Table 1.

1:Rebound Hammer Test Results of Columns of Building OFFIC

RE
RCC MEMBER STRUCTURE
R1

BUILDING-OFFICE
Gr.Flr.Column-01 (T) 52
Gr.Flr.Column-01 (B) 44
Gr.Flr.Column-02 (T) 44
Gr.Flr.Column-02 (B) 41
Gr.Flr.Column-03 (T) 60
Gr.Flr.Column-03 (B) 54
Gr.Flr.Column-04 (T) 52
Gr.Flr.Column-04 (B) 51
Gr.Flr.Column-05 (T) 38
Gr.Flr.Column-05 (B) 42
Gr.Flr.Column-06 (T) 44
Gr.Flr.Column-06 (B) 44
Gr.Flr.Column-07 (T) 51
Gr.Flr.Column-07 (B) 54
1st Flr.Column-08 (T) 41
1st Flr.Column-08 (B) 41
1 Flr.Column-09 (T)
st
41
1st Flr.Column-09 (B) 40
Mean
Standard Deviation

Table 1.2:Rebound Hammer Test Results of Beams of Building OFFICE


RE
RCC MEMBER STRUCTURE
R1

BUILDING-OFFICE
Gr.Flr.Beam-01 (E) 46
Gr.Flr.Beam-01 (W) 46
Gr.Flr.Beam-02 (N) 44
Gr.Flr.Beam-02 (S) 44
Gr.Flr.Beam-03 (E) 40
Gr.Flr.Beam-03 (W) 44
Gr.Flr.Beam-04 (E) 46
Gr.Flr.Beam-04 (W) 40
1st Flr.Beam-05 (E) 36
1st Flr.Beam-05 (W) 36
1st Flr.Beam-06 (E) 34
1st Flr.Beam-06 (W) 34
1st Flr.Beam-07 (E) 20
1st Flr.Beam-07 (W) 22
Mean
Standard Deviation

Table 1.3:Rebound Hammer Test Results of Slabs of Building OFFICE,I

RE
RCC MEMBER STRUCTURE
R1

BUILDING-OFFICE
Gr.Flr.Slab-01 (N) 44
Gr.Flr.Slab-01 (S) 44
Gr.Flr.Slab-02 (N) 48
Gr.Flr.Slab-02 (S) 44
Gr.Flr.Slab-03 (N) 52
Gr.Flr.Slab-03 (S) 56
1st Flr.Slab-04 (N) 46
1st Flr.Slab-04 (S) 46
1st Flr.Slab-05 (N) 36
1st Flr.Slab-05 (S) 40
1st Flr.Slab-06 (N) 36
1st Flr.Slab-06 (S) 36
Mean
Standard Deviation

Table 1.4:Ultrasonic Pulse Velocity Test Results of Columns of Building

ULTRASONIC PULSE VELOCITY TE


RCC MEMBER STRUCTURE
RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-OFFICE
Gr.Flr.Column-01* 500
Gr.Flr.Column-02 300
Gr.Flr.Column-03 300
Gr.Flr.Column-04* 500
Gr.Flr.Column-05 300
Gr.Flr.Column-06 300
Gr.Flr.Column-07* 300
1st Flr.Column-08 300
1 Flr.Column-09*
st
500
Mean
Standard Deviation
(*Direct Method,Indirect Method)

Table 1.5:Ultrasonic Pulse Velocity Test Results of Beams of Building O

ULTRASONIC PULSE VELOCITY TE


RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-OFFICE
Gr.Flr.Beam-01 230
Gr.Flr.Beam-02* 220
Gr.Flr.Beam-03 230
Gr.Flr.Beam-04 230
1st Flr.Beam-05 230
1st Flr.Beam-06 230
1 Flr.Beam-07
st Loosed
Mean
Standard Deviation
(Direct Method,*Indirect Method)

Table 1.6:Ultrasonic Pulse Velocity Test Results of Slabs of Building OF

ULTRASONIC PULSE VELOCITY TE


RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-OFFICE
Gr.Flr.Slab-01 280
Gr.Flr.Slab-02 300
Gr.Flr.Slab-03 290
1st Flr.Slab-04 290
1st Flr.Slab-05 260
1st Flr.Slab-06 250
Mean
Standard Deviation
(*Direct Method,Indirect Method)

Table 1.7.Carbonation Test results of Columns of Building OFFICE,IOC

CARBONATION EFFECT FROM THE


RCC MEMBER STRUCTURE
SURFACE* (mm)

BUILDING-OFFICE
Gr.Flr.Column-01 10
Gr.Flr.Column-02 10
Gr.Flr.Column-03 10
Gr.Flr.Column-04 10
Gr.Flr.Column-05 5
Gr.Flr.Column-06 20
Gr.Flr.Column-07 20
1st Flr.Column-08 20
1st Flr.Column-09 20
(excluding surface plaster)
Columns of Building OFFICE,IOCL,CIP TURBHE PLANT.

REBOUND HAMMER TEST

AVERAGE COMP. STRENGTH


R2 R3 R4
READING (MPa)

BUILDING-OFFICE
50 48 50 50 59
50 52 48 49 57
41 41 44 43 46
42 46 40 42 44
57 52 60 57 >69
52 50 54 53 65
51 54 54 53 65
54 56 52 53 65
42 41 41 41 42
44 40 42 42 44
46 40 46 44 48
42 48 44 45 50
46 54 54 51 61
52 50 48 51 61
40 41 43 41 42
44 46 42 43 46
38 38 37 39 39
36 40 38 39 39
Mean 51.35
Standard Deviation 9.66

Beams of Building OFFICE,IOCL,CIP TURBHE PLANT.


REBOUND HAMMER TEST

AVERAGE COMP. STRENGTH


R2 R3 R4
READING (MPa)

BUILDING-OFFICE
40 48 44 45 50
42 44 50 46 52
42 48 46 45 50
40 42 46 43 46
46 44 38 42 44
40 48 44 44 48
40 48 44 45 50
42 42 40 41 42
32 30 34 33 28
34 38 32 35 32
32 40 36 36 33
36 34 36 35 32
24 26 24 24 15
24 22 20 22 12
Mean 38.14
Standard Deviation 13.14

Slabs of Building OFFICE,IOCL,CIP TURBHE PLANT.

REBOUND HAMMER TEST

AVERAGE COMP. STRENGTH


R2 R3 R4
READING (MPa)

BUILDING-OFFICE
48 42 48 46 45
46 44 42 44 41
46 40 42 44 41
48 46 44 46 45
56 54 50 53 60
58 52 54 55 63
38 40 44 42 37
40 44 42 43 39
40 42 44 41 35
46 44 42 43 39
42 40 38 39 32
40 38 36 38 30
Mean 42.25
Standard Deviation 10.09

ults of Columns of Building OFFICE,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST


AVERAGE VELOCITY
TIME (µ sec)
(Km/Sec)

-OFFICE
127.1 3.9
139.2 2.6
89.9 4.0
140.8 3.6
330.0 1.1 Rough Surface
161.5 2.2
99.4 3.0
150.3 2.4
177.4 2.8
2.85
0.92
direct Method)

ults of Beams of Building OFFICE,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST

AVERAGE VELOCITY
TIME (µ sec)
(Km/Sec)
-OFFICE
109.1 2.1
151.5 1.7
76.8 3.0
72.5 3.2
120.3 1.9
144.3 1.6
Loosed
2.25
0.67
direct Method)

ults of Slabs of Building OFFICE,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST


AVERAGE VELOCITY
TIME (µ sec)
(Km/Sec)

-OFFICE
144.8 2.32
178.2 2.02
81.3 4.28
154.8 2.25
178.1 1.75
272.4 1.10
2.29
1.07
direct Method)

ns of Building OFFICE,IOCL,CIP TURBHE PLANT.

NATION EFFECT FROM THE


SURFACE* (mm)

10
10
10
10
5
20
20
20
20
Table 2.1:Rebound Hammer Test Results of Columns of Building R&D,

REBO
RCC MEMBER STRUCTURE
R1

BUILDING-R&D
Gr.Flr.Column-01 (T) 44
Gr.Flr.Column-01 (B) 48
Gr.Flr.Column-02 (T) 46
Gr.Flr.Column-02 (B) 48
Gr.Flr.Column-03 (T) 51
Gr.Flr.Column-03 (B) 50
Gr.Flr.Column-04 (T) 46
Gr.Flr.Column-04 (B) 50
Gr.Flr.Column-05 (T) 48
Gr.Flr.Column-05 (B) 41
Mean
Standard Deviation

Table 2.2:Rebound Hammer Test Results of Beams of Building R&D,IO


REBO
RCC MEMBER STRUCTURE
R1

BUILDING-R&D
Gr.Flr.Beam-01 (E) 38
Gr.Flr.Beam-01 (W) 46
Gr.Flr.Beam-02 (E) 40
Gr.Flr.Beam-02 (W) 36
Gr.Flr.Beam-03 (E) 36
Gr.Flr.Beam-03 (W) 44
Gr.Flr.Beam-04 (E) 50
Gr.Flr.Beam-04 (W) 52
Mean
Standard Deviation

Table 2.3:Rebound Hammer Test Results of Slabs of Building R&D,IOC


REBO
RCC MEMBER STRUCTURE
R1

BUILDING-R&D
Gr.Flr.Slab-01 (N) 50
Gr.Flr.Slab-01 (S) 48
Gr.Flr.Slab-02 (N) 46
Gr.Flr.Slab-02 (S) 44
Gr.Flr.Slab-03 (N) 50
Gr.Flr.Slab-03 (S) 54
Gr.Flr.Slab-04 (N) 56
Gr.Flr.Slab-04 (S) 58
Mean
Standard Deviation

Table 2.4:Ultrasonic Pulse Velocity Test Results of Columns of Building

ULTRASONIC PULSE VELOCITY TES


RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-R&D
Gr.Flr.Column-01 300
Gr.Flr.Column-02 300
Gr.Flr.Column-03 300
Gr.Flr.Column-04 300
Gr.Flr.Column-05 300
Mean
Standard Deviation
(*Direct Method,Indirect Method)

Table 2.5:Ultrasonic Pulse Velocity Test Results of Beams of Building R

ULTRASONIC PULSE VELOCITY TES


RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-R&D
Gr.Flr.Beam-01 230
Gr.Flr.Beam-02 230
Gr.Flr.Beam-03 Hallow
Gr.Flr.Beam-04 230
Mean
Standard Deviation
(Direct Method,*Indirect Method)

Table 2.6:Ultrasonic Pulse Velocity Test Results of Slabs of Building R&

ULTRASONIC PULSE VELOCITY TES


RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-R&D
Gr.Flr.Slab-01 300
Gr.Flr.Slab-02 230
Gr.Flr.Slab-03 300
Gr.Flr.Slab-04 300
Mean
Standard Deviation
(*Direct Method,Indirect Method)

Table 2.7:Corrosion Analysis Test Results of Beam and Slab of Building

RCC MEMBER STRUCTURE HALF CELL POTENTIAL -mV

BUILDING-R&D
148
Gr.Flr.Beam-01 142
130
88
Gr.Flr.Slab-05 92
102
Mean
Standard Deviation
(excluding surface plaster)

Table 2.8.Carbonation Test results of Columns of Building R&D,IOCL,C

CARBONATION EFFECT FROM THE


RCC MEMBER STRUCTURE
SURFACE* (mm)
CARBONATION EFFECT FROM THE
RCC MEMBER STRUCTURE
SURFACE* (mm)

BUILDING-R&D
Gr.Flr.Column-01 25
Gr.Flr.Column-02 20
Gr.Flr.Column-03 20
Gr.Flr.Column-04 10
Gr.Flr.Column-05 20
(excluding surface plaster)
Columns of Building R&D,IOCL,CIP TURBHE PLANT.

REBOUND HAMMER TEST

COMP.
AVERAGE
R2 R3 R4 STRENGTH
READING
(MPa)
BUILDING-R&D
45 49 43 45 50
42 44 48 46 52
41 42 42 43 46
44 42 46 45 50
46 54 52 51 61
48 46 50 49 57
42 50 46 46 52
48 46 42 47 54
46 44 40 45 50
46 42 44 43 46
Mean 51.80
Standard Deviation 4.64

Beams of Building R&D,IOCL,CIP TURBHE PLANT.


REBOUND HAMMER TEST
COMP.
AVERAGE
R2 R3 R4 STRENGTH
READING
(MPa)
BUILDING-R&D
42 46 42 42 44
44 46 40 44 48
38 42 40 40 40
38 44 42 40 40
42 44 40 41 42
46 40 38 42 44
48 48 46 48 55
50 50 46 50 59
Mean 46.86
Standard Deviation 7.54

Slabs of Building R&D,IOCL,CIP TURBHE PLANT.


REBOUND HAMMER TEST
COMP.
AVERAGE
R2 R3 R4 STRENGTH
READING
(MPa)
BUILDING-R&D
48 46 42 47 47
50 42 44 46 45
52 50 48 49 51
48 50 48 48 49
54 52 56 53 60
56 52 50 53 60
60 62 54 58 >63
56 54 52 55 63
Mean 53.57
Standard Deviation 7.25

ults of Columns of Building R&D,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST

AVERAGE
TIME (µ sec) VELOCITY
(Km/Sec)
-R&D
161.0 2.2
100.2 3.6
113.5 3.2
110.1 3.3
279.9 1.3
2.71
0.94
rect Method)

ults of Beams of Building R&D,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST

AVERAGE
TIME (µ sec) VELOCITY
(Km/Sec)
-R&D
162.1 1.4 Hallow
74.2 3.1
Hallow
71.0 3.2
2.59
1.01
rect Method)

ults of Slabs of Building R&D,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST


AVERAGE
TIME (µ sec) VELOCITY
(Km/Sec)
-R&D
136.1 2.65
91.7 3.01
136.7 2.63
98.0 3.67
2.99
0.49
rect Method)

f Beam and Slab of Building R&D,IOCL,CIP TURBHE PLANT.


AVERAGE HALF CELL
HALF CELL POTENTIAL -mV
POTENTIAL -mV
UILDING-R&D
132 145 142
138 138 139
142 130 134
84 78 83
133 132 119
125 130 119
122.7
viation 21.6
uding surface plaster)

ns of Building R&D,IOCL,CIP TURBHE PLANT.

NATION EFFECT FROM THE


SURFACE* (mm)
NATION EFFECT FROM THE
SURFACE* (mm)

25
20
20
10
20
Table 3.1:Rebound Hammer Test Results of Columns of Building OIL D

REB
RCC MEMBER STRUCTURE
R1

BUILDING-OIL DISPENSARY U
Gr.Flr.Column-01 (T) 24
Gr.Flr.Column-01 (B) 24
Gr.Flr.Column-02 (E) 38
Gr.Flr.Column-02 (W) 48
Gr.Flr.Column-03 (T) 59
Gr.Flr.Column-03 (B) 58
Gr.Flr.Column-04 (N) 51
Gr.Flr.Column-04 (S) 52
Gr.Flr.Column-05 (T) 44
Gr.Flr.Column-05 (B) 42
Gr.Flr.Column-06 (T) 40
Gr.Flr.Column-06 (B) 44
Gr.Flr.Column-07 (T) 55
Gr.Flr.Column-07 (B) 48
Gr.Flr.Column-08 (T) 43
Gr.Flr.Column-08 (B) 41
Gr.Flr.Column-09 (T) 36
Gr.Flr.Column-09 (B) 37
1st Flr.Column-10 (T) 36
1st Flr.Column-10 (B) 38
1st Flr.Column-11 (T) 26
1st Flr.Column-11 (B) 28
Mean
Standard Deviation

Table 3.2:Rebound Hammer Test Results of Beams of Building OIL DIS


REB
RCC MEMBER STRUCTURE
R1

BUILDING-OIL DISPENSARY U
Gr.Flr.Beam-01 (N) 30
Gr.Flr.Beam-01 (S) 30
Gr.Flr.Beam-02 (N) 40
Gr.Flr.Beam-02 (S) 38
Gr.Flr.Beam-03 (N) 34
Gr.Flr.Beam-03 (S) 38
1st Flr.Beam-04 (N) 28
1st Flr.Beam-04 (S) 32
1st Flr.Beam-05 (N) 46
1st Flr.Beam-05 (S) 44
1st Flr.Beam-06 (N) 32
1st Flr.Beam-06 (S) 38
1st Flr.Beam-07 (N) 36
1st Flr.Beam-07 (S) 36
Mean
Standard Deviation

Table 3.3:Rebound Hammer Test Results of Slabs of Building OIL DISP


REB
RCC MEMBER STRUCTURE
R1

BUILDING-OIL DISPENSARY U
Gr.Flr.Slab-01 (E) 40
Gr.Flr.Slab-01 (W) 44
Gr.Flr.Slab-02 (E) 38
Gr.Flr.Slab-02 (W) 40
Gr.Flr.Slab-03 (E) 44
Gr.Flr.Slab-03 (W) 42
1st Flr.Slab-04 (E) 42
1st Flr.Slab-04 (W) 42
1st Flr.Slab-05 (E) 44
1st Flr.Slab-05 (W) 42
1st Flr.Slab-06 (E) 40
1st Flr.Slab-06 (W) 40
1st Flr.Slab-07 (N) 34
1st Flr.Slab-07 (S) 40
Mean
Standard Deviation
Table 3.4:Ultrasonic Pulse Velocity Test Results of Columns of Building

ULTRASONIC PULSE VELOCITY TE


RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-OIL DISPENSARY UNIT SHOP


Gr.Flr.Column-01 Cracked
Gr.Flr.Column-02* 300
Gr.Flr.Column-03 300
Gr.Flr.Column-04* 300
Gr.Flr.Column-05 300
Gr.Flr.Column-06 Loosed
Gr.Flr.Column-07 300
Gr.Flr.Column-08* 300
Gr.Flr.Column-09 Rough Surface
1st Flr.Column-10 300
1st Flr.Column-11 Hallow
Mean
Standard Deviation
(*Direct Method,Indirect Method)

Table 3.5:Ultrasonic Pulse Velocity Test Results of Beams of Building O

ULTRASONIC PULSE VELOCITY TE


RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-OIL DISPENSARY UNIT SHOP


Gr.Flr.Beam-01 230
Gr.Flr.Beam-02 230
Gr.Flr.Beam-03 230
1st Flr.Beam-04 230
1st Flr.Beam-05 230
1st Flr.Beam-06 230
1 Flr.Beam-07*
st
300
Mean
Standard Deviation
(Direct Method,*Indirect Method)
Table 3.6:Ultrasonic Pulse Velocity Test Results of Slabs of Building OI

ULTRASONIC PULSE VELOCITY TE


RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-OIL DISPENSARY UNIT SHOP


Gr.Flr.Slab-01 Loosed
Gr.Flr.Slab-02 280
Gr.Flr.Slab-03 250
1st Flr.Slab-04 250
1st Flr.Slab-05 280
1st Flr.Slab-06 200
1 Flr.Slab-07
st
290
Mean
Standard Deviation
(*Direct Method,Indirect Method)

Table 3.7:Corrosion Analysis Test Results of Columns and Beam of Buil

RCC MEMBER STRUCTURE HALF CELL POTENTIAL -mV

BUILDING-OIL DISPENSARY UNIT SHOP


186
Gr.Flr.Column-01 120
182
251
Gr.Flr.Column-05 257
232
174
1st Flr.Beam-07 157
189
Mean
Standard Deviation
(excluding surface plaster)

Table 3.8.Carbonation Test results of Columns of Building OIL DISPEN

CARBONATION EFFECT FROM THE


RCC MEMBER STRUCTURE
SURFACE* (mm)
BUILDING-OIL DISPENSARY UNIT SHOP
Gr.Flr.Column-01 >30
Gr.Flr.Column-02 25
Gr.Flr.Column-03 15
Gr.Flr.Column-04 >30
Gr.Flr.Column-05 >30
Gr.Flr.Column-06 >30
Gr.Flr.Column-07 20
Gr.Flr.Column-08 >30
Gr.Flr.Column-09 >30
1st Flr.Column-10 >30
1st Flr.Column-11 >30
(excluding surface plaster)
Columns of Building OIL DISPENSARY UNIT SHOP,IOCL,CIP TURBHE PLANT.

REBOUND HAMMER TEST

COMP.
AVERAGE
R2 R3 R4 STRENGTH
READING
(MPa)
ILDING-OIL DISPENSARY UNIT SHOP
22 22 19 22 12
26 24 24 25 16
40 37 40 39 39
41 40 42 43 46
56 56 56 57 >69
54 52 56 55 69
54 49 50 51 61
54 50 52 52 63
41 48 49 46 52
46 44 47 45 50
41 44 42 42 44
42 38 44 42 44
51 49 48 51 61
50 52 50 50 59
45 42 48 45 50
44 46 42 43 46
34 35 36 35 32
35 36 40 37 35
36 34 39 36 33
40 36 34 37 35
26 28 30 28 20
30 26 28 28 20
Mean 42.24
Standard Deviation 16.25

Beams of Building OIL DISPENSARY UNIT SHOP,IOCL,CIP TURBHE PLANT.


REBOUND HAMMER TEST
COMP.
AVERAGE
R2 R3 R4 STRENGTH
READING
(MPa)
ILDING-OIL DISPENSARY UNIT SHOP
32 34 30 32 26
28 36 32 32 26
38 36 40 39 39
36 38 36 37 35
34 36 32 34 30
36 36 30 35 32
30 32 30 30 23
26 28 26 28 20
42 40 46 44 48
42 40 44 43 46
40 38 32 36 33
32 36 34 35 32
36 34 34 35 32
38 30 34 35 32
Mean 32.92
Standard Deviation 7.98

Slabs of Building OIL DISPENSARY UNIT SHOP,IOCL,CIP TURBHE PLANT.


REBOUND HAMMER TEST
COMP.
AVERAGE
R2 R3 R4 STRENGTH
READING
(MPa)
ILDING-OIL DISPENSARY UNIT SHOP
38 40 36 39 32
42 40 38 41 35
42 42 44 42 37
42 40 40 41 35
46 48 44 46 45
42 46 45 44 41
44 46 40 43 39
44 42 43 43 39
38 40 42 41 35
40 40 44 42 37
42 38 36 39 32
40 40 38 40 34
38 30 34 34 23
32 36 34 36 26
Mean 35.00
Standard Deviation 5.68
ults of Columns of Building OIL DISPENSARY UNIT SHOP,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST

AVERAGE VELOCITY
TIME (µ sec)
(Km/Sec)

NSARY UNIT SHOP


Cracked
109.4 2.7
99.5 3.6
88.9 3.4
230.0 1.3 Cracked
Loosed
99.5 3.6
124.1 2.4
Rough Surface
283.9 1.1
Hallow
2.4
1.05
direct Method)

ults of Beams of Building OIL DISPENSARY UNIT SHOP,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST


AVERAGE VELOCITY
TIME (µ sec)
(Km/Sec)
NSARY UNIT SHOP
92.5 2.5
92.3 2.5
80.4 2.9
295.1 0.8 Cracked
88.4 2.6 Cracked
157.1 1.5 Cracked
230.0 1.6 Cracked
2.04
0.77
direct Method)
ults of Slabs of Building OIL DISPENSARY UNIT SHOP,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST


AVERAGE VELOCITY
TIME (µ sec)
(Km/Sec)
NSARY UNIT SHOP
Loosed
158.9 2.11
161.1 1.86
195.1 1.54 Cracked
274.3 1.22 Cracked
176.1 1.36
183.1 1.90
1.67
0.35
direct Method)

f Columns and Beam of Building OIL DISPENSARY UNIT SHOP,IOCL,CIP TURBHE PLANT
AVERAGE HALF CELL
HALF CELL POTENTIAL -mV
POTENTIAL -mV
L DISPENSARY UNIT SHOP
184 173 181
178 190 163
110 125 139
267 286 268
236 254 249
252 236 240
182 152 169
161 176 165
154 178 174
n 194.1
eviation 45.7
cluding surface plaster)

ns of Building OIL DISPENSARY UNIT SHOP,IOCL,CIP TURBHE PLANT.

NATION EFFECT FROM THE


SURFACE* (mm)
UNIT SHOP
>30
25
15
>30
>30
>30
20
>30
>30
>30
>30
BHE PLANT.

HE PLANT.
E PLANT.
P TURBHE PLANT.

TURBHE PLANT.
URBHE PLANT.

L,CIP TURBHE PLANT.


Table 4.1:Rebound Hammer Test Results of Columns,Beams and Slabs o

RE
RCC MEMBER STRUCTURE
R1

BUILDING-SUB STATI
Gr.Flr.Column-01 (T) 44
Gr.Flr.Column-01 (B) 43
Gr.Flr.Column-02 (T) 52
Gr.Flr.Column-02 (B) 51
Gr.Flr.Column-03 (T) 54
Gr.Flr.Column-03 (B) 56
Gr.Flr.Column-04 (T) 54
Gr.Flr.Column-04 (B) 49
Gr.Flr.Column-05 (T) 49
Gr.Flr.Column-05 (B) 44
Gr.Flr.Beam-01 (N) 44
Gr.Flr.Beam-01 (S) 41
Gr.Flr.Slab-01 (N) 38
Gr.Flr.Slab-01 (S) 39
Gr.Flr.Beam-02 (E) 38
Gr.Flr.Beam-02 (W) 35
Gr.Flr.Slab-02 (N) 58
Gr.Flr.Slab-02 (S) 54
Mean
Standard Deviation

Table 4.2:Ultrasonic Pulse Velocity Test Results of Columns,Beams and

ULTRASONIC PULSE VELOCITY T


RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-SUB STATION
Gr.Flr.Column-01 230
Gr.Flr.Column-02 230
Gr.Flr.Column-03 230
Gr.Flr.Column-04 230
Gr.Flr.Column-05* 300
Gr.Flr.Beam-01* 250
Gr.Flr.Slab-01* 280
Gr.Flr.Beam-02 Cracked
Gr.Flr.Slab-02* 230
Mean
Standard Deviation
(Direct Method,*Indirect Method)

Table 4.3:Corrosion Analysis Test Results of Beam of Building SUB STA

RCC MEMBER STRUCTURE HALF CELL POTENTIAL -mV

BUILDING-SUB STATION
72
Gr.Flr.Beam-02 96
98
Mean
Standard Deviation
(excluding surface plaster)

Table 4.4.Carbonation Test results of Columns of Building SUB STATIO

CARBONATION EFFECT FROM THE


RCC MEMBER STRUCTURE
SURFACE* (mm)

BUILDING-SUB STATION
Gr.Flr.Column-01 2
Gr.Flr.Column-02 2
Gr.Flr.Column-03 2
Gr.Flr.Column-04 2
Gr.Flr.Column-05 2
(excluding surface plaster)
Columns,Beams and Slabs of Building SUB STATION,IOCL,CIP TURBHE PLANT.

REBOUND HAMMER TEST

COMP.
AVERAGE
R2 R3 R4 STRENGTH
READING
(MPa)
BUILDING-SUB STATION
46 50 52 48 55
48 46 42 45 50
51 48 49 50 59
54 52 50 52 63
53 56 59 56 >69
52 54 50 53 65
51 50 49 51 61
52 50 54 51 61
46 42 46 46 52
44 48 42 45 50
48 42 41 44 48
44 46 42 43 46
42 40 38 40 34
40 42 44 41 35
32 36 35 35 32
36 38 40 37 35
54 50 51 53 60
52 54 56 54 62
Mean 51.06
Standard Deviation 11.24

ults of Columns,Beams and Slabs of Building SUB STATION,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST


AVERAGE VELOCITY
TIME (µ sec)
(Km/Sec)
UB STATION
80.2 2.9
72.9 3.2
66.7 3.4
92.5 2.5
260.0 1.4 Rough Surface
67.5 4.4
89.3 3.1
Cracked
88.1 3.1
3.01
0.87
ndirect Method)

f Beam of Building SUB STATION,IOCL,CIP TURBHE PLANT.


AVERAGE HALF CELL
HALF CELL POTENTIAL -mV
POTENTIAL -mV
LDING-SUB STATION
77 89 79
78 85 86
74 90 87
an 84.3
Deviation 4.4
excluding surface plaster)

ns of Building SUB STATION,IOCL,CIP TURBHE PLANT.

NATION EFFECT FROM THE


SURFACE* (mm)

ON
2
2
2
2
2
HE PLANT.

TURBHE PLANT.
Table 5.1:Rebound Hammer Test Results of Column and Slabs of Buildi

R
RCC MEMBER STRUCTURE
R1

BUILDING-GATE CAB
Gr.Flr.Column-01 (T) 46
Gr.Flr.Column-01 (B) 45
Gr.Flr.Slab-01 (N) 50
Gr.Flr.Slab-01 (S) 52
Gr.Flr.Slab-02 (N) 48
Gr.Flr.Slab-02 (S) 50
Mean
Standard Deviation

Table 5.2:Ultrasonic Pulse Velocity Test Results of Column and Slabs of

ULTRASONIC PULSE VELOCITY


RCC MEMBER STRUCTURE
THICKNESS (mm)

BUILDING-GATE CABIN N0.1


Gr.Flr.Column-01 300
Gr.Flr.Slab-02 300
Gr.Flr.Slab-03 300
Mean
Standard Deviation
(*Direct Method,Indirect Method)
Column and Slabs of Building GATE CABIN N0.1,IOCL,CIP TURBHE PLANT.

REBOUND HAMMER TEST

COMP.
AVERAGE
R2 R3 R4 STRENGTH
READING
(MPa)
BUILDING-GATE CABIN N0.1
48 44 42 45 50
44 46 48 46 52
50 51 58 52 57
54 50 56 53 60
44 46 46 46 45
44 42 42 45 43
Mean 51.17
Standard Deviation 6.62

ults of Column and Slabs of Building GATE CABIN N0.1,IOCL,CIP TURBHE PLANT.

ULTRASONIC PULSE VELOCITY TEST

AVERAGE VELOCITY
TIME (µ sec)
(Km/Sec)
ATE CABIN N0.1
114.7 3.1
145.1 2.5
177.6 2.0
2.58
0.79