate this heat and
to maintain the thermal balance of the
hydraulic fluid.

Application
These high performance coolers
equipped with axial fans and
motoinverter are suitable for hydraulic
cooling applications, with both return
line and off line versions available.
Typical applications include: industrial
power units, lubrication systems (i.e.
gearboxes) and machine tools.

OK-EL MI Product Features


zzControlled Cooling Power
zzConstant Output Oil Temperature
zz16 Bar Dynamic Pressure Rating
OK-EL MI coolers use high efficiency
axial fans driven by motoinverter and
sturdy aluminium bar-and-plate cooling
elements. This guarantees immediate
adjustment to required cooling
performance under changing load
conditions and superior cooler durability.
Cooling power, as a function of fan
speed, is controlled depending on the
required oil outlet temperature.
The main advantage of this cooler/
motoinverter product line is the
integration of oil temperature control
via proportional fan speed into one very
compact design. Further advantages
are a lower noise level and lower power
consumption over the term of a year.
E 5.810.0/12.08
MAIN FEATURES AND CHARACTERISTICS
FEATURES AND DESCRIPTION CUSTOMER BENEFITS
ADVANTAGES
The motoinverter cooler needs only one power
Reduced engineering and installation costs
supply to run
Compact assembled configuration with
No additional cost for components and their
integrated temperature thermistor in the
installation like: temperature thermistor, signal
cooling element and directly connected to the
Plug and Play converter, control devices, wiring and terminals
inverter
Embedded motor speed control Reduced engineering for motor speed control
One motor type able to cover values up to No additional engineering if heat to dissipate
1800 RPM increases (within max performances of the
Flexibility whenever a higher RPM is needed motoinverter cooler)
Published performance data @ nominal RPM
Low operational cost related to a cooler in the same size without No need for a second or a larger cooler
motoinverter, allows an increase by 20%
Noise level depending on the fan speed,
Lower average noise level Lower noise level for the most time of the year
corresponding to the required cooling power
The inverter controls the fan speed in order Constant oil temperature at different ambient
to have the oil temperature as constant as temperature allows an optimal cooling
possible performance
Variable fan speed
Energy absorption by the cooling system
Power consumption costs are related to real
during the year is highly influenced from the
need cooling power
season
The electrical motor is not directly connected
The inverter allows a controlled and stable
Motor power supply to the main power supply which can be
power supply for the motor (PWM)
disturbed and not regulated
NTC temperature sensor One component for temperature measuring Fast to replace
To simplify service and maintenance work,
NTC temperature sensor are fixed in cartridge
Cartridge holder Easy maintenance
holders; which allows a replacement without
the need to empty the cooling circuit.
Customised and adapted to the cooling system
The inverter parameters are set according to
Inverter parameters The inverter parameters can be changed on
the customer cooling system
site
Less stress for oil and cooling system due to Oil temperature regulation due to the
Oil/coling system
less temperature fluctuations integrated system
E 5.810.0/12.08

2
COOLER MAIN COMPONETS
OK-EL10MI OK-EL12MI -EL14MI

Complete Oil/Air cooler unit consist of (1) metal housing,


(2) motoinverter, (3) axial fan and (4) heat exchanger.
The oil connections are external.

OK-EL8MI -EL10MI

OK-EL12MI -EL14MI

E 5.810.0/12.08

3
COOLING CAPACITY TECHNICAL DETAILS
Depending on oil flow and the TABLE OF TECHNICAL SPECIFICATIONS, SIZE 8 to 14
temperature differential delta-T between

Oil flow [l/min] at max. operating


Ambient temperature range [C]
oil inlet and air inlet temperature.

Motoinverter capacity [kW] @

Max. operating pressure [bar]


For cooling capacity with very low

Type of temperature sensor

Noise level [dB(A)] (at 1m

Max. oil temperature [C]

Max. motor speed [RPM]


delta-T (i.e. < 10C), please contact our

distance) @ 1000 RPM

Max. viscosity [mm2/s]


technical support staff.

N of poles[-]/size[-]

continuous working
for the fan motor
COOLER SELECTION

Type of cooler

Weight [kg]
Designation:

pressure
PV = Power loss [kW]

50Hz
P01 = Specific cooling capacity [kW/C]
V = Tank volume [l]
-20
oil = Oil density [kg/l] OK-EL8MI NTC *300 4/100 2.2 77 16 130 1720 2000 65
+40
for mineral oil 0.915 kg/l
Coil = Spec. heat capacity [kJ/kgC] -20
OK-EL10MI NTC *330 4/100 2.2 78 16 130 1430 2000 145
for mineral oil 1.88 kJ/kgC +40
T = Temperature increase *660
2x -20 4/100 2.2
in the system [C] OK-EL12MI (2 cooling 83 16 130 1430 2000 300
NTC +40 (2 motors) (2 mot.)
t = Operating time [min] elements)
T1 = Desire oil temperature [C] *660
2x -20 6/112 2.2
T3 = Ambient temperature [C] OK-EL14MI (2 cooling 88 16 130 1200 2000 360
NTC +40 (2 motors) (2 mot.)
elements)
Example 1: * :max oil flow
Measuring the power loss on existing 1. For direction of fan rotation, please refer to arrow on cooler housing.
units and machinery. 2. Electric fan drive: axial drive with forward flow through cooler element (sucking).
For this method the temperature 3. Cooling fluid: mineral oil to DIN 51524; for other fluids, please contact our sales/
increase of the oil is measured over technical department.
certain period of time. The power loss
can be calculated from the temperature 4. Three-phase motoinverter IP55, conforming to CE norm.
increase 5. Published noise levels can only be used as guidance, as acoustic properties
Parameters: vary and depend on the characteristics of room, connections, viscosity and
The oil temperature increases from resonance.
20C to 60C over 16 minutes. Warning!
The tank contains 400l. When operating a cooler in conditions where the difference in temperature between
Heat to dissipate: ambient air and inlet oil exceeds 50 Celsius [C], care must be taken to avoid
T Coil oil V
cycling of the fan at full speed/air flow. This can cause a rapid change in material
PV = [kW] temperature of the cooling element and may result in a significant reduction of the
t 60 cooler lifetime or direct damage to the cooling element through thermal stress.
40 1.88 0.915 400
PV = = 28.7 [kW] Please contact your HYDAC branch or distributor for speed control solutions.
16 60
Cooler selection:
NTC TEMPERATURE SENSOR
zzDesired oil temperature: 60C
In our case the NTC temperature sensor (called also thermal resistor or thermistor)
zzAmbient temperature (air): 30C
is an electronic component that exhibits a large change in resistance with a change
PV
P01 = [kW/C] in body temperature. Made of ceramic semiconductor and has a large negative
T1 T3 temperature coefficient of resistance (NTC devices).
28.7
P01 = = 0.96 [kW/C]
60 30
NTC MAIN TECHNICAL CHARACTERISTICS:
A 10% safety margin is recommended
Technical
to allow for element contamination and
characteristic
therefore the specific power is:
P01 1.1 = 1.06 [kW/C]
The power loss 1.06 kW/C must be
dissipated by an oil cooler. Working range (NTC) -20 +120C *)
Suggestion: Specific temperature
10k
At dT40C => PV = 42.4kW at 25C
zzCooler OK-EL8MI Measure accuracy 1%
P = 42.4kW at 120l/min and 1200RPM Protection degree IP67
zzCooler OK-EL10MI Temperature inertia 10K in liquid at 2m/s
P = 42.4kW at 60l/min and 750RPM Cartridge holder

Example 2:
The power loss can also be estimated.
With unrestricted flow approx. 15 to 20%
of the drive power.
E 5.810.0/12.08

With restricted flow up to 30% of the


drive power.

*) to achieve best accuracy

4
MOTOINVERTER MAIN DATA
Motor Type 3 phase single winding with 3 phase frequency inverter on board
Pole nr. 4 or 6
UIN nom 3x 400V 15%
fIN range 40 70 Hz
P nom 2.2 kW @ 50Hz
Protection degree (IP) 55
Isolation class F
Service type S1
Mounting IMB14 D160
Frame Iec 100 (4pole) / 112 (6pole)

MOTOINVERTER BLOC DIAGRAM

Tempsensor
Temp sensor
AC
RR L1
SS L2 M
TT L3
GND
GND
AC
inverter 3ph motor
INVERTER 3ph MOTOR

MOTOINVERTER FREQUENCY REGULATION

f [Hz] Description

f max P2 P1 Cooler switch ON point (Tmin, fmin )


P2 Cooler max speed (Tmax, fmax )
Coolling
P3 Cooler switch OFF point (Tmin-Hoff, fmin )
range

Hoff Param. to set Description


f min P1
P3 Tmin Oil temperature => cooler ON
Tmax Oil temperature @ motor max. speed
fmin Min motor frequency => cooler ON
Tmin Tmax fmax Max motor frequency
Tmin-Hoff Hoff Temperature offset between
T [C] cooler switch ON - OFF

NOTE
The inverter parameters are set according to the customer requirements before cooler dispatch.
For on site parameters modification HYDAC SA, Switzerland is at your disposal. E 5.810.0/12.08

5
PERFORMANCE DIAGRAMS
Cooling capacity depends on oil flow and the temperature differential T between the oil inlet and air inlet.
For calculation of cooling capacity with very low T values (i.e. < 10C), please contact our technical support staff for help.
Tolerance: +/- 8%
OK-EL8MI
70

250 l/min
60
180 l/min
120 l/min
50
Heat dissipation at dT=40C [kW]

90 l/min

40

30
30 l/min

20

10

0
400 600 800 1000 1200 1400 1600 1800
Noise level dB(A) 60.6 76.8 85.8 86.8
@1 meter Limit of OK-EL8S
Values measured at T=40 C, may vary at lower T values.

OK-EL10MI
120

300 l/min
100
180 l/min
150 l/min
Heat dissipation at dT=40C [kW]

80 120 l/min

60
60 l/min

40

20

0
400 600 800 1000 1200 1400 1600
Noise level dB(A) 63.9 70.8 78.4 88.8
E 5.810.0/12.08

@1 meter Limit of OK-EL10L


Values measured at T=40 C, may vary at lower T values.
Published noise levels can only be used as guidance, as acoustic properties vary and depend on the characteristics of room,
connections, viscosity and resonance.

6
OK-EL12MI
250

600 l/min
200
360 l/min
Heat dissipation at dT=40C [kW]

300 l/min

240 l/min
150

120 l/min
100

50

0
400 600 800 1000 1200 1400 1600
Noise level dB(A) 68.9 75.8 83.4 93.7
@1 meter Limit of OK-EL12S
Values measured at T=40 C, may vary at lower T values.

OK-EL14MI
240
600 l/min

220
360 l/min
200 300 l/min
Heat dissipation at dT=40C [kW]

180
240 l/min

160

140

120 120 l/min

100

80

60
400 7 00 1000 1300
Noise level dB(A) 63 73 88 98
E 5.810.0/12.08

@1 meter Limit of OK-EL14L


Values measured at T=40 C, may vary at lower T values.
Published noise levels can only be used as guidance, as acoustic properties vary and depend on the characteristics of room,
connections, viscosity and resonance.

7
Pressure Drop Curves
Differential pressure p measured at 30 mm/s using mineral oil

3.00

EL14MI
2.50
EL12MI
Pressure Drop @ 30 mm/s [bar]

2.00
EL8MI
EL10MI
1.50

1.00

0.50

0.00
0.00 100.00 200.00 300.00 400.00 500.00 600.00 700.00
Oil flow [l/min]
Correction factor K for other viscosities:
Viscosity (mm/s) 10 15 22 30 46 68 100 150
Factor K 0.35 0.5 0.75 1 1.4 1.9 2.5 3.5

MODEL TYPE
(also order example)
OK-EL 8MI / 3.1 / M / 1

Type of cooler
OK-EL = Oil/Air cooler

Size / motor max speed


8MI = 1800 min-1
10MI = 1500 min-1
12MI = 1500 min-1
14MI = 1200 min-1

Type code and modification number:


for current levels of each type of cooler, see table on the internet site

Fluids
M = Mineral oil to DIN 51524
Other fluids upon request

Paint
1 = RAL 5009 (Standard)
Other paint available upon request
E 5.810.0/12.08

Motor power supply


Standard voltages and frequencies for 3phase motor
Input voltage range 400VAC 15%
Input frequency range 50Hz -20% / +40%

8
DIMENSIONS
OK-EL8MI OK-EL12MI and 14MI

Plug

OK-EL10MI

Plug

A1 B C1 D1 D2 D3 E1 E2 E3 F S1 W1 * W2 * Z1 Z3
10 25 10 2 2 2 5 5 5 /Slot Min. Min.
OK-EL8MI 726 634 706 410 560 450 630 58 74 9x20 > 100 1200 600 G1 M22x1.5
OK-EL10MI 1030 767 930 750 700 790 910 75 116 12 > 100 2800 900 G1 M22x1.5
OK-EL12MI 2130 735 1000 750 760 800 910 1080 30x13 > 100 3000 1000 G1 M22x1.5
OK-EL14MI 2300 735 1150 750 900 800 910 1164 30x13 > 100 3000 1000 G1 M22x1.5
* : for smaller distances, please contact our technical office

CERTIFICATION FOLLOWING EN 1048 NOTE


HYDAC SA design and manufacture high quality coolers The information in this brochure relates to the operating
that are tested on certified test stands to give reliable and conditions and applications described.
repeatable high performance. To ensure the performance is For applications or operating conditions not described, please
accurate, testing in compliance with a recognized international contact the relevant technical department.
test standard is the best solution. For air/liquid coolers this is Subject to technical modifications.
EN1048.
HYDAC SA test procedure complies with
the requirements of EN 1048 and both
the procedure and test equipment are
independently inspected and certified by
TVSD.
The cooler performance details in this brochure
have been tested following EN 1048.
E 5.810.0/12.08

9
10
E 5.810.0/12.08

Notizen
Notizen

E 5.810.0/12.08

11