is used to sterilise operating equipment, boilers are generally used (Figure 1). In
and steam supplies the adjoining large- comparison to water tube boiler systems Inadequate water quality, resulting in
scale kitchens or is used for these are by far the better alternative, in corrosion or the formation of deposits,
humidification of the air conditioning the relevant performance range, because is top of the list in the damage statistics.
system. The building materials industry they are cheaper to buy and to run. The results of this type of damage are
needs saturated steam for many process, generally known in the industry, and will
heating and drying procedures, such as Operating modern shell steam boiler therefore not be discussed in greater
the autoclaving of sand-limestone systems is regarded as unproblematic detail in this specialist report. "Poor"
bricks. And in many other sectors, such nowadays. Nonetheless, these boilers are water quality is often caused by any or all
Figure 3: Modern LOOS INTERNATIONAL steam boiler system with fully automated water analysis and monitoring
material fatigue over the course of time. · the use of burners with a high If the spread between PBurner.on and PBurner.off
In addition to increasing the system's regulating range is set too low, the consequences will be
susceptibility to damage, this operating as follows:
system also has a negative effect on · the modification of the burner
economic efficiency, since every capacity to actual requirements (i.e. · Frequent switching on and off
preventilation process causes a burner modification or the provision caused by overshooting of the
considerable loss of heat. of a burner with a smaller output pressure and thus to the temperature
range) change stresses described in 2.1, with
For this reason, burner switching cycles their negative consequences
of £ 4 per hour should be aimed at. 2.2 Insufficient pressure difference
between burner switch-on and burner · Mandatory “strict” regulation
To achieve this, the following steps are parameters in the output controller in
switch-off
recommended order to keep the setpoint value in a
As is already known, the performance tight regulation range. The result, in
· the installation of low-load controls
of the steam boiler is regulated via the addition to excessive wear on the
which delay the immediate adjusting
steam pressure measured in the boiler. If control elements in the burner, is
up after the burner start
the level falls below the adjustable steam premature material fatigue of the
· the use of output controllers which pressure PBurner.on the burner is switched heated walls (see also 2.3)
enable the burner to be left in the low- on if PBurner.off is exceeded, the burner is
Experience has shown that with a set
load position for an unlimited period switched off. spread of 10 to 15% between PBurner.on and
of time
PBurner.off (depending on the burner
regulation and burner operating
pressure) in relation to the boiler
safeguard pressure, this problem can be
reliably avoided.
10
8
Steam volumes in t/h
0
11:00 11:29 11:59 12:29 12:59
Time
Boiler 1 Boiler 2 Total volume of steam
Nominal output 10 t/h Nominal output 6 t/h
Diagram 1: Record of steam output in a boiler system with 2 steam generators without sequence control concept
the greater temperature difference In the case of very frequent cold starts, load removal as a function of water
between the flame tube and boiler shell these extreme changeover stresses can temperature and pressure so that
at the cold start compared with standard lead to cracking of the material, or, in the stresses are kept to a minimum
operation at operating temperature. The worst case, to complete failure of the
3.2 Long periods on stand-by
flame tube thrust (difference between system.
change in length of the boiler shell and During heat maintenance or stand-by
The following should be noted if the
the flame tube) is higher during the start- operation (e.g. in multiboiler operation,
start-up load is to be reduced:
up process, which leads to considerable if the secondary boiler is not required),
additional strains which the boiler body · start-up from cold state to operating the boiler cannot give off any steam.
has to deal with. This problem is even temperature with the smallest Depending on the control concept,
more acute if, during the start-up possible burner load either the steam removal valve is closed
procedure, steam bubbles cannot form · During the start-up procedure, a or the secondary boiler is run at a lower
or can only form to a limited extent, small quantity of steam should always pressure than the prevailing network
which is the case, for example, if the be able to flow off in order to start pressure. The burners only switch on
steam removal valve is closed. The the natural circulation through sporadically in this operating mode, in
natural circulation that normally exists in pushing up the steam bubbles. order to compensate losses from heat
the steam boiler (Figure 5) does not conduction and radiation. If this state is
occur, resulting in temperature layering · Ideally, the system should be fitted maintained over any length of time (> 3
in the boiler (cold at the bottom, hot at with an automatic start-up switch, days), temperature layering starts to
the top) with additional thermal stresses. which regulates burner operation and occur in the boiler. If bo ilers that are
kept warm in this way are then switched
to normal operation, the high operating
pressure (hot upper area) makes it seem
as if a boiler is available immediately.
The boiler control will then apply a high
burner load to this boiler in a very short
time if there is a corresponding
requirement. As a result of the
temperature layers in the boiler, extreme
thermal stresses will then occur, as
described in 3.1.
The illustrations shown here are given by way of example and are not binding.
GERMANY Via Badia, 74 Proezd Serebryakova 6
Tel. +49 9831 56253 25060 Cellatica BS 129323 Moscow Chech Republic
Fax +49 9831 5692253 ITALY RUSSIAN FEDERATION Kotle-Loos spol. s r.o
eMail: sales@loos.de Tel. + 39 030 322191 Tel. +7 495 7821254 Bezová 1 èp. 1658
Internet: www.loos.de Fax +39 030 3732693 Fax +7 495 7821174 147 14 Prague 4
eMail: vendite@loositalia.it eMail: loos@loosrussia.ru CZECH REPUBLIC
France Internet: www..loositalia.it Internet: www.loosrussia.ru Tel. +420 244112111
Loos France SAS Fax +420 244112150
Zone d’activités Austria Skandinavia eMail: info@loos.cz
12, rue de Guebwiller Loos Austria GmbH Loos Scandinavia A/S Internet: www.loos.cz
BP74 Wattwiller Haldenweg 7 Stenløse Center 18 D, 1.
68702 Cernay Cedex 5500 Bischofshofen 3660 Stenløse PR China
FRANCE AUSTRIA DENMARK Loos China Ltd.
Tel. +33 3 89758484 Tel. +43 6462 2527310 Tel. +45 47107100 Room 1301, 13/F.,
Fax +33 3 89758480 Fax +43 6462 252766310 Fax +45 47108011 Ho Lik Centre,
eMail: loos@loos-france.fr eMail: vertrieb@loos.at eMail: loos@loos.dk 64-66 Sha Tsui Road,
Internet: www.loos-france.fr Internet: www.loos.at Internet: www.loos.dk Tsuen Wan, N.T. HK
Hong Kong
Greece Poland Slovakia PR CHINA
Loos Hellas EPE Loos Centrum Sp.z o.o KOTLE – Loos Slovakia, s.r.o. Tel. +85 229769177
Solonos 68 ul. Marii Kazimiery 35 Einsteinova 1 Fax +85 228933924
10680 Athens 01-641 Warsaw 851 01 Bratislava eMail: loos@loos.china.biz.com.hk
subject to change
GREECE POLAND SLOVAKIA Internet: www.loos.cn
Tel. +30 2103616090 Tel. +48 22 5619090 Tel. +421 2 67200040
Fax +30 2103618353 Fax +48 22 5619099 Fax +421 2 62524694
eMail: looshel@otenet.gr eMail: loos@loos.pl eMail: info@loos.sk In addition, agencies in almost all
Internet: www.loos.gr Internet: www.loos.pl Internet: www.loos.sk countries of the world.
Internet: www.loos.de
The production of this brochure consumes valuable raw materials. Please consider
the possibility of multiple use and pass it on to other people who might be interested. The Boiler Company