You are on page 1of 4

Nagarjuna Construction Company Limited

Engineering Design and Technology Department


CALCULATED CHECKED DATED PAGE
PROJECT Golden Jubilee Hotels Ltd
KNR KP

JOB NO.
Design of Shuttering for Beams

DRG NO.

6.5 KN 2 KN

5 6
B A
1
11 9

2 7
10
3

8
4

1 Loading on the Bracket

Spcing between brackets = 1.8 mts


construction load = 2 Kn/m2

Point load from the prop at the end of bracket ( A) = 1.62 KN


(1.8*0.9*2/2)
Say = 2 KN

Point load from the prop at the center of bracket ( B)


Due to live load = 2.628
H13+1.8*0.56/2*2
Due to slab projection
(slab average thickness 200mm)
( 0.2*25) = 2.52 KN

Total load at B 5.148 KN


say 6.5 KN

2 Reactions at bolt locations

Moment due to loads M= 6.56 KN

So axial force in the bolt F= 14.58 KN

Shear in the bolts V= 4.25 KN

3 Forces in the members ( From STAAD File)


Member Axial Force Moment Shear
1 0 T 0.838 KN-m 4 KN
2 0 T -0.838 KN-m 5 KN

3 0 T 0.465 KN-m 4 KN

4 8 T -0.042 KN-m 2 KN

5 3 T -0.065 KN-m 3 KN

6 3 T 0.052 KN-m 0 KN

7 4 T 0.002 KN-m 0 KN

8 16 C -0.011 KN-m 0 KN

9 7 C 0 KN-m 0 KN

10 9 T -0.026 KN-m 0 KN

11 1 T -0.062 KN-m 0 KN
Nagarjuna Construction Company Limited
Engineering Design and Technology Department
CALCULATED CHECKED DATED PAGE
PROJECT Golden Jubilee Hotels Ltd
KNR KP

JOB NO.
Design of Shuttering for Beams

DRG NO.

1 Design of bolts

Dia o f bolts 16 mm

Area of the bolt A = 201 mm2

Axial load on the bolt P = 14.58 KN

Shear force in the bolt V = 4.25 KN

Axial stess in the bolt P/A = 73 Mpa

Permissible axial stress as per IS 800 = 100 Mpa


Hence O.K

Shear stress in the bolt V/ A = 21 Mpa


Permissible axial stress as per IS 800 100 Mpa
Hence O.K

Combined stress due to shear and tension = 0.94

Hence O.K

2 Design of back to back angles

Compression capacity of back to back angle

Area of the member A 856 mm2

Max length of the member L 0.56 m

Radius of gyratio r 13.6 mm

Slender nes ratio of the member L/r 41.18

Permissible stress ( IS 800) 139 Mpa

Capacity of the section 119 KN

force experinced by member is 7 KN


<119 KN
Hence safe

Bending capacity of the member

Max. cantilver length of the angle member 0.45 m


Slender ness ratio 33

Section modulus of the member 5000 mm3

Depth of the section D 45 mm

Flange thickness T 5 mm

Permissible stress ( IS 800) 200 N/mm2


( Increasing 25% for Temporary loads)
Stress induced in the member due to load 167.6 N/mm2

Shear capacity of the member

Permissble average shear force 100 N/mm2

Shear capacity of the section 85.6 KN

Shear experienced by the member 5 KN


<85.6 KN
Hence safe

Compression capacity of pipe members

Area of the member A 258 mm2

Max length of the member L 1.06 m

Radius of gyratio r 11 mm

Slenderness ratio of the member L/r 96

Permissible stress ( IS 800) 90

Capacity of the section 23.22 KN

force experinced by member is 16KN


<23.22 KN
Hence safe

Hence the bracket System can carry the loads From Props safely

You might also like