You are on page 1of 24

General Catalog

2016
Real ESD Solutions & New Technology

http://www.shishido-esd.co.jp/
Bar type Ionizer
HDC-AC with built-in high-voltage power supply

Bar type ionizer ELIMINOSTAT CABX CABX


Main Features
HDC-AC technology provides stable and long-term static elimination
capabilities. We have designed an ionizer that does not require
Dimensional Diagrams Mounting bracket cleaning over the long term.
(angle adjustable)
1) 30% increase in capabilities
22

2) Long-term stability of static elimination capabilities


3) Decrease in emitter needle abrasions
Intermediate bracket 4) Ultra low ozone
(over 1100mm)
Power supply and
signal connector
Mounting bracket
5) Superior ion balance
Indication Panel Electrode base
(ABS)
6) Minimum flow type nozzle
7) Cleaning timer
8) Emitter needle variations
74
67
59.8
84

0
9 1
2
8
7

INPUT :24V DC 150mA 6 5


4

AIR PRESSURE:0.01-0.5MPa(Clean and Dry Air Only)

9) Safety features
10

65
32 10 L (350-3100) Pitch 250

Air joint Emitter needle nozzle Emitter pole


350~1600mm: φ6
1850~3100mm: φ8
(stainless steel) Specifications
Model ELIMINATOR CABX
Pitch 50 Ion generation method Corona discharge method (HDC-AC)
L-20 Input power supply DC24V ±5%
L+32 Output voltage under No voltage contact output
TIMER RESET abnormal circumstances (by normal close MOSFET relay)
Unit dimensions 350~3100×92×29mm (W×H×D) DC24V±5%
Indicator Panel TIME SELECT
Air supply range Less than 0.5MPa
Ion balance Within ±30V
(distance 300mm, air pressure 0.3MPa at time of supply)
Operating environment Surrounding temperature: 5~40°C, surrounding humidity:
5%~85% (no condensation)Air supply: clean dry air
POWER CLEANING Operation manual, mounting bracket,
Accompanying items power supply and signal,connector cable (3m),
RUN ALARM intermediate bracket (over 1100mm)

Models according to electrode dimensions


★Please state the length of the electric pole and type of emitter needle required, Lengths Weights
CABX350 along with the product model when placing your order with Shishido Electrostatic.
350mm 450g
CABX600 CABX□□□□-□□
600mm 650g
Length and nozzle type Examples
CABX850 ●Lengths are 350-3100mm (250mm pitch) Length 1850mm, 850mm 860g
●Nozzle flow H or L high flow tungsten 1100mm 1060g
CABX1100 ●Emitter needle material W, S or G emitter needle:
1350mm 1260g
CABX1850-HW
CABX1350 1600mm 1470g
Length 600mm,
CABX1600 low-flow silicon 1850mm 1670g
emitter needle:
CABX600-LS 2100mm 1880g
CABX1850
2350mm 2080g
CABX2100 2600mm 2290g
CABX2350 2850mm 2500g
3100mm 2710g
CABX2600
CABX2850
CABX3100

Optional parts to support easy static elimination


◦CABX custom AC adapter : OCAB-DA2 (input voltage AC100V-240 V)
◦Intermediate bracket : OCABX-SUSP-A (over 1100 mm comes as standard equipment) Optional parts
◦Power supply and signal
extension cable : OCABX-ENC3M
◦Low-flow type L nozzle (length : 3 m)
Tungsten emitter needle type : OCABX-NDL-LW01
Silicon emitter needle type : OCABX-NDL-LS01
Glass emitter needle type : OCABX-NDL-LG01
◦High-flow type H nozzle
Tungsten emitter needle type : OCABX-NDL-HW01
Silicon emitter needle type : OCABX-NDL-HS01
Glass emitter needle type : OCABX-NDL-HG01

Custom AC adapter Intermediate bracket Power supply and signal extension


2 cable
ELIMINOSTAT
In case the target is Electric Sensitive Device, please
keep the distance between CABX bar to the target at least
300mm for safety reason.

Safety features detect


abnormal discharges
and sparks

Exchange of the emitter needle

Choose from two types of nozzles depending on the purpose


●For rapid static elimination: High-flow type H nozzle (4 holes) unit: l/min(ANR)
350 600 850 1100 1350 1600 1850 2100 2350 2600 2850 3100
0.05MPa 22 41 53 62 68 92 130 145 149 154 159 163
0.1MPa 32 59 81 95 105 112 194 223 229 244 250 259
0.2MPa 48 89 122 151 168 180 294 328 343 362 374 383
0.3MPa 61 117 165 200 230 248 381 426 466 496 516 531
0.4MPa 78 149 208 259 293 321 499 559 614 654 678 698
0.5MPa 95 177 255 323 362 393 622 687 748 806 848 882

●For low air consumption: Low-flow type L nozzle (2 holes) unit: l/min(ANR)
350 600 850 1100 1350 1600 1850 2100 2350 2600 2850 3100
0.05MPa 11 22 33 44 50 55 80 91 100 108 115 126
0.1MPa 16 32 48 52 60 81 112 130 146 158 171 184
0.2MPa 26 48 70 91 106 129 177 201 227 246 270 289
0.3MPa 34 63 95 123 149 173 240 276 303 333 363 397
0.4MPa 42 82 120 157 188 222 306 363 388 423 461 492
0.5MPa 51 91 143 187 233 274 374 425 471 515 556 598

CABX850mm, air pressure: 0.3 MPa CABX850mm, air pressure: 0.5 MPa
3.0 3.0
CABX850 high flow nozzle
CABX850 high flow nozzle
Static elimination time (sec)
Static elimination time (sec)

2.5 CABX850 low-flow nozzle


2.5
CABX850 low-flow nozzle
2.0 CABC 2.0
(our company’s existing products)
1.5 1.5

1.0 1.0

0.5 0.5

0.0 0.0
100 300 500 700 1000 100 300 500 700 1000 1200
Measurement distance (mm) Measurement distance (mm)

Measurement distance (mm) 100 300 500 700 1000 Measurement distance (mm) 300 100 500 700 1000 1200
CABX high flow nozzle 0.2 0.3 0.6 1.0 1.7 CABX high flow nozzle 0.3 0.2 0.5 0.7 1.3 1.9
CABX low-flow nozzle 0.2 0.4 0.8 1.5 2.4 CABX low-flow nozzle 0.3 0.2 0.6 1.1 1.8 2.2
CABC (our company’s existing products) 0.3 0.7 1.1 1.8 2.7

Bar type ionizer ELIMINOSTAT CABS


C ha rgeSNS

Specifications
Model CABS-AW-xxxx *1
Ionizer Bar CABS-DBW-xxxx *1
System Structure Controller CABS-CT1-xxxx *1
High voltage power unit CABS-TR1
Ion Generation Method Corona Discharge method
Input Voltage DC24V±5%
Electrical Specification Electric Consumption 12VA
Output voltage ± 7,500vp-p
Air tubing size Dia 6mm air tubing
Maximum supplied air
0.5MPa
pressure Dimensional Diagrams
Supplied Air CDA (Clean and dried air)
Ion Balance Below ±30V Main body Mounting Bracket
Screw hole for Air Fitting R 1/8 (Angle adjustable)
Decay time (At 300mm distance, 0.3 MPA air pressured, Bar length High-voltage connector
performance length:350mm) Mounting Bracket
*included Bar length, and it is available for same length model controller of bar. (Angle adjustable)
(38.5)

(34)

Specifications A(Pitch 40) 55


23.2

23.8

L
Sensing name Details
B(L+25)
HV Error Minute electrical discharge or over current detecting C(L+10)
Connector
6
4.2

Needle Error Nozzle unsettled or taking off detecting


31
29

Cleaning Ion creating level detecting


ChargeSNS The charged object detecting
20.5

29

Discharge Emitter
Please see SSD web site, in case you need System structure, or the drawing of each outlook. Fixing Hole (Unit : mm)
3
Nozzle-type
high frequency model
Compact AC Ionizer with an Ultra-small Built-in Piezoelectric Transformer
PIEZONIZER Zapp ZappII
Application
When handling the display and base of
a cellular phone, it is possible to work
under low voltage control at any time.

Power and Signal cable


(attached with ZappII)

The OZ-S nozzle at the front is an option.

Additional new specific products Dimension Diagram


High Volume air flow type(350L/min at 0.5Mpa): ZappII-H
4
3.
3-φ

Air joint φ6
Other specifications are followed as ZappII standard. 4.5 70 (15.85)

Insulated type(in case it can't be grounded or for the machine that M14×P1
PIEZONIZER
13

is not grounded with its frame to the earth grounding.): ZappII-U


22.5
13.3

Other specifications are followed as ZappII standard. FREE


LOCK
50

35.5

27.5
14.5

POWER H.V C.C ALARM

Static Decay Characteristics and Ion Balance (3.8)


(8.7)
15.8 10 10 10
Characteristics of the ZappII Model 18 4.5 71.5
Input connector
Static Decay Characteristics 86.5
0.7 25
(8.7)

20
(4.5)

0.6
+Decay time 15
-Decay time
0.5 Ion balance
Static decay time (sec)

Specifications
10
Ion balance (V)

5
0.4
Model ZappII
0
Input power supply DC (24V±10)
0.3
-5 Electric consumption 2.4VA
0.2 -10 Air pressure*1 Please check with below sheet
Airflow supply 30ℓ / min~160ℓ / min
-15
0.1 Ozone density 0.05ppm or less (air pressure input: 0.02Mpa, distance 300mm)
-20
Guaranteed operating (stored at -10°C to 60°C)
0 -25
temperature
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6
Guaranteed operating From 65% or less with no condensation
Supplied air pressure (MPa) humidity (stored at -90% or less with no condensation)
(Note 1) Using □150mm, 20pF charged plated monitor for measurements. Main unit dimensions 87×18×50mm (W×H×D) not including protruding portion
(Note 2) Static elimination time equals the decay time ±1000V→±100V. Weight 72g
(Note 3) Distance is measured 50mm from the plate monitor.
Accompanying items Power supply cable
(Note 4) Using Shishido Electrostatic’s standard nozzle OZ-S.

*1 The available air pressure range is different for each nozzle, please
Specifications other products check with below sheet.
High Air flow type(350L/min at 0.5MPa): ZappII-H OZ-S 0.05~0.60MPa OZ-C100~C500 0.05~0.50MPa
*Except Air consumption, other specifications follow ZappII OZ-TT 0.05~0.50MPa OZ-ST 0.05~0.30MPa
Insulated type(Isolated with grounding case): ZappII-U OZ-100B~300B 0.05~0.60MPa OZ-60SII 0.05~0.60MPa
*Except electrical insulation, other specifications follow ZappII OZ-100BLF~200BLF 0.05~0.60MPa OZ-F 0.05~0.60MPa
PZ-PSP120 0.05~0.50MPa OZII-SC 0.05~0.60MPa
OZII-90S 0.05~0.60MPa 0.05~0.60MPa
4
Nozzle type Air ionizer
Ultra low air consumption model PIEZONIZER
Compact size Air Ionizer
PIEZONIZER Zapp -L ZappII-L
Main Application
For small products that it can’t be
supplied with high air pressure.

Optional part
*Notice: The adjustment of ZappII-L is not same as ZappII, so it cannot use
with standard optional nozzles. ZappII-L exclusive nozzle

Power and Signal cable


(attached with ZappII) OZII-LC200

OZII-LC100
35.5

Dimension Diagram
.4
22.5

φ3
3-

(15.85)
4.5 70
163(263)
PIEZONIZER
22.5

POWER H.V C.C ALARM

71.5
11 108(208) 44 86.7
φ13

18
φ9.8

Main Features Specifications


High performance Model ZappII-L
Even ultra-low air pressure supply, it keeps high performance Input Voltage DC+24V±10%
ionization to compare with Zapp-II. Capacity 2.4VA
Integrated designed nozzle Output Voltage AC 2000 V
Discharge method High Frequency AC Corona discharge method
The point of ion creation is around the tip of nozzle and easy
Ion Balance Below ±15V(Distance at 50mm)
installation with flexible seamless piping. Available length of piping
Alarm output MOS FET Relay, Normally Closed contact(NO/NC)
is 100mm or 200mm. (Alarm)Maximum current: 100mA, Voltage: Below 30VDC
H.V. alarm function MOS FET Relay, Normally Closed contact(NO/NC)(C.C)
Cleaning Check output Maximum current: 100mA, Voltage: Below 30VDC.
In case high voltage shut down, alarm LED light and alarm output
function with non-signaled contact normally open or normally Discharge stop Discharge off: Short circuit to 0V, Discharge on: Open circuit
input(HV-OFF) (remained voltage below0.5V)
close use.
Ozone level Below 0.1ppm (Supplied air: 30 litter/min(ANR) at 50mm)*2
Cleaning Check [C.C] function Supplied Air Clean Dried Air
With detecting the abnormal discharge through the discharge Available air pressure 0.005~0.1MPa
emitter, it shows with C.C alarm LED and it links with signal output Air consumption Maximum 50 litter/min (ANR)
as normally open. Available environment 0~40°C / 15~85%RH (without condensation)
Dimensions 87×18×50mm (W×H×D) only body size
Weight Approx 78g
Accessories Manual, Power and Signal cable (2.5m), Nozzle is optional.
*2 Under some environment condition, it sometime makes more high level Ozone, we
recommend to use ozone-resistant materials around the tip of nozzle.
5
Nozzle-type
high frequency model
A wide variety of nozzle applications provided to meet various
application needs.
Optional part These nozzles are not for Nitrogen use.

●Seamless carrier pipes nozzle (external diameter: φ11) ●Nozzle


There is a teflon tube in the pipe. (standard type)
It is bent more freely than a past DK pipe. (OZ-S)

●Shower nozzle
(60°spray angle)
(OZ-60SII)

100-mm length ●Nozzle


(OZ-C100) (Variable angle 75°)
(OZII-SC)
●Shower nozzle
(90° injection angle)
(OZII-90S)

300-mm length ●Air Fitting Nozzle


(OZ-C300) (φ6 tubing)
OZ-PPC6-01
(Straight Air fitting)
●Air Fitting Nozzle
(φ6 tubing)
OZ-PPL6-01
(L shape Air fitting)

200-mm length
(OZ-C200) ●Option nozzle
(OZ-F)

400-mm length 500-mm length


(OZ-C400) (OZ-C500)

●Teflon carrier tube nozzle


(external diameter:φ6; internal diameter:φ4)
●Bar nozzles Stainless steel pipe
(external diameter: φ4; internal diameter: φ3)

120mm (OZ-120PSP)

●Bar nozzles (straight type) 500mm


(OZ-TT)
100mm length (OZ-100B) ●Silicon carrier tube nozzle
(external diameter:φ6; internal diameter:φ4)
200mm length (OZ-200B)

300mm length (OZ-300B)

500mm
●bar nozzle (free angle L-shaped type) (OZ-ST)
●AC adapter, Connection cable
200mm length (OZ-200BFL)

100mm length (OZ-100BFL)

(OZII-24VA)
Power supply(signal cable)
(OZII-24V) Power supply only grounding wire
6
PIEZONIZER
ZappII Options
For Nitrogen apprication (OZN serize) These nozzles are for only nitrogen use.

●Seamless carrier pipes nozzle (external diameter: φ11) ●Nozzle


There is a teflon tube in the pipe. (standard type)
It is bent more freely than a past DK pipe. (OZ-N-S)

●Teflon carrier tube nozzle


(external diameter:φ6; internal diameter:φ4)

100mm length
(OZ-N-C100)

500mm
(OZ-N-TT)
300mm length ●Silicon carrier tube nozzle
(OZ-N-C300) (external diameter:φ6; internal diameter:φ4)

500mm
200mm length (OZ-N-ST)
(OZ-N-C200) ●Fixing Bracket
(OZII-FM)

400mm length 500mm length


(OZ-N-C400) (OZ-N-C500)

Optional part (Controller)


ZappII controller
PIEZONIZER OZII-CB
Main Features
OZII-CB control the power supply and Air supply for ZappII with
connecting outside signal (sensor, foot switch, and other switch)
and the pulsed air control.

Specifications
Model OZII-CB OZII-CB-TV6
Dimension Diagram Available model ZappII, ZappII-H ZappII, ZappII-H
Available model ZappII, ZappII-H
OZII-CB-TV6 OZII-CB Power Voltage DC24V(with AC adaptor AC100~240V)
Ionizer operation indicator Ionizer operation indicator
Electric Consumption 0.3A
(Normal : red, abnormal : green) (Normal : red, abnormal : green) Indication Green: Normal, Red: Abnormal
Power switch Power switch Abnormal Output MOS FET Relay (non-voltage contact, Normally close)
(Maximum voltage: 30VDC, 100mA)
Normal condition of ZappII: ON, Abnormal condition: OFF
RUN/ALARM ON
RUN/ALARM ON

POWER POWER

Ⅱ-CB
OZ Ⅱ Zapp  Controller
Piezonizer Ⅱ-CB
OZ Ⅱ
PiezonizerZapp  Controller

Input signal from outside Input terminal (DC24V OUT, INPUT, 0V)
135 135 ZappII start to work: Short INPUT and 0V or supply 0~3Volt to INPUT
120
4-φ4.5 120
4-φ4.5
30 30 ZappII stop to work: Open INPUT and 0V or supply 5~24Volt to INPUT
Supplied Air Clean and Dried air
30
30

Available air pressure 0.05MPa~0.6MPa


75
60

75
60

3-M3 3-M3 Air pressure control --------- With air throttle valve
3
3

AIR PRESSURE
--

Maximum air consumption 450L/min(ANR) *only Contoller 240L/min(ANR) *only Contoller


+

CONT: Continuously blow, PULSE Hi: High Pulse blow(10Hz),


Air output
105.2
Air input Air output
105.2
Air input Air output control PULSE Lo: Low Pulse blow(5Hz)
Connector pin housing Connector pin housing

AIR OUT AIR IN


#4
#2
#3
#1 AIR OUT AIR IN
#4
#2
#3
#1
Available environment 0~40°, below 85%RH(without condensation)
Dimensions 135x50x75(WxHxD)
0V T UT

0V T UT
O

O
50

50

IONIZER OUT DC IN GND # 1: Power supply DC24V IONIZER OUT DC IN GND # 1: Power supply DC24V
PU V

PU V
IN 24

IN 24
DC

DC
Lo

Lo
LS Hi

# 2: Power DC0V # 2: Power DC0V


PU NT

NT
PU E
E

E
LS

LS
CO

CO

Weight 530g
PU

# 3: abnormal output (b contact) # 3: abnormal output (b contact)


# 4: abnormal output (b contact) # 4: abnormal output (b contact)

Ionizer connector Earth terminal Earth terminal


Ionizer connector AC adaptor, Connecting cable with ZappII, grounding cable, Air
Air mode setting AC adapter input connector Air mode setting AC adapter input connector Accessories
Terminal block Terminal block (Unit: mm)
tubing(φ6mm x 2m), Operation manual, Contact pin(5pcs).
*The life time of electric valve in the controller is below 50 million times. 7
Gun-type and Pencil-type
high frequency model
Ion Blow Gun
PIEZONIZER AGZIII AGZIII
Dimension Diagram

12.5 24.5 (140.12)

13.5
∅22
20
ION BLOW GUN AGZⅢ

10 Hook
AC adapter
Resin nozzle
(Accessories)

(135.8)
POWER(GREEN)
ALARM(RED)
Lever

25
Air IN φ6
One-touch joint
(3m)
Input cable (Unit: mm)

Static Decay Characteristics


0.7

Specifications 0.6
+Decay time
-Decay time

Model AGZIII
Input Voltage DC24V (AC adaptor supplied; AC100~240V) 0.5
Static decay time (sec)

Indicator Green: Normality power output. RED: Abnormality power output


0.4
Ion Balance ±15V or less (at factory shipment)
Ozone Abundance 0.04 ppm or less (at 150mm)
0.3
Applicable fluid Cleaned air
Air pressure range 0.05~0.6MPa 0.2
Supplied air flow Max. 370ℓ/min(ANR) (at 0.6MPa)
Environment 0~40°C / 65%RH or less (no condensation) 0.1
Dimensions 164.6×25×135.8mm (L×W×H) exc. protrusions.
Weight Approx. 200g (exc. cable) 0
0.1 0.2 0.3 0.4 0.5 0.6
Standard Part Instruction manual, AC adapter Supplied air pressure (MPa)

Optional for AGZIII


Specifications
AGZIII Air Controller Model OAGIII-CB

OAGIII-CB
Available model AGZIII
PIEZONIZER Power Voltage
Electric Consumption
DC24V (with AC adaptor AC100~240V use AGZIII adaptor)
0.2A (with AGZIII gun)
Indication Green: Supply the power and Air to AGZIII
Supplied Air Clean and Dried air
Available air pressure 0.05MPa~0.7MPa
Air pressure control 500L/min (ANR) *only Contoller
Maximum air CONT: Continuously blow, PULSE Hi: High Pulse blow
consumption (10Hz), PULSE Lo: Low Pulse blow (5Hz)
Open the INPUT port: Start to work, Close the INPUT port:
Air output control
Stop to work.
Available environment 0~40°, below 85%RH (without condensation)
Main Features Dimensions 135x50x75 (WxHxD)
Weight 490g
OAGIII-CB control the power supply and Air supply for AGZIII Connecting cable with AC adaptor (2m), Connecting cable
gun with connecting outside signal (sensor, foot switch, and Accessories
with AGZIII (0.3m), grounding cable, Air tubing (φ6mm x 3m),
other switch) and the pulsed air control. Operation manual, Contact pin (5pcs).
*The life time of electric valve in the controller is below 50 million times.

Flat nozzle for AGZIII Brush for AGZIII


OAG-F OAG-BRS
This is the optional part for
brushing off the dust.
Three kinds of size of brush
*OAG-BRS-1: nylon brush
diameter φ0.1
*OAG-BRS-2: nylon brush
diameter φ0.2
*OAG-BRS-3: nylon brush
diameter φ0.3
Available for AGZ/ANZ series.
8
PIEZONIZER
Ion Blow Gun
PIEZONIZER AGZII-PA Pulse air
AGZII-PA Wave motion nozzle

Ion spray nozzle


(flow adjustment possible)

Ion air

Pulse dust removal


Ion static elimination
Specifications
Model AGZII-PA
Input power supply 24VDC (with AC100~240VAC adapter)
Electric consumption Approx. 100mA
Weight Approx. 330g (when only the wave motion nozzle is attached)
Main unit dimensions 180×25×175mm (L×W×H)
(when wave motion nozzle is attached)
Main Features Ozone density 0.04ppm (200mm from the nozzle hole)
The PIEZONIZER AGZII-PA is a compact and lightweight air gun Fluid used Clean air
Air pressure 0.3~0.6MPa
type ionizer that eliminates static electricity from charged objects as Operating Environment 0~40°C (with no condensation)
well as a wave motion nozzle feature to powerfully blow away dust Standard Part Operation manual, AC adapter, connector cable,wave motion
attached by static electricity with pulses of air. nozzle, adjustable flow nozzle

ANZ-SC3
Pencil Type Ionizer
PIEZONIZER ANZ-SC3
Dimension Diagram
ANZ Main Body
Indication LED
(Green: Normal. Red: Abnormal)
14.2
18

Tip Nozzle
φ18 Operation Switch Power Switch
35.3
RUN/ALARM ON
24.5

POWER
7.9

ANZ-SC3 Pencil Type Ionizer


Piezonizer

135 4-φ4.5
136

120
111.5

3-M3
30
75
60

30
3


AIR PRESSURE
13.5
18

Controller Air tube


11

28.5
Power Cable Air Tubing
(Lengthk:1800㎜) (φ6)

Grounding wire
Air Output (φ6)
105.2 (12.4)

Controler Unit AIR OUT AIR IN

Control Valve for Air Pressure


50

IONIZER OUT DC IN GND

AC adapter
Lo
LS Hi
NT

PU E
E

Air Input (φ6)


LS
CO
PU

Output to Ionizer Grounding Terminal


Ionizer main unit Air blow select switch Power Inn (from AC adaptor)
(Unit: mm)

Main Features Specifications


Model ANZ-SC3 is Pencil type air ionizer with compact power unit Model ANZ-SC3
inside. The size is 18mm dia, the weight is just 95g as light and Input Voltage DC24V (with AC adaptor for AC100~240V)
compact. Indicator Green: Normal, Red: H.V. Abnormal
Abnormal output MOS FET Relay (non-Voltage contact, Normally close)
(Maximum Voltage: 30VDC, 100mA)
Static Decay Characteristics Normal: ON, H.V. Abnormal: OFF
0.6 Buzzer Alarm When H.V. is abnormal, the buzzer is on.
Ion Balance Under ±15V
0.5
+Decay time Air Pressure Range 0.05~0.6MPa (with Speed Controller)
-Decay time
Air Consumption Maximum 190ℓ/min
Air blow mode Continuously blow, High speed Pulse (10Hz),
Static decay time (sec)

0.4
Low Speed Blow (5Hz)
Ozone level Under 0.04ppm (150mm from the nozzle hole)
0.3 Dimensions φ18×154mm (ANZ), 135×50×75mm (W×H×D) (Controler)
Weight 95g (ANZ), 570g (Controler)
0.2 Avairable Tempareture 0~40 Degree/ 65%RH or less (no condensation)
Avairable Humidity 15~65% (Without condensation)
0.1 Standard Part ANZ nozzle (with cable), Controler,
AC Adaprot (AC100~240V), Grounding Cable,
Air tubing, Abnormal output cable, Manual
0
0 0.1 0.2 0.3 0.4 0.5 0.6 Optional part Air Pressure Guage
Supplied air pressure (MPa) Nozzle Application Same as ZappII
*The life time of solenoid valve inside this controller will be for 50 million time. 9
Static Eliminator Blowers
HDC-AC with built-in high-voltage power supply
FEATURE of HDC-AC Ionizer Abnormal alarm and output signal.
With SSD high technology HDC-AC (Hybrid Digital controlled AC), it Angle locked function keeps fixed angle direction. (X2MB/X4MB)
performs as less particle attach and long term stability performance. Easy maintenance with detachable louver and emitter needle unit.
Wide and Straight ionization with two kinds of louver part. (XMB/X2MB) Less maintenance structure designed.
Safety operation with minute discharge detection and over current detection. Variable air speed control.

Slim and light weight Air ionizer Optional Parts

WINSTAT BF-XMB
Emitter needle unit Filter for replacement
(DNU-W60) (10 sheets package)
(OBF-FZA-1-10)

Straight Louver Static Elimination Area BF-XMB (Straight Louver)


300

200

100

Air 0

-100

Main Features Wide angle Louver -200

-300
Compact Air Ionizer WINSTAT BF-XMB is slim and light-weight (*with Maximum

100

200

300

400

500

600

700

800

900

1000

1100

1200
(mm)
Air flow)
designed desktop ionizer with featuring SSD high technology HDC- Decay Time (sec) 0-2 2-4 4-6 6-8 8-10 10-12
AC that has long term and stable static elimination capabilities. *Test by CPM with 150x150mm plate (20pF)
*Above data is actual data not for guaranteed.

Wide blow Air Ionizer Optional Parts

WINSTAT BF-X4MB
Emitter needle unit Filter for replacement
(DNU-W85) (10 sheets package)
(OBF-F2ZA-1-10)

Static Elimination Area


500
400
300
BF--X4MB

200
100
AIR IONIZER
WINSTAT

Air 0
-100
Main Features
FAN SPEED
FAN LOCK
FAN ADJ.

-200
O.C.
RUN
POWER

P.D.

-300
Wide blow Air Ionizer WINSTAT BF-X4MB is slim and light-weight
OFF
ON

-400
-500
designed desktop ionizer with featuring SSD high technology HDC-
100
200
300
400
500
600
700
800
900
1000
1100
1200

(*with Maximum Air flow) (mm)


AC that has long term and stable static elimination capabilities. Decay Time (sec) 0-2 2-4 4-6 6-8 8-10 10-12
Wide Coverage area as 400mm *Test by CPM with 150x150mm plate (20pF)
*Above data is actual data not for guaranteed.

Static eliminator blower Optional Parts

WINSTAT BF-OHP3B
Emitter needle unit Filter for replacement
(DNU-W85) (10 sheets package)
(OBF-F2ZA-1-10)
Static Elimination Area
BF-OHP3A Static elimination area
600
500
Main Features 400
HIGH

300
FLOW

LOW

New Overhead ion blower BF-OHP3B is based on SSD HDC-AC Air 200
H.V ALARM
POWER

100
BF-OHP3B
WINSTAT
AIR IONIZER

technology with high performance. 0


-100
This is the overhead air ionizer with SSD new technology "HDC- -200
AC". -300
-400
High performance and stable balance. -500
Easy maintenance. (※Maximum airflow)
-600
100
200
300
400
500
600
700
800
900
1000
1100
1200

(mm)
Safety controlled as pulse discharge and current controll.
0-2 2-4 4-6 6-8 8-10 10-12 12-14
Meets RoHS standards. Static elimination time(sec)
10
WINSTAT
Application
When handling an IC in a tray, it is
possible to maintain low voltage in the
IC at any time.

Dimension Diagram Specifications


Model BF-XMB
Input Voltage DC24V (AC adaptor AC100~240V available)
Capacity 6VA
(Unit : mm) Output Voltage ± 7000Vo-p
Power Switch (67) Ion Balance Below ±10V (Distance at 300mm)
(143) 5 50
104 Filter cover Air Volume 0.7~1.2m3/min
Front Louver
1.2~1.9m/s (with Straight Louver at 300mm)
Air Speed
Filter 0.7~1.2m/s (with Wide angle Louver at 300mm)
Knob Bolt Ozone level Below 0.004ppm (Distance at 150mm)
Available environment 0~40°C / 15~85%RH (without condensation)
138.5
126

Filter Pre-filter level


82
75.5

POWER RUN FAN ADJ. FAN SPEED


INPUT DC24V
CAP.6VA 1:ALARM
Fixing Bracket Normal: ON, Abnormal (HV alarm or fan alarm with Red LED
light): OFF
2:GND
P.D. O.C. FAN LOCK 3:DC 0V
6 5 4

Alarm output
4:ALARM
3 2 1 5:NOT USE

AIR IONIZER WINSTAT BF-XMB 6:DC+24V

MOS FET Relay, Normally Closed contact.


MADE IN JAPAN

Maximum current: 200mA, Voltage: Below 30VDC.


60
Fixing Hole (3-φ4.5) Power and Signal output
Dimensions 104x126x67mm (W×H×D) not including projecting portion
Weight Approx. 560g(with Bracket)
Sound level 51dB (A) (at 1m distance)
AC Adaptor, Wide angle louver, Signal output cable,Cleaning
Accessories Manual Brush
Optional Part Emitter Needle unit (DNU-W60),Filter (10pcs) (OBF-FZA-1-10)

Dimension Diagram
Power Switch Indicator panel
Indication Panel

Specifications
ON

BF--X4MB
POWER RUN FAN ADJ.

Model BF-X4MB
WINSTAT
OFF P.D. O.C. FAN LOCK FAN SPEED AIR IONIZER

Louver
(78.5)
Input Voltage DC24V (AC adaptor AC100~240V available)
370 14 51 Filter Filter cover Capacity 25A
Output Voltage ± 7500Vo-p
Ion Balance Below ±5V (Distance at 300mm)
159

Air Volume 1.4~3.2m3/min x 2 fans


190.5

INPUT DC24V
CAP.25VA 1:ALARM
2:GND
3:DC 0V
6 5 4 4:ALARM

Air Speed
5:NOT USE

0.7~1.8m/s (at 300mm)


3 2 1 6:DC+24V
MADE IN JAPAN
68.5

Ozone level Below 0.006ppm (Distance at 150mm)


90
385
90 51
The power and signal output 6 5 4 1:ALARM 4:ALARM
Available environment 0~40°C / 15~85%RH (without condensation)
Knob Bolt
Filter
2:GND 5:NOT USE

Fixing Hole (3-φ4.5) Fixing Bracket


3 2 1 3:0V 6:24V DC
Pre-filter level
Alarm output MOS FET Relay Non-voltage contact (NC output) HV alarm or
Indicator Panel POWER (Power Indicator: Green)
RUN (Run Indicator: Green)
fan alarm: OFF
Power Switch Air Flow Controller Dimensions 370x159x78.5mm (W×H×D)
FAN SPEED
ON (Fan speed Indicator: Weight Approx.1700g(with Bracket)
Green)
POWER RUN FAN ADJ.
Materials Main Body: ABS, Emitter: tungsten, Bracket: SECC
OFF

62dB (A) (at 1m distance)


P.D. O.C. FAN LOCK FAN SPEED

Sound level
FAN LOCK (Fan alarm indicator: Red)
O.C. (Over Current indicator: Red) Accessories Manual, AC Adaptor, Signal output cable, Cleaning Brush
P.D. (Pulse Discharge indicator: Red)
Optional Part Emitter Needle unit (DNU-W85), Filter (10pcs) (OBF-F2ZA-1-10)

Decay Performance
POWER INDICATOR
Specifications
Model BF-OHP3B
AIR FLOW Input Voltage AC100V to 240V 50/60Hz
CONTROLER Capacity 42VA
Output Voltage ±7,500V0-p
Ion Balance ±10V or less (at factory shipment)
HIGH VOLTAGE ALARM INDICATOR
Air Flow 2.6 to 4.0m3/min×3 fans
Ozone Abundance 0.006ppm or less (at 150mm distance)
Dimension Diagram Environment 0 to 40°C / 15 to 85%RH (No condensation)
1020
110 400 400 110
Filter Pre-filter class
Dimensions 1020×60.5×150mm (W×H×D)
Weight Approx. 5.0kg
150

Material Main Body : SECC, Emitter Needle : Tungstane


128 Sound level 66dB(A) (Distance at 1m)
Fixing hole 4- diameter 12mm Filter 94
Fixing hole 4- diameter 5.5mm 60 Accesories Operation Manual, AC adaptor, Cleaning Brush
10

Filter covering Air Flow Controler

Optional Part Discharging needle unit: DNU-W85


60.5

INPUT FLOW
100-240V?` 50/60Hz AIR IONIZER
FUSE 1A POWER

OFF ON WINSTAT POWER

BF-OHP3B

Filter(10 sheet pack) : OBF-F2ZA-1-10


H.V ALARM
LOW HIGH

Power Switch Front Panel louver


Power Inlet Manual, AC Adaptor, Fixing Bracket, Rubber packing, Signal
Accessories output cable, Cleaning Brush
FUSE HOLDER

Emitter Needle unit (DNU-W85),


Optional Part Filter (10pcs) (OBF-F2ZA-1-10)
11
Static Eliminator Blowers
HDC-AC with built-in high-voltage power supply
Static Elimination Blowers Indicator Panel POWER (Power Indicator: Green)
RUN (Run Indicator: Green)

WINSTAT BF-X2MB Air Flow Controller


FAN SPEED
(Fan speed Indicator: Green)

Optional Parts

FAN LOCK (Fan alarm indicator: Red)


O.C. (Over Current indicator: Red)
P.D. (Pulse Discharge indicator: Red)
Dimension Diagram
Emitter needle unit Filter for replacement (192)
150
66
50
Filter Cover Filter

(DNU-W85) (10 sheets package)


(OBF-F2MA-1-10)
Knob Bolt

Main Features

197
182
Compact Air Ionizer WINSTAT BF-X2MB is slim and light-weight
designed desktop ionizer with featuring SSD high technology HDC- Fixing Bracket

AC that has long term and stable static elimination capabilities.


INPUT DC24V
POWER CAP.10VA 1:ALARM
2:GND

BF-X2MB
3:DC 0V
6 5 4
WINSTAT 3 2 1
4:ALARM
5:NOT USE

AIR IONIZER 6:DC+24V


MADE IN JAPAN

Specifications Front Louver 45 45 Main Power Switch


Fixing hole 3-φ4.5 Power and Signal output

Model BF-X2MB AC Adaptor (Accessory)


Input Power DC24V (AC adaptor AC100~240V available) Connector Pin Layout
molex 5557-06R AC Adaptor
Grounding cable Input: AC100~240V 50/60Hz
Capacity 10VA 1(White): Alarm AWG 20 (Green) Output: DC24V 1.25A
2(Green): GND
Output Voltage ± 7500Vo-p 3(Black): DC 0V
A
6 5 4
4(Yellow): Alarm
Ion Balance Below ±10V (Distance at 300mm) 3 2 1 5: not used

34
1500(±50) 95 1500(±50)
Air Volume 1.4~3.2m3/min 6(Red): DC+24V (Unit : mm)

1.8~3.8m/sec (with Straight Louver at 300mm) Looking from the A direction


Air Speed
0.4~0.6m/sec (with wide angle louver at 300mm)
Ozone density Below 0.004ppm (Distance at 150mm) Static Elimination Area
300
Available environment 0~40% / 15~85%RH (without condensation) Straight Louver
200
Filter Pre-filter level
MOS FET Relay Non-voltage contact (NC output) HV alarm or 100
Signal Output
FAN SPEED

fan alarm: OFF


0
FAN LOCK
FAN ADJ.

Air
Dimensions 150x182x66mm (W×H×D)
RUN

O.C.

-100
POWER

Approx 1000g (with Bracket)


P.D.

Weight Wide angle Louver


Sound level 59dB (A) (at 1m distance) -200
Manual, AC Adaptor, Wide angle louver, Signal output cable, -300
Accessories Cleaning Brush
100

200

300

400

500

600

700

800

900

1000

1100

1200
(*with Maximum
Emitter Needle unit (DNU-W85), (mm)
Air flow)
Optional Part
Filter (10pcs) (OBF-F2MA-1-10) Decay Time (sec) 0-2 2-4 4-6 6-8 8-10 10-12

Static Elimination Blowers Dimension Diagram Indicator Panel

BF-X2MC
Main Power Switch
RUN Indicator (Green) Abnormal Indicator (Red)
POWER Indicator (Green) Air speed Controller

WINSTAT ON

WINSTAT
POWER RUN ALARM -
ION BALANCE
+ FAN ADJ.
POWER

AIR IONIZER
OFF
CLEANING

BF- -X2MC AUTO ON


ON OFF
MANUAL
PUSH ON

Auto-Cleaning ON Ion Balance Indicator


Optional Parts Front Louver (192)
Indicator (Yellow)
(91)
Cleaning Start button
Auto-Cleaning switch
150 75

Filter

Knob Bolt
182
197

Fixing Bracket
108

Filter for replacement WINSTAT


AIR IONIZER

BF- -X2MC
POWER

AUTO ON
RUN

ON
ALARM

CLEANING
AUTO
OFF

ION BALANCE

MANUAL
PUSH ON
+ FAN ADJ.
INPUT DC24V
CAP.18VA 1:ALARM
2:GND
6 5 4 3:DC 0V
4:COMMON
5:ION BALANCE
3 2 1 6:DC+24V

(10 sheets package)


MADE IN JAPAN

Filter Cover
(OBF-F2MA-1-10) 45 45
Fixing hole 3-φ4.5 37.5 Power and Signal output

Specifications
Model BF-X2MC
Input Power DC24V (AC Adaptor AC100~240V avairable)
Capacity 18VA
Output Voltage ± 7500Vo-p
Main Features Ion Balance Below 5V (Distance:300mm)
Air Volume 1.4~3.2m3/min
Model BF-X2MC is update model of BF-2ZC with automatically 1.8~3.6m/sec (With straight Louver: 300mm center)
Air Speed
cleaning emitter function as maintenance free performance. 0.4~0.6m/sec (With Wide angle Louver: 300mm center)
Automatically emitter cleaning (once per day), and manual cleaning Ozone density Below 0.004ppm (Disance:150mm)
Available environment 0~40% / 15~85%RH (without condensation)
available Ion Balance indicator Filter Pre-filter level
With SSD HDC-AC Technology, keep long stability performance ALARM: MOS FET Relay Non-Voltage contact (NC)
Safety function with Pulse discharge detection, Over current (HV abnormal, or Fan abnormal: OFF)
Signal Output
ditection ION BALANCE: MOS FET Relay Non-Voltage contact (NC)
(Ion Balance abnormal: OFF)
With alternative front louver, you can use for long distance or wide Dimensions 150x182x75mm (WxHxD)
area ionization. Weight Approximately 1,2kg (with stand frame)
Sound level 59dB(A) (Distance: 1m)
Easy angle adjustable with locked for each angle
Operation Manual, AC Adaptor,Wide angle louver,
Alarm function: High voltage abnormal and locked Fan with alarm Accessories Signal output cable
output Optional Part Filter (10pcs)
12
Static Eliminator Blowers
High frequency type WINSTAT
Safety operation with minute discharge detection and over current
FEATURE of HF-AC Ionizer detection.
With SSD high frequency HF-AC, it performs as compact light and Angle locked function keeps fixed angle direction. (X2ZB-V2/X4ZB)
weight structure. Easy maintenance with detachable louver and emitter needle unit.
Wide and Straight ionization with two kinds of louver part. (XZB/ Variable air speed control.
X2ZB-V2) Cleaning Check (CC) alarm LED. (X2ZB-V2/X4ZB)

Compact size Air Ionizer


WINSTAT SZA Dimension Diagram
70
Power supply
Front louver
28 25
45
3-M3
mounting holes

As usual package of BF-SZAII, AC adaptor is

24
ON

not included, so in case you use AC power line,

POWER

30
please purchase AC adaptor AD-24V100-6P as

81
OFF

98
optional part. H.V FAN
FAN
ADJ
AIR IONIZER

33
POWER ALARM ALARM

MIN

Main Features

18
BF-SZA�

As unparalleled small designed, it is easy to install into small Air Flow Controller
65 12.5 45
Fixing Bracket
space like in the machine. Fan abnormality
indicator lamp (red)
Power supply input and
signal output connectors
Power supply
Easy installation with using the attached fixing bracket, or indicator lamp (green) 5
High-voltage output Mounting holes
directly use the fixing hole at back side. abnormality
indicator lamp (red)

Specifications

76
60°
5
R5 φ4
.5
Model BF-SAZII R2.2
5
Input Voltage DC24V±5% (AC adaptor is not included)
(Unit: mm)
Capacity 5VA
Output Voltage AC 2500V
Ion Balance Below ±10V
Static Elimination Area
Air Volume 0.2~0.30m3/min BF-SZA Static Elimination Area
200
Ozone level Below 0.04ppm (Distance at 150mm)
150
Available environment 0~40°C / 15~65%RH (without condensation)
100
Filter No filter
50
Dimensions 70×81×45mm (W×H×D)only body size
Weight Approx 370g (with Bracket) Area 0

Sound level 48dB (A) (at 1m distance) -50


Normal: ON, Abnormal (HV alarm or fan alarm with Red LED -100
light): OFF
Alarm output MOS FET Relay, Normally Closed contact. -150
Maximum current: 200mA, Voltage: Below 30VDC. -200
(*with Maximum Air flow)
50

100

150

200

250

300

350

400

450

500

550

600
Accessories Manual, Signal output cable, Cleaning Brush (mm)

Optional Part AC Adaptor (OBF-24V-AD-SZAII) AC100~240V available Decay Time (sec) 0-2 2-4 4-6 6-8 8-10 10-12

Slim and light weight Air ionizer


WINSTAT BF-XZB
Dimension Diagram
Main Features ON
POWER

Compact Air Ionizer WINSTAT


OFF

Power Switch
BF-XZB is slim and light-weight Front Louver (67)
(143) Filter Cover
designed desktop ionizer with 104 5 50
Filter

featuring SSD HF (high frequency)


AC technology
126
138.5

Specifications
82

Knob
75.5

H.V ALARM FAN ADJ.


INPUT DC24V
CAP.7.2VA 1:ALARM
2:GND
3:DC 0V
Bolt
6 5 4 4:ALARM

BF-XZB 3 2 1 5:NOT USE


AIR IONIZER WINSTAT 6:DC+24V

Fixing
MADE IN JAPAN

Model BF-XZB Bracket


Input Voltage DC24V (AC adaptor AC100~240V available) Air Flow Controller Fixing hole 3-φ4.5 60
Abnormality indicator lamp (red) Power and Signal
Capacity 7.2VA High-voltage power supply output
indicator lamp (green)
Output Voltage AC 2500V
Ion Balance Below ±10V (Distance at 300mm)
Air Volume 1.0~1.7m3/min
Static Elimination Area
Air Speed 1.6~2.4m/s (with Straight Louver at 300mm)
0.7~1.3m/s(with Wide angle Louver at 300mm)
Ozone level Below 0.04ppm (Distance at 150mm) Straight Louver BF-XZB Static elimination area
300
Available environment 0~40°C / 15~65%RH (without condensation)
200
Filter Pre-filter level
OFF
ON

Indication
POWER

Green: Normal condition(H.V), Red: HV Abnormal(ALARM) 100


Normal: ON, Abnormal(HV alarm or fan alarm with Red LED
Alarm output light): OFF Area 0

Dimensions 104×126×50mm (W×H×D) only body size Wide angle -100


460g (with Bracket) Louver
Weight
-200
Sound level 60dB (A) (at 1m distance)
Manual, AC Adaptor, Wide angle louver, Signal output cable, -300
Accessories
100

200

300

400

500

600

700

800

900

1000

1100

1200

Cleaning Brush (*with Maximum Air flow) (mm)


Optional Part Emitter Needle unit (DNU-W60), Filter (10pcs) (OBF-FZA-1-10) Decay Time (sec) 0-2 2-4 4-6 6-8 8-10 10-12
13
Static Eliminator Blowers
High frequency type WINSTAT
Static eliminator blower Indicator Panel H.V ALARM (high voltage indicator: green)
C.C (check cleaning indicator: yellow)

WINSTAT BF-X2ZB-V2 Fan Adjuster

Condition in which
the louver and
the discharging ALARM (alsrm indicator: red)
Power switch POWER (power indicator: green)
unit have been
removed Dimension Diagram

ON OFF
FAN ADJ.

Main Features
POWER H.V C.C ALARM

Louver and emitter needle easy to remove and replace. Front Panel louver (192) (68) Filter covering
150 6 50
Filter
Can choose the area for static elimination with two types of
louvers.
Knob Bolt
Main unit angle can be adjusted and locked and the angle never
changes due to vibrations.

182
197
Specifications

108
Fixing bracket
INPUT DC24V
CAP.10VA 1:ALARM
2:GND
3:DC 0V

BF-X2ZB-V2
6 5 4 4:ALARM
WINSTAT

Type BF-X2ZB-V2
5:NOT USE
3 2 1
6:DC+24V
AIR IONIZER MADE IN JAPAN

Input Voltage DC24 (VAC adaptor supplied; AC100~240V)


45 45 Fixing hole The power and signal output
Capacity 10VA 165 3- diameter 4.5mm
Output Voltage AC 3000V (Unit: mm)
Ion Balance ±10V or less (at 300 mm; at factory shipment)
Air Flow 1.6~3.3m3 / min
Static Elimination Area
Wind Velocity 1.9~3.2m / sec (Straight louver at 300mm center) BF-X2ZB Static elimination area
300
0.7~0.9m / sec (Wide angle louver at 300mm center)
Ozone Abundance 0.04 ppm or less (at 150 mm) 200
FAN ADJ.
Environment 0~40°C / 15~65%RH (without condensation)
Filter Pre-filter Class 100
Output Signal Air
ALARM

MOS FET Relay No-voltage Contact Output 0


C.C

HV abnormal (Red LED with ALARM)


POWER H.V
OFF

-100
Dimensions 150×182×68mm (W×H×D) exc. protrusions.
ON

Weight Approx. 820g (with Bracket) -200


Noise Level 57dB (A) at 1m distance
-300
Accessories Instruction Manual, AC adapter, wide-angle louver,output signal
100

200

300

400

500

600

700

800

900

1000

1100

1200
(*with Maximum Air flow) (mm)
connecting lead, cleaning brush
Optional Items Discharging needle unit (DUN-W85), filters (10-sheet set) Decay Time (sec) 0-2 2-4 4-6 6-8 8-10 10-12

Wide blow Air Ionizer Optional Parts

WINSTAT BF-X4ZB Emitter needle unit


(DNU-W85)
Filter for replacement
(10 sheets package)
(OBF-F2ZA-1-10)

High-voltage power supply


Indicator Panel indicator lamp (green)
Abnormality indicator lamp (red)
Power supply
Air Flow Controller
ON

H.V ALARM FAN ADJ.

OFF C.C

Cleaning check indication (Yellow)


Dimension Diagram
Power supply 1: Alarm
Connector Pin Layout
Indicator Panel 6 5 4 2: GND
3: DC 0V
3 2 1 4: Alarm
Main Features ON

OFF
H.V

O.C
ALARM FAN ADJ.

WINSTAT
AIR IONIZER BF-X4ZB 5: not used
6: DC+24V
Compact Air Ionizer WINSTAT BF-X4ZB is Louver
14
(78.5) Filter
370 51 Knob Bolt Filter Cover
slim and light-weight designed desktop ionizer with featuring SSD
HF (high frequency) AC technology
Wide Coverage area as 400mm
159
190.5

INPUT DC24V
CAP.25VA 1:ALARM
2:GND
3:DC 0V
6 5 4 4:ALARM
5:NOT USE
3 2 1 6:DC+24V
MADE IN JAPAN
68.5

Specifications
90 90
Model BF-X4ZB 385
51
Fixing Bracket
Input Voltage DC24V (AC adaptor AC100~240V available) Fixing hole 3-φ4.5
Capacity 25VA at maximum fan speed
Output voltage AC 3000V
Static Elimination Area
BF-X4ZB Static Elimination Area 500
Ion Balance Below ±10V (Distance at 300mm)
400
Air Volume 1.4~3.2m3/min × 2fan
300
Air Speed 0.7~1.8m/sec
200
BF-X4ZB

Ozone Level Below 0.04ppm (Distance at 150mm) 100


AIR IONIZER
WINSTAT

Available environment 0~40°C / 15~85%RH (without condensation) 0


Area
Filter Pre-filter level -100
Alarm output Normal: ON, Abnormal(HV alarm with Red LED light): OFF -200
FAN ADJ.
ALARM

O.C
H.V

Dimensions 370x159x78.5mm (W×H×D) only body size -300


OFF
ON

Weight 1600g (with bracket) -400

Sound Level 63dB (A) (at 1m distance) -500


(*with Maximum Air flow)
100
200
300
400
500
600
700
800
900
1000
1100
1200

Accessories Manual, AC Adaptor, Signal output cable, Cleaning Brush (mm)

Optional Part Emitter Needle unit (DNU-W85), Filter (10pcs) (OBF-F2ZA-1-10) Decay Time (sec) 0-2 2-4 4-6 6-8 8-10 10-12
14
Tester
Static Electricity Measuring Instrument
STATIRON
Static Field Meter
STATIRON DZ4 Application Example
Check the charge condition of film, resin, etc.
DZ4
ESD check at the assembling process line
Check the ion balance of the ionizer

Angle of the rotary sensor head 180 degree


(hold each 45 degree)

Ground cable

Strap

Unit Electrostatic Measurement Plate (optional) DZ4 plate (optional) Soft storage case
Model: ODZ4-HPLT Model name:ODZ4-PLT (standard accessory)
Can measure static electricity in human bodies for ion balance measurement

Dimension Diagram Specifications


Model DZ4
Pointer
Signal detection method Oscillating chopper *1
Sensor
Frequency of data indication Each 0.5 second
Measurement range Normal mode: 0.01~19.99kV
I.B mode: 0.001~1.999kV
Display Panel Measurement distance 30mm (between measurement object and sensor)
Measurement distance adjust Red Light focusing system
Angle of the rotary sensor head 180 degree (hold each 45 degree)
0-point Adjustment
Indicator LED indicator with back light
Polarity display Both positive and negative polarity
Mode select With MODE select button
Battery check Indicate in LED indicator
POWER MODE HOLD 0ADJ
Power supply DC 9V alkaline battery 006P
MADE IN JAPAN

FAN
Operating Environment 0~40°C
Main unit dimensions 66×22×138mm (W×D×H)
Wight 160g
Hold Accessories 9V battery, soft storage case, Grounding Cable,Strap
Battery Box Cover Grounding Terminal Mode Select (Unit: mm) *1. The oscillating chopper is very susceptible to shock such as being dropped. Take care
Power
not to subject when using it.

15
Tester
Static Electricity Measuring Instrument
STATIRON
Handy Type Charged Plate Monitor
STATIRON DP Application Example
Characteristics evaluation of various ionizers
DP

Angle of the rotary sensor head 180 degree


(hold each 45 degree)

AC adapter (optional) Soft storage case (standard accessory)

Main Features
Ionizer Checking As handy type of CPM function, can check the ion balance and
decay time of ionizers.Impressed 1000V onto the plate and
measure the decay time up to 100V.

Dimension Diagram Specifications


Model DP
Charged plate
Signal Detection Method Oscillating Chopper *1
Five phases of adjustment Plate Size 70×32mm (IEC standard 150×150mm)
31

45° Plate Capacity


45° 10pF ±10%
Measuring Accuracy ±10%rdg ± 2 digit
45°

45°

Measuring Voltage Range 0~±1999V


Start Measuring Time range 0.0~99.9 sec
0-point
Adjustment Angle of Rotary head 180 degree (hold each 45 degree)
Mode Select AC adapter Battery Check Indicate in LCD indicator
input jack

Power Supply Two 1.5V DC AA-type alkaline battery or AC adaptor


(〈174〉

MADE IN JAPAN Weight 240g


Main Unit Dimensions 70x174x30mm (W×H×D)
Accessories 1.5VDC AA-type battery (2pcs), Soft case, Grounding cable
Start button
Grounding Terminal
OPEN
Operation Environment 0~40°C *2
Optional Part AC Adaptor (ODP-ADP) for AC100~240V
Strap Terminal
70 24.5
30
Battery Box Cover *1 The occilation chopper is very susceptible to shock such as being dropped. Take care
not to subject it to strong shock when using it.
*2 Under high humidity environment as over 60% humidity, it will cause the problem to
charge the high voltage onto the plate

16
Tester
Resistance Measuring Instrument
Antistatic Shoe Leakage Measuring Instrument
SHOE TESTER SHOE TESTER

Application Example (Support pole is optional)


Semiconductor manufacturing plants
Paint plants
Plants where hazardous products such as solvents or powder are
handled and the wearing of antistatic shoes is required.
Dimension Diagram
170
140

AC adapter input jack Measuring data output terminal


350

310
535

Measurement input terminal


Measurement Terminal
Ground terminal

Specifications
850

Model SHOE TESTER


Support pole
Measurement method Resistance measurement using a transistor DC converter,
analog comparison method
Footplate
Measurement voltage 10VDC
(Unit: mm) Measurement accuracy ±10%+2digits
Measurement range
Main Features 0.00~200.0MΩ
Display 3-1/2 digit red LED display, automatic decimal point setting
The SHOE TESTER is a dedicated measuring instrument that Limit Upper limit value 1MΩ / 5MΩ / 10MΩ / 20MΩ / 35MΩ / 50MΩ / 100MΩ
measures the electrical resistance of antistatic shoes designed to settings Lower limit value 0.1MΩ / 0.5MΩ / 1MΩ / 5MΩ / 10MΩ
eliminate static electricity from the human body, while the shoes Cannot settings upper and Lower limit value
Alarm The green lamp is lit during normal recording
are being worn. To perform measurement, the person wearing the
Upper limit value The red lamp lights and a buzzer (with on/off switch) sounds
shoes stands on the base and operates the instrument simply by Lower limit value The red lamp lights and a buzzer (with on/off switch) sounds
pressing the touch panel with one finger. Function check Ohm check switch, 0.95~1.05MΩ
A resistance of 100 MΩ or less to ground is required to eliminate Battery check Push-button method
static electricity from the human body, and at least 0.1 MΩ is Power supply DC12V ACadapter (100~240AC)
desired for the prevention of electrical shock. Since the resistance Operating Environment 0~40°C
Dimensions Main unit: 170×140×37 (W×H×D)
of the shoes will vary depending on the temperature and humidity, Measurement stand: 310×350×30mm (W×D×H)
dirt on the shoe soles, and friction, periodic measurement and Weight Main unit 0.9kg Measurement plate 4.5kg
maintenance is required. Measurement stand 1.2kg

For Both legs Check Power Switch


Fixing Bracket Cable connector (to Body)
350
167
177

310
27

Toutch Plate
170

INPUT Wrist Strap Shoe

Power Connector Mode select switch


Grounding Terminal RS232C terminal Self Check button
Measuring instrument Measuring table OK/NG Output terminal
Cable connector (to Plate)
Low limit setting Dial Upper limit setting Dial

17
Tester
Electric Charge Attenuation Measuring Instrument
Tester Electric Charge Attenuation Measuring Instrument
STATIC HONESTMETER H-0110-S4 H-0110-S4
The standard height of the STATIC HONESTMETER probe is 20mm. The probe size can be changed to 15mm to meet
the Japanese Industrial Standard (JIS). Please specify this at the time of order.

Analyzer connector

Please specify either 50 or 60 Hz. Safety cover is now Standard accessory with
Only AC100V available! Safety Interlocked function
If necessary, we will provide Stable transformer with AC100V output.

Main Features Dimension Diagram


The STATIC HONESTMETER is an instrument designed to
measure the attenuation of static electricity, and is the ideal device
for measuring the diffusibility of static in materials. This device is
used to charge the sample by irradiating it with air ions generated
by a corona discharge, and, after irradiation has stopped, to
measure the static decay curve.
(Unit: mm)

Specifications
Model H-0110-S4
15 Note 1

Input Voltage 100VAC ±10% (50/60Hz) *1 80


70
80
70
175

High-voltage H.V.(applied voltage for corona discharge): 0~10kV


60 60
50 50
40 40
30 30

Power supply output CAL (applied voltage for calibration): 0~3kV 20


10
0
20
10
0

Operating temperature range 0~40°C


Operating humidity range 20~90% RH (non-condensing)
TYPE H-0110
STATIC HONESTMETER
Output signals ANALYZER terminal: for the analyzer AUTO MANUAL

Voltage: 0~±10V MEASURE


CAL
H.V.
CAL H.V. ADJ
5

Accuracy: Approx. 10%


4 6
7
3

Accuracy: Approx. 10%


283
2

SYNC
9
1

Main unit dimensions 420×450×280mm (W×H×D)


0 10

Weight Approx. 33kg


FUSE

MAIN MOTOR H.V


ANALYZER
ON ON ON

Accessories Power supply cord, signal cable OFF OFF OFF

calibration jig and balancer (one set)


hexagonal wrenches (2), 2A fuse (3)
420 280
*1 Please specify at the time of purchase 50Hz/60Hz. It does not correspond to
the different voltage. Note 1) Probe height at the time of calibration

Device Configuration and Operation Fig. 1


Power application section
Fig. 2
Specimen attachment frame (needle electrode)
As shown in Fig. 1, this device comprises V0
B C
Voltage OFF
Equilibrium
a power application section where corona

Indicator Decay curve


discharge is used to charge the sample V=V0 exp{−t/
(RL・C)}
DC high voltage
Potential V

Analyzer
(specimen) as desired, a turntable on which V0/2
D

the specimen is placed for rotation, and a


power receiving section for detecting the Arm Half lifeτ E
potential of the sample. The operation of the 00
A t1 t2 (t →)
Time
device is shown in Fig. 2.
Scale
Power receiving section Turntable

18
STATIC HONESTMETER
HONEST DATA ANARYZING SYSTEM V2-S1 V2-S1
HONESTMETER HONEST PC
DATA ANALYZEEING SYSTEM V2-S1 *PC is not included, the software is include with Model V-2.

Main Features
The HONEST DATA ANALYZEEING SYSTEM V2-S1 is an Measurement data graph display screen
analysis and calculation device designed to automatically
calculate the half life of the voltage decay from the static Control screen buttons and parameter settings
decay curve obtained from the HONESTMETER device. The
attenuation of materials can be automatically measured by a
one-touch operation.
Decay rate setting: 2~100% decay
Digital data storage (CSV file data)
Voltage axis
Automatically operation

Charging
Dimension Diagram characteristic
curve

Half-life
measured
voltage

Attenuation
characteristic
HONEST DATA ANARYZING SYSTEM V2

curve
Half-time Time axis
Sensor unit connector Date, temperature and humidity
Power switch
(Unit: mm)
250 Fuse Date (automatic entry)
30 Power supply
connection plug
SENSOR POWER [Measurements] temperature
30

ON OFF

1A

[Measurements] humidity
TO HONEST
100

POWER

GND
USB
30

Basic Configuration
Power lamp USB connector
HONEST terminal
Ground terminal

Measurement mode setting

Specifications Measurement time setting

Model V2 -S1
Input Voltage AC 100~240V±10%(50/60Hz) % Half-life setting
Capacity 0.5VA
Main unit dimensions 300×250×100mm(W×H×D) [Measurements]
maximum charging voltage
Weight Approx. 1kg
Operating environment Supported model of real / HV Time when
DOS/V computer with a USB interface Application time setting
Intel Pentium 500 MHz or faster (or equivalent) Measurement data of
At least 128 MB of memory recommended, depending half-rate is specified
on the capacity required by the OS [Measurements] Decay time of
• Hard disk drive (HDD): At least 2 GB of available space the half-rate set at the time
• Screen resolution: 1024 × 768 or greater recommended [Measurements] Voltage setting
Operating systems (OS) of half-time rate
Windows Vista (32bit) Measurement data in the
Windows XP (SP2 or later, 32bit) specified time period
Windows 7 (32bit/64bit) Measurement time setting
Windows 8 (64bit)
[Measurements] Voltage at the
Accessories Power supply cord, connection cable time of setting measurement time
USB cable, Temperature/humidity sensor,
CD-ROM(Manual and drivers), Stand
19
High-voltage Power Supplies
Configuration of the Safety Device
The over-current detection section is a device that detects an over- Model Current setting for abnormality detection
current by measuring the current returned to the secondary ground
SAT-11 Upper limit 2.5 mA constant
terminal on the high-voltage transformer and comparing it with the
reference input value. SAT-20 3 settings; 2, 3.5, or 5 mA
When it detects an abnormal leakage current on the static- SAT-30 SAT-30 Digital setting enabled up to 5mA in 1μA increments
eliminating electrode or a high-voltage cable, the safety device
stops the high-voltage power supply and displays an alarm.

Safety device meeting Product Liability standards


ELIMINOSTAT SAT Series
A safety device detects an abnormal leak electric current and
stops a high pressure power supply
Powered-up and Abnormal Alarm Output
ELIMINOSTAT SAT-11
SAT Series
Static Eliminator Connection Example
High-voltage cable
(for connecting the static-eliminating electrode)

High-voltage cable
(for connecting the high-voltage power supply)

ELIMINOSTAT
HIGH-VOLTAGE
AC POWER SUPPLY

OUTPUT
indicator

ABNORMAL
NORMAL

High-voltage power supply (SAT-11)

High-voltage branch box

■Please use the following calculation formulae to configure your system.

SAT-11/AT-10 【Total electrode length】


+【Total cable length】
≦8m
SAT-20/SAT-30 【Total electrode length】
≦10m+
【Total cable length】
≦12m
*The length of the branch box is calculated as 1m, and the length of the AP-5, AG-5, and FAPS-GP
 electrodes as 0.5 m.
*Please make sure the limited length of cable and bar before using. Because when
 over-length using will cause alarm of SAT series.

Main Features Dimension Diagram


The ELIMINOSTAT SAT Series comprises a static-eliminating 90 110
4-φ5.4 fixing hole
electrode, a high-voltage power supply, high voltage cables and a 70 Main unit 25

high-voltage branch box for connecting the system units. Normal operation
38

indicator lamp
The SAT Series static eliminators are provided with a safety device Abnormal operation
indicator lamp
that meets standards proscribed under the Product Liability Law.
This safety device incorporated in the SAT Series high-voltage ELIMINOSTAT
HIGH-VOLTAGE
AC POWER SUPPLY
High-voltage
output terminal
180
200
220

power supplies is an over-current protector that cuts off the high- Power switch

voltage power supply when an abnormal current is detected in the OUTPUT


indicator 200V
 
100V

electrode or in the high-voltage cables.


ABNORMAL
NORMAL

14

Power supply
Power supply cord (cord length: 2000 mm) connection plug
2000±50 Ground terminal Input voltage
selector switch
Abnormal operation
output terminal

20 2000±50 (Unit : mm)

20
ELIMINOSTAT
ELIMINOSTAT SAT-20 ELIMINOSTAT SAT-30 ELIMINOSTAT AT-10

Dimension Diagram
Output current meter
Current upper limit setting knob
Current lower limit setting knob
Output current
Main unit Output current meter setting terminal 4-φ5.4 fixing hole High-voltage
150 180 Main unit output terminal 25
High-voltage
Power switch output terminal
Main unit

38
OUT PUT CURRENT
Fuse 150 Reset switch 180
High-voltage Input voltage
Ground terminal Power switch output terminal ELIMINOSTAT
HIGH-VOLTAGE
AC POWER SUPPLY
Power switch selector switch
OUTPUT CURRENT
Fuse Fuse box
Power cord Ground terminal

220
200
180
OUTPUT
220

Ground terminal
Indicatar POWER
ON
ABNORMAL NORMAL

OFF
Power cord
BUZZER
ON OUTPUT POWER
indicator RESET
220

FUSE ON
ON
ABNORMAL NORMAL
POWER
FUSE

OFF

OFF
OFF

ELIMINOSTAT
HIGHVOLTAG
AC POWER SUPPLY

14 110
FUSE

15 1800 Input voltage


10

70 116
selector switch
ELIMINOSTAT

Normal operation
HIGHVOLTAG

90 1800
AC POWER SUPPLY

indicator lamp Abnormal operation


alarm terminal 15 1800 Rubber Input voltage Power cord
10

Abnormal operation (Unit : mm)


Rubber foot foot selector switch (cord length: 1800 mm ± 50)
indicator lamp (Unit : mm) Normal operation
indicator lamp Buzzer
Abnormal operation
Abnormal operation alarm terminal
indicator lamp
Buzzer switch (Unit : mm)

High-voltage Cables High-voltage Branch Boxes


SAT-ECS-A1 HVB
HVB-5 HVB-4 HVB-3 HVB-2 HVB-1

500mm (SAT-ECS500-A1)
1000mm (SAT-ECS1000-A1)
Ground
1500mm (SAT-ECS1500-A1) terminal
2000mm (SAT-ECS2000-A1) High-voltage
connection terminal
2-φ5.2 fixing hole
Male SAT connector φ20 27.5 110 15 27.5 82.5 15 27.5 55 15 27.5 27.5 15
Case Main unit case
Flexible high-voltage (Color: black) 15
15

15

15

15

cable
75

75

75

75

2-φ5.2
60

L
37.5

37.5

37.5

37.5

fixing hole
10
30

L=500mm
170 1.2 143 1.2 116 1.2 88 1.2 88 1.2
1000mm 182 30 155 30 128 30 100 30 100 30
1500mm 194 167 140 112 112
2000mm
(Unit : mm) (Unit : mm) (Unit : mm) (Unit : mm) (Unit : mm) (Unit : mm)

Specifications
Model SAT-11 SAT-20 SAT-30 AT-10
Input power supply 110~120VAC or 220~240VAC (switch-selectable)
HV power supply used Commercial frequency alternating current power supply (wire wound high-voltage power supply)
Maximum 5.0mA (2mA, 3.5mA, 5mA Maximum 5.0mA (upper and lower
Allowable output current 2.5mA 2.3mA
switch-selectable settings) limits settable in 1μA units)
Operating Environment 0 to 40°C
Main unit dimensions 90×220×110mm (W×H×D) 150×230×180mm (W×H×D) 150×230×180mm (W×H×D) 90×220×110mm (W×H×D)
Weight 3600g 6000g 6000g 3800g
Alarm functions LED indication when a high-voltage abnormality or shutdown occurs -
Allowable length for
8 meters in total Electrode length: 10m; cable length: 12m 8 meters in total
connecting electrodes/wiring
Power supply cord (100 VAC Metallic connector for alarm output; protective bushing for high-voltage
Accessories -
3P-plug) (cord length: 2000mm) output; 3-pin adapter
AT-10 is not provided with the safety device.
21
Electrodes
AC Voltage Application Method Static Eliminators
Bar electrode for small spaces Dimension Diagram

BJS
40 20

Bar Electrode ELIMINOSTAT Emitter Needle (Stainless)


Main Body (ABS)
(Standard cable length : 1m)

12
20 10 L-20

25
22.5 L
Fixing Hole 2-φ5.2
Grounding Terminal (Aluminium)
(Unit: mm)

Bar electrode for long-length applications Dimension Diagram (Unit: mm)

BOS
BOS (Length less than 1300 mm) High-voltage connector
High-voltage shielded cable

Bar Electrode ELIMINOSTAT

36
25
32.5 25 50
(Standard cable length : 1m) Grounding plate
L
32.5 1000

45
Emitter needle Intermediate flange
Flange at both ends Mounting bracket 15

BOS (Length exceeding 1300 mm) High-voltage connector


4-φ5.2 High-voltage shielded cable

35
20
7.5 50 50 1000
Grounding plate
20 L 20 34.5

(47)
22
20
Flange at both Intermediate flange Emitter needle 35
ends Reinforcing plate (41)
Ground connection plate

Bar electrode for small spaces Dimension Diagram

BICS
15
Emitter needle High-voltage shielded cable

Bar Electrode ELIMINOSTAT


(Standard cable length : 1m) 30・40 20 40 1000
φ22

High-voltage
connector
L

Mounting Main unit Grounding wire


bracket

(Unit: mm)

Bar electrode for small spaces Dimension Diagram

BUAS
DM joint for 4×6φ tube Ion air blowout nozzle High-voltage shielded cable

Air Electrodes ELIMINOSTAT


15

50 12.5 37.5 1000 60


(Standard cable length : 1m) L High-voltage connector

1. L<800 Main unit Grounding wire

φ20

10
4

2-φ4.2 through-hole 10
L 1000

Grounding wire
2. 800≦L<1500
30

3. 1500≦L≦1800

L
(Unit: mm)

Electrode with flat nozzle Dimension Diagram

FAPS-GP
72

Air Electrodes ELIMINOSTAT


42

(Standard cable length : 1m)


30

φ4.5
1000
50

High-voltage
φ20

connector

High-voltage shielded cable


134
One-touch air joint (φ6) (Unit: mm)

22
1. Designed to be used for eliminating static from film, sheets, paper and so forth

ELIMINOSTAT
2. Low-sensitivity construction to minimize electric shock
3. The length of the standard high-voltage cable is 1 m.
4. The optimum installation location of the bar type electrode is at a distance of
30 to 50 mm away from the charged object (when air is not used).
5. The maximum static elimination speed with respect to the charged object is
120 m/min.

Electrode with pointed nozzle Dimension Diagram 10

AP-5

32
Air Electrodes ELIMINOSTAT Emitter needle
52
2-φ4.2 elongated hole

4
φ26 62 Electrode main unit

φ
(Standard cable length : 1m or 2m)

28
High-voltage connector
One-touch air joint

With Nozzle Cap A With Nozzle Cap B


High-voltage shielded cable (Unit: mm)

Ion air gun Dimension Diagram

AG-5
Electrode main unit Emitter needle

Air Electrodes ELIMINOSTAT


Air gun (165) 33

High-voltage

φ26
connector
(Standard cable length : 2.5m or 5m) Rubber band

133
Hand grip

36
Hose joint (φ9)
With Nozzle Cap A With Nozzle Cap B High-voltage shielded cable(2500-mm length)
(Unit: mm)

Bar electrode for long-length applications Dimension Diagram

ALS
L
50 25 50 1000

Air Electrodes ELIMINOSTAT


φ32
(Standard cable length : 1m) Ion air blowout opening High-voltage High-voltage
shielded cable connector
15
)

Ground pin
32

60
15

Emitter needle
Bushing
Metal ring φ32 One-touch air joint (φ6)
(Accessories) (Unit: mm)

Static Eliminator with Integral Power Supply


DC Voltage Application Method Static Eliminators

DC-ESR-C
Principle of Static Elimination
ELIMINOSTAT DC Voltage +7KV
DC Voltage -7KV

Ion Alarm LED


Adaptor for connected specification (optional)
1.To two electrodes at the connection : The AD-02 type.
2.To six electrodes at the connection : The AD-06 type.

Main Features AC adapter(option) Static elimination area


The DC-ESR-C is a bar ionizer that uses the corona discharge When the air downflow velocity is 0.3 m/s
1000
method to generate air ions. Air containing positive and negative 400mm
600mm
ions effectively neutralizes the load on a charged object. With its 800mm
Charged voltage (V)

750 1000mm
low dust-emission design, this device is suitable for controlling
ions in clean rooms and on clean benches. Since a small DC 500
power supply is incorporated in the bar electrode, the device
does not require a high-voltage cable. The safety design uses 250
only low-voltage wiring, unlike other devices that require an
external high-voltage power supply and high-voltage cables. 0
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 6 7 8 10 12 14
Specifications Serial connector Static decay time (sec)
Dimension Diagram
Model DC-ESR-C 10
Mounting hole

Input power supply 24VDC (AC adapter supplied; compatible with 100~240 VAC)
External dimensions 32×50×600, 800, 1000, 1200, 1400, 1600 or 1800mm(W×H×D) Power supply I/O terminal Ion balance adjustment kno 16
Emitter needle cover -Output indicator lamp 10 32
Weight 0.24kg (when L = 600mm) 20 +Output indicator lamp
Ion balance Adjustment function provided
50
4
1 9

Static charge discharge time 2.1s *1 P100 200 P100 16 Power supply
L-40 input/output
Amount of ozone generated 0.015ppm or less *2 L-20 Cover terminal
L
Material of Emitter Tungsten (can be changed to single-crystal silicon as an option) Emitter needle AC adapter main unit Power supply input terminal
Operating temperature range 0~50°C The standard L dimensions are 600, 1000, and 1400 mm.
Option AC adapter The maximum L dimension is 2000 mm. 1800±50
Number of emitter needles
*1 Measured using a CPM measurement device (conforms to ESD.STM 3.1-2000) With the ion balance in a steady state, the static decay time L =600 to 999 mm: 4 needles(2 for +high-voltage output; 2 for -high-voltage output)
is the time taken to decay from +1000 V to +100 V. Data obtained using the following parameters: Airflow: 0.2 MPa, Distance: 300 mm, Ion (Unit: mm)
L =1000 to 1399 mm: 8 needles(4 for+high-voltage output; 6 for -high-voltage output)
balance setting: B *2The ozone density was measured at a distance of 50 mm from the main unit's air outlet. L =1400 to 2000 mm: 12 needles (6 for +high-voltage output; 6 for -high-voltage output)
23
Static & Dust Remover DUST HALER
Compact size Air Ionizer
DUST HALER Trz:CuBe/Flt:CuBe/Trz: Maxi

Trz:CuBe Flt:CuBe Trz: Maxi

Dimension Diagram Main Features


With Strong Vacuum fan, correct the particle that blown away
Fan speed adjustment volume inside box. (Trz:Cube, Trz:Maxi)
ON Time Pulse mode Strong Air blow nozzle at up and down side.
Configuration Changing-over Installed three nozzles two for upper sides
switch switch one for down side.
OFF Max Min
Time Pulse Installed SSD HDC-AC Ionizer and perform Upper nozzle
Power switch
Real

3sec
1Hz

3Hz
fast decay performance.
FAN Speed
15sec
10sec
5sec Cont
10Hz
5Hz Easy operation by timer controlled air blow.
Blow Mode Setting Effective Four kinds of pulsed air blow
Indicator light Attached additional Filter (1 pc)
Ready RUN ION FAN Working You can chose non-fan vacuum type(Flt:CuBe)
IONIZER ALARM in case you haveindependent vacuum system. Lower nozzle
work insertion blow nozzle display panel 8 quick fitting
slot IONIZER power cord inlet knurled screw Specifications
body of plate regulator ground terminal external suction
filter setting and fuse box port Model Trz:Cube Flt:Cube Trz:MaXi
Input Voltage AC100V~240V(50/60Hz) ±10%
Pulse
1Hz

3Hz

Electric Consumption Maximum 240W Maximum 50W Maximum 240W


MADE IN JAPAN
5Hz

Working

Trz:Cube
10Hz
Blow Mode Setting
Cont

FAN
ALARM

Discharge Method: HDC-AC


ION
Real

3sec
Time

5sec

RUN
IONIZER
10sec

Ionizer Specifications Ion Balance: Below ±30V


Ready
15sec
Min

FAN Speed

Decay time: Below 1 second (0.6MPa air pressured)*1


DUST HALER
Max
OFF
ON

Supplied Air CDA (Clean and dried air) *2


⑬ ⑥
⑦ ⑤ Available Air pressure 0.2MPa~0.6MPa*3
46

④① Size of air fitting Diameter 8mm


Air Blow nozzle Upper side: 2units(Angle adjustable) Upper side: 2units(Hight adjustable)
Down side: 1unit Down side:1unit(ON/OFF avairable)
166(ワーク間口)

Filter Specification Correct 98% of the particle over 10 μm


360


Air Blow Pulse setting 1Hz, 3Hz, 5Hz, 10Hz, Cont
Air Blow Time setting 3 sec, 5 sec, 10 sec, 15 sec, Real
94

⑫ Fan Speed Non-step adjustable


⑧ ⑪ 280(Workspace depth) 180 Foot Switch/Sensor/Continuously Blow Selector
10

360
② 222(Work frontage) Additional Function -
⑨ ⑩ 400 225 Slide Table

Trz:Maxi Air Consumption 270ℓ/min ANR (at 0.3MPa Cont setting) 300ℓ/min ANR (at0.3MPa Cont setting)
Vacuum System Fan Dust Corrector Fan
Sound Level Minimum fan speed:51dBA 50% Fan speed: 74dBA
Dimensions 225x360x400mm(WxHxD) 425x370x425mm(WxHxD)
Weight Approx. 9kg Approx. 8.5kg
Available environment 0~40°C / 15~85%RH (without condensation)
OFF
ON

Accessories Manual, Power Cable, Filter, FootSwitch(Maxi only)


Option Part Filter (5 piecs): Trz-RKF05 Filter(5piece):Trz-MXF05
*1 Checked by CPM with 150x150mm plate (20pF), Decay time is from ±1000V to ±100V.
*2 Supplied air must be Clean and Dry, the air contaminated with moisture or oil will
makes damage to the ionizer.
*3 Setting level of the air regulator

In the interests of product improvement, specifications and product appearance are subject to change without notice.

http://www.shishido-esd.co.jp/
Overseas Department, Tokyo Branch Shishido Bldg, 1-3-3 Higashi-Yukigaya, Ota-ku, Tokyo 145-0065
Tel: +81-3-3727-0162 Fax: +81-3-3727-0342
Head Office 9F-918, Marunouchi Bldg, 2-4-1 Marunouchi, Chiyoda-ku, Tokyo 100-6309

15.11NY Printed with environmentally friendly soy ink on 100% recycled paper