Professional Documents
Culture Documents
System Description
CONTENTS:
2 INTRODUCTION 6
3 BASIC SPECIFICATIONS 6
4 SYSTEM CONFIGURATION 6
5 TECHNICAL DESCRIPTION 7
5.1 Design 7
Y6603A11.DOC 1
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
6 FUNCTION DESCRIPTION 12
6.1 RMM 12
6.2 APOID 12
7 OPERATING INSTRUCTIONS 12
8 MAINTENANCE 14
9 APPENDICES 15
Y6603A11.DOC 2
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
Y6603A11.DOC 3
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
do not forget that "safeties" are only provided at ordinary access points, and that
dangerous circuits may be exposed by dismounting elsewhere;
in some cases, dangerous voltages may remain after an equipment is shut down, due to
charges remaining in capacitors that should be always discharged before working on the
equipment;
it is forbidden to go alone into a compartment to inspect or repair dangerous equipment.
1.6.1 1st operation: Separate the victim from the electric circuit
Use a dry, non-conductive material, such as rubber gloves or cloth to pull away either the wire
or the victim. Do not use moist or metallic objects. If voltage exceeds 1000 V, cut the power
and prepare to catch the victim, if he is "suspended" (caught on) the live component.
If power cannot be cut, stand on an insulated stool and use a dry, non-conducting pole to
separate the wire from the victim without allowing it to touch his face or bare skin.
When the victim has been separated from the electric circuit:
do not try to remove him away. Treatment should begin at once, on the spot;
lay the victim on his back, on the ground;
loosen his clothing, collar, necktie, etc.;
use your fingers to remove any tobacco-quid, false teeth, etc. from his mouth.
Y6603A11.DOC 4
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
Y6603A11.DOC 5
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
2 Introduction
APP site of MSSR-1/RL-2000 enables radar situation displaying on monitors with high
resolution, monitoring of APP units and event. complete monitoring and remote controlling of
connected radar. Further essential function shall be data receiving, too, from further radar
sites, and their conversion together with data conversion of locally corresponding radar for
multiradar processing in EUROCAT 2000 system.
Block diagram of APP part is shown in the Appendix 1.
3 Basic Specifications
4 System Configuration
Y6603A11.DOC 6
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
The mentioned electronic units are layout on APP part in electronic rack (RMM, APOID) and
monitors, keyboards, mouses are placed on technical table.
5 Technical Description
5.1 Design
Cabinets and consoles
Electronic unit console is a 19 industrial cabinet with structural module height of 40U
(approximately 2 m). The cabinet comprises heavy-current distribution, vent units with filter,
and mechanical components for particular installation of units and cabling (guides, cable
holders, ...).
In the bottom cabinet part, a vent unit with 3 fans is situated, under which a pullout filter for
the air cleaning is located. Sucked cooler air from the cabinet bottom is directed to its front
part in front of glazed and sealed door, from where it passes to particular electronic units.
Heated air, forced by 3 upper switch on/off fans, is then lead through the cabinet rear side
upwards via upper cover. Above the bottom vent unit, a heavy-current switchboard is situated
comprising a filter and essential control elements and indicators of the heavy-current
distribution. They involve: mains circuit breaker, main switch with glow lamp indicator of the
mains voltage presence, and fans fuse.
The cabinet, see Appendix 2, and for its electric diagram, see Appendix 3.
Industrial console lenght of 2 m (technical table) is designed with two 19 legs with modular
height of 12U, which enables assembly up to 3 sliding drawer.
Y6603A11.DOC 7
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
Internal housing consists in classical modular layout with PC and electronic unit cards
inserted to the passive back panel. Particular cards are designed with maximal application of
VLSI and XILINX circuits assembled on classical multilayer cards, or on cards combining
classical and surface mount technology.
Mains supply 230 V through a multilevel switch mode supply of ATX type with the input
supply switch on the power supply rear panel. If this switch in the on position I, the power
supply input section is under permanent mains voltage, even at the electronic unit turning out
by means of the front switch. In the off position O, the power supply is permanently
disconnected from the input mains voltage.
Notice: Electronic unit can be turned on by means of the front button only in position I
on.
Autonomous cooling with forced air circulation is applied. The air is sucked by a fan via filter
in the front panel, and exhausted through holes in the rear panel and power supply fan, and
through the power supply unit. Since the suction fan is more powerful, slight overpressure is
maintained within the chassis.
Applied design enables installation of the equipment to standard 19 cabinets.
Y6603A11.DOC 8
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
Utilized resolution of the computer part enables extending the equipment in accordance with
the customer requirements, for example, as regards cards increasing number of LAN
connections, connectable serial lines, etc.
Y6603A11.DOC 9
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
Y6603A11.DOC 10
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
5.6.2 Grounding
Before connection of power supply network voltage, there is necessary to create grounding
connection to grounding system of customer from grounding clip of distribution board 104
(cable W21).
Required ground resistance for ensuring:
a) Protection against dangerous contact potentials R<200 Ohm.
b) Protection against lightning and protection against overvoltage, created by atmospheric
disturbances R<5 Ohm.
Y6603A11.DOC 11
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
6 Function Description
System of control, radar display and data converting at the APP part of MSSR-1/RL-2000 is
designed for complete control and monitoring of connected radar, radar data and additional
information processing, their displaying at technical workplace and for transmission all
required data to EUROCAT 2000.
Description of particular system parts is as follows:
6.1 RMM
RMM, i.e. Radar maintenance monitor, enables maintenance display of selected radar data.
Maintenance display module is intended for displaying of radar plots for the technical
operating personnel purposes only. Displayed data are plots from MASTER radar channel
in ASTERIX format cat 034 and 048. The second displayed data channel are data from co-
hearing of serial synchronous line, which are output radar data (cat. 034 and 048 or cat. 02
and 01) transmitted into connected system (EUROCAT 2000). Data, displayed in that channel,
are identical with data, which are really transmitted into RS232 line.
6.2 APOID
APOID unit shall be used for radar data transmission into EUROCAT 2000 system. The used
protocol shall be used HDLC-UI (i.e. one-way data transmission). Standard output of radar
plots shall be in ASTERIX format cat. 048 a 034 in selected LAN port. APOID receives data
from above mentioned port and transmit them into RS232 interface. Output data format shall
be possible to be configured in APOID. It shall be possible to select output data format both
ASTERIX cat. 034 and 048 and ASTERIX cat. 02 and 01.
APOID shall be equipped with diagnostics channel for input/output interface and with
diagnostics on level of ASTERIX messages (plots and service messages).
7 Operating Instructions
Y6603A11.DOC 12
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
button, HDD activity indicator, control and indication of DVD, event. CD-ROM drive
including aperture for media. All these elements are by default situated behind lockable door.
Basic control elements and indicators (front panel see Appendix 5).
- I / O button turning the block supply on/out
- RESET button after the button pressing, HW restart of the
equipment occurs, i.e. entire unit initiation
(HW and SW)
- button of DVD (CD-ROM) drive shifting after the button pressing, DVD (CD) disk
out/in holder of the DVD CD-ROM) drive shall shift
out/in
- unit supply indication green LED indicates supply voltage after
switch on
- HDD indication yellow LED indicates activity of the hard disk
drive - HDD
- DVD (CD-ROM) drive indication see Description of the removable medium unit
control
Y6603A11.DOC 13
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
8 Maintenance
Y6603A11.DOC 14
ELDIS APP site of MSSR-1/RL-2000 Y6603A
System Description
cleaned (or removed) which is accessible after the front panel part removal. Higher dust
quantity could cause the device decreased reliability and deteriorated cooling.
9 Appendices
Appendix 1: Block diagram of the APP part of MSSR-1/RL-2000.
Appendix 2: Block layout in 19/40U cabinet.
Appendix 3: Electric diagram of ELDIS cabinet.
Appendix 4: Technical description of APOID unit.
Appendix 5: Front and rear panels of the RMM unit.
Appendix 6: Wiring diagram of LAN switch and APOID power supply.
Appendix 7: Cabling block diagram of the APP part of MSSR-1/RL-2000.
Appendix 8: Description of the removable medium unit control.
Y6603A11.DOC 15