You are on page 1of 55

 Hongxin




All-new, energy saving, high efficiency, and low noise

Lead the new trend of fans for mining use

宏 信 通 风 设 备
Hongxin Ventilation Equipment

 !
Shanxi Yuncheng Hongxin Ventilation Equipment Co., Ltd
"#$%
&'()*+,- —— ./012345,6789:;<01=>?01@ABCD01E
FGHIJ./<0KLMNOP2QRSTUVWXYZ[\QE]^_`a=bcd\A
efghijkl2mM 209 &?=\IAn=IoAnopOqrstuvwxEy<z{=/
|}~ESTY€U2‚ƒ„…†Z[‡Ywˆ‰ŠE
‹ŒŽ24‘_’“”8=>?‹K@•–—˜2™\gš›eœ2žA,-fgŸ
 E¡¢‡£=¡¢fgi¤4=¥¦§¨E©ªr«,-M¬­=89:;<01 FBCDZ =
FBCZ =FBD o\®¯°±²,-³´Eµ=>?¶·39¸¹<01 SDF(A) =SDF(B) =SDF(C) =
SDF(D), >?Iˆ39º¹<01 SSF Eo=ABCD01 GPF o\®¯»¼½-²E¾=¿À0
1EÁ=ÂÃ01EÄMÅÆÇ¢=È ÉÊ=ËÌeÍÎÏ)E+ÐÑÒ9ÓÔÕEw “Ö&Ö
×,-È —ØÖÀ ”ÙÚ2ÕÊÛ “/Üx,-*+ÝÞ ”E,-ßàáâ&µ¼ã½H=§@Q
jEäOP01åæç9„&èegš2,-u”8=>?=•–é‰6½êëìíÑÒîïE
äOP “.\Y/ï=ðñYgš=òÀYóô ”Ûõö2÷ø./ùúEûüâý6þMÿ
kFü =ߛE
Company profile
As the owner of Hongxin fans, the key product specially promoted by the nation, the Company specializes in the
production of various explosion-proof fans for mines, tunnel fans and high pressure spray fans.
Shanxi Yuncheng Hongxin Ventilation Equipment Co., Ltd locates in the east of the Yellow River with long
history of civilization. It is between two large high-tech development zones of Salt Lake and Xia County. Three main
lines, including 209 National Highway, Datong-Yuncheng Highway and Yuncheng-Sanmenxia Highway go across this
place. In addition, it boasts of convenient transportation and communication. The time-honored culture of Shanxi
merchants exerts influence on operation principle of modern people in the east of the Yellow River.
Since the establishment, the Company strengthens technical innovation and increases technical content of
products for serving mines, tunnel construction and environmental protection. It aims to achieve development and
expands market by depending on talents and science and technology. Currently, it has developed main products
including: 1. Explosion-proof fans for mines FBCDZ, FBCZ and FBD three large series totaling more than hundreds
of product models; 2. Special axial flow fans for tunnel construction SDF(A), SDF(B) , SDF(C) and SDF(D), and
special jet fans SSF for tunnel operation; 3. High pressure spray fans GPF three series totaling scores of
varieties;4.Centrifugal fan ;5 Roots blowers.The products have the characteristics of reliable performance, stable
quality and novel structure, and are well received by users. After being reviewed by CQGC, the Company is rated as
"Trustworthy Product Promotion Unit". The products have been sold to more than 20 provinces, cities and regions.
The fan impellers of the Company adopt new international technology, and the products are highly commended in
such fields as mines, tunnels and environmental treatment.
The Company is committed to building Hongxin brand with "Great Reputation, Excellent Technology and
Careful Polishing". We are willing to advance with times and create the brilliancy together with far-sighted people
from various fields in the world.
  / Contents


 Chapter I Explosion-proof fans for mines
1 Product display
2
 Characteristics of explosion-proof fans for mines
3FBCDZ   
FBCDZ series explosion-proof draw-out counter-rotating axial-flow fans
4FBD ! "# $%
FBD series explosion-proof press-in counter-rotating axial-flow local fans
%&'( Introduction of parts
5
6)*+, Main auxiliary products
- ./ Chapter II Tunnel fans
1SDF(A)./012  
SDF(A) special axial flow fans for tunnel construction
2SDF(B)./012  
SDF(B) special axial flow fans for tunnel construction
3SDF(C)./012  
SDF(C) special axial flow fans for tunnel construction
4SDF(D)./012  
SDF(D) special axial flow fans for tunnel construction
5SFC 3./012  
SFC special draw-out axial flow fans for tunnel construction
4  Jet fans
6
5 6"78 Chapter III High pressure spray fans
1 Characteristics
29 :; Applicable scope
33<=>? Explanation of markings of fan type
4GPF 6"78@ABCD
Technical parameters table of GPF high pressure spray fans
5GPF 6"78EGHIJK
Schematic diagram of outline structure of GPF high pressure spray fans
6GPF 6"78EGLMD
Outline dimension table of GPF high pressure spray fans
NOP QRSTUVW
Chapter I Explosion-proof fans for mines

1XYZ[\ Product display


2]^_`abcdef 2. Characteristicsofexplosion-prooffansformines
The FBCZ, FBCDZ and FBD series fans
ghijkl FBCZmFBCDZmFBD no manufactured by the Company have the
pqrstuvwxyz{|w}~€ following characteristics in the aspects of
structure and various performances:
‚ƒ 2.1 The fans of various series all use the

2.1.yopqrs„…†‡ˆs‰Š‹Œ
simplest transmission device of direct connection
between motor and impeller.
lŽ‘ˆuv’ 2.2. Wing twisted blades are used, which have
high aerodynamic efficiency. The static pressure
2.2.…†s“”•–Š—˜™ˆš›œ˜ efficiency of single-stage series fan and
opqrsxžŸopqrs ¡l¢£ counter-rotating series fan devices is as high as
above 80%, thus the high efficiency area is wide
š›œ¤ 80%w˜œš¥¦§˜¨|š©ª and energy saving effect is obvious.

«’ produced with cylinder wall, and then accident is


caused, and make the operation of fans be safer
2.3.¬­†qrs®†¯°±‡ˆs˜²¡ and more reliable.
2.3 Fans for mines select explosion-proof
‡ˆs³qrsl¯´µ¶˜·¸¹r´‰r motors and put motors in isolating chambers of
s´º»¼½¾l™´¿À¯Á˜ÂÃÄŹ fans to ensure the isolation between wind current
and air flow containing gas in fan flow channel
ÆÇÈ´lɆ˜Êr´Ë̇ˆsÍÎ‰Ï and meanwhile, play heat dissipation and

™¿q˜ÐÑÒ¹‡ˆslÓÔ{|˜Õ̇ diversion function. The wind current pipe makes


the surrounding area of motor is connected with
ˆslÇ֌×ÆØÅٙ»˜ÑÒ¹qrs atmosphere, which both increases the safety
performance of motor and directly dissipate the
ÚÛlÓÔ{’ heat of motor to air and improve the safety of fan
2.4.t¬­†qrsŠ‹ÜÝÞàláâw˜ operation.
2.4 In the cylinders of rotating parts of
ÑÒ¹ãäåæ|Ölçè ¡˜éêŠ impellers of fans for mines, copper ring devices
—tœëÚۻ얉áíkjåæ˜îÄï for inhibiting spark energy are added to prevent
deformation from being occurred during high
ð˜ÌqrsÚÛñÒÓÔòó’ speed running of impellers and spark from being
2.5.{|ôõmö÷øԘ~‰yù¬­ú
2.5 There are various performances and
complete specifications in the Company. The
û¬­ülqrýþ¿ÿ”lrs ®†˜· fans matching with ventilation networks of

¸RœšÚے
various coal mines and non-coal mines are
available for selection, and long-term high
2.6.qrs Ýr˜ rÖ ¤ žr efficient operation could be guaranteed.

Öl 60% w˜  ‘lrr


2.6 Fans could reverse the air flow and the
reversal air flow could reach more than 60% of
§ l“S”±rºmrºúrs
’ž8 direct air flow. Thus the "S" type air channel,

¬ ˜~ müâ•l  reversal air channel and fan room of traditional


air cave outlet could be saved. The fans are
¸’ especially suitable for places with small site area,
surface subsidence and landslide dangers.
2.7  !"#$%&'() 2.7 The main parts of fans use steel plate and
*+, $-%&'()./0123 section steel installation and welding structure.
Blades are in hollow steel plate welding structure,
2.8 456379:;<45=>?@A thus strength of blades and overall strength is

BCD<EF'GHIJKL<EF'MN
high.
2.8 Low noise. Noise of various series of fans
O5PGQSTPUSTVBWXY5.O could reach requirement of Chinese standards.
Besides, in accordance with the requirements of
5Z['\]^_6453 users, mufflers are made and sound arresters and
silencers are added in diffusers and diffusion
3`FBCDZ abcdefghijklm towers to lower the noise in a further way.

nop 3. FBCDZ series explosion-proof draw-out


counter-rotating axial-flow fans for mines
3.1 qrs 3.1 Overview
t9:;*uvwxyE;' This series of fans are counter-rotating
explosion-proof main fans. The primary and
;<]!z{(|}~€Z>‚ secondary blades of fans use three-dimensional
<ƒ„…†()'‡ˆ!‰2'H‡ twisted blades with adjustable incidence angles

‰>Š‚‹'‡Œ Ž‘’“–—“˜™š›œ’’’
respectively. The air volume is large, air pressure
is high and air volume and air pressure are
“–—“˜™Ÿ‰Œ ¡¢£›’’¡¤š¥¦¥’¡¤¨©ª adjustable.AirvolumescopeisQ=720m³/min-4800

ˆ!+"«­<;3 0 m³/min and static pressure


scope is Pst=400Pa-5950Pa, applicable to
®¯9: ›’°±²!¥›³´µ!¶’³·µ the ventilation of large and medium coal mines.
ƒ¹|º»'¼ ›½ ³¾›œ’ ¿—“˜™µ !¶½ This series of fans adopt three kinds of hub ratios,

³¦œ’¿—“˜™µ !œ½³›’¿—“˜™µ !¾’½³¥œ’¿—“˜™µ ! including 40(A), 54(B) and 60(C), and motors
adopt five kinds of rotating speeds, including 4
¾‘½³›¦’¿—“˜™µ À¹ÁÂ3 poles (1480 r/min), 6 poles (980 r/min), 8 poles
(740 r/min), 10 poles (580 r/min) and 12 poles
(490 r/min).

3.2 opÃÄÅÆÇÈ Explanation of markings of fan type


F B C D Z – a –№ × / 2 ×N
ÉʼËÌÍ Auxiliary motor power (kw)
ÎÏ (ÐÑÒÓÔÕÖ×) Machine No. (Decimeter of blade diameter)
¼Ë½Ø Number of pole of motor
E Main
uv Counter-rotating
ÙÚw Draw out
xy Explosion-proof
 Fan
3.3 FBCDZ ÛÜÝÞßàáâãäåæçèéêëìíîïðñ
Technical performance parameter table of FBCDZ series explosion-proof
draw-out counter-rotating axial flow fans for mines

òó ôõö ÷øùúûü ýþ ÿ ÿ (pa)


kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
FBCDZ№13
B YBF2-225M-4 2 x 45 17-32 3350-1550
n=1450r/min
B YBF2-200L2-6 2 x 22 15-30 1750-400
FBCDZ№13
B YBF2-225M-6 2 x 30 15.2-33.7 1750-463
n=980r/min
B YBF2-250M-6 2 x 37 16.8-36 1820-480
FBCDZ№14 B YBF2-250M-6 2 x 37 18.5-40 2000-520
n=980r/min B YBF2-280S-6 2 x 45 18.9-42.1 2029-537
B YBF2-250M-6 2 x 37 18-44 2140-950
FBCDZ№15
B YBF2-280S-6 2 x 45 17.2-41.5 2146-437
n=980r/min
B YBF2-280M-6 2 x 55 23.3-51.7 2340-617
B YBF2-280S-6 2 x 45 28-54.5 2245-690
FBCDZ№16
B YBF2-280M-6 2 x 55 28-58.9 2450-700
n=980r/min
B YBF2-315S-6 2 x 75 28.3-62.8 2650-702
B YBF2-315S-6 2 x 75 33-68.2 2793-750
FBCDZ№17
B YBF2-315M-6 2 x 90 33-70.8 2900-780
n=980r/min
B YBF2-315L1-6 2 x 110 33.9-75.3 2992-792
B YBF2-315S-6 2 x 75 36-78.2 3075-840
B YBF2-315M-6 2 x 90 36.8-80.4 3192-850
FBCDZ№18
B YBF2-315L1-6 2 x 110 39-85.1 3280-875
n=980r/min
B YBF2-315L2-6 2 x 132 40.2-89.4 3354-888
B YBF2-355S-6 2 x 160 42.1-90.5 3420-900
FBCDZ№18
B YBF2-315S-8 2 x55 24-60 1800-720
n=740r/min
B YBF2-315L1-6 2 x 110 36.5-90 3400-600
B YBF2-315L2-6 2 x 132 36.5-95 3430-600
B YBF2-355S-6 2 x 160 36.5-98 3650-600
FBCDZ№19
B YBF2-355M1-6 2 x 185 36.5-100 3700-600
n=980r/min
B YBF2-355M2-6 2 x 200 36.5-105 3710-600
B YBF2-355L1-6 2 x 220 36.5-108 3750-600
B YBF2-355L2-6 2 x 250 36.5-110 3800-600
FBCDZ№19
B YBF2-315S-8 2 x55 28-80 2000-780
n=740r/min
  
 (pa)
kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
FBCDZ№19 B YBF2-315M-8 2 x75 28-85 2050-780
n=740r/min B YBF2-315L1-8 2 x90 28-87 2100-780
B YBF2-355S-6 2 x160 48.2-100 3700-639
B YBF2-355M1-6 2 x185 48.2-102.5 3710-639
FBCDZ№20
B YBF2-355M2-6 2 x200 48.2-105.4 3730-639
n=980r/min
B YBF2-355L1-6 2 x220 48.2-107.4 3750-639
B YBF2-355L2-6 2 x250 48.2-114.3 3760-639
B YBF2-315M-8 2 x75 36-85 2250-950
FBCDZ№20 B YBF2-315L1-8 2 x90 36-88 2300-950
n=740r/min B YBF2-315L2-8 2 x110 36-90 2340-950
B YBF2-355S-8 2 x132 36-96 2350-950
B YBF2-355M1-6 2 x185 55-122 4000-1000
B YBF2-355M2-6 2 x200 58-126 4050-1000
FBCDZ№21
B YBF2-355L1-6 2 x220 58-128 4100-1000
n=980r/min
B YBF2-355L2-6 2 x250 58-136 4150-1000
B YBF2-450S2-6 2 x280 58-140 4150-1000
B YBF2-315L1-8 2 x90 41.9-76.5 2280-402
FBCDZ№21 B YBF2-315L2-8 2 x110 41.9-85.2 2550-402
n=740r/min B YBF2-355S-8 2 x132 41.9-94 2600-402
B YBF2-355S2-8 2 x160 41.9-107 2580-402
B YBF2-355M2-6 2 x200 65-90 4250-1620
B YBF2-355L1-6 2 x220 65-108 4300-1620
FBCDZ№22 B YBF2-355L2-6 2 x250 65-122 4350-1620
n=980r/min B YBF2-450S2-6 2 x280 65-135 4400-1620
B YBF2-450S3-6 2 x315 65-140 4450-1620
B YBF2-450S2-6 2 x355 65-150 4500-1620
B YBF2-315L2-8 2 x110 48.4-95 2550-441
FBCDZ№22 B YBF2-355S-8 2 x132 48.4-98.2 2650-441
n=740r/min B YBF2-355S2-8 2 x160 48.4-101.9 2586-441
B YBF2-355M-8 2 x185 48.4-110 2590-441
B YBF2-315L1-8 2 x90 54-78 2300-1220
B YBF2-315L2-8 2 x110 54-85 2600-1200
FBCDZ№23 B YBF2-355S-8 2 x132 54-90 2800-1220
n=740r/min B YBF2-355S2-8 2 x160 54-108 3600-1040
B YBF2-355M-8 2 x185 54-117 3000-1220
B YBF-450S1-8 2 x200 54-125 3080-1220
     !(pa)
kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
B YBF-450S2-8 2 x220 56-125 3700-1040
B YBF-450S3-8 2 x250 58-125 3860-1040
FBCDZ№23
B YBF-450M1-8 2 x280 58-130 3100-1220
n=740r/min
B YBF-450M2-8 2 x 315 58-135 3150-1220
B YBF-560S2-8 2 x 355 58-140 3200-1220
B YBF-400M1-8
2 x160 65-123 2900-1330
B YBF2-355S2-8
B YBF-400M2-8
FBCDZ№24 2 x185 65-128 2960-1330
B YBF2-355M-8
n=740r/min
B YBF-450S1-8
2 x200 65-133 3000-1330
B YBF2-355L2-8
B YBF-450S2-8 2 x220 65-134 3078-1330
B YBF2-400S2-8 2 x220 65-134 3078-1330
B YBF-450S3-8
2 x250 65-136.5 3080-1330
FBCDZ№24 B YBF2-400S3-8
n=740r/min B YBF-450M1-8 2 x280 65-142 3200-1330
B YBF-450M2-8 2 x315 65-145 3250-1330
B YBF-560S2-8 2 x355 65-150 3300-1330
B YBF2-355S-10 2"90 44-105 820-2000
2"110
FBCDZ№24
B YBF2-355M1-10 44-112 820-2050
2"132
n=580r/min
B YBF2-355M2-10 44-116 820-2080
B YBF450S2-8 2 x220 53-85 1230-3700
B YBF450S3 -8 2 x250 53-95 1230-4000
FBCDZ№25
B YBF450M1-8 2 x280 53-113 1230-4250
n=740r/min
B YBF450M2-8 2 x315 53-130 1230-4300
B YBF560S2-8 2 x355 53-144 1230-4400
B YBF2-355M1-10 "
2 110 42-85 760-2500
B YBF400M2-10 2"132 42-90 760-2600
2"160
FBCDZ№25
B YBF450S1-10 42-100 760-2700
2"185
n=580r/min
B YBF450S2-10 42-112 760-2770
B YBF450S3-10 2"200 42-122 760-2790
B YBF450M1-8 2 x280 60-110 1340-4400
FBCDZ№26 B YBF450M2-8 2 x315 60-128 1340-4600
n=740r/min B YBF560S2-8 2 x355 60-143 1340-4760
B YBF560M1-8 2 x400 60-160 1340-4900
#$ %&' ()*+,- ./ 01 02(pa)
kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
FBCDZ№26
B YBF560M2-8 2 x450 60-175 1340-4910
n=740r/min
B YBF450S1-10 23160 55-86 820-2860
B YBF450S2-10 23185 55-96 820-2800
23200
FBCDZ№26
B YBF450S3-10 55-112 820-2850
23220
n=580r/min
B YBF450M1-10 55-128 820-2900
B YBF450M2-10 23250 55-137 820-2950
B YBF560S2-8
2×355 67-100 1440-4250
B YBF630S1-8
B YBF560M1-8
2×400 67-120 1440-4650
B YBF630S2-8
FBCDZ№27 B YBF560M2-8
2×450 67-140 1440-4850
n=740r/min B YBF630M1-8
B YBF630S1-8
2×500 67-160 1440-5050
B YBF630M2-8
B YBF630S2-8
2×560 67-175 1440-5250
B YBF710S1-8
B
B
YBF450S1-10
YBF560S1-10
23160 53-90 890-2700

23185
B YBF450S2-10
53-100 890-2800
B YBF560S2-10

23200
B YBF450S3-10
53-105 890-2900
B YBF560M1-10

23220
FBCDZ№27 B YBF450M1-10
53-110 890-2950
n=580r/min B YBF560M2-10

23250
B YBF450M2-10
53-130 890-3150
B YBF630S1-10

23280
B YBF560S2-10
53-140 890-3200
B YBF630S1-10

23315
B YBF560M1-10
53-154 890-3250
B YBF630M1-10
B YBF560M1-8
2×400 75-119 1550-4650
FBCDZ№28 B YBF630S2-8
n=740r/min B YBF560M2-8
2×450 75-140 1550-5000
B YBF630M1-8
45 678 9:;<=> ?@ AB AC(pa)
kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
B YBF630S1-8
2×500 75-165 1550-5300
B YBF630M2-8
FBCDZ№28 B YBF630S2-8
2×560 75-179 1550-5600
n=740r/min B YBF710S1-8
B YBF630M1-8
2×630 75-198 1550-5650
B YBF710S2-8
B
B
YBF450S1-10
YBF560S1-10
2D160 59-93 950-2800

2D185
B YBF450S2-10
59-98 950-2900
B YBF560S2-10

2D200
B YBF450S3-10
59-105 950-2950
B YBF560M1-10

2D220
B YBF450M1-10
59-110 950-3000
FBCDZ№28 B YBF560M2-10

2D250
n=580r/min B YBF450M2-10
59-130 950-3350
B YBF630S1-10

2D280
B YBF560S2-10
59-140 950-3400
B YBF630S2-10

2D315
B YBF560M1-10
59-160 950-3450
B YBF630M1-10

2D355
B YBF560M2-10
59-171 950-3500
B YBF630M2-10
B YBF560M1-8
2×400 83-130 1650-4950
B YBF630S2-8
B YBF560M2-8
2×450 83-154 1650-5350
B YBF630M1-8
FBCDZ№29 B YBF630S1-8
2×500 83-181 1650-5650
n=740r/min B YBF630M2-8
B YBF630S2-8
2×560 83-196 1650-5950
B YBF710S1-8
B YBF630M1-8
2×630 83-218 1650-6050
B YBF710S2-8

FBCDZ№29
B
B
YBF450S1-10
YBF560S1-10
2D160 65-95 1020-3000

2D185
n=580r/min
B YBF450S2-10 65-100 1020-3050
EF GHI JKLMNO PQ RS RT(pa)
kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
B YBF560S2-10 2U185 65-100 1020-3050

2U200
B YBF450S3-10
65-108 1020-3100
B YBF560M1-10

2U220
B YBF450M1-10
65-112 1020-3100
B YBF560M2-10

2U250
B YBF450M2-10
FBCDZ№29 65-115 1020-3150
B YBF630S1-10
n=580r/min
2U280
B YBF560S2-10
65-118 1020-3200
B YBF630S2-10

2U315
B YBF560M1-10
65-138 1020-3350
B YBF630M1-10

2U355
B YBF560M2-10
65-159 1020-3450
B YBF630M2-10
B YBF630S2-8
2×560 91-216 1760-6350
B YBF710S1-8
FBCDZ№30 B YBF630M1-8
2×630 91-240 1760-6450
n=740r/min B YBF710S2-8
B YBF630M2-8
2×710 91-264 1760-6500
B YBF710S3-8
B
B
YBF450M1-10
YBF560M2-10
2U220 72-100 1100-3050

2U250
B YBF450M2-10
72-105 1100-3150
B YBF630S1-10

2U280
B YBF560S2-10
72-110 1100-3300
B YBF630S1-10

2U315
B YBF560M1-10
72-130 1100-3500
FBCDZ№30 B YBF630M1-10

2U355
n=580r/min B YBF560M2-10
72-151 1100-3750
B YBF630M2-10

2U400
B YBF630S1-10
72-170 1100-3900
B YBF710S1-10

2U450
B YBF630S2-10
72-190 1100-4000
B YBF710S2-10

2U500
B YBF630M1-10
72-210 1100-4010
B YBF710M1-10
VW XYZ [\]^_` ab cd ce(pa)
kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
B YBF630M1-8
2×630 92-260 1800-6450
B YBF710S2-8
B YBF630M2-8
2×710 92-266 1800-6500
FBCDZ№31 B YBF710S3-8
n=740r/min B YBF710S1-8
2×800 92-270 1800-6550
B YBF710M1-8
B YBF710S2-8
2×900 92-280 1800-6700
B YBF710M2-8
B
B
YBF560S2-10
YBF630S2-10
2f280 80-150 1170-3750

2f315
B YBF560M1-10
80-165 1170-3850
B YBF630M1-10

2f355
B YBF560M2-10
80-175 1170-3950
B YBF630M2-10

2f400
FBCDZ№31 B YBF630S1-10
80-185 1170-4100
n=580r/min B YBF710S1-10

2f450
B YBF630S2-10
80-196 1170-4200
B YBF710S2-10

2f500
B YBF630M1-10
80-218 1170-4270
B YBF710M1-10

2f560
B YBF630M2-10
80-230 1170-4270
B YBF710M2-10
B YBF630M1-8
2×630 140-450 1950-5300
B YBF710S2-8
B YBF630M2-8
2×710 140-460 1950-5400
B YBF710S3-8
FBCDZ№32 B YBF710S1-8
2×800 140-465 1950-5500
n=740r/min B YBF710M1-8
B YBF710S2-8
2×900 140-470 1950-5600
B YBF710M2-8
B YBF710M1-8
2×1000 140-480 1950-5800
B YBF800M1-8

FBCDZ№32
B
B
YBF560S2-10
YBF630S2-10
2f280 88-130 1360-3800

2f315
n=580r/min B YBF560M1-10
88-160 1360-3850
B YBF630M1-10
gh ijk lmnopq rs tu tv(pa)
kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
B
B
YBF560M2-10
YBF630M2-10
2 w355 88-180 1360-3900

2w400
B YBF630S1-10
88-185 1360-4000
B YBF710S1-10

2w450
FBCDZ№32 B YBF630S2-10
88-200 1360-4050
n=580r/min B YBF710S2-10

2w500
B YBF630M1-10
88-210 1360-4100
B YBF710M1-10

2w560
B YBF630M2-10
88-235 1360-4200
B YBF710M2-10
A YBF800S1-8 2w1120 193-448 6329-1770
2w1600
FBCDZ№33
B YBF800M2-8 134-431 8519-3063
2w1250
n=740r/min
C YBF800S2-8 109-294 8914-2377
A YBF630S2-10 2w400 94-306 2860-520
A YBF710S2-10 2w630 137-335 4052-1112
2w560
FBCDZ№33
B YBF710S1-10 152-351 3888-1087
2w800
n=580r/min
B YBF710M2-10 105-338 5233-1881
C YBF710S2-10 2w630 85-231 5476-1460
A YBF630M2-12 2w400 116-283 2885-794
FBCDZ№33 B YBF630M1-12 2w355 128- 296 2775-766
n=470r/min B YBF710S1-12 2w450 89-286 3735-1343
C YBF630M1-12 2w355 72-195 3908-1042
A YBF800M1-8 2w1400 211-490 6718-1897
2w1800
FBCDZ№34
B YBF900S1-8 147-472 9043-3252
2w1400
n=740r/min
C YBF800M1-8 119-322 9462-2523
A YBF630M1-10 2w450 102-326 3037-554
A YBF710M2-10 2w800 150-367 4291-1181
2w630
FBCDZ№34
B YBF710S2-10 166-384 4127-1154
2w900
n=580r/min
B YBF800S1-10 115-370 5555-1998
C YBF710M1-10 2w710 93-252 5813-1550
A YBF710S1-12 2w450 127-321 3062-843
2w400
FBCDZ№34
B YBF630M2-12 140-324 2946-824
2w560
n=470r/min
B YBF710M1-12 97-313 3965-1426
xy z{| }~€‚ ƒ„ …† …‡(pa)
kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
FBCDZ№34
n=470r/min
C YBF710S1-12 2 ˆ450 79-213 4149-1106

A YBF630M2-10 2ˆ500 112-366 3218-590


A YBF800S1-10 2ˆ900 164-400 4547-1251
2ˆ800
FBCDZ№35
B YBF710M2-10 181-419 4373-1223
2ˆ1000
n=580r/min
B YBF800S2-10 125-403 5887-2116
C YBF710M2-10 2ˆ800 102-275 6160-1643
A YBF710M1-12 2ˆ560 138-338 3245-893
FBCDZ№35 B YBF710S1-12 2ˆ450 153-353 3121-873
n=470r/min B YBF710M2-12 2ˆ630 106-341 4201-1511
C YBF710S2-12 2ˆ500 86-232 4396-1172
A YBF710S1-10 2ˆ560 129-398 3405-620
A YBF800S1-10 2ˆ1000 178-436 4810-1324
2ˆ900
FBCDZ№36
B YBF800S1-10 197-456 4621-1294
2ˆ1250
n=580r/min
B YBF800M2-10 137-439 6228-2239
C YBF710M2-10 2ˆ800 111-299 6517-1738
A YBF710M2-12 2ˆ630 151-368 3433-945
FBCDZ№36 B YBF710M1-12 2ˆ560 167-385 3302-924
n=470r/min B YBF800S1-12 2ˆ710 115-371 4445-1598
C YBF710M1-12 2ˆ560 93-253 4651-1240
A YBF800M1-10 2ˆ1120 194-473 4865-1399
FBCDZ№37 B YBF800S2-10 2ˆ1000 214-495 4888-1367
n=580r/min B YBF900S1-10 2ˆ1400 148-477 6573-2365
C YBF800M1-10 2ˆ1120 120-325 6884-1836
A YBF800S1-12 2ˆ710 163-400 3627-998
FBCDZ№37 B YBF710M2-12 2ˆ630 181-418 3448-975
n=470r/min B YBF800S2-12 2ˆ800 125-403 4695-1688
C YBF710M2-12 2ˆ630 101-275 4913-1310
A YBF900S1-10 2ˆ1400 210-513 5360-1475
FBCDZ№38 B YBF800M1-10 2ˆ1120 231-536 5155-1442
n=580r/min B YBF900S2-10 2ˆ1600 161-517 6940-2495
C YBF800M2-10 2ˆ1250 130-352 7261-1936
‰Š ‹Œ Ž‘’“ ”• –— –˜(pa)
kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
A YBF800S2-12 2 ™800 177-433 3825-1053
FBCDZ№38 B YBF800S1-12 2™710 195-453 3679-1029
n=470r/min B YBF800M2-12 2™1000 136-437 4953-1781
C YBF800S1-12 2™710 110-297 5182-1382
A YBF900S2-10 2™1600 227-554 5646-1554
FBCDZ№39 B YBF800M2-10 2™1250 250-579 5430-1518
n=580r/min B YBF900M1-10 2™1800 173-558 7309-2628
C YBF900S1-10 2™1400 141-381 7648-2039
A YBF800M1-12 2™900 191-468 4029-1109
FBCDZ№39 B YBF800S2-12 2™800 211-489 3876-1084
n=470r/min B YBF900S1-12 2™1120 147-472 5217-1876
C YBF800M1-12 2™900 119-322 5459-1456
A YBF900M1-10 2™1800 244-598 5939-1634
FBCDZ№40 B YBF900S2-10 2™1600 270-625 5712-1597
n=580r/min B YBF900M2-10 2™2000 187-603 7689-2765
C YBF900S2-10 2™1600 152-411 8045-2145
A YBF800M2-12 2™1000 206-505 4239-1166
FBCDZ№40 B YBF800M1-12 2™900 228-528 4077-1140
n=470r/min B YBF900S2-12 2™1250 158-509 5488-1973
C YBF800M2-12 2™1000 128-347 5742-1531

2™1600
FBCDZ№41
B YBF900S2-10 292-673 6002-1678
n=580r/min
A YBF900S1-12 2™1120 222-544 4453-1225
FBCDZ№41 B YBF800M2-12 2™1000 246-569 4283-1198
n=470r/min B YBF900M1-12 2™1400 170-548 5765-2073
C YBF900S1-12 2™1120 138-374 6033-1609

2™1800
FBCDZ№42
C YBF900M1-10 314-723 6298-1761
n=580r/min
A YBF900M1-12 2™1400 239-585 4673-1286
FBCDZ№42 B YBF900S1-12 2™1120 264-611 4495-1257
n=470r/min B YBF900M2-12 2™1600 183-589 6051-2176
C YBF900S2-12 2™1250 148-402 6331-1688
š› œž Ÿ ¡¢£¤ ¥¦ §¨ §©(pa)
kinds of hub Model of Power Air volume Air pressure
Series
ratios auxiliary motor (kw) (m3/s) (pa)
FBCDZ№43
n=580r/min
C ª2000 336-776
YBF900M-10 2 6601-1846

A YBF900M2-12 2ª1600 257-628 4898-1348


FBCDZ№43 B YBF900S2-12 2ª1250 283-656 4711-1317
n=470r/min B YBF900M-12 2ª1800 196-632 6342-2280
C YBF900M1-12 2ª1400 159-431 6636-1770
A YBF900M2-12 2ª1600 275-672 5129-1411
FBCDZ№44 B YBF900M1-12 2ª1400 303-703 4933-1379
n=470r/min B YBF900M-12 2ª2000 211-678 6640-2388
C YBF900M2-12 2ª1600 171-462 6948-1853
A YBF900M-12 2ª1800 294-719 5365-1476
FBCDZ№45 B YBF900M2-12 2ª1600 325-752 5160-1443
n=470r/min B YBF900M-12 2ª2200 225-725 6954-2497
C YBF900M-12 2ª1800 182-494 7267-1938
A YBF900M-12 2ª2000 314-768 5606-1543
FBCDZ№46 B YBF900M-12 2ª1800 347-803 5392-1508
n=470r/min B YBF900M-12 2ª2500 241-774 7258-2610
C YBF900M-12 2ª2000 195-528 7594-2025
3.4 FBCDZ «¬­®¯°±²³´µ¶·¸¹º»¼½¾¿ÀÁÂ
Schematic diagram of outline structure of FBCDZ series explosion-proof
draw-out counter-rotating axial flow fans for mines
1.ÃÄÅ Current collector 2.ÆÄÇ Diversion device
3.ÈÉÊ¢ Primary main machine 4.ÈÉ¡¢ Primary motor
5.Èɘ Primary blade 6.Ìɘ Secondary blade
7.ÌÉ¡¢ Secondary motor 8.ÌÉÊ¢ Secondary main machine
9.ÍÎÅ Diffuser 10.ÏÐÑ Changeable diameter joint
11.ÒÓÅ Muffler 12.ÍÎÔ Diffusion tower
3.5 FBCDZ ÕÖ×ØÙÚÛÜÝÞßàáâãäåæçèéê
Outline dimension table of FBCDZ series explosion-proof draw-out
counter-rotating axial flow fans for mines
ëì íîïð Outline dimension
Type φ D L0 L L1 L2 L3 L4 L5 L6 B B1 H H1 h h1
№12 1452 1200 10000 8540 420 970 1800 720 1260 2400 1020 1672 1886 1010 200 100
№13 1573 1300 10000 9245 455 1100 1950 780 1260 2600 1110 1793 2017 1070 200 100
№14 1694 1400 12000 9980 490 1150 2100 840 1500 2800 1190 1914 2147 1130 200 100
№15 1815 1500 13000 10907 525 1260 2250 900 1500 3075 1280 2035 2278 1190 200 100
№16 1936 1600 13000 11152 560 1260 2400 960 1500 3212 1360 2156 2438 1280 200 100
№17 2057 1700 14000 11455 595 1600 2550 1020 2000 3400 1450 2277 2569 1340 250 120
№18 2178 1800 14000 11540 630 1730 2700 1080 2000 3690 1530 2398 2709 1400 250 120
№19 2299 1900 15000 12330 665 1780 2850 1140 2000 3895 1620 2519 2830 1460 250 120
№20 2420 2000 15000 13100 700 2100 3000 1200 2000 4100 1700 2640 3120 1520 250 120
№21 2541 2100 17000 14595 735 2200 3570 1260 2000 4830 1790 2761 3268 1590 250 120
№22 2662 2200 18000 15590 770 2200 3740 1320 2500 5060 1870 2922 3427 1670 250 120
№23 2783 2300 18000 16085 805 2200 3910 1380 2500 5290 1960 3043 3886 1850 300 140
№24 2904 2400 20000 17080 840 2700 4080 1440 2500 5520 2040 3164 3824 1910 300 140
№25 3025 2500 20000 17650 875 2775 4250 1500 2500 5750 2130 3285 3963 1970 300 140
№26 3146 2600 24000 20970 910 2800 4420 1560 2500 5980 2210 3406 4104 2030 300 140
№27 3267 2700 24000 21665 945 2900 4590 1620 2500 6210 2300 3527 4240 2090 300 140
№28 3388 2800 26000 22030 980 2950 4760 1680 2500 6440 2380 3648 4378 2150 300 140
№29 3509 2900 26000 22755 1015 2950 4930 1740 2500 6670 2470 3809 4537 2230 350 160
№30 3630 3000 28000 23750 1050 2950 6000 1800 2500 6900 2550 3930 4675 2290 350 160
№31 3751 3100 28000 24575 1085 3000 6200 1860 2500 7130 2640 4051 4814 2350 350 160
№32 3872 3200 30000 25500 1120 3100 6400 1920 2500 7360 2720 4172 4952 2410 350 160
№33 3993 3300 30000 26125 1155 3150 6600 1980 2500 7590 2810 4293 5091 2470 350 160
№34 4114 3400 32000 26940 1190 3180 6800 2040 2500 7820 2890 4414 5229 2530 350 160
№35 4235 3500 34000 27875 1225 3500 7000 2100 2500 8050 2980 4535 5368 2590 400 200
№36 4356 3600 34000 28600 1360 3600 7200 2160 2500 8280 3060 4656 5386 2650 400 200
№37 4477 3700 36000 29225 1395 3650 7400 2220 2500 8510 3150 4777 5645 2710 400 200
№38 4598 3800 36000 29850 1330 3700 7600 2280 2500 8740 3230 4898 5783 2770 400 200
№39 4719 3900 36000 30975 1365 3750 7800 2340 3000 8970 3320 5180 6002 2880 450 250
№40 4840 4000 36000 31270 1400 3750 8000 2400 3000 9200 3400 5300 6240 2900 450 250
№41 4961 4100 38000 32125 1435 3800 8200 2460 3000 9430 3490 5420 6428 3100 450 250
№42 5082 4200 38000 32650 1470 3800 8400 2520 3000 9660 3570 5550 6631 3220 450 250
№43 5203 4300 40000 33275 1505 3850 8600 2580 3000 9890 3600 5680 6834 3340 500 300
№44 5324 4400 40000 34240 1540 3850 9240 2640 3000 10120 3740 5840 7052 3460 500 300
№45 5445 4500 42000 34875 1575 3900 9450 2700 3000 10350 3830 5980 7260 3580 500 300
№46 5566 4600 44000 36410 1610 3900 9660 2760 4000 10580 3910 6100 7458 3700 500 300
4ñFBD òóôõö÷øùúûüýþ 4. FBD series explosion-proof press-in
ÿ counter-rotating axial flow local fans

4.1 Overview
4.1  FBDseriesexplosion-proofpress-incounter-rotatin

FBD 

g axial flow local fans are mainly used under
mine shafts and the places containing gas, coal
 !"#$%&' dust or inflammable gas of other industrial

()*+,-./0123('45' shaft building and tunnel long-distance


departments, and can be used for mine tunneling,

67.89':;<= ventilation of coal mines, metal mines, chemical

>?@.ABCDEFGHIJ places where medium temperature is less than


mines and other mines. The fans are applicable to

40 K and humidity is less than 95%±3% (at


40K1LGHM 95%±3% (25KN) OPQ
25K) and without corrosion.
./0B
4.2  RSTUVW
Explanation of markings of fan type

F B D – a –№ × / 2 × N

XYZ[\] Auxiliary motor power(kw)


^ (_`ab.cde)
Z[fe Number of poles of motor
Machine No. (Decimeter of blade diameter)


Counter-rotating
g Explosion-proof
 Fan
4.3 FBD hijklmnopqrstuvwxyz{|}~
Technical performance parameters table of FBD series explosion-proof press-in
counter-rotating axial flow local fans for mines

€ ‚ƒ€ „… †‡ †ˆ ‰Š Noise
Machine Power Air volume Air pressure
Model of motor dB(cas)
№ (kw) (m3/s) (pa)
YBF2-132S1-2 2x5.5 60-210 2600-600
5.0 ≤30
YBF2-132S2-2 2x7.5 120-285 3450-400
YBF2-160M1-2 2x11 170-370 4300-800
YBF2-160M2-2 2x15 200-450 4500-800
6.0
YBF2-160L-2 2x18.5 300-540 5100-800
YBF2-180M-2 2x22 360-550 4950-850
6.3 YBF2-200L1-2 2x30 380-600 5600-900
6.7 YBF2-200L2-2 2x37 400-720 6800-900
7.1 YBF2-225M-2 2x45 420-850 7560-1000
8.0 YBF2-250M-2 2x55 540-850 7800-1100 ≤25
8.5 YBF2-280S-2 2x75 550-1000 9500-1500
YBF2-200L-4 2x30 660-1320 3200-500
9.5
YBF2-225S-4 2x37 690-1400 3300-530
YBF2-225S-4 2x37 720-1500 3500-550
10.0
YBF2-225M-4 2x45 800-1520 3700-580
YBF2-250M-4 2x55 960-1980 4150-624
11.0
YBF2-280S-4 2x75 1080-2220 4400-650
4.4 FBD hijklmnopqrstuvw‹ŒŽ‘~
Schematic diagram of outline structure of FBD series explosion-proof press-in
counter-rotating axial flow local fans for mines

1.’“” Muffler 2.‚ Motor


3. •–— Secondary main machine 4.˜™ Impeller
5.š–— Primary main machine 6.›œ” Current collector
4.5 FBD žŸ ¡¢£¤¥¦§¨©ª«¬­®¯°±²
Outline dimension table of FBD series explosion-proof press-in counter-rotating
axial flow local fans for mines
³´ µ¶ ·¸¹º Outline dimension
Type Power
φ1 φ2 φ3 φ4 H h A B L
№ (kw)
2x5.5
5.0 640 570 503 535 925 400 480 700 1980
2x7.5
2x11
2x15 760 2180
6.0 730 670 603 630 1025 435 580
2x18.5
2x22 800 2200
6.3 2x30 765 705 635 665 1110 465 620 900 2620
6.7 2x37 820 742 675 715 1150 485 580 900 2740
7.1 2x45 885 798 715 750 1260 525 680 1000 2750
8.0 2x55 976 890 805 835 1305 720 780 1100 3350
8.5 2x75 1025 945 855 890 1400 745 780 1200 3600
2x30 1450 3700
9.5 1125 1050 956 985 650 780 1000
2x37 1500 3860
2x37 3860
10.0 1175 1095 1006 1035 1530 655 780 1000
2x45 4090
2x55 4700
11.0 1280 1195 1106 1180 1725 718 880 1100
2x75 4930
5»¼½¾¿ 5. Introduction of parts
ÀÁÂ
5.1 Diffuser
5.1 In serving as major fans and fans of machine
ÃÄÅÆÇÈÉÊËÌÍÎÏÐÊËÌ stations, all series of energy-saving fans for

ÑÌÒËÌÓÔÕÖ×ØÙÚÍÛÜÇÝÞ
mining use shall be equipped with the dedicated
diffuser made of steel plates. The diffusers of

ßàáâÏÐÊËÌãÖ×ÝÞßäåæçè
major ground fans can transform partial dynamic
pressure into static pressure so as to reduce the
éêëÎìéÔíîïðèéñòÔóôìé loss of outlet dynamic pressure, improve the

õöÔ÷øùÈÉÛúÛàûüÆýþÿ9
efficiency of static pressure, and realize the
purpose of saving energy. The fans installed

ÛËÌÕÖ×ÝÞßÔ@äíîÄÔD
underground for metal mines shall be equipped
with diffusers, which can not only reduce partial
äíîÝÞßïðÛèé"ÔFäí resistance coefficient, but also lower the outlet

îËÌþ,ÛæÔÈ ÊË
à
dynamic pressure value, and thus substantially
reducing the partial resistance of fans, and

ÃÄÅÊËÌ ÜÇÖÛÝÞßàÝ
cutting down power consumption for
ventilation.
ÞßÛËÌïðÇà All series of fans are equipped with dedicated

5.2 Â
diffusers, flanges of which are connected with
outlet flanges of fans with bolts.

ZÛÃÄÅÊËÌÛ A `
5.2 Muffler
Various series of A-weighted sound level fans
b !#$%Û&'Ôl(ÍÎÏÐÊË manufactured by the Company conform to the

ÌýþÿáâÓÔn)Û*+-Éøù.
stipulation of coal industry standard. However,
when it is used as the main fan installed on

t*+$%Ôu/01234Û5Í67à
ground, in case the noise produced by it cannot
reach environmental noise standard, it will affect
8ԁ ýþÏÊËÌÛá :;34<=> the work and rest of surrounding residents. Thus,

ÓÔՁ?ÏÐÊËÌÝÞßAýþB+ßÔ
in case the place installing main fan is near to
residential area, a muffler shall be installed

Š?ÝÞCEGHB+IJԑÏÊËÌ*+
behind the diffuser of main fan, and noise
reduction device shall be added in diffusiontower
íù.t*+$%÷ à to reduce the noise of main fan blow

’KÎÃLæÊËÌÖ,MB+ßÔ
environmental noise standard.
The Company also provides mufflers for

÷NOæÊËÌ*+P9 5QÛRSԜ
various local fans to reduce the interference of
noise of local fans on workers under the shaft
ýTÑ5QÛUVWXà and ensure the safety production and physical

5.3 ÀÁY
health of workers.
5.3 Diffusion tower
?ÝÞßAK ‡[Ë\â]^Ý_a
Behind the diffuser, there is also an air
exhaust bending channel with air passing cross
ªcÛd˪eÔ®ªefÎÝÞCÔ(ÛÍ section gradually expanding and bending

LJgâNOÊËÌÛèéñòÔóôÊËÌ
upwards. This bending channel is called diffusion
tower. On the one hand, its function is to reduce

Û õìé±²‡gâhåiËdjakԜ
the dynamic pressure loss of fans and improve
the effective static pressure of fans; on the other
·12.tÔKä÷íî*`Ô÷mRS34 hand, it could discharge ventilation air methane

Ûop67àZÛØÙqÝÞCÔ
to the sky, protect surrounding environment and
lower noise to avoid the interference on sleeping

‘rq 90°ÛÝÞCsÎ 45°¾vwxÝÞCÔ


and resting of residents. The steel plate diffusion
tower manufactured by the Company changes
íîMÝÞCÛæÔÈÉõyzç Soviet-style 90° diffusion tower to 45° or

Ä{à
streamline diffusion tower, which greatly reduces
partial resistance of diffusion tower and has an
obvious energy saving effect.
5.4 |}|~€‚ƒ („…) 5.4 Self-opening and self-closing air
door (butterfly valve)
†ˆ‰‹ŒŽ“‹”•–—˜™š shaft are Main fans needed by coal mine ventilation
two, one for working and the other one
˜›ž™š˜ŸŽ™ ¡˜“‹”¢£ provided with Thus,
for standby. each main fan must be

¤¥Ÿš¦‹§¨—˜“‹”©«›ž¬™­ in parallel, in order to successfully open each fan,


an air door. When two fans work

¯°³´µ¶¸¹¡˜‹”™º»¥Ÿ¼½¿ each fan shall be provided with an air door. The


air doors designed and made by the Company
‹§¨ÀÁÂÃÅƞ¿‹§™°Çȉ‹Œ will be installed between ventilation shaft cave
and fan current collector. After fan is started,
‹Éʋ”ËÌÍÎϨ¸¹‹”Йы” door will be opened by the air pressure of fan;
after fan is stopped, door will be closed by its
‹ÒÓ§Ô¸Õ֔Йѧ¿½×½ØÙÚ¨ own weight. The negative pressure produced by
ۚ˜‹”›žÜÝ¿ÞÒßßÓ§Ôà™á door and reduce air leak. This kind of door has
working of the other fan will tightly draw the

â㋨ä§Èåæˆçèéêë쎙íî been used by many metal mines. Comparing with


other existing air doors of coal mine, it does not
†ˆï–¿ð틧™ñòóôõöß÷ø only save hoisting equipment and has a simple
structure, but also convenient to be managed and
ùúû™üýþÿj ÷p¨ the cost is low.
6. Main auxiliary products
6
 6.1 Selection of special start cabinets of
6.1 ‚ 
fans
s Select rated workingvoltage and capacity in accordance
stÒʏ›žÒ¨ withpowergridvoltageandmainfanrequirements.
s Reasonably select electric control and
st !"#$ÿ‹”%¹ starting supply system condition Š
means of fans in accordance with power

ˆj&Š (1) In case power grid capacity allows, direct

(1)‹'(™Ž )*¹ˆÕ
starting could be selected;
(2) In case power grid capacity is relatively small,

(2)v+¬,Ž-Ò./¹ˆj&
pressure reduction or soft starting means and
variable frequency staring means could be
~0¹ˆj&Õ selected;
(3) Generally, electric control of 6KV and 10KV
(3)6KV  10KV ‹”%š1Ž)*¹ˆ fan selects direct starting method;
(4) Where fan requires speed regulation,
j&Õ electrical control with frequency converter shall

(4)‹”23¿,Ž4~0Ç5¿%¨ s For double circuit power supply, it is


be selected.

sž6789Ž:;%Ç5¨ suggested to select complete set of electrical


control device.
(1) 380V÷ 660V %Š¥&Ž GGD
(1) Electrical control of 380V and 660V main
fans: fixed type shall select GGD complete
:;Ç5Õ¦<&Ž GCK . MNS :;Ç5¨ equipment; draw out type shall select GCK or
MNS complete equipment. General configuration
š1¥5­=>÷«?¹ˆ@™¬ 7 ˜Õ is incoming line, contact and starting cabinet, 7
sets in total.
A10KV BCDEFGHIJK
(2) 6KV
(2) Electric control of 6KV and 10KV main
XGN LMNOPQRSTPUVWAXYZ fans: Fixed type shall select XGN type complete

[\]Q^ 7 _`abIJK KYN28 LMN


equipment, whose general configuration is
incoming line, contact and starting cabinet, 7 sets

OPQRSTPUVWAXYAcdAefg in total; run-out type shall select KYN28 type


complete equipment, whose general
Z[\]Q^ 11 _` configuration is incoming line, contact, phase
changing, mutual inductor and starting cabinet,
hiQkKDl]ZDm]Knoqruwx 11 sets in total.

yJz{|}
Besides, users could select to add power cabinet
and capacitor box in accordance with their own
6.2 €‚ƒ„…†‡‰
condition.
6.2 Microcomputer online monitoring
Œ‘’Q“”•–—˜™š›Zœ and early warning system

ŒŸ‘Ÿ WAŒ¡AŒ¢AŒ£A¤
During operation process of fans,
microcomputer could accurately reflect and

§ZH¨©ª«D­AD¡A®\¯°±Q² record the parameters such as operation curves,


air pressures, air volumes, air speeds, bearings,
•œ³´Zµ¶·¸Q¹•º»¼“’½ stator temperatures, electric currents, voltages
and vibrations of fans, and could record, archive
b¾¿ÀÁŸŒ‘xy}ÂÃRÄÅVŸ and make fault alarm. Besides, the fan operation

ÆÇÈÈÉ}
condition of the last three months could be
searched from microcomputer. It is a kind of
advanced high technology.
ÊËÌ ÍÎÏÐÑ Chapter II Tunnel fans

1Ò SDF(A)ÓÔÕÖ×ØÙÚÛÜÝ
1.1 Þß
1. SDF(A) special axial flow fans for

SDF (A) àáâãäáåæçáèéç


tunnel construction
1.1 Characteristics
êëìçíîïðçñòóôõö÷øù SDF (A) type fans have the characteristics of
úûüçýþÿ ÿô fast outlet air speed, large air volume, energy

) ÷
saving and easy maintenance. They are suitable
for operation of small sections such as subways,
diversion works and petroleum pipeline projects.

SDF(A) ÓÔÕÖ×ØÙÚÛÜÝ
SDF(A) special axial flow fans for tunnel construction

1.2

Explanation of markings of fan type
S D F (A) -2- №6.0
â 6.0/0 600mm
Machine number is 6.0, that is, diameter of impeller is 600mm
ðâ Number of pole of motor
7å Single rotation high speed series
áâ Fan
< Counter rotating
> Tunnel
1.3 SDF(A) !"#$%&'(*+,-.12345
Technical performance parameter table of SDF(A)special axial flow fans for
tunnel construction

6; 6= ?@ ABCDE AFGHI8DE
689: Air volume Air pressure Rotating speed
Power at the
Maximum auxiliary
Type of fan highest point
(m³/min) (pa) (r/min) motor power (KW)
(KW)
J
SDF(A)-2- 4.0 90-140 275-1450 2900 3.3 2.2K2
SDF(A)-2-J5.0 214-328 485-2695 2900 9.5 5.5K2

SDF(A)-2-J5.6 250-385 540-2900 2900 17.8 11K2

SDF(A)-2-J6.0 310-480 1350-4600 2900 25.1 15K2

SDF(A)-2-J6.3 450-725 1500-5000 2900 30.2 18.5K2

SDF(A)-2-J6.5 500-800 1600-5400 2900 .7.4 22K2

SDF(A)-2-J7.1 624-990 1900-6400 2900 54.2 30K2

SDF(A)-2-J7.5 700-1100 2120-6750 2900 67.3 37K2

SDF(A)-2-J8.0 760-1225 2400-7500 2900 83.7 45K2

SDF(A)-2-J8.0 770-1300 2600-8150 2900 102.3 55K2

1.4 SDF(A) !"#$%&'(*+,LMNOPQR


Schematic diagram of outline structure of SDF(A)special axial flow fans for
tunnel construction

1STUV Current collector 2SWXYZ[ Inlet muffling pot


3SWXYZ\ Inlet muffling cone 4S]^_8 Primary main machine
5S]^`a Primary impeller 6Sb^`a Secondary impeller
7Sb^_8 Secondary main machine 8ScXYZ[ Outlet muffling pot
9ScXYZ\ Outlet muffling cone
1.5 SDF(A) defghijklmnopqrst
Outline dimension table of SDF(A)special axial flow fans for tunnel
construction
uvwx d1 d2 d3 L
Type of fan y z
mm y z
mm y zmm y zmm
{
SDF(A)-2- 4.0
486 405 525 1730
SDF(A)-2-{5.0 600 505 625 2531
SDF(A)-2-{5.6 684 565 685 2835
SDF(A)-2-{6.0 720 605 725 3037
SDF(A)-2-{6.3 756 635 755 3188
SDF(A)-2-{6.5 780 655 775 3291
SDF(A)-2-{7.1 850 715 835 3594
SDF(A)-2-{7.5 900 755 875 3714
SDF(A)-2-{8.0 957 805 925 3890

2 |SDF(B) efghijklmn 2 | SDF(B) special axial flow fans for

o tunnel construction

2.1 }~
2.1 Characteristics
High efficiency, low noise, large air
€‚ƒu„…†‡ˆ‰Š‹ volume and energy saving, they are applicable to
ŒŽ‘’“Ž”•–… large or extra large tunnel construction such as

w—˜…w™š›œžŸ ¡¢”£ undersea tunnels. Angle of blade could be


expressway tunnels, two-way railway tunnels and

Ÿ¤¥¦§¨ˆ©uvª«¬­®¯°±› selectively adjusted in accordance with altitude


to make fans reach the best operation state.

2.2 nod²³´µ¶
2.2 Explanation of markings of fan type
S D F (B) -4- №9.6

·¸¹ 9.6º»¼½¾¿ 960mm


Machine number is 9.6, that is, diameter of impeller is 960mm
ÀvÁÂ Number of pole of motor
ÃÌÅÆ Single rotation high speed series
uv Fan
ÇÈ Counter rotating
 Tunnel
2.3 SDF(B) ÉÊËÌÍÎÏÐÑÒÓÔÕÖ×ØÙÚÛ
Technical performance parameter table of SDF(B)special axial flow fans for
tunnel construction

âãÜà äå æâçèé æêëìíÝ


ÜÝÞß Üà Üá High
Rotating Power at the èé Maximum
Air volume Air pressure efficient air
Type of fan speed highest point auxiliary motor
(m³/min) (pa) volume
(r/min) (KW) power (KW)
(m³/min)
î
SDF(B)-4- 9.6 680-1325 500-3200 1100 1480 58 30ï2
SDF(B)-4-î10 770-1500 550-3500 1225 1480 71 37ï2
SDF(B)-4-î10.5 891-1736 606-3859 1415 1480 85.5 45ï2
SDF(B)-4-î11 1015-1985 624-4150 1550 1480 107 55ï2
SDF(B)-4-î11.5 1171-2281 727-4628 1863 1480 135 75ï2
SDF(B)-4-î12.5 1550-2912 878-5355 2385 1480 216 110ï2
SDF(B)-4-î13 1695-3300 930-5920 2691 1480 259 132ï2
SDF(B)-4-î14 2113-4116 1078-6860 3361 1480 300 160ï2
SDF(B)-6-î14 1399-2725 473-3100 2226 980 110 75ï2
SDF(B)-6-î15 1721-3352 543-3559 2738 980 156 90ï2
SDF(B)-6-î16 2088-4068 618-4049 3323 980 206 110ï2
SDF(B)-6-î17 2505-4879 697-4571 3986 980 293 160ï2
SDF(B)-6-î18 2973-5792 782-5124 4731 980 389 200ï2
SDF(B)-6-î19 3210-6175 829-5412 5045 980 407 220ï2
SDF(B)-6-î20 3465-6684 878-5820 5478 980 472 250ï2
SDF(B)-6-î22 4158-8020 1010-6926 6552 980 596 315ï2
SDF(B)-6-î24 4948-9550 1192-8173 7730 980 685 355ï2
3ð SDF(C) ñòóôõö÷øùúû
3.1 üý 3. SDF(C) special axial flow fans for
þÿ  “ ”
tunnel construction
   3.1 Characteristics

ÿ  !"& "Pole changing multi-speed" could bring


High efficiency, low noise and energy saving.

'#$%  (,)*þ+-. different ventilation means and energy saving

2/0 137 effect for you with its different rotating speed. It
changes the nonadjustable defects of traditional
blades and realizes the selective adjustment, and
could be used for construction ventilation under
plateau climate environment

ð 4ñòóôõö÷øùúû
SDF(B) (C)
SDF(B) and (C) special axial flow fans for tunnel construction
3.2 úû45689:
Representation method of fan type
S D F (C) -- №10

;<= 10>?@A 1000mm


Machine No. is 10, that is, diameter of impeller is 1,000mm

BC Pole changing multispeed series


; Fan
DE Counter rotating
FG Tunnel
3.3 SDF(C) HIJKLMNOPQRSTUVWXYZ
Technical performance parameter table of SDF(C) special axial flow fans for
tunnel construction
cdef hlmnop
[\]^ [a [b High g_ hcijk jk
Type of _` Speed Air
volume
Air
pressure
efficient air
volume
Rotating
speed
Power at the
highest
Maximum
auxiliary
fan (m³/min) point (KW) motor power
(m³/min) (pa) (r/min)
(KW)
cr 770-1500 550-3500 1225 1480 71 s
37 2
tr
High speed
SDF(C)-
q 640-1010 240-1600 825 980 21.9 12
ur
10 Medium speed
420-760 140-880 619 750 9.3 6
cr
Low speed
1015-1985 624-4150 1550 1480 107 55
tr
High speed
SDF(C)-
q 690-1345 295-1900 1098 980 33.5 17
ur
11 Medium speed
540-1006 160-1095 825 750 15 8
cr
Low speed
1171-2285 727-4629 1865 1480 142.8 75
tr
High speed
SDF(C)-
q 975-1536 317-2116 1255 980 44.0 24
ur
11.5 Medium speed
639-1156 185-1164 941 750 18.7 12
cr
Low speed
1550-2912 1378-5355 2385 1480 208 110
tr
High speed
SDF(C)-
q 1052-1968 629-2445 1610 980 67.5 40
ur
12.5 Medium speed
840-1475 355-1375 1208 750 28.4 20
cr
Low speed
1695-3300 930-5920 2691 1480 259 132
tr
High speed
SDF(C)-
q13 1407-2219 406-2704 1813 980 81 45
ur
Medium speed
923-1670 237-1487 1360 750 34 22
cr
Low speed
2113-4116 1078-6860 3361 1480 360 185
tr
High speed
SDF(C)-
q 1756-2771 471-3136 2263 980 117 60
ur
14 Medium speed
1152-2085 274-1725 1698 750 50 30
Low speed
3.4 SDF(B) v(C)wxyz{|}~€‚ƒ„…†‡ˆ‰
Schematic diagram of outline structure of SDF(B) and (C) special axial flow
fans for tunnel construction

1Š‹Œ Current collector 2ŠŽ‘’ Inlet muffling pot


3Š“”•– Primary main machine 4Š—˜– Motor
5Š“”™š Primary impeller 6Š›”™š Secondary impeller
7Š›”•– Secondary main machine 8Šœ’ Outlet muffling pot

3.5 SDF(B) v(C)wxyz{|}~€‚ƒ„žŸ 


Outline dimension table of SDF(B) and (C) special axial flow fans for tunnel
construction
¡–¢£ ¤¥ L1 L2 L3 L4 L b b1 D
Type of fan Category

¦9.6 B 500 500 800 800 3800 780 680 1145

¦10 B
C
500
530
500
530
900
1050
900
1050
4110
4450
780
780
680
680
1190
1190
¦10.5 Š
B C 500 500 1000 1000 4500 780 680 1240

¦11 B
C
500
550
500
550
1000
1100
1000
1100
4660
4960
880
880
780
780
1290
1290

¦11.5 B
C
550
600
550
600
1100
1200
1100
1200
4960
5260
880
880
780
780
1340
1340
¦12.5 Š
B C 690 690 1380 1380 5630 1000 900 1450
§¨©ª «¬ L1 L2 L3 L4 L b b1 D
Type of fan Category
­13 ®
B C 690 690 1380 1380 5950 1000 900 1500
­14 B®C 750 750 1500 1500 6280 1080 980 1600
­15 B®C 750 750 1500 1500 6730 1080 980 1700
­16 B®C 850 850 1700 1700 7180 1180 1080 1800
­17 B®C 850 850 1700 1700 7640 1180 1080 1900
­18 B®C 900 900 1800 1800 8080 1280 1180 2000
­19 B®C 900 900 1900 1900 8530 1330 1230 2100
­20 B®C 950 950 2000 2000 8980 1400 1300 2200
­22 B®C 1000 1000 2200 2200 9880 1540 1440 2400
­24 B®C 1100 1100 2400 2400 10780 1680 1580 2600

4 ¯ SDF(D) °±²³´µ¶·¸¹º»¼½¾¿
SDF(D) energy saving four-stage counter rotating axial flow fans for long and
large tunnels

4.1 ÀÁ 4.1 Overview


After repeated experiments and research,
ÂéÄÅÆÇÈÉÊËÌÍÎ
SDF(D)
SDF(D) energy saving four-stage counter
rotating axial flow fans for long and large tunnels
§¨ÏÐÑÒÓÔÕÖ×ØÙÚÛÄ®ÅÆÇ are fans especially designed for long and large
tunnels, and have got national patents. They are
ÜÝÞΧ¨ßàáâãÙäåæçèéê® applicable to the long distance and constant air

ëêìíîïðÞÆÇñïòóôÄõ®ö§
volume ventilation of tunneling construction of
highway, railway and diversion works, and have
÷ÞΧØøùú§õûü®ýþÿ®G ® the characteristics of long air delivery distance,
low noise, high efficiency and large air volume,
§÷ÅåMÆÇòóõûÄ thus they solve the problem that ordinary axial
flow fans cannot meet air delivery demand when
S
ÌÍΧ¨ à ú§Þå tunneling distance is long.
SDF(D)  SDF(D) energy saving four-stage counter
rotating axial flow fans for long and large tunnels
!"#$%&'()*+!,+-./0 are applicable to the ventilation requirement

*!12-'34)./5678'9:;<
under plateau environment.For construction
ventilation under special environment, various

=>?@A./BCDE-F?HA./I spraying treatments of blades could also be made


according to the requirements of users.
J-KFLA./IJNO:LA./PQR Each stage of SDF(D) energy saving
four-stage counter rotating axial flow fans for
TU<V !WXY.)%D-ZBC[ long and large tunnels is driven by the same

1\]78J^_E)(`-aI;<)D
power motor. Impeller and motor are directly
connected and the rotation between adjacent
E-bcdefgAh5V !ij) k impellers is in opposite direction. Air flow could
get energy after entering to primary impeller,
lm&: accelerate through secondary impeller and then

hnopqrstu -vwxyz{
accelerate the removal after the last impeller. The
last impeller plays the function of static guide

|}h.~=€‚ƒ„…: vane in ordinary axial flow fan, which increases


the energy of air flow while getting the velocity
SDF(D) †D‡ˆ‰Š‹ŒAh5U< component in straightening circumference
direction, and then reach the higher air pressure
!Žzjqrs }: and efficiency than that of two-stage counter

4.2 ‘’
rotating fans.
4.2 Characteristics
“ ”•–—m&j—˜™š— kj— E Characteristics are long air delivery distance,
high efficiency, low noise, high air pressure,
‰—› E—†Dœ*ož-xy }- large air volume, constant air volume and energy

Ÿw ¡A-vwgA—¢A£-†
saving. Either single-stage or double-stage or
three-stage could be opened for operation

Dm¤¥¦: according to ventilation requirements. The


energy saving effect is obvious.

4.3 §¨©ª«¬­®¯
Explanation of markings of fan type

S D F (D) -- №10

!°± 10-²./1³ 1000mm


Machine No. is 10, that is, diameter of impeller is 1,000mm

´µ¶· Powerful series


! Fan
h5 Counter rotating
Š‹ Tunnel
4.4 SDF(D) ¸¹º»¼½¾¿ÀÁÂÃÄÅÆÇȹÉÊËÌ
Technical performance parameter table of SDF(D) energy saving four-stage
counter rotating axial flow fans for long and large tunnels

ÍÎÏÐ ÑÒ ÍÓ ÍÔ ÕÖ×ÎØÙ
Rotating speed Air volume Air pressure Auxiliary motor power
Type of fan
(r/min) (m³/min) (pa) (KW)
SDF(D) - Ú5.0 2900 180-275 860-48004800 Û4
5.5
SDF(D) -Ú5.3 2900 214-328 970-5390 7.5Û4
SDF(D) -Ú5.6 2900 250-385 1080-5800 11Û4
SDF(D) -Ú6.0 2900 275-432 2700-9200 15Û4
SDF(D) -Ú6.3 2900 318-500 3000-10000 18.5Û4
SDF(D) -Ú6.5 2900 350-550 3200-10800 22Û4
SDF(D) -Ú7.1 2900 410-680 3800-12800 30Û4
SDF(D) -Ú7.5 2900 510-740 4240-13500 37Û4
SDF(D) -Ú8.0 2900 520-800 4800-15000 45Û4
SDF(D) -Ú8.0 2900 537-895 5200-16300 55Û4
SDF(D) -Ú9.6 1450 680-1325 1000-6400 30Û4
SDF(D) -Ú10 1450 770-1500 1100-7000 37Û4
SDF(D) -Ú10.5 1450 897-1736 1212-7720 45Û4
SDF(D) -Ú11 1450 1015-1985 1200-8300 55Û4
SDF(D) -Ú11.5 1450 1170-2285 1450-9250 75Û4
SDF(D) -Ú12.5 1450 1550-2912 1720-10700 110Û4
SDF(D) -Ú13 1450 1695-3300 1860-12000 132Û4
SDF(D) -Ú14 1450 2113-4116 2156-13700 185Û4
SDF(D) -Ú14 980 1399-3013 946-6400 75Û4
SDF(D) -Ú15 980 1721-3760 1086-7120 90Û4
SDF(D) -Ú16 980 2088-4500 1236-8100 110Û4
SDF(D) -Ú17 980 2505-5100 1394-9142 160Û4
185Û4
SDF(D) -Ú18
2649-4479 1464-10510
200Û4
980
2962-5100 1904-11018
ÜÝÞß àá Üâ Üã äåæÝçè
Rotating speed Air volume Air pressure Auxiliary motor power
Type of fan
(r/min) (m³/min) (pa) (KW)
3302-5748 2456-11674 ê4
250
SDF(D) -é18 980 3643-6312 2916-12136 280ê4
3935-6772 3118-12728 315ê4
3115-5268 1632-11710 220ê4
3438-5998 2121-12278 250ê4
SDF(D) -é19 980 3884-6760 2736-13007 315ê4
4284-7424 3248-13562 355ê4
4629-7965 3474-14182 400ê4
3633-6144 1801-12974 280ê4
4063-6996 2350-13604 355ê4
SDF(D) -é20 980 4530-7885 3032-14412 400ê4
4997-8659 3600-15028 450ê4
5398-9290 3850-15714 500ê4
4206-7112 1992-14302 355ê4
4704-8099 2590-14998 450ê4
SDF(D) -é21 980 5244-9128 3342-15890 500ê4
5785-10024 3968-16568 560ê4
6249-10313 4244-14324 630ê4
4836-8178 2186-15698 450ê4
5408-9312 2844-16460 560ê4
SDF(D) -é22 980 6030-10495 3668-17440 630ê4
6651-11525 4356-18182 710ê4
7185-12365 4658-19012 800ê4
5525-9344 2390-17158 560ê4
6180-10640 3108-17992 710ê4
SDF(D) -é23 980 6890-11992 4008-19060 800ê4
7600-13169 4760-19874 900ê4
8210-14129 5092-20780 1000ê4
4.5 SDF(D) ëìíîïðñòóôõö÷øùúûüý
Schematic diagram of structure of SDF(D) energy saving four-stage counter
rotating axial flow fans for long and large tunnels

1þÿ Current collector 2þ Inlet muffling pot



 ( ) Main machine (I) 4þ  Motor

 () Main machine (II) 6þ
 () Main machine (III)

 () Main machine (IV) 8þ Outlet muffling pot
9þ Air cylinder joint
4.6 SDF(D) íîïôõö÷ø
Outline dimension table of SDF(D) special axial flow fans for tunnel
construction

 !
Type of fan
L L1 L2 L3 H d1 d2 d3 N- Weight
(kg)
"
SDF(D) - 5.0 4181 735 180 360 385 600 500 629 
12- 14 1190
SDF(D) -"5.3 4485 790 180 382 410 636 530 659 12-14 1280
SDF(D) -"5.6 4651 820 180 420 415 684 560 689 12-14 1600
SDF(D) -"6.0 4761 750 220 432 438 730 600 730 16-14 1750
SDF(D) -"6.3 4928 760 220 440 460 756 630 761 16-14 1900
SDF(D) -"6.5 5064 776 220 450 480 780 650 781 16-14 2070
SDF(D) -"7.1 5474 850 220 510 510 850 710 841 16-14 2260
SDF(D) -"7.5 5712 888 220 540 530 900 750 881 16-14 2470
SDF(D) -"8.0 6000 940 220 544 555 957 800 933 16-14 2700
SDF(D) -"9.6 5923 895 220 685 640 1152 960 1142 16-16 5000
#$%& ()
Type of fan
L L1 L2 L3 H d1 d2 d3 N-' Weight
(kg)
SDF(D) - *10 7030 1065 220 704 660 1220 1000 1182 '
16- 16 5700

SDF(D) -*10.5 7230 1065 240 704 680 1270 1050 1232 16-'16 6800

SDF(D) -*11 7650 1165 240 775 750 1328 1100 1284 20-'16 7850

SDF(D) -*11.5 8070 1265 240 810 760 1380 1150 1334 20-'16 9850

SDF(D) -*12.5 8690 1265 240 884 856 1494 1250 1436 20-'16 10540

SDF(D) -*13 9000 1420 240 884 856 1520 1300 1486 20-'18 11500

SDF(D) -*14 9680 1530 240 926 870 1620 1400 1600 20-'18 11900

SDF(D) -*15 10228 1618 240 996 910 1720 1500 1700 20-'18 12400

SDF(D) -*16 11040 1750 240 1066 970 1820 1600 1800 24-'18 12800

SDF(D) -*17 11780 1860 300 1336 1010 1920 1700 1900 24-'18 14450

SDF(D) -*18 12230 1923 300 1406 1054 2020 1808 1990 24-'18 14850

SDF(D) -*19 12950 2045 300 1484 1125 2132 1908 2090 24-'18 15770

SDF(D) -*20 13600 2150 300 1562 1195 2244 2008 2220 24-'18 17000

SDF(D) -*21 14270 2260 350 1640 1248 2356 2110 2320 30-'18 17320

SDF(D) -*22 14930 2365 350 1720 1300 2440 2210 2420 30-'18 18260

SDF(D) -*23 15550 2475 350 1830 1360 2550 2310 2520 30-'18 18860
5 + SFC ,-./0123456789:
SFC special draw-out axial flow fans for tunnel construction

5.1 ;< 5.1 Characteristics


Overall volume is small, air reversing efficiency
=>>?@ABCDEFGHIJG is high, energy consumption is low and noise is

KLJMNOPQGRSTUVWXYZ
low. They are applicable to vertical shaft
ventilation in long and large tunnel construction,

CA[\ZCG]^ZC_`aVbM parallel ventilation, subway ventilation and


drinking works.

5.2 9:,cdefgh
Explanation of markings of fan type

S F C -4 -- №10

ijk 10Almnop 1000mm


Machine No. is 10, that is, diameter of impeller is 1,000mm

qrAlsitr n=1450r/min
Pole of number, that is, revolution number of motor n=1450r/min

uvw Draw-out type


Ci Fan
ST Tunnel
5.3 SFC xyz{|}~€‚ƒ„…†‡ˆ‰Š‹ŒŽ
Technical performance parameter table of SFC special draw-out axial flow fans
for tunnel construction
“ ” •–—˜™ “ ” •–—˜™š
‘’ Air
Air pressure
š› Maximum ‘’ Air volume
Air › Maximum
Type of fan volume auxiliary motor Type of fan pressure auxiliary motor
(pa) (m³/min)
(m³/min) power (KW) (pa) power (KW)
SFC-4-œ10 6.4-19.6 230-899 15 SFC-6-œ13 9.5-29 178-694 
22(18.5 15)
SFC-4-œ11 8.5-26 278-1088 30(22) SFC-6-œ14 11.8-36.2 206-805 30(2218.5)
SFC-4-œ12 11.1-33.9 331-1294 14(37 30) SFC-6-œ15 14.5-44.6 236-924 45(3730)
SFC-4-œ13 14.1-43 389-1519 55(45) SFC-6-œ16 17.6-54.1 269-1051 75(554530)
SFC-6-œ10 4.3-13.2 105-411 7.5 SFC-6-œ17 21.1-64.9 304-1186 90(755545)
SFC-6-œ11 5.7-17.6 127-497 11 SFC-6-œ18 25.1-77 340-1330 110(90ž75ž55)

SFC-6-œ12 7.4-24.1 151-643 15(18.5) SFC-6-œ19 29.5-90.5 379-1482 132(110ž90ž75)

5.4 SFC xyz{|}~€‚ƒ„…†Ÿ ¡¢£¤¥Ž


Schematic diagram of outline structure of SFC special draw-out axial flow fans
for tunnel construction

1¦§¨© Current collector ¦ª« Main machine


2 ¦¬­« Motor
3
4¦®¯ Impeller 5¦°±© Diffuser
5.5 SFC ²³´µ¶·¸¹º»¼½¾¿ÀÁÂÃÄÅÆ
Outline dimension table of SFC special draw-out axial flow fans for tunnel
construction
ÇÈ
Machine d1 d2 d3 d4 d5 d6 d7 L A B H1 H2 n- É
number
10 1350 1300 1250 1009 1200 1250 1300 2635 920 888 700 1400 12-É12
11 1485 1435 1385 1111 1320 1370 1420 2940 930 990 808 1505 12-É12
12 1606 1556 1500 1211 1458 1511 1564 3146 1080 1020 840 1643 16-É14
13 1735 1683 1625 1311 1552 1607 1662 3285 1170 1110 870 1777 16-É14
14 1868 1812 1750 1415 1677 1636 1695 3524 1260 1200 980 1894 16-É14
15 1995 1935 1875 1512 1786 1850 1896 3815 1350 1290 1034 2031 16-É14
16 2126 2066 1996 1612 1916 1986 2046 4156 1420 1320 1113 2178 20-É16
17 2315 2245 2175 1714 2050 2120 2190 4630 1530 1420 1208 2363 20-É18
18 2450 2380 2310 1814 2170 2240 2310 4945 1620 1510 1215 2540 20-É18
19 2580 2510 2440 1914 2290 2360 2430 5160 1710 1600 1331 2650 20-É18
6 ÊËÌÍÎÏ
Jet fan
6.1 ÐÑ 6.1 Overview
SSF jet fan is a kind of new fan manufactured by
ÒÓÔÕÖ×ØÙÚÛÜÝÞß
SSF the Company through multiple times of research

àáâãäåæçèéê and experiment in accordance with the most


advanced level in the world and
ëìíîïðñòóô is applicable to the operation
ventilation of highway, railway
õÔÕãö÷øØùúû and subway tunnels. During

ùüýûþÿ(ð  installation, it shall either be in


longitudinal tandem arrangement
õÔ23ÚÛõÔ along the top of tunnel or in

7ã:ÿ(

concentrated parallel
arrangement at the cross section
? ÿ(à of tunnel inlet in accordance with
ventilation network parameters.
Ô During operation, fan of

2 0ÚÛÿ(ð
corresponding number shall be
started in accordance with
NãQðÔÕãV õÔ visibility in tunnel to reach ventilation purpose.
Thus, jet fan is a kind of ventilation means with
ð!ð2["ãÒÓÔÕÖñò#$%&ã3 simple maintenance and economic in installation

ú 0')ä*ðõÔ+ 2
and operation aspects.
6.2 Characteristics
6.2 ,-
The core part of SSF jet fan is the technology
of impeller. By referring to high technical level
SSF ÒÓÔÕð.í/14ð56ã8Ü in the world and after continuous research and

Ý956áâäå;ðèéúnëão<N experiment, the series specifications and types


meeting different demands are formed. They
q=;>@AðBCDEôFã{GHIJ have the following characteristics:
(1) Blades of impeller have the characteristics of
€ adjustable, light weight, corrosion resistance,

(1) 14ð1gKLã…Mú‡OPú‡
high temperature resistance and non-breaking,
which could ensure the service life of fans;
9lú‡RSú;mþJ€ãŽTUÔÕð (2) Cross section of blades is in wing shape,

‘÷WX2
which has good aerodynamic shape and could
ensure the performance of large pushing force of
(2) 1gYÕZôã{G\]ð^_
fans;
(3) Number and angle of blades could be
šo`ãŽTUÔÕašbðcN2 changed according to the requirement to make

(3) KÚÛ@ƒde1güfã‘Ô
the performance scope of fans be wide and meet
demands of different users.
ÕðcNhijkãNq=;>÷pð@A2 (4) New micropunch plate noise reduction
structure is used, reaching the purpose of large
(4) ¨÷óôðrstuvwxyã z sound absorption coefficient, wide sound

wBbãzw±|jãG}ý~U‚w2
absorption frequency band and effective
reduction of noise.
(5)„†ˆ‰Š‹‰ŠŒŠ’ 65%“ (5) Direct air reversal can be conducted and air
reversal efficiency is more than 65% of direct air,
”•–„—˜™›œžŸ 95%“”. or could also reach more than 95% according to
(6)  ¡¢ £¢¤¥¦„§©ª«‹¬­‹
the requirements of users.

®¯°²•
(6) Impeller, blades and motor can be removed
separately, thus maintenance is convenient

6.3 ³´µ¶·¸¹º»
Explanation of markings of fan type

S S F -2- -- №8

¥¼‹ ¡†½¾ 800mm
Machine number, that is, diameter of impeller is 800mm

¤¥¿À‹Á 2P Â䥾 2 ¿
Number of pole of motor, that is, 2P means motor is 2 poles

Š¥ Fan

ÄÅ Jet flow

ÆÇ Tunnel

6.4 SSF ³´ÈÉ 6.4 SSF fan structure


SSF ÄŊ¥ÊËÌÍÎÏÅТÑÒТ
Generally, SSF jet fans include current
collectors, mufflers, rectification parts, main
ÓÅÔ¢Õ¥¢ ¡¢¤Ö¥‹× (Ø 2) Ù machines, impellers and motors, as shown (in
ڕ Figure 2).

(1) ÏÅÐÎÅÛܒÏÅЄÝÞߊ¥’
(1) Current collector: Streamline current
collector could make the air flow entering to fans
àŦáâã‹ä劥’æ猍¢èéŠ be even and stable, and improve the operation

¥’êҕ efficiency and lower the noise of fans.


(2) Muffler: Mufflers are provided on both
(2) ÑÒÐΊ¥ÞëàìíîïÑÒÐ•Ñ sides of inlet and outlet of fans. Muffler is a two
Òоìðñòóô‹õò¾ö÷¥‹øò¾ layer of cylinder structure. The internal cylinder

ùúûñüˆýþ‹ÿj 匒
is puncher while the external cylinder is welded
with steel plates. The middle part is filled with
q• high efficient sound absorption material.

(3) ÓÅÔÎÅÛܒÓÅԄ݊¥õÅ2
(3) Rectification part: Streamline rectification
part could make the flow field in fans be
sŸ‹ä劥’æ猍è銥’ê optimized,
ҕ improve the operation efficiency and lower
the noise of fans.
(4) :
 (4) Main machine: Enclosure is welded by steel
 !"#$ plates. Flanges on both sides make mufflers be
conveniently connected to main machine.
%&'()*+,-./ Mounting plate of motor is welded in internal

(5) 0130456789:;<=>/
wall of cylinder to make the contact be closer.
(5) Impeller: Blades are adjustable to meet

(6) "?3@9AB"CD5EFG
different demands of users.
(6) Motor: Special motor is used. It is reliable in
HIJKLMNCO/PQ"RS 380VT operation and could adapt to the running in high
temperature environment. Rated voltage is 380V,
US 50HZVWXY F Y/ frequency is 50HZ and insulation grade is grade
F.

6.5 SSF Z[\]^_`abcdefg


Technical parameter table of SSF jet fans for tunnel operation
h ik lm nopr tuvw "xU vw/xU
Machine Pole Flow Outlet air speed Axial thrust Power of motor Thrust/Power
number number (m³/s) (m/s) (N) (KW) (N/KW)
2P 14.6 46.9 1161.7 22 49.4
6.3 2P 12.0 38.5 784.8 18.5 39.7
2P 10.0 32.1 545 15 34
2P 20.9 52.8 1175 37 28.7
2P 17.6 44.5 833.2 30 25.1
7.1
4P 10.4 26.3 287.8 7.5 44.9
4P 7.1 18.0 134.1 5.5 28.5
4P 14.8 29.5 463.9 15 39.8
8.0 4P 12.2 24.3 315.2 11 36.9
4P 9.6 19.1 219.4 7.5 37.6
4P 21.1 33.2 743 22 35.4
9.0 4P 17.8 28.0 528 18.5 30
4P 14.5 22.8 350.9 15 24.5
4P 33 38.6 1432.8 37 36
4P 29.7 35.9 1160.6 30 35.5
4P 26.5 33.8 924 22 38.5
10.0
4P 23.3 29.7 800 18.5 40
6P 20.0 25.5 517.3 15 47.2
6P 16.7 21.3 360.7 11 44.9
4P 40.7 41.4 1781.9 45 39.1
11.2
4P 37.4 37.7 1430.6 37 38.2
h ik lm nopr tuvw "xU vw/xU
Machine Pole Flow Outlet air speed Axial thrust Power of motor Thrust/Power
number number (m³/s) (m/s) (N) (KW) (N/KW)
4P 33.8 34.4 1228.9 30 40.5
4P 30.6 31.2 972.4 22 43.7
11.2 4P 28.4 28.9 867.6 18.5 46.3
6P 27.5 27.9 814 22 42.1
6P 24.2 24.6 630.4 15 47.8
4P 50.0 44.3 2348.2 45 35.7
4P 46.7 41.4 2048.5 37 37.9
4P 43.1 38.2 1745 30 39.8
12.0
4P 39.3 35.4 1495.5 22 46.5
6P 33.8 29.9 1072.7 30 39.3
6P 30.2 26.7 856.4 22 42.8
4P 56.5 46.1 2764.8 55 34.2
4P 53.2 43.4 2451.3 45 37.1
12.5 4P 49.6 43.0 2130.7 37 39.2
6P 38.2 31.2 1262.9 30 42.4
6P 34.9 28.5 1054.1 22 48.2
6P 53.7 34.9 1987.2 55 33.7
6P 50.4 32.8 1750.5 45 40.5
6P 47.2 30.7 1535.2 37 43.4
14.0
6P 44 28.6 1334.1 30 45.9
8P 41.1 26.7 1163.9 30 44.0
8P 37.8 24.6 984.5 22 50.8
6P 80.1 39.9 3390.1 90 29.5
6P 76.8 38.3 3116.5 75 32.5
6P 73.2 36.5 2831.2 55 36.1
16.0
8P 61.3 30.5 1985.6 55 38.5
8P 58 28.9 177.6 45 42.1
8P 54.4 27.1 1563.8 37 45.1
6P 114.1 44.9 5430.3 132 26.2
6P 110.8 43.6 5120.7 110 27.2
18.0 6P 107.2 42.2 4793.4 90 27.5
8P 87.3 34.3 3180.5 110 34.2
8P 84.0 33.0 2944.6 90 38.7

6.6 SSF yz{|}~€‚ƒ„…†‡ˆ


Schematic diagram of outline structure of SSF jet fans for tunnel operation

1‰Š‹Œ Current collector 2‰ŽŒ Muffler 3‰‹ Rectification part


4‰‘’ Main machine 5‰“” Impeller 6‰•–’ Motor
6.7 SSF —˜™š›œžŸ ¡¢£
Outline dimension table of SSF jet fans for tunnel operation

¤¥ ¦§
A B C D E1 E2 F G H d1 d2 n-d3 Weight
Type
(kg)
6.3 1050 378 2478 560 228 - 424 504 1094 634 894 4-13 640

7.1 1183 426 2792 630 276 - 488 568 1174 714 974 4-13 783

8.0 1333 480 3146 710 330 - 560 640 1264 804 1064 4-13 926

9.0 1500 530 3530 800 380 - 648 720 1370 904 1170 4-13 1074

10.0 1677 600 3954 888 450 - 722 800 1472 1004 1272 4-15 1270

11.2 1867 672 4406 990 522 - 816 896 1584 1124 1384 4-15 1500

12.0 1920 690 4530 1023 - 274 847 922 1617 1156 1425 4-15 1620

12.5 2000 720 4720 1065 - 285 882 960 1684 1204 1484 4-15 1700

14.0 2333 840 5506 1243 - 345 1036 1120 1884 1404 1684 6-17 2600

16.0 2667 960 6294 1420 - 280 1196 1280 2084 1604 1884 6-17 2890

18.0 3000 1080 7080 1600 - 340 1352 1440 2284 1804 2084 6-17 3600

6.8 ¨©ª™«¬­® (1) ¯‹°’±²³´¯‹°’µ¶·¸¹


º»¼½¾¿ÀÁÂÃÄÅÆÇÈÉÊËÌÍ maintenance

ÎÏÐÑ
(1) Embedded parts of jet fans are very
important for the accurate installation and
(2) ÒÓÔÕ½Ö×ØÙÚÛÜÝÞÔÕÃ
hanging safety of jet fans, thus the quality of

ØÙßàá¼âãäåæçÔÕÃØÙèÔÕ
embedded parts shall be strictly controlled.
(2) During installation of jet fans, fans shall not
éêÑ be damaged and shall not be hoisted by hooking

(3) ½ÖÔÕ×ÃÆëìíÔÕîÎÔïð
muffler. Welding shall not be conducted for fans.
(3) During installation of fans, pay attention to
ñòóôÎßÔõïö÷øùúûÔÕüýò make the wind indicator on fans be consistent

óôÎþÿý: ÑIÃKÔÎ
with the ventilation direction of tunnel, and
ensure the axis of fans be parallel to the center
Ý$Ñ line of tunnel. Otherwise, extra loss of wind

(4) ÔÕ×ÃÆ ÔÕ



power will be increased.
(4) During starting of fans, check if there is any
ÔÕ
Ã`õïIò other thing in fans, if the connecting bolts of fans

ÔÕîÎõïðñö÷Ñ
become loose and if the rotation direction of
blades is consistent with the wind indicator on
(5) ÔÕ×ÃeèÎÃÆ
fans.

lÔÕÃnöÔÕ !"#%Ã
(5) During starting of fans, fans shall be started
one by one in order to reduce the impact on
õ<&öÔÕÑ power grid, that is, only when one fan reaches

(6) ÒÓÔÕ'(ï)ï×ÃÆ*ÔÕ`+
rated rotating speed, can the next fan be started.
(6) During changing of forward and reverse
{,%Ã}ß(ï-Ñ direction, the reversal power supply shall be

(7) ÔÕ ./0ÎÎ12ú345Ç.
connected after the impellers of fans completely
stop.
"qëÕü6789Ñ (7) Fans need to special maintenance and only

(8) "q;=âã>?@ÒAâã>BC
need to be regularly filled with motor bearing
lubricating oil.
?@DØEâãFGÑ (8) Regularly clean the dust on muffling plate to
prevent muffling plate hole from being blocked
6.8 Installation, operation and
by dust and muffling effect from being affected.

HJL MNOPQR
Chapter III High pressure spray fans
1STU (1) Power is strong, range is long and coverage
scope is wide, could realize accurate spray.
(1) VWXYZ[\Y]^_abYcdfg Working efficiency is high and spray speed is

hijkmopr fast;
(2) During water spray
sYijtuvk and de-dusting of

(2) wxyz|~
storage yard where dust
can be easily raised, the
€‚iƒ„~ small particles sprayed
can form a kind of wet
…†iˆ€j‰Š vaporific material when

‹YŒ|€~Ž contacting with the


floating dust to rapidly
…†‘“”•–— suppress the dust.

j™š†›vtœ~
(3) Auxiliary power is
flexible, as either three
žŸ k phase 380V city power
or diesel power
(3) ¡ ¢ £ W ¤ generating set can be

¥†¦c§¨© 380V €ª«†¬c¡¢­® used together for power supply.


(4) It can either be fixed at concrete pouring
¯«°±²«k platform or be installed at transportation vehicle

(4) c³´µ¶·¸¹º»¼€½¾¿†¬c
together with diesel power generating set.
(5) Operation is flexible and using is safe and
¡¢­®¯«°±²«µ¶·ÀÁÂÿk reliable. Remote control and manual control
operation could control and adjust horizontal
(5) Äo¤¥†Å§µÆcdžÈÉÊËmÉ rotation spray angle at will.

žÄo†cÌÍɞÎσ½ÐÑijÒuk (6) Comparing with other dust suppression and


spray equipment, water consumption can be
(6) Ӄh©ÔÕ֝~i×ØÙcÏÚ Û
saved by 70% 80% (spray gun and watering

70%Û80%(iÜY׃°Â )†Ýƒj]^Þ~
vehicle) and water mist covering dust area is far
larger than that of other dust suppression and
ßà\\áâÕ֝~i×ØÙã spray equipment.

2. Applicable scope
2Säåæç (1) PM2.5 air exceeding standard treatment in
cities, pollution reduction, de-dusting and haze
(1) èª PM2.5 éêëìíîYíïŸ~ð reduction, city environment treatment;

ñYèªòóíîk ôõ‚Yöô÷øÆùúûôõöü‚
(2)

ýYôõþÿ YôõÀY ô
¤Y¥ßÊé
~ï íîk
1. Characteristics
(3)     logistics parks, coal concentrated transportation
stations, open pit coal mine mining and road and
 !" #$ %&' air flying dust pollution treatment after blasting.

()"*
(3) Flying dust treatment in storage yards, spray
and dust suppression in all coal piles, material
(4) +,-./01234567
piles, ash piles and storage yard open loading and
unloading operation, spray or sprinkle of
89 9)* stabilizer for dust suppression.
(4) Tunnel construction, tunnel face blasting
(5)+,-.:;.<=>)-..? dust, smoke purification, flying dust of material

@ABCD-:;EFGHGI
transportation vehicles and piling unloading
vehicles, etc;
JKLMNOPQRST)* (5) Flying dust treatment of tunnel construction,
construction sites and demolition works,
(6) UVWXVWYZ[\]E municipal infrastructure, construction wastes,

FH\)^NOPQUR9_`Ka
waste residues and materials, loading and
unloading and piling, and other activities

b9cVWd?efUgh$ijkNO producing flying dust pollution;


(6) Material transportation, for example, flying
PQ* dust pollution treatment during transportation of
materials by vehicles or heavy duty vehicles
(7) l<1m-n7.?op that are easily produce flying dust pollution such

qn7 #rs-*
as cokes, gravels, earthwork, garbage or mucks
due to the scattering or leakage of materials.
(8) tuvwxy z{|
(7) Flying dust of bare surface, implement
greening work and effectively take greening,
}[~€VV V‚,ƒ spraying and de-dusting measures;

)PQ`Kxy„…*
(8) Dust pollution treatment of coal wharfs,
coastal port stockyards, operation of bucket
(9) †9y‡9ˆb‰
wheel machine, hauling, transportation and
transfer of ores and bulk powder, and channel
9.* improvement, and port environmental treatment;
(9) Truck discharge opening, dumper discharge
(10) Š|‹ŒŽ9tu‘ dust and large load carrier working dust

IEF’“) ”•–—˜ VT


treatment;
(10) Spray sterilization and disinfection at
<™š<)r›œr—˜* airports, expressways, stations, ports, public
places and refuse landfill, and de-dusting,
(11) ž ”Ÿ¡¢ ”n7£ ” moisturizing, cooling and disinfection of sports

))!7¦Œ§¨1©ˆª
fields and hot places.
(11) Chemical spray at forest farms and
(2) Coal storage yards, storage bunkers or greening belts and for crops in farms. The
completely closed coal storage sites, coal atomization is good, speed is fast and area is
large.

3 «¬­®¯°±²³
Explanation of markings of fan type
G P F -15

´µ¶·¸¹º»´µ¶·¸¹ 15m
Maximum horizontal range, that is, maximum horizontal range is 15m.

¼½ Fan
¾¿ Spray
ÀÁ High pressure
4 ÂGPF ÃÄÅÆÇÈÉÊËÌÍÎ
Technical parameter table of GPF high pressure spray fans

¶·¸ ÑÒÓ ÕÖ ×ØÁÙ âã æçèé


ÏÐ ¹ Ô Consum Liquid ¿ÚÛ
Atomized
ÜÝÏÞ ßàá äå ½ê
Þ Prote Diesel
Horizont Covera pump Type of
Type ption particle size Control ction
al range ge area pressure equipment generating
(L/min) (µm) means grad
(m) (m2) (MPa) set
e
GPF-15 8-15 4-9
1.5-3.0
50-100
óô/õ 15KW

ëì/íî ß/öô/ øù
GPF-35 25-35 9-18 50-150 22KW
GPF-50 50 60-118 30-150
/ïð/ñ
÷¹ IP55 40KW
GPF-60 60 7000 60-118
ò operatio
Manual
Not
50KW
GPF-80 80 13000 100-160 Simple/or lowe 150KW
20-200 n/remote
GPF-100 100 20000 120-180 2.0-3.5 dinary/sta r 200KW
control/a
ndard/stre than
GPF-120 120 29000 150-220 utomatic 250KW
ngthened IP55
GPF-150 150 45000 160-240 /long-dis 300KW
30-300 tance
GPF-200 200 62000 180-300 350KW

ÝúûüýÏм½¶·þÿ<Û û±170° Remarks: Horizontal rotation angle of fan of

B<Û û-10°D +40° each type: ±170°


Elevation angle: -10° D +40°
EÛû-30JD +42J Using environment temperature: -30 J
D +42J
5 GPF ÃÄÅÆÇÈ

Schematic diagram of outline structure of GPF high pressure spray fans
1 1Current collector
2 2Diversion device
3 3Main machine
4 4Motor
5 5Cone cylinder
6 6Diffuser
7 7Rotation shaft
8 8Generator
9 9Storage battery
10!" 10Diesel engine
11#$% 11Pump intake
12&' 12Power distribution cabinet
13(# 13Motor and pump body
6)GPF *+,-./01234
Outline dimension table of GPF high pressure spray fans
56 789: Outline dimension
Type φ L L1 L2 L3 L4 L5 L6 L7 H H1

GPF-15 500 1402 42 600 580 105 75 1100 1300 1850 1600

GPF-35 600 1575 42 708 649 106 75 1160 1400 1980 1678

GPF-50 630 1671 42 768 680 106 75 1300 1600 2100 1785

GPF-60 670 1763 42 828 712 106 75 1320 1700 2150 1815

GPF-80 710 1900 42 888 740 150 80 1400 1800 2200 1845

GPF-100 800 1992 42 920 800 150 80 1450 1850 2250 1850

GPF-120 830 2962 42 1800 820 200 100 1600 2200 2400 1985

GPF-150 840 3222 42 2000 830 250 100 1800 2250 2450 2030

GPF-200 850 3802 42 2500 840 300 120 2000 2500 2580 2155
;=>?
@A CFGHIKLMNOPQRSTUVWXYAZ[\]^_
`A abcdefLghiQTUV]^WLjklmnopqrCFsti]_
uA abTUVvwxyz{|}CFRS~]^KLjklqrCF€‚Aƒ„…†f
TUV_
‡A CFiˆ]^KRiCTUV‰Š‹VŒvwxe}KLqGŽ[x‘‹V’_
“A w[@”e•‹–—˜™šA›œžŸ ¡LaCFS~Lwklq¢£ƒ¤A¥¦_
§HIK¨©ª«¬cd­
(1) ‹V®Q¯°A±d (²³) ž´°µ
(2) UV®Q¶¤‹·µ
(3) UV‹–¸] (¹º»¼\]^) ž—˜½¾_

Ordering instruction
1. When ordering, users shall determine the variety, specification and type of fan required at first.
2. In case parameters are inaccurate and type of fan cannot be selected, technical personnel of the
Company can help users select the type.
3. In case there is no type suitable for users at fan samples, the Company could design and
manufacture non-standard fans for users separately.
4. In case the auxiliary motor selected by users at the time of type selection does not conform to that
in sample, the difference price of motor could be increased or reduced on the basis of this price.
5. This price does not include electric control starting device, diffusion tower and muffler. In case it is
required by users, the Company could be responsible for making and purchase on users' behalf.

§ The following parameters shall be specified in ordering:


(1) Rated power, pole number (rotating speed) and frequency of motor;
(2) Rated working voltage of fan;
(3) Electric control type (outline dimension and type) and starting means of fan
¿ÀÁÂÃ
Service never ends
ÄÅÆÇÈ
Honesty never fades

https://chinahxfj.en.alibaba.com/
Email:chinahxfj@163.com
Mobile phone/whatapp:+8613133199762
Skype:hongxin3545 chinahxfj@163.com
Website: http://www.sxhxfj.com
Address: Peijie, Xia County, Yuncheng, Shanxi

You might also like