Professional Documents
Culture Documents
Section - A - LT PANEL
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
Note:LT panels,Light Fitting,UPS System will be suppiled from client
1. ALL Panel shall be made out of 14 /16 SWG CRCA sheet steel with CNC
punched.
2. The panel shall be provided with Aluminium earth bus bars of at least one
third capacity of the phase bar rating along with the entire length of the panel
and cost of the same shall be included in cost of the panel.However the
minimum size of the bar shall be 25 x 6 mm Cu. Flat only
3. The bus bar chamber size shall not be less than 300 mm in all sub switch
boards.
4. The cable chamber width shall not be less than 300 mm in case of all floor
mounted boards. In respect of wall mounted boards 250 mm width is
acceptable.
5. All MCCBs / FSUs shall be provided with front drive mechanism with
necessary door interlock.
6. MCCBs with more than 125 A rating shall be provided with spreaders and
terminal shrouds.
7. The panel shall be powder coated finish with RAL 7035 Shade.
8. All MCCBs are Ics = 100% Icu only.
KA Rating
up to 100A - 25KA
125A to 315A - 36 KA
400 to - 1250A - 50KA
1
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
POWER PANEL(TOP/BOTTOM ENTRY)
Supply ,Installation, Testing and Commissioning of Medium Voltage floor
mounting Cubicle Type Distribution Board suitable for 415 V, 3 Phase, 50 Hz
Power Distribution System with the following mounting complete as per
specifications attached.
INCOMER
100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 36 kA
Short Circuit Rating with Adjustable Thermal O/L and Magnetic S/C Protection
- 2Nos
OUTGOINGS:
80 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA
Short Circuit Rating with Adjustable Thermal O/L and Magnetic S/C Protection
- 6Nos
BUSBAR:
1 Set of 250 A, TP& N Aluminium Bus bar Chamber for the entire length of the
MV Panel with 0.8 A/mm2 Current Density. All the Vertical and horizontal Bus
bar shall be of same size and rating.
1 Set of R Y B LED Type Indicating Lamps with Control MCB and MFM 1 NO
EXISTING PANEL
Removing of already exisiting SFU and replacing with 100 Amps TP&N Fixed
Type SFU unit to the exisiting panel 2 NO
Removing of already exisiting SFU and replacing with 200 Amps TP&N Fixed
Type SFU unit to the exisiting panel
Qro NO
2
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
3
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
3 no
4
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
Light Fittings,Fans
a)Recess Mounted LED Fitting 132 nos
bRecess Mounted Down Lighter (18W Led Fitting) 58 nos
c) 1 x 40 W Tube Light Fitting 4 nos
d)Surface Mounted T5 LED Fitting 36w( For Board Light) 90 nos
e)Surface Mounted T5 LED Fitting 36w( For Board Light) 2 nos
f)Recess Mounted Down Lighter( Model Coin 111 AC or Equivalent) 2 nos
g)Doctor Board Display Light 1 nos
h)Track Led Lighting qro nos
i)Hanging Light Fitting qro nos
Fans
a)1200mm Sweep Ceiling Fan necessary accessories 75 nos
b)305mm Sweep, Heavy Duty Industrial Type Exhaust Fan 6 nos
c)Wall Mounted Fan 14 nos
Section - C - Cables,Termination
5
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
NOTES :- The Quantities (mtrs) given in the BOQ are only approximate and
the contractor has to take actual measurements at site for the exact
quantities of materials required before purchase of materials required for
the work.
Cable:
Supply and laying in existing masonry cable duct or on surface of the column /
wall or in existing cable tray or along the truss of PVC insulated,XLPE,, 1.1 KV
grade armoured, MV cable of the following sizes as required, generally
conforming to IS:1554/Part-I/1970
Section - D - Wiring
6
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
Wiring for Single Control Light Point with 2 x 1.5 sq. mm, FRLS insulated
Stranded Copper Conductor Cable along with 1 x 1.0 sq. mm. FRLS PVC
insulated Stranded copper conductor cable as earth wire in recessed/surface
MS conduit including providing and fixing Galvanised / Cadmium plated MS
switch box, 6A Single Way modular type Switch on modular plate and making
necessary connections etc. complete as required as per specification.
75 pts
Wiring for Wall Mounted fan Point with 2 x 1.5sq. mm. FRLS PVC insulated
Stranded Copper Conductor Cable along with 1 x 1.0 sq. mm. FRLS PVC
insulated Stranded copper conductor cable as earth wire in recessed/surface
MS conduit including providing and fixing Galvanised / Cadmium plated MS
Switch Box, 6A modular type switch (along with other switches), 6 A 3 Pin
modular type socket outlet with 6A plug top in a GI /MS plated cadmium box on
modular plate near the exhaust fan and making necessary connections etc.,
complete as required as per specification.
14 pts
Wiring for exhaust fan Point with 2 x 1.5sq. mm. FRLS PVC insulated
Stranded Copper Conductor Cable along with 1 x 1.0 sq. mm. FRLS PVC
insulated Stranded copper conductor cable as earth wire in recessed/surface
MS conduit including providing and fixing Galvanised / Cadmium plated MS
Switch Box, 6A modular type switch (along with other switches), 6 A 3 Pin
modular type socket outlet with 6A plug top in a GI /MS plated cadmium box on
modular plate near the exhaust fan and making necessary connections etc.,
complete as required as per specification.
6 Pts
7
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
Wiring for circuit /power / sub main/DG power, etc with following sizes of
FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS
PVC insulated Stranded Cu. Conductor Cable as earth wire in Recessed /
Surface Suitable MS/PVC Conduit including making connection etc., as per
specification.
25 nos
Supply and fixing Modular type combined switch type socket 32A with suitable
metal enclosure and front plate.(For A/c) 20 nos
Supplying, erecting, connecting and commissioning 3 x 5Amps SWITCH Socket
in manufacturer's PVC enclosure with necessary accessories (For Workstation)
38 Nos
Supplying, and fixing 15 AMPS Switch socket for OHP CONTROL IN THE
TABLE of Manufacturer's MS mounting box fixed flush with the wall/ partitions
with necessaryaccessories 2 Nos
Supplying, erecting, connecting and commissioning 2 x 5/15Amps SWITCH
Socket in manufacturer's PVC enclosure with necessary accessories.(General
Purpose)
55 nos
Supplying, erecting, connecting and commissioning 1 x 5Amps Socket with
2nos of Switch in manufacturer's PVC enclosure with necessary accessories.
(For Lab Board)
94 no
8
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
Supplying, erecting, connecting and commissioning 2 x 5Amps and 1 x
5/15Amps SWITCH Socket in manufacturer's PVC enclosure with necessary
accessories.(For Stage in Seminar Hall)
1 no
Section - E - Earthing , Communication
Providing and fixing following sizes of copper wire on surface or in
recess for connections etc. as required.
a)8 SWG Copper 200 mtrs
b)Providing and fixing 40 mm x 6 mm GI strip on surface or in recess for
connections etc. as required. QRO Mts
c)Providing and fixing 25 mm x 6 mm GI strip on surface or in recess for
connections etc. as required. QRO Mts
Communication
Conduits
Supply and laying following sizes of PVC conduits in the floors, ceiling or
through partitions with all accessories like bends, couplers, pullwire etc
including cutting the flooring and making it good after installation
9
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
10
M/s. SRM DENTAL - ORAL PATHOLOGY LAB
SUMMARY SHEET
1
M/s.SRM DENTAL - ORAL PATHOLOGHY LAB
SCHEDULE OF QUANTITIES FOR ELECTRICAL WORK
Section - A - LT PANEL
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
Note:LT panels,Light Fitting,UPS System will be suppiled from client
1. ALL Panel shall be made out of 14 /16 SWG CRCA sheet steel with CNC
punched.
2. The panel shall be provided with Aluminium earth bus bars of at least one
third capacity of the phase bar rating along with the entire length of the panel
and cost of the same shall be included in cost of the panel.However the
minimum size of the bar shall be 25 x 6 mm Cu. Flat only
3. The bus bar chamber size shall not be less than 300 mm in all sub switch
boards.
4. The cable chamber width shall not be less than 300 mm in case of all floor
mounted boards. In respect of wall mounted boards 250 mm width is
acceptable.
5. All MCCBs / FSUs shall be provided with front drive mechanism with
necessary door interlock.
6. MCCBs with more than 125 A rating shall be provided with spreaders and
terminal shrouds.
7. The panel shall be powder coated finish with RAL 7035 Shade.
8. All MCCBs are Ics = 100% Icu only.
KA Rating
up to 100A - 25KA
125A to 315A - 36 KA
400 to - 1250A - 50KA
POWER PANEL(TOP/BOTTOM ENTRY)
Supply ,Installation, Testing and Commissioning of Medium Voltage floor
mounting Cubicle Type Distribution Board suitable for 415 V, 3 Phase, 50 Hz
Power Distribution System with the following mounting complete as per
specifications attached.
2
INCOMER
100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 36 kA
Short Circuit Rating with Adjustable Thermal O/L and Magnetic S/C Protection
- 2Nos
OUTGOINGS:
80 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA
Short Circuit Rating with Adjustable Thermal O/L and Magnetic S/C Protection
- 6Nos
BUSBAR:
1 Set of 250 A, TP& N Aluminium Bus bar Chamber for the entire length of the
MV Panel with 0.8 A/mm2 Current Density. All the Vertical and horizontal Bus
bar shall be of same size and rating.
1 Set of R Y B LED Type Indicating Lamps with Control MCB and MFM 1 NO 120110 3500 120110 3500
EXISTING PANEL
Removing of already exisiting SFU and replacing with 100 Amps TP&N Fixed
Type SFU unit to the exisiting panel 2 NO 4100 350 8200 700
Removing of already exisiting SFU and replacing with 200 Amps TP&N Fixed
Type SFU unit to the exisiting panel
Qro NO 7500 450
3
Section - B - Distribution Board,Light Fitting,Fans
I Distribution Board
Supply, Installation, Testing and Commissioning of the following TPN MCB
distribution boards shall be designed for metal door type IP 42 protection, with
MCB / Isolator / RCCB / RCBO as incomer and suitable space provision for
phase selector switch and illuminated piano switch. The distribution boards
shall be designed for 415V,3Ph,50Hz, 4 wire AC system sheet steel, dust and
vermin proof suitable for wall mounting type (recessed) designed and fabricated
made up of Standard reputed make manufacture. The DB shall have suitable
neutral and earth terminal block to facilitate easy termination of wires. All wires
inside the DB shall be terminated using copper crimping socket. The DB shall
be suitable body earthing terminals with powder coated painting, danger board,
sign writing including minor civil works (recessed system) etc as required.
4
Light Fittings,Fans
a)Recess Mounted LED Fitting 132 nos 2950 130 389400 17160
bRecess Mounted Down Lighter (18W Led Fitting) 58 nos 950 100 55100 5800
c) 1 x 40 W Tube Light Fitting 4 nos 600 130 2400 520
d)Surface Mounted T5 LED Fitting 36w( For Board Light) 90 nos 2650 100 238500 9000
e)Surface Mounted T5 LED Fitting 36w( For Board Light) 2 nos 1800 100 3600 200
f)Recess Mounted Down Lighter( Model Coin 111 AC or Equivalent) 2 nos 2800 100 5600 200
g)Doctor Board Display Light 1 nos 4800 100 4800 100
h)Track Led Lighting qro nos 100000 600
i)Hanging Light Fitting qro nos 18000 150
Fans
a)1200mm Sweep Ceiling Fan necessary accessories 75 nos 1800 180 135000 13500
b)305mm Sweep, Heavy Duty Industrial Type Exhaust Fan 6 nos 1500 150 9000 900
c)Wall Mounted Fan 14 nos 2200 150 30800 2100
Section - C - Cables,Termination
NOTES :- The Quantities (mtrs) given in the BOQ are only approximate and
the contractor has to take actual measurements at site for the exact
quantities of materials required before purchase of materials required for
the work.
5
Cable:
Supply and laying in existing masonry cable duct or on surface of the column /
wall or in existing cable tray or along the truss of PVC insulated,XLPE,, 1.1 KV
grade armoured, MV cable of the following sizes as required, generally
conforming to IS:1554/Part-I/1970
Section - D - Wiring
6
Wiring for Single Control Light Point with 2 x 1.5 sq. mm, FRLS insulated
Stranded Copper Conductor Cable along with 1 x 1.0 sq. mm. FRLS PVC
insulated Stranded copper conductor cable as earth wire in recessed/surface
MS conduit including providing and fixing Galvanised / Cadmium plated MS
switch box, 6A Single Way modular type Switch on modular plate and making
necessary connections etc. complete as required as per specification.
a)One Light Controlled by One Switch. 275 Each 950 210 261250 57750
b)Two Light Controlled by One Switch. QRO Each 850 210
c)Three Light Controlled by One Switch. QRO Each 800 210
Wiring for fan Point with 2 x 1.5sq. mm. FRLS PVC insulated Stranded Copper
Conductor Cable along with 1 x 1.0 sq. mm. FRLS PVC insulated Stranded
copper conductor cable as earth wire in recessed/surface MS conduit including
providing and fixing Galvanised / Cadmium plated MS Switch Box, 6A modular
type switch and 300 W electronic regulator on modular plate and making
necessary connections etc. complete as required as per specification.
7
Wiring for circuit /power / sub main/DG power, etc with following sizes of
FRLS PVC insulated Stranded Copper Conductor Cable along with FRLS
PVC insulated Stranded Cu. Conductor Cable as earth wire in Recessed /
Surface Suitable MS/PVC Conduit including making connection etc., as per
specification.
Supplying, and fixing 15 AMPS Switch socket for OHP CONTROL IN THE
TABLE of Manufacturer's MS mounting box fixed flush with the wall/ partitions 1250 260
with necessaryaccessories 2 Nos 2500 520
Supplying, erecting, connecting and commissioning 2 x 5/15Amps SWITCH
Socket in manufacturer's PVC enclosure with necessary accessories.(General 1100 240
Purpose)
55 nos 60500 13200
Supplying, erecting, connecting and commissioning 1 x 5Amps Socket with
2nos of Switch in manufacturer's PVC enclosure with necessary accessories.
(For Lab Board)
94 no 850 220 79900 20680
Supplying, erecting, connecting and commissioning 2 x 5Amps and 1 x
5/15Amps SWITCH Socket in manufacturer's PVC enclosure with necessary
accessories.(For Stage in Seminar Hall)
1 no 1300 260 1300 260
Section - E - Earthing , Communication
8
Providing and fixing following sizes of copper wire on surface or in
recess for connections etc. as required.
a)8 SWG Copper 200 mtrs 65 9 13000 1800
b)Providing and fixing 40 mm x 6 mm GI strip on surface or in recess for
connections etc. as required. 175 20
QRO Mts
c)Providing and fixing 25 mm x 6 mm GI strip on surface or in recess for
connections etc. as required. 100 17
QRO Mts
Communication
Conduits
Supply and laying following sizes of PVC conduits in the floors, ceiling or
through partitions with all accessories like bends, couplers, pullwire etc
including cutting the flooring and making it good after installation
1957655 267560
9
M/s. SRM DENTAL - ORAL PATHOLOGY LAB
SUMMARY SHEET
1
M/s.SRM DENTAL - ORAL PATHOLOGHY LAB
SCHEDULE OF QUANTITIES FOR ELECTRICAL WORK
Section - A - LT PANEL
SL. QTY UNIT UNIT PRICE TOTAL PRICE
DESCRITION
NO. SUPPLY ERECTION SUPPLY ERECTION
Note:LT panels,Light Fitting,UPS System will be suppiled from client
1. ALL Panel shall be made out of 14 /16 SWG CRCA sheet steel with CNC
punched.
2. The panel shall be provided with Aluminium earth bus bars of at least one
third capacity of the phase bar rating along with the entire length of the panel
and cost of the same shall be included in cost of the panel.However the
minimum size of the bar shall be 25 x 6 mm Cu. Flat only
3. The bus bar chamber size shall not be less than 300 mm in all sub switch
boards.
4. The cable chamber width shall not be less than 300 mm in case of all floor
mounted boards. In respect of wall mounted boards 250 mm width is
acceptable.
5. All MCCBs / FSUs shall be provided with front drive mechanism with
necessary door interlock.
6. MCCBs with more than 125 A rating shall be provided with spreaders and
terminal shrouds.
7. The panel shall be powder coated finish with RAL 7035 Shade.
8. All MCCBs are Ics = 100% Icu only.
KA Rating
up to 100A - 25KA
125A to 315A - 36 KA
400 to - 1250A - 50KA
POWER PANEL(TOP/BOTTOM ENTRY)
Supply ,Installation, Testing and Commissioning of Medium Voltage floor
mounting Cubicle Type Distribution Board suitable for 415 V, 3 Phase, 50 Hz
Power Distribution System with the following mounting complete as per
specifications attached.
2
SL. UNIT PRICE TOTAL PRICE
DESCRITION QTY UNIT
NO. SUPPLY ERECTION SUPPLY ERECTION
INCOMER
100 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 36 kA
Short Circuit Rating with Adjustable Thermal O/L and Magnetic S/C Protection
- 2Nos
OUTGOINGS:
80 Amps TP&N Fixed Type MCCB with Manual Closing Mechanism of 25 kA
Short Circuit Rating with Adjustable Thermal O/L and Magnetic S/C Protection
- 6Nos
BUSBAR:
1 Set of 250 A, TP& N Aluminium Bus bar Chamber for the entire length of the
MV Panel with 0.8 A/mm2 Current Density. All the Vertical and horizontal Bus
bar shall be of same size and rating.
1 Set of R Y B LED Type Indicating Lamps with Control MCB and MFM 1 NO 120110 3500 120110 3500
EXISTING PANEL
Removing of already exisiting SFU and replacing with 100 Amps TP&N Fixed
Type SFU unit to the exisiting panel 2 NO 4100 350 8200 700
Removing of already exisiting SFU and replacing with 200 Amps TP&N Fixed
Type SFU unit to the exisiting panel
Qro NO 7500 450
3
SL. UNIT PRICE TOTAL PRICE
DESCRITION QTY UNIT
NO. SUPPLY ERECTION SUPPLY ERECTION
Section - B - Distribution Board,Light Fitting,Fans
I Distribution Board
Supply, Installation, Testing and Commissioning of the following TPN MCB
distribution boards shall be designed for metal door type IP 42 protection, with
MCB / Isolator / RCCB / RCBO as incomer and suitable space provision for
phase selector switch and illuminated piano switch. The distribution boards
shall be designed for 415V,3Ph,50Hz, 4 wire AC system sheet steel, dust and
vermin proof suitable for wall mounting type (recessed) designed and fabricated
made up of Standard reputed make manufacture. The DB shall have suitable
neutral and earth terminal block to facilitate easy termination of wires. All wires
inside the DB shall be terminated using copper crimping socket. The DB shall
be suitable body earthing terminals with powder coated painting, danger board,
sign writing including minor civil works (recessed system) etc as required.
4
SUB 'SECTION - 'B' 22500 3000
5
SL. UNIT PRICE TOTAL PRICE
DESCRITION QTY UNIT
NO. SUPPLY ERECTION SUPPLY ERECTION
Light Fittings,Fans
a)Recess Mounted LED Fitting 132 nos 2950 130 389400 17160
bRecess Mounted Down Lighter (18W Led Fitting) 58 nos 950 100 55100 5800
c) 1 x 40 W Tube Light Fitting 4 nos 600 130 2400 520
d)Surface Mounted T5 LED Fitting 36w( For Board Light) 90 nos 2650 100 238500 9000
e)Surface Mounted T5 LED Fitting 36w( For Board Light) 2 nos 1800 100 5300 200
f)Recess Mounted Down Lighter( Model Coin 111 AC or Equivalent) 2 nos 2800 100 5600 200
g)Doctor Board Display Light 1 nos 4800 100 4800 100
h)Track Led Lighting qro nos 100000 600
i)Hanging Light Fitting qro nos 18000 150
Fans
a)1200mm Sweep Ceiling Fan necessary accessories 75 nos 1800 180 135000 13500
b)305mm Sweep, Heavy Duty Industrial Type Exhaust Fan 6 nos 1500 150 9000 900
c)Wall Mounted Fan 14 nos 2200 150 30800 2100
6
SL. UNIT PRICE TOTAL PRICE
DESCRITION QTY UNIT
NO. SUPPLY ERECTION SUPPLY ERECTION
Section - C - Cables,Termination
NOTES :- The Quantities (mtrs) given in the BOQ are only approximate and
the contractor has to take actual measurements at site for the exact
quantities of materials required before purchase of materials required for
the work.
Cable:
Supply and laying in existing masonry cable duct or on surface of the column /
wall or in existing cable tray or along the truss of PVC insulated,XLPE,, 1.1 KV
grade armoured, MV cable of the following sizes as required, generally
conforming to IS:1554/Part-I/1970
7
TOTAL FOR 'SECTION - 'C' 59250 13460
Section - D - Wiring
Wiring for Single Control Light Point with 2 x 1.5 sq. mm, FRLS insulated
Stranded Copper Conductor Cable along with 1 x 1.0 sq. mm. FRLS PVC
insulated Stranded copper conductor cable as earth wire in recessed/surface
MS conduit including providing and fixing Galvanised / Cadmium plated MS
switch box, 6A Single Way modular type Switch on modular plate and making
necessary connections etc. complete as required as per specification.
a)One Light Controlled by One Switch. 275 Each 950 210 261250 57750
b)Two Light Controlled by One Switch. QRO Each 850 210
c)Three Light Controlled by One Switch. QRO Each 800 210
Wiring for fan Point with 2 x 1.5sq. mm. FRLS PVC insulated Stranded Copper
Conductor Cable along with 1 x 1.0 sq. mm. FRLS PVC insulated Stranded
copper conductor cable as earth wire in recessed/surface MS conduit including
providing and fixing Galvanised / Cadmium plated MS Switch Box, 6A modular
type switch and 300 W electronic regulator on modular plate and making
necessary connections etc. complete as required as per specification.
8
Wiring for exhaust fan Point with 2 x 1.5sq. mm. FRLS PVC insulated
Stranded Copper Conductor Cable along with 1 x 1.0 sq. mm. FRLS PVC
insulated Stranded copper conductor cable as earth wire in recessed/surface
MS conduit including providing and fixing Galvanised / Cadmium plated MS
Switch Box, 6A modular type switch (along with other switches), 6 A 3 Pin
modular type socket outlet with 6A plug top in a GI /MS plated cadmium box on
modular plate near the exhaust fan and making necessary connections etc.,
complete as required as per specification.
Supplying, and fixing 15 AMPS Switch socket for OHP CONTROL IN THE
TABLE of Manufacturer's MS mounting box fixed flush with the wall/ partitions 1250 260
with necessaryaccessories 2 Nos 2500 520
9
Supplying, erecting, connecting and commissioning 2 x 5/15Amps SWITCH
Socket in manufacturer's PVC enclosure with necessary accessories.(General 1100 240
Purpose)
55 nos 60500 13200
Supplying, erecting, connecting and commissioning 1 x 5Amps Socket with
2nos of Switch in manufacturer's PVC enclosure with necessary accessories.
(For Lab Board)
94 no 850 220 79900 20680
Supplying, erecting, connecting and commissioning 2 x 5Amps and 1 x
5/15Amps SWITCH Socket in manufacturer's PVC enclosure with necessary
accessories.(For Stage in Seminar Hall)
1 no 1300 260 1300 260
10
TOTAL FOR 'SECTION - 'E' 47195 10780
11
37000
2500
3800
2000
2500
32350
1080
12000
4500
224
97954
6500
104454
15668.1
120122.1