ZC Emergency shutdown
Compensator Globe valve Driver general Local gauge board
00
XooY
LGB
FF
M UC
B Foundation Fieldbus Instrument Start up Interlock B
10
Orifice Gate valve Motor driver
UC
Oil Pump Control
Local control panel (LCP) 20
Local panel mounted instrument
Spectacle blind Globe valve with silencer Diaphragm driver
UC
Oil Heater Control
ML 23
Motor Status Pilot Light
C IAS UC C
Oil vapour extraction control
Control in DCS
Venturi tube Ball valve Diaphragm driver 24
with positioner XL
Status Light
UC
Oil Cooler Fan Control
25
ZC Shutdown
CCS (by Customer)
3-way valve Diaphragm controller (self acting) Compressor Control System 41 Seal Gas Booster Trip
CCS
E E
ESD (by Customer) For interlock tagging
Sight glass 3-way cock Controller general (self acting) Emergency Shutdown System please see note below "interlock tagging"
ESD
XXX
S C C S
FO = Failure open
Float trap FC = Failure closed
Safety valve (angle type) LO = Locked open
Reducing station with filter S = Siemens Battery limit for LC = Locked closed
C = Customer customer connection LP = Locked in Position
PI NO = Normally open
NC = Normally closed
FP = Fail in position
Cooler (Water tubeside) Flap
Heat exchanger General notes:
of damages. All rights created by patent grant or registration of a utillity model
express authorization are prohibited. Offenders will be held liable for payment
well as utilization of its contents and communication thereof to others without
Transmittal, reproduction, dissemination and/or editing of this document as
G - All cabling between local instruments and skid mounted junction boxes G
supplied by Siemens.
- All cabling between other location (like cabinets, panels, DCS, etc.)
Plate heat exchanger supplied by customer.
Non-return valve
Hydraulic symbols - All spare elements wird up to skid mounted junction box.
- Additional Tag/Item outside elements necessary for Siemens internal use
and for maintenance guide.
Swing Check Valve and multi-way valves - All pipes shown in dotted line by customer.
H 10040 H
PO Nº 1004005010
Fabric filter Throttling valve adjustable
Check valve CONTRACTOR CONTRACTOR DOC. No REV.
Doc. Code FADHILI GAS PROGRAM (FGP)
PROJECT
DIA-0001 V-D43-K-1801A-0002 I
Throttling check back valve adjustable VENDOR NAME / LOGO NMR Code:
Gas filter
602
Vent breather
J UNIT / EQUIP. No : J
D43-K-1801A/B D43-K-2801A/B
D43-K-3801A/B D43-K-4801A/B
Pumps DOCUMENT TITLE:
Coalescer filter Protective strainer P+I DIAGRAM LEGEND
For D43-K-1801A : ZC/UC-12xx : i.e. UC-1220 A - REJECTED C - REVI EWED WITH COMMENTS F - REVIEWED WITHOUT COMMENTS
For D43-K-1801B : ZC/UC-13xx : i.e. UC-1320
Level gauge Inlet guide vane For D43-K-2801A : ZC/UC-22xx : i.e. UC-2220
Screw pump For D43-K-2801B : ZC/UC-23xx : i.e. UC-2320 B - COMMENTS AS NOTED R - REVIEWED AS BUILT I - FOR INFORMATION
DATE : 22/05/2017
For D43-K-3801A : ZC/UC-32xx : i.e. UC-3220
For D43-K-3801B : ZC/UC-33xx : i.e. UC-3320
For D43-K-4801A : ZC/UC-42xx : i.e. UC-4220
Rotary pump For D43-K-4801B : ZC/UC-43xx : i.e. UC-4320 Siemens Project: FADHILI - Saudi Aramco
Booster Floater
L L
Siemens Project No.: BC000146C02
Schadenersatz. Alle Rechte für den Fall der Patenterteilung, Gebrauchsmuster-
Weitergabe sowie Vervielfältigung, Verbreitung und/oder Bearbeitung dieses
Local Electrical Motor Control Station Local Electrical Motor Control Station Note 1 Local Electrical Motor Control Station
Local Electrical Motor Control Station Note 1 Detail 3: mounted in Local Control Panel (LCP)
A A
HS HS HS ML ML HS HS ML ML HS HS ML ML
HS HS HS ML ML ML ML
-----C -----A -----B -----A -----B --------A --------B --------A --------B
S
----.A ----.B ----.A ----.B
----C ----A ----B ----A ----B
S
Local/Remote Start Stop Running Stopped ------A ------B Start Stop Running Stopped
C
Start Stop Running Stopped
Local/Remote Start Stop Running Stopped
C
Heating Stopped
C
Note 1: Local Control Panel (LCP)
Note 1:
XL Local Electrical Motor Control Station ML D43-313-LCP-1201
C
---- ----.C
B ML ML ------C B
LCP Local/Remote Status Running/Stopped
C
Running/Stopped
C
----D ----E XL MCC Running/Stopped
S
MCC
S
Running Stopped ML ML ML ML ML ML
----- ML ML
LCP LCP LCP
Local Control Panel (LCP) ----C --------C
-----D -----E Local/Remote Status ----.D ----.E --------D --------E
D43-313-LCP-1201
Running/Stopped Running Stopped Running Stopped Running/Stopped
MA Running Stopped MA
Local Control Panel (LCP) Local Control Panel (LCP) Local Control Panel (LCP)
HS D43-313-LCP-1201 ----- D43-313-LCP-1201
D43-313-LCP-1201 ----. MA
C
M ----E Com Fault Com Fault
S
--------
C Stop C
HS Com Fault
HS -----D
HS
----D Start
--------E
Start HS HS Stop
XA -----E ----.E
MCC MCC Applicable for MCC
Applicable for: Stop Applicable for: Applicable for:
---- Stop - Motor space heater
Applicable for lube oil pumps - Oil Cooler Fan Motors B & C - Oil Cooler Fan Motor A - Oil Mist Fan Motor
Com Fault UC
D UC D
Detail 2 Detail 3
Detail 1 ----- Detail 2b Detail 4
----. P&ID Symbol
C
P&ID Symbol S C
C
P&ID Symbol P&ID Symbol S C P&ID Symbol
M
S
M M
S
VT VT
HS VAHH
HS VAHH
HS HS
Detail 1 Detail 2 ---- ---- ML
---- ---- Detail 2b ---- Detail 4
----- ----. Detail 3 --------
------
H
VI H
VI
M
E M ---- E
----
Example
M M
Local Control Panel (LCP) (see also Motor P&ID V-D43-K-1801A-0004) Detail 8: mounted in Local Control Panel (LCP)
F D43-313-LCP-1201 Detail 7: mounted in Local Control Panel (LCP) F
Detail 6: mounted in Local Control Panel (LCP)
ML ML ML
ML ML ML ML
HS HS HS ML ML
ML --.--.--A --.--.--B --.--.--C
S
--A --B -.-.-.-A -.-.-.-B
S
S
C
Heating Stopped Heating Stopped -.-.-.-C
C
C
D43-313-LCP-1201 --.--.--A
XA
of damages. All rights created by patent grant or registration of a utillity model
express authorization are prohibited. Offenders will be held liable for payment
well as utilization of its contents and communication thereof to others without
MCC Note 2
Transmittal, reproduction, dissemination and/or editing of this document as
ZC Start
C
C
Note 1: Supplied by Vendor
H Reset ON/OFF Note 2: fault signal is received Com Fault H
M
S
---B
TC TS
when the temperature switch M
Stop Applicable for Applicable for cut-off the power supply. Applicable for:
Note 3: temperature control
C
HS - Seal gas heater - oil heater -.-.-.- -.-.-.- - Seal Gas Booster
can be activated when
the level is not low.
S
Detail 6
---A Note 1 Note 1
Detail 5 P&ID Symbol Detail 7 Detail 8
P&ID Symbol Start P&ID Symbol P&ID Symbol
XA
HS ML
Detail 5 --- Detail 6 ML HS
J --- -- Detail 7 Detail 8 J
Available -.-.-.- --.--.--
II M
M ---
Current CCS
L L
Schadenersatz. Alle Rechte für den Fall der Patenterteilung, Gebrauchsmuster-
Weitergabe sowie Vervielfältigung, Verbreitung und/oder Bearbeitung dieses
Dokumentes, Verwertung und Mitteilung seines Inhaltes sind verboten,
soweit nicht ausdrücklich gestattet. Zuwiderhandlungen verpflichten zu
M
geprüft
review
freigegeben
2016-10-10 La Rocca, A P+I Diagram Legend
checked 2016-10-10 Kreis, S