Professional Documents
Culture Documents
_____________________________________________________________________
UNIVERSIDAD DELOS ANDES
FACULTAD DEINGENIERÍA
DEPARTAMENTO DE INGENIERÍA CIVIL Y AMBIENTAL
ASESORES:
MANUEL RODRÍGUEZ SUSA
IVÁN CASTILLO
_____________________________________________________________________
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
TABLA DE CO NTENIDO
1. INTRODUCCI ÓN ....................................................................................................1
1.1 Gener alidades......................................................................................................1
1.2 Antecedentes .......................................................................................................1
1.3 Motivación y Definición del Pro blema...............................................................2
1.4 Objetivo s .............................................................................................................2
1.4.1 Objetivo Específico ......................................................................................2
1.4.2 Objetivo s Generales .....................................................................................3
1.5 Resumen de Contenido .......................................................................................3
1.6 Resultado s Principales ........................................................................................3
2. PLANTA DE T RATAMIENTO EL SALITRE .......................................................5
2.1 Caracterización Afluente PTAR El Salitre .........................................................5
2.2 Remociones y Eficiencias de la PTAR El Salitre............................................. 16
2.3 Calidad del Efluente de la PTAR El Salitre...................................................... 21
3. METODOLOGÍ A................................................................................................... 28
3.1 Planta Piloto TPQA........................................................................................... 28
3.1.1 Com ponentes Físico s ................................................................................. 28
3.1.2 Car acterísticas de Diseño y Operación ...................................................... 32
3.2 Crono gramas de Operación y M uestreos.......................................................... 34
4. RESULTADOS Y ANÁLI SIS................................................................................ 37
4.1 Caracterización Planta Piloto TPQA................................................................. 37
4.2 Análisis Estadístico de Par ámetros ................................................................... 41
5. DESARROLLO DEL MODELO DE DOSI FI CACIÓN........................................ 48
5.1 Selección de la Arquitectura del Mo delo .......................................................... 48
5.2 Defin ición del Modelo de Dosif icación ............................................................ 48
5.3 Calibración del Modelo de Do sificación .......................................................... 51
5.4 Validación del Modelo de Dosificación ............................................................ 54
6. CONCLUSI ONES Y RECOMENDACIONES...................................................... 56
6.1 Conclusiones ..................................................................................................... 56
6.2 Recomendacion es.............................................................................................. 56
7. BI BLIOGRAFÍ A .................................................................................................... 57
_____________________________________________________________________
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
ÍNDIC E DE FIGURAS
_____________________________________________________________________
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
_____________________________________________________________________
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
ÍNDIC E DE TABLAS
Tabla 1.1 Características del agua residual afluente de la PTAR El Salitre. ................4
Tabla 1.2 Características del agua residual de la Planta Piloto. ...................................4
Tabla 3.1 Caudales Escalado s Planta Piloto TPQA. .................................................. 33
Tabla 3.2 Ubicación de Válv ulas en Tan ques de Flo culación. ................................... 33
Tabla 3.3 Mediciones realizadas en las Campañas de Monitoreo. ............................. 34
Tabla 3.4 Cam paña de Monitoreo 1. .......................................................................... 35
Tabla 3.5 Cam paña de Monitoreo 2. .......................................................................... 35
Tabla 3.6 Cam paña de Monitoreo 3. .......................................................................... 36
Tabla 4.1 Características del agua residual afluente de la planta piloto. .................... 37
Tabla 4.2 Características del agua residual efluente de la planta piloto. .................... 41
_____________________________________________________________________
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
1.1 Generalidades
En la antigüedad las aguas residuales producto de la actividad hum ana eran vertidas
sobre los cauces naturales sin previo tratam iento. Inicialmente, este hecho no se
traducía en un deterioro palpable de la calidad del agua, debido a que el caudal y las
características de las aguas residuales eran de una m agnitud tal, que la sola capacidad
de auto-depuración del cuerpo de agua permitía degradar la carga de m ateria orgánica
presente. Sin embargo, el crecim iento desm edido de la población y la incursión del
hom bre en nuevas actividades industriales ha ocasionado que las aguas residuales se
tornen m uy difíciles de tratar de manera natural en los cuerpos de agua.
Lo anterior ha logrado que la hum anidad propenda por retornar las aguas servidas a su
ciclo natural con unas características de calidad tales, que perm itan su posterior re-
uso. Las plantas de tratamiento de aguas residuales aparecen entonces com o una
solución a esta problem ática, logrando m ediante diferentes procesos la rem oción de la
carga orgánica, los nutrientes y demás agentes contaminantes asociados con las
características inherentes a las diferentes actividades industriales y dom ésticas.
El Tratamiento Primario Quím icamente Asistido (TPQA) hace parte de los m étodos
de tratamiento avanzado que en la actualidad se encuentran en auge, gracias a las
ventajas que proveen. Este tipo de tratam iento ha demostrado ser altamente efectivo
cuando se encuentra una amplia variación estacional en el caudal de aguas residuales;
en espacios limitados para construir una planta de tratamiento; cuando las
características del cuerpo receptor definen la necesidad de un grado de tratamiento
mayor que el prim ario pero menor que el secundario; o en las instancias en que se
busca optim izar la desinfección del agua residual sin necesariam ente buscar lo mismo
en cuanto a una remoción de materia orgánica (como podría ser el caso para descargas
subm arinas o sistem as de re-uso para riego agrícola).
1.2 Antecedentes
La PTAR El Salitre fue concebida como una planta de tratam iento por fases, en la
cual la prim era fase contempló un tratamiento primario por m edio de rejillas de
__________________________________________________________________ 1
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
desbaste, una rem oción de grasas por medio de aireación y una posterior
sedim entación prim aria; la segunda fase de la planta estim aba la construcción de un
sistema de lodos activados acompañado de una sedimentación secundaria cuyo
efluente sería descargado al río Bogotá.
Actualm ente la PTAR El Salitre cuenta con la infraestructura de la primera fase, con
una capacidad para tratar 4 m 3/s en prom edio. Con el fin de cumplir con los criterios
de eficiencia im puestos por la legislación colombiana (40% de rem oción en la DBO5
y 60% de la rem oción en los SST) la Em presa de Acueducto y Alcantarillado de
Bogotá (EAAB) se ha visto en la necesidad de asistir quím icamente el tratamiento
prim ario (Departam ento de Operaciones PTAR El Salitre).
1.4 O bjetivos
__________________________________________________________________ 2
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
__________________________________________________________________ 3
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
SST DBO5
Remoción 62% 40%
Se determinó que las variables medidas: el pH, el caudal, el nivel del canal, el
potencial rédox, la DQO, la DBO5, la tem peratura y la conductividad, no
inciden en la eficiencia de una planta piloto TPQA bajo las condiciones de
operación determinadas en la investigación.
__________________________________________________________________ 4
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
La PTAR El Salitre entró en funcionamiento en agosto de 2000 y a partir del prim ero
de m ayo de 2001 se tuvieron registros de la calidad del agua residual afluente y
efluente de la planta de tratam iento. A partir de julio de 2004 la planta de tratamiento
pasó a manos de la EAAB. Durante este periodo y hasta la fecha la EAAB ha sido
responsable del funcionamiento y adecuada eficiencia de la planta de tratam iento ante
las entidades públicas reguladoras de Colom bia (Ministerio del Medio Am biente,
Vivienda y Desarrollo Territorial y el DAMA).
Entre las m ediciones de calidad para la línea de aguas que realiza el laboratorio de la
planta de tratamiento se encuentra el pH, la alcalinidad, la turbiedad, SST, SSV y la
DBO5. Estos registros corresponden a dos muestras compuestas diarias tomadas por
un equipo automático de muestreo en las horas de 0:00 a.m. a 12:00 a.m . (muestra
a.m.) y 12:00 a.m . a 12:00 p.m. (m uestra p.m .). A continuación se presentan estas
medidas de calidad a partir de m ayo de 2001 hasta diciembre de 2005.
9.0
8.5
8.0
MUESTRA A.M
MUESTRA P.M
pH
7.5
7.0
6.5
6.0
28 01
0/ 2
2
1/ 4
4
5
9/ 05
/1 0 5
05
11 00
2/ 00
5/ 00
00
3/ 00
6/ 00
10 200
1/ 00
00
4/ 00
2/ 00
5/ 00
0
11 00
20
12 / 20
0
12 / 20
20
/2
/2
/2
/2
2
/2
/2
/2
/2
2
/2
/2
/2
4/
/
/
19
/5
13
24
20
28
/6
23
14
/9
17
28
5
/1
9/
8/
4/
7/
FECHA
Figura 2.1 pH Afluente PTAR El Salitre.
__________________________________________________________________ 5
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
800
700
Alcalinidad (mg-CaCO3 /l)
600
500
MUESTRA A.M
400 MUESTRA P.M
300
200
100
0
28 1
/5 1
13 1
24 2
9/ 02
/1 02
20 2
28 3
/6 3
8/ 04
/9 4
17 4
14 3
23 4
28 5
9/ 05
/1 05
5
7/ 00
11 00
2/ 200
5/ 00
3/ 00
6/ 00
10 00
0
1/ 00
2/ 00
4/ 00
5/ 00
00
0
12 20
0
20
0
12 20
/2
/2
/2
/2
2
/2
/2
/2
/2
/2
/2
/2
/2
2
0/
4/
/
1/
1/
5/
19
11
4/
FE CHA
600
500
Turbiedad (NTU)
400
MUESTRA A.M
200
100
0
28 1
/5 1
13 1
24 2
9/ 02
/10 02
20 2
28 3
/6 3
14 3
23 4
8/ 04
/9 4
17 04
28 5
9/ 05
/1 05
05
7/ 00
11 00
2/ 00
5/ 00
3/ 00
6/ 00
10 00
1/ 00
4/ 00
5/ 00
0
0
20
0
12 20
20
2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
4/
9/
1/
1/
5/
1
11
4/
2/
12
FECHA
Figura 2.3 Turbiedad Afluente PTAR El Salitre.
La turbiedad del afluente de la PTAR El Salitre presenta una m edia aritmética de 203
NTU teniendo registros m áxim os y m ínimos de 488 y 55 NTU respectivamente. En
el período 2001-2003 se puede apreciar com o la turbiedad aparentemente
incrementaba su valor en el canal de conducción, pero a partir de esa fecha hasta
finales del 2005 ésta se disminuyó y se m antuvo. Con el fin de profundizar un poco
__________________________________________________________________ 6
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
45
40
35
FRECUENCIA (%)
30
MUESTRA A.M
25 MUESTRA P.M
20
15
10
0
0
50
es
10
15
20
25
30
35
40
45
50
or
ay
M
TURBI EDAD (NTU)
Com o ilustra la Figura 2.4 se puede observar que para el 40% de las Muestras A.M
la turbiedad del afluente es de 200 NTU, mientras que este valor máxim o que presenta
la campana de Gauss para las Muestras P.M se desplaza, teniendo para una frecuencia
del 36.8% una turbiedad aproximada de 250 NTU. Este comportam iento se debe a la
particularidad en la operación de toma de agua mediante la estación de bom beo.
__________________________________________________________________ 7
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
En la Figura 2.5 se presenta un día típico del funcionam iento de la PTAR El Salitre,
en donde se puede observar que en las horas de la m adrugada se realiza un arrastre en
el caudal (línea negra), y posteriormente se dism inuye la toma de agua con el fin de
seguir el com portam iento del nivel del canal durante el resto del día.
700
600
500
SST (mg/l)
200
100
0
28 1
/ 5 01
3/ 1
24 2
9/ 02
0/ 2
28 3
/6 3
14 3
23 4
8/ 04
/9 4
17 4
2 8 05
9/ 0 05
4/ 5
20 2
05
7 / 20 0
2/ 00
5 / 20 0
/1 00
3/ 00
6 / 20 0
10 00
1 / 20 0
4 / 20 0
1 1 00
2 / 20 0
/1 0
12 2 0
1 1 20
5 / 20
20
/2
/2
12 /2
2
/2
/2
/2
9/
/
/
1/
5/
1
1
1
4/
FECHA
1
Departamento de Operaciones PTAR El Salitre.
__________________________________________________________________ 8
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
45
40
35
FRECUENCIA (%)
30
25 MUESTRA A.M
MUESTRA P.M
20
15
10
0
0
50
00
50
s
20
25
30
35
40
45
50
55
60
e
1
or
ay
M
SST (mg/l)
De igual m anera que sucede con la Turbiedad los SST de las Muestras P.M se
desplazan 50 mg/l a favor de las Muestras A.M debido a la singularidad en la
operación de la toma del agua residual en la PTAR El Salitre. El 39.5% de la
Muestras A.M poseen una concentración alrededor de 200 mg/l m ientras que el
30.5% de las Muestras P.M tienen una concentración superior de 250 mg/l.
Los SSV del afluente de la PTAR El Salitre describen un com portam iento m uy
similar al m ostrado por los SST. Se puede observar como a partir de septiem bre del
2002 aumenta la dispersión del parám etro característico de la materia orgánica en el
agua residual quizá debido a los procesos de hidrólisis que en determinado momento
se pueden estar llevando acabo durante la conducción de las aguas residuales
dom ésticas en el canal El Salitre, lo cual sum ado al paulatino descenso del pH y
aum ento de la alcalinidad fortalece esta hipótesis. A continuación se presenta dicho
com portam iento en la Figura 2.8.
__________________________________________________________________ 9
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
500
450
400
350
SSV (mg/l)
MUESTRA A.M
300
MUESTRA P.M
250
200
150
100
50
0
8/ 1
1
1
24 02
9/ 0 02
0/ 2
8/ 3
3
14 03
4
8/ 04
/9 04
7/ 4
8/ 5
9/ 05
4/ 5
0/ 2
5
7/ 00
1 1 20 0
2 / 20 0
0
1 0 20 0
4/ 00
2/ 00
5 / 20 0
/ 1 00
3 200
00
12 2 0
11 20
5 / 20
6 20
1 / 20
20
/2
/2
/2
/2
/2
12 /2
2
1/
1/
/
5
19
/5
13
/6
23
2
/1
/2
/2
1
2
4/
FECHA
45
40
35
FRECUENCIA (%)
30
MUESTRA A.M
25
MUESTRA P.M
20
15
10
5
0
0 50 100 150 200 250 300 350 400 450
SSV (mg/l)
__________________________________________________________________ 10
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Con el fin de estudiar aún m ás la dinám ica de los sólidos suspendidos, la relación de
SSV/SST se presenta la Figura 2.10 y la Figura 2.11, en las cuales se puede apreciar
el comportamiento histórico de esta relación y la frecuencia de dicho parám etro en el
afluente de la PTAR El Salitre.
1.0
0.9
0.8
0.7
SSV / SST
0.6
MUESTRA A.M
0.5
MUESTRA P.M
0.4
0.3
0.2
0.1
0.0
/6 3
14 3
4/ 004
05
28 01
/5 1
13 1
24 2
9/ 02
/10 2
3/ 002
28 3
8/ 04
/9 4
17 4
5/ 005
9/ 05
/1 05
10 00
1/ 00
11 00
2/ 00
5/ 00
12 200
6/ 00
2/ 00
0
0
20
0
0
20
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
2
1/
5/
4/
1/
20
28
19
23
11
4/
7/
12
FECHA
Figura 2.10 SSV/SST Afluente PTAR El Salitre.
60
55
50
FRECUENCIA (%)
45
40
35
MUESTRA A.M
30
MUESTRA P.M
25
20
15
10
5
0
es
0
9
0.
0.
0.
0.
0.
0.
0.
0.
0.
or
ay
M
SSV/SST
__________________________________________________________________ 11
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Este hecho se puede asum ir teniendo conocim iento del modo de operación de la
PTAR El Salitre, en cuanto a la tom a de agua, y al aum entó de frecuencia que se
presenta en el histograma de SSV/SST para las Muestras P.M (53.9 % para una
relación de 0.8) y así mismo la dism inución en la desviación de la curva de Gauss
haciéndola más em pinada respecto al comportamiento presentado por las Muestras
A.M.
650
600
550
500
450
DBO5 (mg-O2/l)
300
250
200
150
100
50
0
28 01
/5 1
2/ 001
24 2
9/ 02
/ 1 02
8/ 04
20 2
/9 4
17 4
28 3
28 5
/6 3
9/ 05
/ 1 05
14 3
05
23 4
11 00
5/ 00
3/ 00
0
2/ 00
6/ 00
5/ 00
10 00
1/ 00
4/ 00
0
0
12 20
0
20
0
20
/2
/2
/2
/2
/2
/2
2
/2
/2
/2
/2
/2
2
/2
/2
1/
0/
1/
5/
4/
19
13
11
4/
7/
12
FECHA
De acuerdo con la hipótesis presentada en la dinám ica de los sólidos suspendidos del
afluente de la planta de tratamiento, ésta se ve reafirmada con el comportamiento
histórico de la dem anda biológica de oxígeno, la cual presenta un sutil ascenso en los
últim os dos años y m edio. Debido a la hidrólisis que se lleva acabo en el canal El
Salitre, la DBO5 (tanto de las Muestras A.M com o P.M) aumenta gracias al
requerim iento adicional de oxígeno que dem andan los microorganism os para poder
estabilizar la m ateria orgánica. Este fenómeno ocurre por la dism inución en la
eficiencia de estabilización que los microorganism os pueden alcanzar entre una
materia orgánica seudo estabilizada y una no afectada por dicho proceso, considerada
com o un agua residual fresca.
__________________________________________________________________ 12
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
en prom edios m enores a los de las Muestras P.M, 34.2% para concentraciones de 300
mg/l y 9.9% para concentraciones de 350 mg/l, con respecto a frecuencias de un
31.2% para concentraciones de 300 mg/l y 22.3% para concentraciones de 350 m g/l.
40
35
30
FRECUENCIA (%)
25
MUESTRA A.M
20 MUESTRA P.M
15
10
0
0 50 100 150 200 250 300 350 400 450 500 550 600
D BO 5 (mg-O 2 /l)
__________________________________________________________________ 13
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
2500
2000
DQO (mg-O2 /l)
1000
500
0
01
01
01
02
02
02
02
03
03
03
04
0
20
0
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
1/
19
28
/5
13
24
/1 0
20
28
/6
14
9/
11
10
4/
7/
2/
5/
3/
6/
1/
12
FECHA
40
35
30
FRECUENCIA (%)
25
MUESTRA A.M
20 MUESTRA P.M
15
10
0
0
00
es
10
20
30
40
50
60
70
80
90
or
10
ay
M
__________________________________________________________________ 14
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
1.0
0.9
0.8
0.7
DBO5/DQO
0.4
0.3
0.2
0.1
0.0
1
03
4
00
00
00
00
00
00
00
00
20
20
/2
/2
/2
/2
/2
/2
/2
/2
/2
/
/
19
28
/5
13
24
20
28
/6
14
/1
9/
11
10
4/
7/
2/
5/
3/
6/
1/
12
FECHA
55
50
45
FRECUENCIA (%)
40
35
MUESTRA A.M
30
MUESTRA P.M
25
20
15
10
5
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
DBO 5 /DQO
__________________________________________________________________ 15
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
100
90
80
REMOCIÓN DE SST (%)
70
60
50 MUESTRA A.M
MUESTRA P.M
40
30
20
10
0
/1 4
07 04
0 8 /0 4
09 04
1 0 /0 4
1 1 /0 4
1 2 /0 4
0 6 /0 5
0 1 /0 4
0 7 /0 5
0 2 /0 5
0 8 /0 5
03 05
09 05
0 4 /0 5
1 0 /0 5
05 05
1 1 /0 5
1 2 /0 5
01 05
06
/0
7/
6/
2/
1/
3/
9/
8/
8
5
/1 4
/1 2
3
2
4
/1 0
0
3
9
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/0
/0
/0
05
06
FECHA
En la Figura 2.18 se ilustra el com portam iento que ha tenido la PTAR El Salitre en lo
que respecta a rem ociones de SST hasta el 31 de diciem bre de 2005. Se puede
apreciar lo disperso de los resultados obtenidos y se estim a un prom edio de 60%,
teniendo valores máxim os de remociones de hasta el 75% y m ínim os de 19.1%.
__________________________________________________________________ 16
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
40
35
30
FR EC UENCIA (%)
25
MUESTRA A.M
20
MUESTRA P.M
15
10
0
0 10 20 30 40 50 60 70 80 90 1 00
La rem oción de DBO5 presenta un com portam iento distinto al de los sólidos
suspendidos totales, pero coherente con las características ya estudiadas del afluente
de la planta de tratamiento, Figura 2.20.
100
90
REMOCIÓN DE DBO5 (%)
80
70
60
MUESTRA A.M
50
MUESTRA P.M
40
30
20
10
0
0 6 /0 4
07 04
0 8 /0 4
0 9 /0 4
1 0 /0 4
1 1 /0 4
1 2 /0 4
01 04
0 2 /0 5
0 3 /0 5
0 4 /0 5
0 5 /0 5
0 6 /0 5
07 05
0 8 /0 5
0 9 /0 5
1 0 /0 5
1 1 /0 5
1 2 /0 5
0 1 /0 5
06
7/
4/
2/
8/
8
5
/ 15
2
/ 14
9
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/0
/0
/0
05
FECHA
Com o se puede observar en la Figura 2.20 la difusividad de las Muestras A.M y P.M
es considerable, pero para mediados del año 2005 (julio a diciembre) se puede ver que
las Muestras A.M se mantienen constantes en un 40% aproximadam ente y las
Muestras P.M presentan un com portam iento aleatorio por encim a del 40% en su
mayoría.
__________________________________________________________________ 17
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
60
55
50
45
FRECUENCIA (%)
40
35
MUESTR A A.M
30
MUESTR A P.M
25
20
15
10
5
0
0 10 20 30 40 50 60 70 80 90 100
50
40
DOSIS DE FeCl 3 (mg/l)
30
MUESTRA A.M
MUESTRA P.M
20
10
0
0 6 /0 4
07 04
0 8 /0 4
09 04
1 0 /0 4
11 04
1 2 /0 4
01 04
0 2 /0 5
0 3 /0 5
0 4 /0 5
05 05
0 6 /0 5
0 7 /0 5
0 8 /0 5
0 9 /0 5
1 0 /0 5
1 1 /0 5
12 05
0 1 /0 5
06
7/
6/
5/
4/
3/
9/
8/
8
/ 13
2
/ 11
9
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/0
/0
/0
05
FE CHA
__________________________________________________________________ 18
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
22
20
18
FRECUENCIA (%)
16
14
12 MUESTRA A.M
10 MUESTRA P.M
8
6
4
2
0
es
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
ay 6
M 4
or
Se puede concluir que am bas cam panas de Gauss que se observan en el histograma
anterior (Muestras A.M y P.M) presentan el m ism o comportamiento.
__________________________________________________________________ 19
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
0.8
0.6
MUESTRA A.M
MUESTRA P.M
0.4
0.2
0.0
0 6 /0 4
07 04
0 8 /0 4
09 04
1 0 /0 4
11 04
1 2 /0 4
0 1 /0 4
0 2 /0 5
03 05
0 4 /0 5
0 5 /0 5
0 6 /0 5
0 7 /0 5
0 8 /0 5
0 9 /0 5
1 0 /0 5
11 05
1 2 /0 5
0 1 /0 5
06
7/
6/
5/
2/
0/
8/
8
4
/ 13
2
/ 12
9
/ 09
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/1
/0
/0
05
FECHA
En la Figura 2.24 se observa la dosis histórica de polím ero CIBA 1011 utilizado en la
planta de tratamiento. De la figura se puede apreciar como la dosis de polím ero
aparentemente presenta una correlación con respecto al com portam iento descrito
anteriormente por el cloruro férrico. Es claro que los valores observados presentan
una dispersión alta, y en los últimos dos meses del 2005 la dosificación de polím ero
dism inuyó sustancialmente (en un 33% aproxim adamente).
26
24
22
20
FRECUENCIA (%)
18
16
14 MUESTRA A.M
12 MUESTRA P.M
10
8
6
4
2
0
0. 5
5
25
0. 5
0. 5
0. 5
0. 5
5
25
5
25
0. 5
5
75
5
75
M 925
s
12
17
27
32
37
42
47
57
67
72
82
ore
0. 2
0. 5
0. 6
0. 7
0. 8
0.
0.
0.
0.
0.
0.
ay
POLIMERO (mg/l)
__________________________________________________________________ 20
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
8.5
8.0
7.0
6.5
6.0
/10 02
3/ 2 2002
28 3
/6/ 3
1/ 1 2003
23 4
28 1
/5/ 1
2/ 1 001
4/ 2 2
9/ 002
8/1 004
11 004
7/ 2 4
5/ 2 005
9/5 005
/14 5
05
6/ 200
10 200
4/ 200
7/ 200
11 200
5/ 2 00
2/ 1 200
12 / 200
12 / 20
/20
2
3/ 2
/2
/2
8/ 2
/
0/
4/
9/
/9/
1
4/ 1
FECHA
Figura 2.26 pH Efluente PTAR El Salitre.
__________________________________________________________________ 21
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
300
275
250
Alcalinidad (mg-CaCO3 /l)
225
200
175 MUESTRA A.M
150 MUESTRA P.M
125
100
75
50
25
0
20 2
6/2 2003
/6/ 3
1/1 003
3/ 4
7/2 001
/5/ 1
3/ 1
5/2 2002
9/1 002
/10 2
8/1 04
/9/ 4
2/1 2004
8/ 2 5
9/ 005
/14 5
5
3/ 200
10 00
4/2 00
11 200
2/1 200
12 / 200
11 200
5/2 200
12 / 200
00
20
8/ 2
2
4/ 2
9/ 2
4/ 2
/2
/
/
8/
7/
5
4/1
FE CHA
350
300
250
Turbiedad (NTU)
MUESTRA A.M
200
MUESTRA P.M
150
100
50
0
3/ 2 002
8/2 3
10 0 03
1/ 1 20 03
23 4
7/ 2 20 01
/5/ 1
2/ 20 01
5/ 2 20 02
9/ 0 02
/10 2
8/ 1 04
/9/ 4
2/ 1 20 04
5/ 2 0 05
9/ 0 05
/14 05
5
6/ 2 0 0
4/ 20 0
11 20 0
12 /200
00
11 200
/20
12 /20
4/2
/2
0/2
7/2
8/2
/2
/6/
4/
9/
8/
/
13
5
4/ 1
FECHA
Figura 2.28 Turbiedad Efluente PTAR El Salitre.
__________________________________________________________________ 22
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
50
45
40
FRECUENCIA (%)
35
MUESTRA A.M
30
MUESTRA P.M
25
20
15
10
5
0
0
25
50
75
es
10
12
15
17
20
22
25
or
ay
M
TURBIEDAD (NTU)
__________________________________________________________________ 23
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
200
175
150
125
S ST (mg/l)
MUESTRA A.M
100
MUESTRA P.M
75
50
25
0
8/ 1
/5 1
13 1
24 02
9/ 002
0/ 2
0/ 2
/2 03
/6 3
14 03
23 4
8/ 04
/9 04
17 4
28 5
9/ 05
4/ 5
5
7/ 00
11 200
2/ 200
/1 0
3 200
10 200
4/ 00
2/ 00
5/ 200
/ 1 00
00
5/ 20
12 20
6 20
1/ 20
0
11 0
0
/2
/2
/2
/2
2
/2
/2
12 /2
2
1/
1/
8/
/
/
5
19
2
/2
4/
FECHA
60
55
50
FRECUENCIA (%)
45
40
35 MUESTRA A .M
30
MUESTRA P.M
25
20
15
10
5
0
0 25 50 75 100 125 150 175 200 225
SST (mg/l)
__________________________________________________________________ 24
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
De igual m anera que sucede con la Turbiedad los SST de las Muestras A.M y P.M
describen un m ism o comportamiento. En el histogram a de la Figura 2.31 se puede
ver que el 52% de la Muestras A.M y el 53% de las Muestras P.M poseen una
concentración alrededor de 100 mg/l.
200
175
150
125
SSV (mg/l)
MUESTRA A.M
MUESTRA P.M
100
75
50
25
0
23 4
8/ 1
/5 1
13 1
24 2
9/ 02
0/ 2
20 2
8/ 3
/6 3
14 03
8/ 004
/9 04
7/ 4
28 05
9/ 05
/ 1 005
05
7/ 00
11 200
2/ 200
5/ 200
/ 1 00
3/ 00
6/ 200
10 200
4/ 00
2 200
0
1/ 20
11 20
5/ 20
0
20
/2
/2
12 /2
/2
/2
/2
12 /2
2
1/
/
4/
19
5
2
/1
4/
FECHA
Figura 2.32 SSV Efluente PTAR El Salitre.
60
55
50
FRECUENCIA (%)
45
40
MUESTRA A.M
35
30 MUESTRA P.M
25
20
15
10
5
0
0 25 50 75 100 125 150 175
SSV (mg/l)
__________________________________________________________________ 25
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
450
400
350
300
DBO5 (mg-O2/l)
MUESTRA A.M
250 MUESTRA P.M
200
150
100
50
0
28 1
/5 1
2/ 001
24 2
9/ 02
/1 02
20 2
28 3
/6 3
14 3
23 4
8/ 04
/9 4
17 4
28 5
9/ 05
/1 05
05
7/ 00
11 00
5/ 00
3/ 00
6/ 00
10 00
1/ 00
4/ 00
0
2/ 00
5/ 00
0
12 20
0
20
0
12 20
20
/2
/2
/2
/2
/2
2
/2
/2
/2
/2
/2
/2
/2
/2
0/
4/
1/
1/
5/
19
13
11
4/
FECHA
__________________________________________________________________ 26
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
35
30
25
FRECUENCIA (%)
20 MUESTRA A.M
MUESTRA P.M
15
10
0
0 25 50 75 100 125 150 175 200 225 250 275
__________________________________________________________________ 27
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
3. METO DO LO G ÍA
La Planta Piloto TPQA esta constituida grosso m odo por una estructura de captación
y m edición, un tanque de mezcla rápida, tres tanques para la floculación, un tanque
sedim entador, una estructura para la dosificación de quím icos, una estructura m etálica
de soporte y un tanque para la medición y disposición del efluente al alcantarillado
interno de la PTAR El Salitre (com o se ilustra en la Figura 3.1 y 3.2).
__________________________________________________________________ 28
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
__________________________________________________________________ 29
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Características Constructivas
Forma: cuadrada, fondo plano.
Dimensiones: 0.6m x 0.6m x 0.56m
(AxLxH).
Construcción: FRP.
Conexiones: tubería de 3”
(entrada/salida), tubería de drenaje 2”.
Agitador: Tipo hélice, SS316.
Velocidad de Rotación: 1,450 RPM
(variable).
Motor: 0.4 HP.
Especificaciones de Diseño
Tiempo de retención mínimo: 60 seg.
Ajuste tiempo retención: m ediante
válvulas localizadas en 2 niveles.
2. TANQUES DE FLOCULACIÓN
Características Constructivas
Forma: cuadrada, fondo plano.
Dimensiones: 1.0m x 1.0m x 1.5m
(AxLxH).
Construcción: FRP.
Conexiones: tubería de 3”
(entrada/salida), tubería de drenaje 2”.
Agitador: Tipo hélice, SS316.
Velocidad de Rotación: 250 RPM
(variable).
Motor: 0.6 HP.
Especificaciones de Diseño
Tiempo de retención total: 10 m inutos
por tanque.
Ajuste tiempo retención: m ediante
válvulas localizadas en 5 niveles.
3. ESTRUCTURA DE SOPORTE
Características Constructivas
Plataform a superior provista de
pasarela y patas de soporte al piso.
Dimensiones: 9.0 x 2.5 x 1.9m
(LxAxH).
Estructura en acero al carbono, piso en
rejilla galvanizada.
__________________________________________________________________ 30
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
4. TANQUE DE SEDIMENTACIÓN
Características Constructivas
Forma: cilíndrico vertical, fondo
cónico
Diámetro: 2 m Altura cilindro: 1.9
m
Construcción: Acero.
Conexiones: tubería de 3”
(entrada/salida), tubería de drenaje 2”.
Barredor de lodos: Accionamiento
central.
Velocidad de Rotación: 0.3 RPM (fija).
Motoreductor: 0.3 HP.
Especificaciones de Diseño
Carga superficial: 1.24 m3/m2h
Tiempo de retención: 1.66 horas.
__________________________________________________________________ 31
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Compresor
Capacidad: 10 CFM, 125 psi.
Tanque horizontal de 35 galones.
Lubricado con aceite.
Válvula de seguridad.
Motor: 2 HP.
7. BOMBAS DOSIFICADORAS
Cloruro Férrico
Bomba peristáltica Watson Marlow.
Modelo: 520SN/R2, 220 rpm.
Capacidad: 50 - 700 m l/m in.
Polím ero
Bomba peristáltica Watson Marlow.
Modelo: 520SN/R2, 220 rpm.
Capacidad: 5 - 300 ml/min.
__________________________________________________________________ 32
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Estos caudales presentados anteriorm ente serán objeto de estudio a lo largo del
proyecto de investigación.
Para el tanque de m ezcla rápida se encuentran dos válvulas para el efluente ubicadas a
una altura del fondo del reactor de 0.18 m y 0.36 m garantizando una mezcla
com pleta libre de cortocircuitos para unos volúmenes de 64.9 L y 129.8 L,
respectivam ente.
Para los tres tanques floculadores que se encuentran en serie se tienen cinco válvulas
para el efluente de los reactores ubicadas a las siguientes alturas del fondo y
volúmenes del tanque.
Por último, el tanque de sedim entación de la planta piloto fue diseñado para operar a
la m ism a velocidad ascensional a la cual operan actualm ente los sedim entadotes de la
PTAR El Salitre (1.24 m3/m2h). Cuenta con un volumen de 6.46 m 3 y para el caudal
mínimo de la planta piloto de 1.08 l/s posee un tiem po de retención de 1.66 horas.
La operación de la Planta Piloto TPQA para el presente estudio fue realizada para
todos los caudales presentados anteriorm ente con un tiem po de retención en los
tanques de floculación de 30 m inutos (WEF Manual of Practice No. 8 Fourth Edition,
1998) y una velocidad de agitación de 100 rpm; un tiem po de mezcla rápida ajustado
para los tres caudales inferiores en el nivel m ínim o de la válvula del reactor y para los
dos caudales superiores en el nivel máximo de la válvula con una velocidad de
agitación de 350 rpm (Rossini et. al.,1999). La dosis de coagulante (Cloruro Férrico)
fue variada a lo largo del cronograma de muestreo (0,10,20,25,30,35,40,45 mg/l) y la
__________________________________________________________________ 33
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
de polím ero (CIBA 1011) se m antuvo en 0.5 mg/l com o dosis crucero promedio
utilizada en la PTAR El Salitre (Leentvaar et.al., 1979).
Inicialm ente la planta piloto operó de 8:00 a.m. a 5:00 p.m . y eventualm ente se
decidió mantener una operación de 24 horas durante la segunda fase de ensayos para
el desarrollo, alimentación de datos y calibración del m odelo. Para la obtención de
datos a utilizar en la validación del m odelo se propuso una tercera cam paña intensiva
en la cual se operó la planta piloto de 8:00 a.m. a 5:00 p.m ., los detalles de los
ensayos realizados y las características de estas cam pañas de m onitoreo se presentan
en el siguiente numeral.
Durante los meses de junio a octubre de 2005 se realizó la prim era fase de los ensayos
experim entales de la planta piloto, seguidos de la segunda fase com prendida entre los
meses de diciem bre de 2005 a principios de enero de 2006 (6 de enero de 2006), la
ultim a fase se llevó acabo en el m es de abril de 2006 y tuvo un período de ejecución
de 3 semanas. Los ensayos realizados en las tres diferentes cam pañas de m uestreo
fueron los siguientes:
__________________________________________________________________ 34
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
_________________________________________________________________ 35
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
_______________________________________________________________ 36
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
4. RESULTADO S Y ANÁLISIS
Una vez culm inadas las tres campañas de monitoreo se procedió a organizar la
información m uestreada, evaluar las condiciones de la planta piloto e identificar los
parámetros para el desarrollo del modelo de dosificación, mediante la utilización de
una herramienta de análisis estadístico.
Durante las etapas experim entales, la planta piloto alcanzó rem ociones m áximas del
75% de SST, dependiendo de la calidad del afluente y la dosificación de cloruro
férrico em pleada. El afluente a lo largo del estudio presentó las siguientes
caracteríticas promedio:
500
450
400
350
SST (mg/L)
300
250
200
150
100
50
0
5/28/2005 7/17/ 2005 9/ 5/2005 10/25/2005 12/14/2005 2/2/ 2006 3/24/2006 5/13/2006 7/ 2/2006
FECHA
_______________________________________________________________ 37
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
18
16
14
FRECUENCIA (%)
12
10
8
0
100
120
140
160
180
200
220
240
260
280
300
320
340
360
380
400
420
440
460
480
500
520
540
Mayores
SST (mg/l)
Teniendo en cuenta esta hipótesis se cree que la fracción sedimentable puede estar
siendo dism inuida por la hidrolización de la materia orgánica debido a los altos
tiem pos de retención del agua residual en el canal Salitre. Aspecto el cual puede
llegar perturbar la eficiencia de este tipo de tratamientos químico dependiendentes.
Esta teoría se puede relacionar con la dism inución de la fracción de SSV/SST del
afluente de la PTAR El Salitre en los últimos cinco años (Figura 2.10).
350
300
TURBIEDAD (NTU)
250
200
150
100
50
0
5/28/2005 7/ 17/2005 9/5/2005 10/25/2005 12/14/2005 2/ 2/2006 3/24/2006
FECHA
_______________________________________________________________ 38
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
7.70
7.60
7.50
7.40
7.30
pH
7.20
7.10
7.00
6.90
6.80
5/28/2005 7/ 7/2005 8/16/2005 9/25/ 2005 11/ 4/2005 12/ 14/2005
FECHA
27.0
TEMPERATURA (°C)
25.0
23.0
21.0
19.0
17.0
15.0
5/28/2005 7/7/2005 8/16/ 2005 9/25/2005 11/4/2005 12/14/ 2005
FECHA
_______________________________________________________________ 39
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
1215
CONDUCTIVIDAD (mS/cm)
1015
815
615
415
215
15
5/ 28/2005 7/17/2005 9/5/2005 10/25/2005 12/14/2005 2/ 2/ 2006 3/24/2006 5/13/ 2006 7/2/2006
FECHA
FECHA
5/ 28/2005 6/17/2005 7/ 7/ 2005 7/27/2005 8/16/2005 9/5/2005
0
POTENCIAL REDOX (mV)
-50
-100
-150
-200
-250
-300
Los valores máxim os presentados por la tem peratura, conductividad y potencial rédox
fueron 25 °C, 1018 m S y -33 mV; de la misma manera los mínim os fueron 17.9 °C,
232 mS y -294 mV, respectivam ente.
_______________________________________________________________ 40
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Por último, las características promedio del efluente de la planta piloto TPQA durante
la realización de todos los ensayos son los siguientes:
1. Los SST se pueden estim ar mediante la turbiedad, ningún otro parámetro incurre
en su predicción.
500
450
400
350
SST (mg/L)
300
250
200
150
100
50
0
0 25 50 75 100 125 150 175 200 225 250 275 300 325
TURBIEDAD (NTU)
Com o se puede observar en la Figura 4.8, los SST y la turbiedad del agua residual
guardan una estrecha relación lineal. La dispersión en los datos correlacionados es
una característica intrínseca de la conducta que presenta este tipo de sistem as.
_______________________________________________________________ 41
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
2. La DBO5 se puede estimar usando los SST y la conductividad del agua residual.
Figura 4.9 Estimación de la DBO5 utilizando los SST y conductividad del afluente
de la Planta Piloto TPQA.
Figura 4.10 Estimación de la DBO5 utilizando los SST y conductividad del afluente
de la PTAR El Salitre.
Com o lo ilustra la Figuras 4.9 esta estim ación para los datos analizados en la planta
piloto TPQA es satisfactoria con un coeficiente de correlación de 0.798 utilizando un
modelo de baja com plejidad y de 0.969 con un polinom ial. Con el fin de confirmar
este com portam iento se correlacionaron los datos históricos de la PTAR El Salitre y
se encontró la misma conducta. En la Figura 4.10 se puede observar la dependencia
_______________________________________________________________ 42
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Com o ejem plo de este comportamiento se ilustran los resultados obtenidos en las
correlaciones del potencial rédox, la conductividad, la DQO y el caudal a lo largo del
estudio.
-325 -300 -275 -250 -225 -200 -175 -150 -125 -100 -75 -50 -25 0
90
80
SST
50-100 mg/l
70
100-150 mg/l
REMOCIÓN (%)
60 150-200 mg/l
200-250 mg/l
50
250-300 mg/l
40 300-350 mg/l
20
10
90.0
80.0
SST
70.0 50-100 mg/l
REMOCIÓN (%)
20.0
10.0
0.0
0 100 200 300 400 500 600 700 800 900 1000
CONDUCTIVIDAD (mS)
_______________________________________________________________ 43
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
90
80
70
SST
50-100 mg/l
REMOCIÓN (%)
60
100-150 mg/l
50 150-200 mg/l
200-250 mg/l
40 250-300 mg/l
>300 mg/l
30
20
10
0
0 100 200 300 400 500 600 700
DQO (mg/l)
90
80
SST
70 50-100 mg/l
100-150 mg/l
REMOCIÓN (%)
60
150-200 mg/l
50 200-250 mg/l
250-300 mg/l
40 300-350 mg/l
>350 mg/l
30
20
10
0
0.5 0.7 0. 9 1.1 1.3 1.5 1.7 1.9 2. 1 2.3
CAUDAL (l/s)
Para los diferentes escenarios analizados en los ensayos se encontró que el caudal no
incide de m anera alguna en el desempeño de la planta TPQA debido a que la dosis de
cloruro férrico fue m odificada autom áticam ente, acorde con el caudal de ingreso.
Este hecho, el cual no sucede en una planta de tratamiento a escala real, puede
diezmar el efecto que tiene el caudal afluente. Un exceso o dism inución en los
tiem pos de retención de los floculadores puede fracturar el floc o evitar su adecuada
conform ación, respectivam ente, reduciendo la eficiencia del sistema. Este efecto pasa
_______________________________________________________________ 44
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
4. Los SST y la turbiedad parecen ser los únicos parám etros que afectan están
relacionadas directam ente con la eficiencia de la planta piloto bajo las
condiciones específicas de operación del sistema.
90
80
70
COAGULANTE
10 mg/l
REMOCIÓN (%)
20 mg/l
60
25 mg/l
50 30 mg/l
35 mg/l
40
40 mg/l
30 45 mg/l
Sin Coagulante
20
10
0
0 50 100 150 200 250 300 350 400 450 500
SST(mg/l)
_______________________________________________________________ 45
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
5. El nivel del canal introduce un ruido aparente en el com portam iento del proceso,
el cual se debería confirmar en el desarrollo del m odelo.
100
90
80 SST
REMOCIÓN (%)
50-1 00 mg/l
70
100- 150 mg/l
60 150- 200 mg/l
50 200- 250 mg/l
250- 300 mg/l
40
300- 350 mg/l
30 > 40 0 mg/l
20
10
0
50
75
00
25
50
5
.7
.0
.2
.5
.7
.0
.2
.
.
69
69
70
70
70
71
71
71
71
72
57
57
25
25
25
25
25
25
25
25
25
25
2
Figura 4.17 Relación del nivel del canal y los SST en la eficiencia sistema.
_______________________________________________________________ 46
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Com o se puede observar en la Figura 4.17, el nivel del canal de cierta manera incide
en el desem peño de la planta piloto. De acuerdo con un nivel bajo en el canal (cotas
2569.75 m – 2570.50m) y una concentración de 150 mg/l de SST en adelante se
pueden esperar rem ociones de SST del orden del 50% al 80%. Mientras que para
niveles altos del canal (cotas 2751.0 en adelante) con concentraciones particulares
menores 200 m g/l de SST para estos casos, la remoción de la planta de tratamiento
escasam ente alcanzará el 60% de SST. La importancia en la medición de este
parámetro para la simulación de la planta piloto debe de ser verificada, con el fin de
determinar su inclusión en el modelo de dosificación.
_______________________________________________________________ 47
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Al implem entar estas dos técnicas de manera simultánea surge una arquitectura
híbrida de inteligencia artificial conocida como ANFIS (Adaptive Neuro-Fuzzy
Inference System). Esta técnica perm ite obtener las ventajas de las dos arquitecturas,
proveyendo al modelo las características para adaptarse a los escenarios estudiados
conform e el transcurrir del tiem po.
_______________________________________________________________ 48
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
En las Figuras 5.3 y 5.4 se puede apreciar el número de reglas relacionadas para cada
modelo (rules) y el número de funciones de membresía asociadas a éstas (input m f).
Estas reglas y funciones de membresía se estimaron inicialmente de acuerdo al
com portam iento de los datos analizados, y posteriorm ente se fueron ajustando de
acuerdo con el desem peño alcanzado por el modelo durante la etapa de calibración.
_______________________________________________________________ 49
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
_______________________________________________________________ 50
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Una vez determ inadas las estructuras de los dos modelos se realizó la calibración de
ambos, a través del ajuste de sus respectivas funciones de m em bresía. Este
procedim iento se realiza autom áticamente en Matlab mediante una aplicación
iterativa que converge las funciones de m embresía (cam bian su forma) hasta alcanzar
un error mínim o de la raíz m edia cuadrada (RMSE) constante. Para la calibración se
utilizó el 80% de los datos muestreados en las campañas experimentales, 235 pares de
muestras de entrada y salida de la planta piloto por cada parám etro. En las Figuras
5.7-5.10 se presentan las superficies envolventes para cada modelo, una vez habiendo
_______________________________________________________________ 51
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
definido las mejores opciones de funciones de m em bresía que se ajustan a cada caso.
Para el modelo No.1 se tiene una superficie y tres para el modelo No.2, por la
diferencia de parámetros.
_______________________________________________________________ 52
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Com o se puede apreciar de las figuras anteriores, las superficies representan m uy bien
el comportamiento de la planta piloto TPQA, exceptuando los valores encontrados a
concentraciones superiores de 400 mg/l para los SSTa y dosificaciones inferiores a 20
mg/l de cloruro férrico. Este error es muy común en este tipo de m odelos y se debe al
_______________________________________________________________ 53
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Para la validación de los dos modelos propuestos se utilizó el restante 20% de datos
obtenidos en las campañas de monitoreo, los cuales equivalen a 53 pares de m uestras
de entrada y salida de la planta piloto por cada parámetro y se sim uló el
com portam iento. Los resultados encontrados para am bos m odelos se presentan a
continuación en las Figuras 5.11 y 5.12.
En el escenario sim ulado, el m odelo No.1 obtuvo un RMSE de 19.96 m g/l en los SST
del efluente de la planta piloto, m anteniendo el error encontrado en la calibración. El
modelo No.2 igualm ente conservó la condición descrita con un RMSE de 20.48 m g/l.
_______________________________________________________________ 54
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
Se cree que este error puede ser dism inuido mediante la utilización de sondas para la
medición en línea de los SST en la planta piloto (Schutze et. al., 2001), las cuales
perm itan relacionar un menor error en la medición y robustecer con un mayor núm ero
de datos la alim entación y calibración de los modelos. Sin em bargo, un error de esta
magnitud afecta m uy poco el valor de dosificación de coagulante necesario para
mantener un sistem a eficiente (0.5-1 mg/l de cloruro férrico). Con un mayor núm ero
de datos adquiridos a través del funcionam iento, el m odelo de dosificación podrá
adaptarse a los escenarios propiciados en la operación convencional de una planta de
tratamiento químicamente asistida.
Finalmente, se puede ultim ar que el parámetro del nivel del canal de aproximación de
la PTAR El Salitre no incide significativamente en el desem peño de la planta piloto,
debido a que los resultados del m odelo No.1 y No. 2, prácticamente no difieren en
cuanto a su magnitud de error. El m odelo de dosificación de una planta piloto TPQA
depende primordialmente de la concentración de los SST en su afluente y la
dosificación de coagulante utilizado.
_______________________________________________________________ 55
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
6.1 Conclusiones
_______________________________________________________________ 56
UNIVERSIDAD DE LOS ANDES. MIC 2006-II-13
Departamento de Ingeniería Civil y Ambiental._____________________________________
7. BIBLIO GRAFÍA
_______________________________________________________________ 57