You are on page 1of 357

ZXWN MSCS

MSC Server
Timer Reference Ⅰ

Version: V4.10.13

ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
Copyright © 2010 ZTE CORPORATION.

The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.

All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.

This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular
purpose, title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages
resulting from the use of or reliance on the information contained herein.

ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter

herein.

ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further
notice. Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History

Revision No. Revision Date Revision Reason


R1.0 2011-2-28 First edition

Serial Number: SJ-20101208143956-020

Publishing Date: 2011-2-28(R1.0)


Contents
———————————————————————————————————————————

Chapter1 Timers Related with SCCP Module.................................................... 1-1


1.1 Timer 40191 ............................................................................................. 1-1
1.2 Timer 40192 ............................................................................................. 1-1
1.3 Timer 40193 ............................................................................................. 1-2
1.4 Timer 40194 ............................................................................................. 1-2
1.5 Timer 40195 ............................................................................................. 1-3
1.6 Timer 40196 ............................................................................................. 1-3
1.7 Timer 40197 ............................................................................................. 1-4
1.8 Timer 40198 ............................................................................................. 1-4
1.9 Timer 40199 ............................................................................................. 1-4
1.10 Timer 40200 ........................................................................................... 1-5
1.11 Timer 40201 ........................................................................................... 1-5
1.12 Timer 40202 ........................................................................................... 1-6
1.13 Timer 40203 ........................................................................................... 1-6
1.14 Timer 40204 ........................................................................................... 1-7
1.15 Timer 40205 ........................................................................................... 1-7
Chapter2 Timers Related with MTP3 Module .................................................... 2-1
2.1 Timer 40405 ............................................................................................. 2-1
Chapter3 Timers Related with MTP2 Module .................................................... 3-1
3.1 Timer 40595 ............................................................................................. 3-1
3.2 Timer 40596 ............................................................................................. 3-1
3.3 Timer 40597 ............................................................................................. 3-2
3.4 Timer 40598 ............................................................................................. 3-2
3.5 Timer 40599 ............................................................................................. 3-2
3.6 Timer 40600 ............................................................................................. 3-3
3.7 Timer 40601 ............................................................................................. 3-3
3.8 Timer 40602 ............................................................................................. 3-4
3.9 Timer 40603 ............................................................................................. 3-4

I
3.10 Timer 40604 ............................................................................................3-4
3.11 Timer 40605 ............................................................................................3-5
Chapter4 Timers Related with SIGTRANT Module ............................................4-1
4.1 Timer 49205..............................................................................................4-1
4.2 Timer 49603..............................................................................................4-1
4.3 Timer 49604..............................................................................................4-2
4.4 Timer 49605..............................................................................................4-2
4.5 Timer 49705..............................................................................................4-2
4.6 Timer 49804..............................................................................................4-3
4.7 Timer 49805..............................................................................................4-3
4.8 Timer 49999..............................................................................................4-4
4.9 Timer 50000..............................................................................................4-4
4.10 Timer 50001 ............................................................................................4-5
4.11 Timer 50002 ............................................................................................4-5
4.12 Timer 50003 ............................................................................................4-5
4.13 Timer 50004 ............................................................................................4-6
4.14 Timer 50005 ............................................................................................4-6
Chapter5 Timers Related with ALCAP Module ..................................................5-1
5.1 Timer 89999..............................................................................................5-1
5.2 Timer 90000..............................................................................................5-1
5.3 Timer 90001..............................................................................................5-1
5.4 Timer 90002..............................................................................................5-2
5.5 Timer 90003..............................................................................................5-2
5.6 Timer 90004..............................................................................................5-2
5.7 Timer 90005..............................................................................................5-3
5.8 Timer 90006..............................................................................................5-3
5.9 Timer 90007..............................................................................................5-4
5.10 Timer 90008 ............................................................................................5-4
Chapter6 Timers Related with GCM Module......................................................6-1
6.1 Timer 205101 ............................................................................................6-1
6.2 Timer 205102 ............................................................................................6-2
6.3 Timer 205103 ............................................................................................6-3
II
6.4 Timer 205104 ........................................................................................... 6-4
6.5 Timer 205106 ........................................................................................... 6-5
6.6 Timer 205107 ........................................................................................... 6-5
6.7 Timer 205108 ........................................................................................... 6-6
6.8 Timer 205109 ........................................................................................... 6-7
6.9 Timer 205110 ........................................................................................... 6-8
6.10 Timer 205111.......................................................................................... 6-9
6.11 Timer 205112........................................................................................ 6-10
6.12 Timer 205113 ........................................................................................6-11
6.13 Timer 205114 ....................................................................................... 6-12
6.14 Timer 205115 ....................................................................................... 6-13
6.15 Timer 205116 ....................................................................................... 6-14
6.16 Timer 205117 ....................................................................................... 6-14
6.17 Timer 205118 ....................................................................................... 6-15
6.18 Timer 205119 ....................................................................................... 6-16
6.19 Timer 205120 ....................................................................................... 6-17
6.20 Timer 205123 ....................................................................................... 6-18
6.21 Timer 205125 ....................................................................................... 6-19
6.22 Timer 205126 ....................................................................................... 6-20
6.23 Timer 205127 ....................................................................................... 6-21
6.24 Timer 205128 ....................................................................................... 6-22
6.25 Timer 205129 ....................................................................................... 6-23
6.26 Timer 205130 ....................................................................................... 6-24
6.27 Timer 205131 ....................................................................................... 6-25
6.28 Timer 205132 ....................................................................................... 6-26
6.29 Timer 205133 ....................................................................................... 6-27
6.30 Timer 205134 ....................................................................................... 6-28
6.31 Timer 205135 ....................................................................................... 6-29
6.32 Timer 205136 ....................................................................................... 6-30
6.33 Timer 205137 ....................................................................................... 6-31
6.34 Timer 205138 ....................................................................................... 6-32
Chapter7 Timers Related with LICA Module ..................................................... 7-1
III
7.1 Timer 205201 ............................................................................................7-1
7.2 Timer 205202 ............................................................................................7-2
7.3 Timer 205203 ............................................................................................7-3
7.4 Timer 205204 ............................................................................................7-4
7.5 Timer 205205 ............................................................................................7-5
7.6 Timer 205206 ............................................................................................7-6
7.7 Timer 205207 ............................................................................................7-7
7.8 Timer 205208 ............................................................................................7-8
7.9 Timer 205209 ............................................................................................7-9
7.10 Timer 205210 ........................................................................................7-10
7.11 Timer 205211 ........................................................................................ 7-11
7.12 Timer 205212 ........................................................................................7-12
7.13 Timer 205213 ........................................................................................7-13
7.14 Timer 205214 ........................................................................................7-14
7.15 Timer 205215 ........................................................................................7-15
7.16 Timer 205216 ........................................................................................7-16
Chapter8 Timers Related with LIM Module ........................................................8-1
8.1 Timer 205301 ............................................................................................8-1
8.2 Timer 205302 ............................................................................................8-2
8.3 Timer 205303 ............................................................................................8-2
8.4 Timer 205304 ............................................................................................8-3
8.5 Timer 205305 ............................................................................................8-4
8.6 Timer 205306 ............................................................................................8-4
8.7 Timer 205307 ............................................................................................8-5
Chapter9 Timers Related with PBRT Module ....................................................9-1
9.1 Timer 205401 ............................................................................................9-1
9.2 Timer 205402 ............................................................................................9-1
9.3 Timer 205403 ............................................................................................9-2
9.4 Timer 205404 ............................................................................................9-3
9.5 Timer 205405 ............................................................................................9-3
Chapter10 Timers Related with SIPCM Module...............................................10-1
10.1 Timer 205501 ........................................................................................10-1
IV
10.2 Timer 205502 ....................................................................................... 10-1
10.3 Timer 205503 ....................................................................................... 10-2
10.4 Timer 205504 ....................................................................................... 10-2
10.5 Timer 205505 ....................................................................................... 10-3
10.6 Timer 205506 ....................................................................................... 10-3
10.7 Timer 205507 ....................................................................................... 10-4
10.8 Timer 205508 ....................................................................................... 10-4
10.9 Timer 205509 ....................................................................................... 10-5
10.10 Timer 205510 ..................................................................................... 10-6
10.11 Timer 205511...................................................................................... 10-6
10.12 Timer 205512 ..................................................................................... 10-7
Chapter11 Timers Related with SORMUP Module ...........................................11-1
11.1 Timer 205601 ........................................................................................11-1
11.2 Timer 205602 ........................................................................................11-1
11.3 Timer 205603 ........................................................................................11-2
11.4 Timer 205604 ........................................................................................11-3
11.5 Timer 205605 ........................................................................................11-4
11.6 Timer 205606 ........................................................................................11-4
Chapter12 Timers Related with TCM Module.................................................. 12-1
12.1 Timer 205701 ....................................................................................... 12-1
12.2 Timer 205702 ....................................................................................... 12-1
12.3 Timer 205703 ....................................................................................... 12-2
12.4 Timer 205704 ....................................................................................... 12-2
12.5 Timer 205705 ....................................................................................... 12-3
12.6 Timer 205706 ....................................................................................... 12-4
12.7 Timer 205707 ....................................................................................... 12-4
12.8 Timer 205708 ....................................................................................... 12-5
12.9 Timer 205709 ....................................................................................... 12-5
12.10 Timer 205710 ..................................................................................... 12-6
Chapter13 Timers Related with SPS Alarm Module ....................................... 13-1
13.1 Timer 205801 ....................................................................................... 13-1
13.2 Timer 205802 ....................................................................................... 13-1
V
13.3 Timer 205803 ........................................................................................13-2
13.4 Timer 205804 ........................................................................................13-2
Chapter14 Timers Related with Public Processing Module ...........................14-1
14.1 Timer 205901 ........................................................................................14-1
14.2 Timer 205902 ........................................................................................14-1
14.3 Timer 206303 ........................................................................................14-2
14.4 Timer 208102 ........................................................................................14-3
14.5 Timer 208103 ........................................................................................14-3
Chapter15 Timers Related with ISDN Module..................................................15-1
15.1 Timer 208502 ........................................................................................15-1
15.2 Timer 208503 ........................................................................................15-2
15.3 Timer 208504 ........................................................................................15-3
15.4 Timer 208505 ........................................................................................15-4
15.5 Timer 208506 ........................................................................................15-6
15.6 Timer 208507 ........................................................................................15-7
15.7 Timer 208508 ........................................................................................15-8
15.8 Timer 208509 ........................................................................................15-9
15.9 Timer 208510 ...................................................................................... 15-11
15.10 Timer 208511 .................................................................................... 15-11
15.11 Timer 208512 ....................................................................................15-12
15.12 Timer 208513 ....................................................................................15-13
15.13 Timer 208514 ....................................................................................15-14
15.14 Timer 208515 ....................................................................................15-15
15.15 Timer 208516 ....................................................................................15-15
15.16 Timer 208517 ....................................................................................15-16
15.17 Timer 208518 ....................................................................................15-16
15.18 Timer 208519 ....................................................................................15-17
15.19 Timer 208520 ....................................................................................15-18
15.20 Timer 208521 ....................................................................................15-19
15.21 Timer 208522 ....................................................................................15-21
15.22 Timer 208523 ....................................................................................15-22
15.23 Timer 208524 ....................................................................................15-23
VI
Chapter16 Timers Related with CAS Module .................................................. 16-1
16.1 Timer 208601 ....................................................................................... 16-1
16.2 Timer 208602 ....................................................................................... 16-2
16.3 Timer 208603 ....................................................................................... 16-3
16.4 Timer 208604 ....................................................................................... 16-4
16.5 Timer 208605 ....................................................................................... 16-5
16.6 Timer 208606 ....................................................................................... 16-6
16.7 Timer 208608 ....................................................................................... 16-7
16.8 Timer 208610 ....................................................................................... 16-8
16.9 Timer 208613 ....................................................................................... 16-9
16.10 Timer 208614 ....................................................................................16-10
16.11 Timer 208615 ....................................................................................16-11
16.12 Timer 208616 ....................................................................................16-12
16.13 Timer 208617 ....................................................................................16-13
16.14 Timer 208618 ....................................................................................16-14
16.15 Timer 208619 ....................................................................................16-15
16.16 Timer 208620 ....................................................................................16-16
16.17 Timer 208621 ....................................................................................16-17
16.18 Timer 208622 ....................................................................................16-18
16.19 Timer 208623 ....................................................................................16-20
16.20 Timer 208624 ....................................................................................16-21
Chapter17 Timers Related with AGR Module.................................................. 17-1
17.1 Timer 208651 ....................................................................................... 17-1
17.2 Timer 208652 ....................................................................................... 17-2
17.3 Timer 208653 ....................................................................................... 17-3
17.4 Timer 208654 ....................................................................................... 17-4
17.5 Timer 208655 ....................................................................................... 17-4
17.6 Timer 208656 ....................................................................................... 17-5
17.7 Timer 208657 ....................................................................................... 17-6
17.8 Timer 208658 ....................................................................................... 17-7
17.9 Timer 208659 ....................................................................................... 17-8
17.10 Timer 208660 ..................................................................................... 17-9
VII
17.11 Timer 208661 ....................................................................................17-10
17.12 Timer 208662 .................................................................................... 17-11
17.13 Timer 208663 ....................................................................................17-12
17.14 Timer 208664 ....................................................................................17-13
Chapter18 Timers Related with TUP Module (ITU Protocol)...........................18-1
18.1 Timer 208701 ........................................................................................18-1
18.2 Timer 208702 ........................................................................................18-3
18.3 Timer 208703 ........................................................................................18-4
18.4 Timer 208704 ........................................................................................18-6
18.5 Timer 208705 ........................................................................................18-7
18.6 Timer 208706 ........................................................................................18-8
18.7 Timer 208707 ........................................................................................18-9
18.8 Timer 208708 ......................................................................................18-10
18.9 Timer 208709 ...................................................................................... 18-11
18.10 Timer 208710 ....................................................................................18-12
18.11 Timer 208711 ....................................................................................18-13
18.12 Timer 208712 ....................................................................................18-14
18.13 Timer 208713 ....................................................................................18-15
18.14 Timer 208714 ....................................................................................18-16
18.15 Timer 208715 ....................................................................................18-17
18.16 Timer 208716 ....................................................................................18-18
18.17 Timer 208717 ....................................................................................18-19
18.18 Timer 208718 ....................................................................................18-20
18.19 Timer 208719 ....................................................................................18-21
18.20 Timer 208720 ....................................................................................18-22
18.21 Timer 208721 ....................................................................................18-23
18.22 Timer 208722 ....................................................................................18-24
18.23 Timer 208723 ....................................................................................18-25
18.24 Timer 208724 ....................................................................................18-26
18.25 Timer 208725 ....................................................................................18-28
18.26 Timer 208726 ....................................................................................18-29
18.27 Timer 208727 ....................................................................................18-30
VIII
18.28 Timer 208728 ....................................................................................18-31
18.29 Timer 208729 ....................................................................................18-32
18.30 Timer 208730 ....................................................................................18-33
18.31 Timer 208731 ....................................................................................18-34
18.32 Timer 208732 ....................................................................................18-35
18.33 Timer 208733 ....................................................................................18-37
18.34 Timer 208734 ....................................................................................18-37
18.35 Timer 208735 ....................................................................................18-38
18.36 Timer 208736 ....................................................................................18-39
18.37 Timer 208737 ....................................................................................18-40
18.38 Timer 208738 ....................................................................................18-40
18.39 Timer 208739 ....................................................................................18-41
18.40 Timer 208740 ....................................................................................18-41
18.41 Timer 208741 ....................................................................................18-42
18.42 Timer 208742 ....................................................................................18-43
18.43 Timer 208743 ....................................................................................18-44
18.44 Timer 208744 ....................................................................................18-45
18.45 Timer 208745 ....................................................................................18-46
Chapter19 Timers Related with TUP Module (CHINA Protocol) .................... 19-1
19.1 Timer 208751 ....................................................................................... 19-1
19.2 Timer 208752 ....................................................................................... 19-3
19.3 Timer 208753 ....................................................................................... 19-5
19.4 Timer 208754 ....................................................................................... 19-6
19.5 Timer 208755 ....................................................................................... 19-8
19.6 Timer 208756 ....................................................................................... 19-9
19.7 Timer 208757 ......................................................................................19-10
19.8 Timer 208758 ......................................................................................19-11
19.9 Timer 208759 ......................................................................................19-12
19.10 Timer 208760 ....................................................................................19-13
19.11 Timer 208761 ....................................................................................19-13
19.12 Timer 208762 ....................................................................................19-14
19.13 Timer 208763 ....................................................................................19-15
IX
19.14 Timer 208764 ....................................................................................19-16
19.15 Timer 208765 ....................................................................................19-17
19.16 Timer 208766 ....................................................................................19-17
19.17 Timer 208767 ....................................................................................19-18
19.18 Timer 208768 ....................................................................................19-19
19.19 Timer 208769 ....................................................................................19-20
19.20 Timer 208770 ....................................................................................19-21
19.21 Timer 208771 ....................................................................................19-22
19.22 Timer 208772 ....................................................................................19-23
Chapter20 Timers Related with ISUP Module (ITU Protocol) .........................20-1
20.1 Timer 208781 ........................................................................................20-1
20.2 Timer 208782 ........................................................................................20-2
20.3 Timer 208783 ........................................................................................20-3
20.4 Timer 208784 ........................................................................................20-4
20.5 Timer 208785 ........................................................................................20-5
20.6 Timer 208786 ........................................................................................20-7
20.7 Timer 208787 ........................................................................................20-8
20.8 Timer 208788 ........................................................................................20-9
20.9 Timer 208789 ......................................................................................20-10
20.10 Timer 208790 .................................................................................... 20-11
20.11 Timer 208791 ....................................................................................20-12
20.12 Timer 208792 ....................................................................................20-13
20.13 Timer 208793 ....................................................................................20-13
20.14 Timer 208794 ....................................................................................20-14
20.15 Timer 208795 ....................................................................................20-15
20.16 Timer 208796 ....................................................................................20-16
20.17 Timer 208797 ....................................................................................20-17
20.18 Timer 208798 ....................................................................................20-18
20.19 Timer 208799 ....................................................................................20-18
20.20 Timer 208800 ....................................................................................20-19
20.21 Timer 208801 ....................................................................................20-20
20.22 Timer 208802 ....................................................................................20-21
X
20.23 Timer 208803 ....................................................................................20-22
20.24 Timer 208804 ....................................................................................20-22
20.25 Timer 208805 ....................................................................................20-23
20.26 Timer 208806 ....................................................................................20-24
20.27 Timer 208807 ....................................................................................20-25
20.28 Timer 208808 ....................................................................................20-25
20.29 Timer 208809 ....................................................................................20-26
20.30 Timer 208810 ....................................................................................20-27
20.31 Timer 208811 ....................................................................................20-28
20.32 Timer 208812 ....................................................................................20-29
Chapter21 Timers Related with ISUP Module (CHINA Protocol) ................... 21-1
21.1 Timer 208821 ....................................................................................... 21-1
21.2 Timer 208822 ....................................................................................... 21-2
21.3 Timer 208823 ....................................................................................... 21-3
21.4 Timer 208824 ....................................................................................... 21-4
21.5 Timer 208825 ....................................................................................... 21-6
21.6 Timer 208826 ....................................................................................... 21-7
21.7 Timer 208827 ....................................................................................... 21-9
21.8 Timer 208828 ......................................................................................21-10
21.9 Timer 208829 ......................................................................................21-11
21.10 Timer 208830 ....................................................................................21-12
21.11 Timer 208831 ....................................................................................21-12
21.12 Timer 208832 ....................................................................................21-13
21.13 Timer 208833 ....................................................................................21-14
21.14 Timer 208834 ....................................................................................21-15
21.15 Timer 208835 ....................................................................................21-15
21.16 Timer 208836 ....................................................................................21-16
21.17 Timer 208837 ....................................................................................21-18
21.18 Timer 208838 ....................................................................................21-18
21.19 Timer 208839 ....................................................................................21-19
Chapter22 Timers Related with ISUP Module (ANSI Protocol)...................... 22-1
22.1 Timer 208841 ....................................................................................... 22-1
XI
22.2 Timer 208842 ........................................................................................22-2
22.3 Timer 208843 ........................................................................................22-3
22.4 Timer 208844 ........................................................................................22-4
22.5 Timer 208845 ........................................................................................22-5
22.6 Timer 208846 ........................................................................................22-7
22.7 Timer 208847 ........................................................................................22-8
22.8 Timer 208848 ........................................................................................22-9
22.9 Timer 208849 ......................................................................................22-10
22.10 Timer 208850 .................................................................................... 22-11
22.11 Timer 208851 ....................................................................................22-12
22.12 Timer 208852 ....................................................................................22-13
22.13 Timer 208853 ....................................................................................22-13
22.14 Timer 208854 ....................................................................................22-14
22.15 Timer 208855 ....................................................................................22-15
22.16 Timer 208856 ....................................................................................22-16
22.17 Timer 208857 ....................................................................................22-17
22.18 Timer 208858 ....................................................................................22-18
22.19 Timer 208859 ....................................................................................22-18
22.20 Timer 208860 ....................................................................................22-19
22.21 Timer 208861 ....................................................................................22-20
22.22 Timer 208862 ....................................................................................22-21
22.23 Timer 208863 ....................................................................................22-22
22.24 Timer 208864 ....................................................................................22-22
22.25 Timer 208865 ....................................................................................22-23
22.26 Timer 208866 ....................................................................................22-23
22.27 Timer 208867 ....................................................................................22-24
22.28 Timer 208868 ....................................................................................22-25
22.29 Timer 208869 ....................................................................................22-26
22.30 Timer 208870 ....................................................................................22-27
22.31 Timer 208871 ....................................................................................22-28
22.32 Timer 208872 ....................................................................................22-29
22.33 Timer 208873 ....................................................................................22-30
XII
22.34 Timer 208874 ....................................................................................22-30
22.35 Timer 208875 ....................................................................................22-31
22.36 Timer 208876 ....................................................................................22-32
22.37 Timer 208891 ....................................................................................22-33
22.38 Timer 208893 ....................................................................................22-34
22.39 Timer 208894 ....................................................................................22-34
22.40 Timer 208895 ....................................................................................22-35
22.41 Timer 200004 ....................................................................................22-35

XIII
About This Manual
———————————————————————————————————————————

Purpose

The purpose of writing this manual is to enable you to know the name, value range,
default duration, adjustment step length, flow description, and the function
description of each timer in the ZXWN MSCS system.
ZXWN MSCS MSC Server Timer Reference divides to two volumes:
z ZXWN MSCS MSC Server Timer Reference I
z ZXWN MSCS MSC Server Timer Reference Ⅱ
This manual is ZXWN MSCS MSC Server Timer Reference I.

Intended Audience

This document is intended for:


z Engineers who have basic knowledge about mobile communications
z Engineers who have known the basic structure, and basic functions of ZXWN
MSCS
z Engineers who need to know the functions and value ranges of the timers of
ZXWN MSCS.

Prerequisite Skill and Knowledge

To use this document effectively, users should have a general understanding of


wireless telecommunications technology

What Is in This Manual

This manual contains the following chapters:

Chapter Summary

Chapter 1, Timers Related with SCCP Describes the detailed information of the timers
Module related with SCCP module

Chapter 2, Timers Related with MTP3 Describes the detailed information of the timers
Module related with MTP3 module

Chapter 3, Timers Related with MTP2 Describes the detailed information of the timers
Module related with MTP2 module

I
Chapter Summary

Chapter 4, Timers Related with Describes the detailed information of the timers
SIGTRANT Module related with SIGTRANT module.

Chapter 5, Timers Related with ALCAP Describes the detailed information of the timers
Module related with ALCAP module

Chapter 6, Timers Related with GCM Describes the detailed information of the timers
Module related with GCM module.

Chapter 7, Timers Related with LICA Describes the detailed information of the timers
Module related with LICA module

Chapter 8, Timers Related with LIM Describes the detailed information of the timers
Module related with LIM module.

Chapter 9, Timers Related with PBRT Describes the detailed information of the timers
Module related with PBRT module.

Chapter 10, Timers Related with Describes the detailed information of the timers
SIPCM Module related with SIPCM module.

Chapter 11, Timers Related with Describes the detailed information of the timers
SORMUP Module related with SORMUP module.

Chapter 12, Timers Related with TCM Describes the detailed information of the timers
Module related with TCM module.

Chapter 13, Timers Related with SPS Describes the detailed information of the timers
Alarm Module related with SPS Alarm module.

Chapter 14, Timers Related with Public Describes the detailed information of the timers
Processing Module related with public processing module.

Chapter 15, Timers Related with ISDN Describes the detailed information of the timers
Module related with ISDN module

Chapter 16, Timers Related with CAS Describes the detailed information of the timers
Module related with CAS module

Chapter 17, Timers Related with AGR Describes the detailed information of the timers
Module related with AGR module.

II
Chapter Summary

Chapter 18, Timers Related with TUP Describes the detailed information of the timers
Module (ITU Protocol) related with TUP Module (ITU Protocol).

Chapter 19, Timers Related with TUP Describes the detailed information of the timers
Module (CHINA Protocol) related with TUP Module (CHINA Protocol).

Chapter 20, Timers Related with ISUP Describes the detailed information of the timers
Module (ITU Protocol) related with ISUP Module (ITU Protocol)

Chapter 21, Timers Related with ISUP Describes the detailed information of the timers
Module (CHINA Protocol) related with ISUP Module (CHINA Protocol)

Chapter 22, Timers Related with ISUP Describes the detailed information of the timers
Module (ANSI Protocol) related with ISUP Module (ANSI Protocol)

FCC Compliance Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions.

1. This device may not cause harmful interference.

2. This device must accept any interference received, including interference that
may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for


compliance could void the user's authority to operate the equipment.

Conventions

ZTE documents employ the following typographical conventions.

Typeface Meaning

Italics References to other Manuals and documents.

“Quotes” Links on screens.

Menus, menu options, function names, input fields, radio button names,
Bold
check boxes, drop-down lists, dialog box names, window names.

CAPS Keys on the keyboard and buttons on screens and company name.

Note: Provides additional information about a certain topic.

Checkpoint: Indicates that a particular step needs to be checked before


proceeding further.

III
Typeface Meaning

Tip: Indicates a suggestion or hint to make things easier or more


productive for the reader.

IV
Declaration of RoHS
Compliance
———————————————————————————————————————————

To minimize environmental impacts and take more responsibilities to the earth we


live on, this document shall serve as a formal declaration that ZXWN MSCS
manufactured by ZTE CORPORATION is in compliance with the Directive
2002/95/EC of the European Parliament - RoHS (Restriction of Hazardous
Substances) with respect to the following substances:
z Lead (Pb)
z Mercury (Hg)
z Cadmium (Cd)
z Hexavalent Chromium (Cr (VI))
z PolyBrominated Biphenyls (PBBs)
z PolyBrominated Diphenyl Ethers (PBDEs)

ZXWN MSCS manufactured by ZTE CORPORATION meets the requirements of


EU 2002/95/EC; however, some assemblies are customized to client specifications.
Addition of specialized, customer-specified materials or processes which do not
meet the requirements of EU 2002/95/EC may negate RoHS compliance of the
assembly. To guarantee compliance of the assembly, the need for compliant
product must be communicated to ZTE CORPORATION in written form.
This declaration is issued based on our current level of knowledge. Since
conditions of use are outside our control, ZTE CORPORATION makes no
warranties, express or implied, and assumes no liability in connection with the use
of this information.

I
II
Chapter1
Timers Related with SCCP
Module
———————————————————————————————————————————

1.1 Timer 40191


Macro Name of Timer

TIMER_CONNECTKEEPALIVE

Value Range

30~3600s

Default Duration

36s

Timer Description

This timer is the keep-alive timer for the SCCP connection-oriented data areas and
services. Every time when this timer expires, the SCCP module initiates a
keep-alive packet to services. A keep-alive period consists of several durations of
this timer.

1.2 Timer 40192


Macro Name of Timer

TIMER_CGTDECAY

Value Range

1~10s

Default Duration

4s

1-1

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Timer Description

This timer is the long timer of the SCCP congestion level. When the short timer is
started, the long timer is started at the same time. If the long timer expires, the
congestion level decreases by one.

1.3 Timer 40193


Macro Name of Timer

TIMER_CGTADD

Value Range

100~1000ms

Default Duration

400ms

Timer Description

This timer is the short timer of the SCCP congestion level. When the SCCP module
receives the first MTP_Status congestion indication, it starts this timer, and the
congestion level increases by one. Before this timer expires, the SCCP module
ignores other MTP_Status congestion indications.

1.4 Timer 40194


Macro Name of Timer

LUDTTy

Value Range

10~20s

Default Duration

15s

Timer Description

This timer is a message reassembly timer. When the SCCP module receives the
first fragment, it starts this timer. If the message reassembly has been completed
before this timer expires, the SCCP module stops this timer. Otherwise, the
message reassembly aborts.
1-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter1Timers Related with SCCP Module

1.5 Timer 40195


Macro Name of Timer

XUDTTy

Value Range

10~0s

Default Duration

15s

Timer Description

This timer is the message recomposing timer. When the SCCP module receives the
first fragment, it starts this timer. If the message recomposing has been completed
before this timer expires, the SCCP module stops this timer. Otherwise, the
message recomposing is abandoned.

1.6 Timer 40196


Macro Name of Timer

TIME_SOR

Value Range

30~120s

Default Duration

60s
If the subsystem has received a SOG message before this timer expires, it stops
this timer, and starts timer 2008. Otherwise, the subsystem negotiation procedure is
terminated.

Timer Description

This timer is the timer for subsystem status coordination. When the subsystem exits
the service, it starts this timer, and waits for a response from the standby subsystem.
If the subsystem has received a SOG message before this timer expires, it stops
this timer, and starts timer TIME_IGNORE_SST. Otherwise, the subsystem
coordination procedure is terminated.

1-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1.7 Timer 40197


Macro Name of Timer

TIME_IGNORE_SST

Value Range

60~180s

Default Duration

120s

Timer Description

This timer is a test ignoring timer. After receiving a SOG message, the SCCP
module starts this timer. Before this timer expires, all the received subsystem test
messages are ignored.

1.8 Timer 40198


Macro Name of Timer

TIMER_FREEZE

Value Range

10~45s

Default Duration

30s

Timer Description

This timer is a reference freezing timer. When a connection is released, the


reference of the connection is frozen. Only after the freezing ends, the reference
can be reallocated and used.

1.9 Timer 40199


Macro Name of Timer

TIMER_GUARD

Value Range
1-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter1Timers Related with SCCP Module

1~1500s

Default Duration

3s

Timer Description

This timer is a restart protection timer. This timer specifies the protection duration
that you need to wait for when the system is restarted. In the worst case, all
connections are released before the system is restarted. Before this timer expires,
the SCCP module sends a response if it has received a connection release
message, and discards other messages if it has received them. After this timer
expires, the SCCP module sends a restart-procedure-finished indication.

1.10 Timer 40200


Macro Name of Timer

TIMER_INTERNAL

Value Range

60~120s

Default Duration

60s

Timer Description

After the SCCP module sends the first release request, it starts this timer. If the
SCCP module has received a response before this timer expires, it stops the timer.
Otherwise, the SCCP module stops this timer, and releases the connection.

1.11 Timer 40201


Macro Name of Timer

TIMER_RESET

Value Range

10~20s

Default Duration

1-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

15s

Timer Description

For the connection-oriented services, this timer specifies the duration of waiting for
a reset acknowledgement message during the reset. If the SCCP module has
received a reset acknowledgement or reset request message before this timer
expires, it stops this timer. Otherwise, it starts the connection release procedure.

1.12 Timer 40202


Macro Name of Timer

TIMER_RELEASE

Value Range

10~20s

Default Duration

15s

Timer Description

For the connection-oriented services, this timer specifies the duration of waiting for
connection release. If the SCCP module has received a response before this timer
expires, it stops the timer, and releases the connection. Otherwise, it restarts the
timer.

1.13 Timer 40203


Macro Name of Timer

TIMER_IT_SEND

Value Range

30~600s

Default Duration

60s

Timer Description

1-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter1Timers Related with SCCP Module

This timer specifies the interval for sending messages on the connection section. If
this timer expires, the SCCP module sends an IT message, and restarts the timer.

1.14 Timer 40204


Macro Name of Timer

TIMER_IT_RECEIVE

Value Range

180~1320s

Default Duration

720s

Timer Description

This timer specifies the interval between receiving messages on the connection
section. Every time when receiving a message on the connection section, the SCCP
module restarts this timer. If this timer expires, the SCCP module releases the
connection.

1.15 Timer 40205


Macro Name of Timer

TIMER_CONNECT

Value Range

30~360s

Default Duration

90s

Timer Description

For the connection-oriented services, after the SCCP module sends a connection
request, it starts this timer, and waits for a response. If this timer expires, the
connection establishment fails.

1-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


1-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter2
Timers Related with MTP3
Module
———————————————————————————————————————————

2.1 Timer 40405


Macro Name of Timer

T_MTP3_SYNCLINK_LEN

Value Range

In view of performance, the value should not be less than 10s.

Default Duration

300s

Timer Description
This timer specifies the duration of recovering inconsistence of the status of a
multiple-module link.

2-1

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


2-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter3
Timers Related with MTP2
Module
———————————————————————————————————————————

3.1 Timer 40595


Macro Name of Timer

MTP2_T9

Value Range

100~3000ms

Default Duration

300ms

Timer Description
This timer specifies the duration of detecting the inactivity of an MTP2 link.

3.2 Timer 40596


Macro Name of Timer

MTP2_T4E_2M

Value Range

400~600ms

Default Duration

500ms

Timer Description
3-1

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

This timer specifies the duration for emergent verification of an MTP2 link.

3.3 Timer 40597


Macro Name of Timer

MTP2_T4N_2M

Value Range

3~70s

Default Duration

30s

Timer Description

This timer specifies the duration for normal verification of an MTP2 link.

3.4 Timer 40598


Macro Name of Timer

MTP2_T3_2M

Value Range

1000~2000ms

Default Duration

1500ms

Timer Description

This timer specifies the duration from the time when an MTP2 link sends an SIN (E)
message until the MTP2 link receives another SIN (E) message.

3.5 Timer 40599


Macro Name of Timer

MTP2_T2_2M

Value Range

3-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 3 Timers Related with MTP2 Module

5~150s

Default Duration

130s

Timer Description

This timer specifies the duration from the time when an MTP2 link sends an SIO
message until the MTP2 link receives another SIO/SIN (E) message.

3.6 Timer 40600


Macro Name of Timer

MTP2_T1_2M

Value Range

25~350s

Default Duration

150s

Timer Description

This timer specifies the duration from the time when an MTP2 link is located and
prepared until the link enters the service status.

3.7 Timer 40601


Macro Name of Timer

MTP2_T4E_64K

Value Range

400~600ms

Default Duration

500ms

Timer Description

This timer specifies the duration for emergent verification of an MTP2 link.

3-3

SJ-20100914141201-030|2010-11-24 (R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

3.8 Timer 40602


Macro Name of Timer

MTP2_T4N_64K

Value Range

7500~9500ms

Default Duration

8200ms

Timer Description

This timer specifies the duration for normal verification of an MTP2 link.

3.9 Timer 40603


Macro Name of Timer

MTP2_T3_64K

Value Range

1000~2000ms

Default Duration

1500ms

Timer Description

This timer specifies the duration from the time when an MTP2 link sends an SIN (E)
message until the MTP2 link receives another SIN (E) message.

3.10 Timer 40604


Macro Name of Timer

MTP2_T2_64K

Value Range

5~150s

Default Duration
3-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 3 Timers Related with MTP2 Module

25s

Timer Description

This timer specifies the duration from the time when an MTP2 link sends an SIO
message until the MTP2 link receives another SIO/SIN (E) message.

3.11 Timer 40605


Macro Name of Timer

MTP2_T1_64K

Value Range

40~50s

Default Duration

45s

Timer Description

This timer specifies the duration from the time when an MTP2 link is located and
prepared until the link enters the service status.

3-5

SJ-20100914141201-030|2010-11-24 (R1.0) ZTE Proprietary and Confidential


3-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter4
Timers Related with SIGTRANT
Module
———————————————————————————————————————————

4.1 Timer 49205


Macro Name of Timer

T_STC_ASSOC_CGSTCLR_DELAY

Value Range

10s~1800s

Default Duration

360s

Timer Description
This timer is valid only when the packet loss optimization function of the control
plane is enabled. When a congested association becomes uncongested, the
SIGTRAN module starts this timer. After this timer expires, the congestion is
completely relived. (STC)

4.2 Timer 49603


Macro Name of Timer

CLDTTy

Value Range

10s~20s

Default Duration

15s
4-1
ZXWN MSCS Timer Reference Ⅰ

Timer Description

This timer is the slicing timer. If this timer expires, the SIGTRAN module packages
XUDT messages. (SUA)

4.3 Timer 49604


Macro Name of Timer

TIME_SUASOR

Value Range

60s~120s

Default Duration

60s

Timer Description

This timer is the service interruption request timer. After sending an N_CoordReq
message, the SIGTRAN module starts this timer. (SUA)

4.4 Timer 49605


Macro Name of Timer

TIME_SUAIGNORE_SST

Value Range

60s~180s

Default Duration

120s

Timer Description

This timer is the subsystem test timer. (SUA)

4.5 Timer 49705


Macro Name of Timer

T_M3UA_ASP_CGSTCLR_DELAY
4-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 4 Timers Related with SIGTRANT Module

Value Range

10s~1800s

Default Duration

360s

Timer Description

This timer is valid only when the packet loss optimization function of the control
plane is enabled. When a congested association becomes uncongested, the
SIGTRAN module starts this timer. After this timer expires, the congestion is
completely relived. (M3UA)

4.6 Timer 49804


Macro Name of Timer

T_UAM_ASPENDING_LEN

Value Range

100ms~60000ms

Default Duration

5000ms

Timer Description

When the AS is in PENDING status, this timer is started. After this timer expires, the
status of the AS changes. This timer is a public timer for UA protocols. (UAM)

4.7 Timer 49805


Macro Name of Timer

T_UAM_ASPACK_LEN

Value Range

100ms~60000ms

Default Duration

2000ms

4-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Timer Description

This timer is a public timer for ASP status changing in the SGITRAN protocol stack.
After sending an ASP UP, ASP DOWN, ASP ACTIVE, or ASP INACTIVE message,
the SGITRAN module starts this timer, and waits for an acknowledgement message.
(UAM)

4.8 Timer 49999


Macro Name of Timer

M2PA_TIMER7

Value Range

2s~10s

Default Duration

2s

Timer Description

This timer is the answer detection timer. If this timer expires, the link exits the
service. (M2PA)

4.9 Timer 50000


Macro Name of Timer

M2PA_TIMER6

Value Range

3s~6s

Default Duration

5s

Timer Description

This timer is the congestion duration timer. If this timer expires, the link exits the
service. (M2PA)

4-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 4 Timers Related with SIGTRANT Module

4.10 Timer 50001


Macro Name of Timer

M2PA_TIMER4_EMERG

Value Range

500ms~1000ms

Default Duration

500ms

Timer Description

This timer is used for the verification phase during the initial locating of a link. If this
timer expires, the link enters the verification completion phase. (M2PA)(Short
period)

4.11 Timer 50002


Macro Name of Timer

M2PA_TIMER4_NORMAL

Value Range

7s~10s

Default Duration

8s

Timer Description

This timer is used for the verification phase during the initial locating of a link. If this
timer expires, the link enters the verification completion phase. (M2PA)(Long
period)

4.12 Timer 50003


Macro Name of Timer

M2PA_TIMER3

Value Range
4-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

6s~7s

Default Duration

6s

Timer Description

This timer is used for the located phase during the initial locating of a link. If this
timer expires, the link exits the service. (M2PA)

4.13 Timer 50004


Macro Name of Timer

M2PA_TIMER2

Value Range

10s~15s

Default Duration

10s

Timer Description

This timer is used for the non-located phase during the initial locating of a link. If this
timer expires, the link exits the service. (M2PA)

4.14 Timer 50005


Macro Name of Timer

M2PA_TIMER1

Value Range

40s~50s

Default Duration

45s

Timer Description

This timer is used for the verification completion phase during the initial locating of a
link. If this timer expires, the link exits the service. (M2PA)
4-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter5
Timers Related with ALCAP
Module
———————————————————————————————————————————

5.1 Timer 89999


Macro Name of Timer

ALCAP_TIMER_HEARTBEAT

Default Duration

10s

Timer Description

This timer is the ALCAP user keep-alive timer.

5.2 Timer 90000


Macro Name of Timer

ALCAP_TIMER_UNIPROTECT

Default Duration

25s

Timer Description

This timer is the intermittent-disconnection protection timer for UNI offices.

5.3 Timer 90001


Macro Name of Timer

5-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

ALCAP_TIMER_AAL2PATH

Default Duration

25s

Timer Description

This timer is the PATH delay reset timer (intermittent-disconnection protection).

5.4 Timer 90002


Macro Name of Timer

ALCAP_TIMER_LINKBREAK

Default Duration

5s

Timer Description

This timer is the intermittent-disconnection protection timer for NNI offices.

5.5 Timer 90003


Macro Name of Timer

ALCAP_TIMER_MOD

Value Range

5~30 s

Default Duration

20s

Timer Description

The ALCAP module sends an MOD message to modify an AAL2 connection. After
receiving an MOA or MOR message, the ALCAP module stops this timer.

5.6 Timer 90004


Macro Name of Timer

5-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 5 Timers Related with ALCAP Module

ALCAP_TIMER_UBL

Value Range

2~60s

Default Duration

20s

Timer Description

The ALCAP module sends a UBL message to unblock a bearer channel. After
receiving a UBC message, the ALCAP module stops this timer.

5.7 Timer 90005


Macro Name of Timer

ALCAP_TIMER_BLO

Value Range

2~60 s

Default Duration

20s

Timer Description

The ALCAP module sends a BLO message to block a bearer channel. After
receiving a BLC message, the ALCAP module stops this timer.

5.8 Timer 90006


Macro Name of Timer

ALCAP_TIMER_RES

Value Range

2~60 s

Default Duration

20s

5-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Timer Description

The ALCAP module sends a RES message to reset a bearer channel. After
receiving a RSC message, the ALCAP module stops this timer.

5.9 Timer 90007


Macro Name of Timer

ALCAP_TIMER_REL

Value Range

2~60 s

Default Duration

20s

Timer Description

The ALCAP module sends a REL message to release an AAL2 connection. After
receiving a RLC message, the ALCAP module stops this timer.

5.10 Timer 90008


Macro Name of Timer

ALCAP_TIMER_ERQ

Value Range

5~30 s

Default Duration

20s

Timer Description

The ALCAP module sends an ERQ message to establish an AAL2 connection. After
receiving an ECF message, the ALCAP module stops this timer.

5-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter6
Timers Related with GCM
Module
———————————————————————————————————————————

6.1 Timer 205101


Macro Name of Timer

gcm_T_WaitH2 48Rsp

Timer Name

GCM Wait H248Rsp

Value Range

0~65535ms

Default Duration

8000ms

Adjustment Step Length

1ms

Flow Description

GCM H248S

EV_MC_RESERVE_BEARER_CHAR_REQ

EV_MC_RESERVE_BEARER_CHAR_RSP/
EV_MC_RESERVE_BEARER_CHAR_NACK

6-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. When the bearer is established, after the GCM module sends an


EV_MC_RESERVE_BEARER_CHAR_REQ message to the H248S
module, it starts this timer.
2. After receiving an EV_MC_CONFIRM_BEARER_CHAR_RSP or
EV_MC_CONFIRM_BEARER_CHAR_NACK message from the H248S
module, the GCM module stops this timer.
3. During the procedures including not releasing terminals and
bearer-related operations, after the GCM module sends a message to
the H248S module, this timer is used. The procedure described above is
just one instance.

6.2 Timer 205102


Macro Name of Timer

gcm_T_WaitBearRel

Timer Name

GCM Wait BearRel

Value Range

0~65535ms

Default Duration

8000ms

Adjustment Step Length

1ms

Flow Description
M_Gcm_Timer_Wait
BearRel

6-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

1. When the bearer is released, the GCM module starts this timer, and
then sends an EV_MC_RELEASE_BEARER_REQ message to the
H248S module. If the BCBM module exists, the GCM module tells the
BCBM module to release the bearer.
2. After receiving EV_MC_RELEASE_BEARER_RSP and
EV_BC_BcReleaseRsp messages (if the BCBM module exists), the
GCM module stops this timer.
3. If the terminal is released, the above
EV_MC_RELEASE_BEARER_REQ/EV_MC_RELEASE_BEARER_RS
P messages are replaced with
EV_MC_RELEASE_TERM_REQ/EV_MC_RELEASE_TERM_RSP
messages.

6.3 Timer 205103


Macro Name of Timer

gcm_T_CodecNego

Timer Name

GCM Wait CodecNego

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

6-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

GCM SIG

EV_L4L3_APMINFO_IND
(Codec negotiation in the call)
M_Gcm_Timer_C
odecNego

EV_L3L4_APMINFO_IND
(Modifying the selected codec information or
medication failure)

1. When the GCM module performs codec negotiation, it starts this timer,
and waits for a codec negotiation response message from the peer-end
office.
2. After receiving the codec negotiation response message from the
peer-end office, the GCM module stops this timer.

6.4 Timer 205104


Macro Name of Timer

gcm_T_CodecModify

Timer Name

GCM Wait CodecModify

Value Range
0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

6-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

GCM SIG

EV_L4L3_APMINFO_IND
(Modifying the selected codec information)

EV_L3L4_APMINFO_IND
(Success or failure in modifying the codec
information)

1. When the GCM module performs codec modification, it starts this timer,
and waits for a codec modification response message from the peer-end
office.
2. After receiving the codec modification response message from the
peer-end office, the GCM module stops this timer.

6.5 Timer 205106


Macro Name of Timer

gcm_T_iWaitCotMsg(T8)

Timer Name

GCM CPCI Wait Cot Message

Description
This timer is not used at present.

6.6 Timer 205107


Macro Name of Timer

gcm_T_WaitCallerInfo

Timer Name

GCM Wait CallerInfo

Value Range

0~65535ms

Default Duration
6-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

12000ms

Adjustment Step Length

1ms

Flow Description

GCM SIG

EV_L4L3_INFOREQUEST_IN
D
INR

INF

EV_L3L4_INFORMATION_IND

1. When this procedure needs some information (such as the calling


number, the type of the calling subscriber, and the original called
number), the GCM module sends an INR (information request) message
to the peer-end office, and then starts this timer.
2. After receiving a response (INF) message, the GCM module stops this
timer.

6.7 Timer 205108


Macro Name of Timer

gcm_T_WaitSubDn

Timer Name

GCM Wait SubDn

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms
6-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

Flow Description

SIG GCM

IAM
EV_L3L4_SETUP_IND

SAM
EV_L3L4_INFORMATION_IND

1. During an incoming call, after the GCM module receives an


EV_L3L4_SETUP_IND message, it needs to start this timer, and waits
for the subsequent digits in the following cases, because the IAM (initial
address message) may not contain the complete address information.
z When the number analysis is performed in the tandem office, the called
number does not reach the maximum number length nor has an ST flag,
or no timeout occurs when waiting for the subsequent digits.
z The ST flag is needed for outgoing. The called number does not reach
the maximum number length nor has an ST flag, or no timeout occurs
when waiting for the subsequent digits.
z A trunk number does not change successfully due to insufficient digits,
so it is required to wait for the subsequent digits.
z Through the number pre-analysis, the number containing exists, and it is
required to wait for the SAM message.
z When the called number is analyzed, the number analysis does not end,
and the number containing exists.
z After the number analysis, the called number is not a vacant number,
and does not reach the minimum number length. The called number has
no ST flag. No timeout occurs when waiting for the subsequent digits.
2. After receiving an SAM message, the GCM module stops this timer.
3. This timer may be restarted for multiple times.

6.8 Timer 205109


Macro Name of Timer

gcm_T_WaitNumComplete

Timer Name

GCM Wait NumComplete

Value Range

6-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

M_Gcm_Timer_Wai
tNumComplete

1. An incoming call is analyzed to an intelligent service through number


analysis. When the GCM module waits for the called number, and if the
called number does not reach the maximum number length configured
in the number analysis configuration, the GCM module starts this timer.
2. After receiving an SAM message, the GCM module stops this timer, and
performs number analysis again.
3. This procedure may be repeated for multiple times.

6.9 Timer 205110


Macro Name of Timer

gcm_T_WaitRbt

Timer Name

GCM Wait Rbt

Value Range

0~65535ms

Default Duration
6-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

5000ms

Adjustment Step Length

1ms

Flow Description

M_Gcm_Timer_WaitN
umComplete

1. After sending an EV_L4L3_ALERTING_IND or


EV_L4L3_PROGRESS_INDmessage to the CAS module, the GCM
module starts this timer, and waits for an EV_L3L4_RBT_ACK message.
2. After receiving the EV_L3L4_RBT_ACK message, the GCM module
stops this timer.

6.10 Timer 205111


Macro Name of Timer

gcm_T_WaitTpInfo

Timer Name

GCM Wait TpInfo

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

6-9

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Flow Description
M_Gcm_Timer_WaitN
umComplete

1. After a call is analyzed to an outgoing call through the number analysis,


the GCM module sends a message to the DB to query the outgoing
trunk circuit. Then the GCM module starts this timer, and waits for a
response message.
2. After receiving the response message, the GCM module stops this
timer.

6.11 Timer 205112


Macro Name of Timer

gcm_T_WaitAlert

Timer Name
GCM Wait Alert

Value Range

0~65535ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

6-10

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

GCM(OP) GCM(TP) ISUP

EV_HC_Setup
EV_L4L3_SETUP_IND

IAM

ACM
EV_L3L4_ALERTING_
IND
EV_HC_Alerting

1. After sending an EV_HC_Setup message, the GCM (OP) module starts


this timer at the OP side, and waits for an EV_HC_Alerting response
message.
2. After receiving the EV_HC_Setup message and sends it to the peer-end
office, the GCM (TP) module starts this timer at the TP side, and waits
for an ACM response message from the peer-end office.
3. After the peer-end office returns an ACM message, the GCM (TP)
module stops this timer at the TP side, and sends an EV_HC_Alerting
message to the GCM (OP) module.
4. After receiving the EV_HC_Alerting message, the GCM (OP) module
stops this timer at the OP side.
5. In case of directly returning the response, the processing of this timer is
the same with that of returning the ACM message. The ACM message is
replaced with the CON message, the EV_L3L4_ALERTING_IND
message is replaced with the EV_L3L4_ANSWER_IND message, and
the EV_HC_Alerting message is replaced with the EV_HC_StartConv
message.

6.12 Timer 205113


Macro Name of Timer

gcm_T_WaitAnswerMob

Timer Name

GCM Wait AnswerMob

Value Range

0~180000ms

6-11

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Default Duration

45000ms

Adjustment Step Length

1ms

Flow Description

M_Gcm_TimerLen
M_Gcm_TimerLen_

_WaitAnswerMob
WaitAnswerMob

1. After receiving an EV_L3L4_ALERTING_IND message from the SIG


module, the GCM (TP) module starts this timer at the TP side. After
receiving an EV_HC_Alerting message from the TP side, the GCM (OP)
module starts this timer at the OP side.
2. After receiving an EV_L3L4_ANSWER_IND message from the SIG
module, the GCM (TP) module stops this timer at the TP side. After
receiving an EV_HC_StartConv message from the TP side, the GCM
(OP) module stops this timer at the OP side.
3. In case of tone play, the GCM (OP) module constructs an
EV_L3L4_ALERTING_IND message, and sends it. Then it starts this
timer.
4. This timer is used when the number analysis result is the one of the
following items.
z CAT_MSC_LOCAL_OUTGOING_WCDMA
z CAT_MSC_REGION_OUTGOING_WCDMA
z CAT_MSC_REGION_OUTGOING_CDMA2000
z CAT_MSC_INTERNATIONAL_OUTGOING_WCDMA
z CAT_MSC_INTERNATIONAL_OUTGOING_CDMA2000

6.13 Timer 205114


Macro Name of Timer

gcm_T_WaitAnswerLoc
6-12

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

Timer Name

GCM Wait AnswerLoc

Value Range

0~180000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

1. For the detailed flow, refer to 6.12 Timer 205113.


2. This timer is used during a local call.

6.14 Timer 205115


Macro Name of Timer

gcm_T_WaitAnswerTol

Timer Name

GCM Wait AnswerTol

Value Range

0~180000ms

Default Duration

90000ms

Adjustment Step Length

1ms

Flow Description

1. For the detailed flow, refer to 6.12 Timer 205113.


2. This timer is used during a national toll call when the number analysis
result is the one of the following items.
z CAT_REGION_IN_MANU
z CAT_REGION_IN_AUTO
z CAT_REGION_OUT_MANU
6-13

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

z CAT_REGION_OUT_AUTO
z CAT_IP
z CAT_DDC_NAT_INCOMING
z CAT_DDC_NAT_OUTGOING

6.15 Timer 205116


Macro Name of Timer

gcm_T_WaitAnswerInt

Timer Name

GCM Wait AnswerInt

Value Range

0~180000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

1. For the detailed flow, refer to 6.12 Timer 205113.


2. This timer is used during an international toll call when the number
analysis result is the one of the following items.
z CAT_INTERNATIONAL_MANU
z CAT_INTERNATIONAL_AUTO

6.16 Timer 205117


Macro Name of Timer

gcm_T_WaitSetup

Timer Name

GCM Wait Setup

Value Range

0~65535ms

Default Duration
6-14

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

30000ms

Adjustment Step Length

1ms

Flow Description

OP GCM

EV_L3L4_TPCALL_IND
EV_HC_TpInfo

M_Gcm_Timer_WaitAl
ert
EV_HC_Setup

1. After bringing the TP-side-related information to the OP side, the GCM


module at the outgoing side starts this timer, and waits for an
EV_HC_Setup message.
2. After receiving the EV_HC_Setup message from the OP side, the GCM
module stops this timer.

6.17 Timer 205118


Macro Name of Timer

gcm_T_WaitAliveTestAck

Timer Name

GCM Wait AliveTestAck

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

6-15

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Flow Description

1. When a call enters the stable status, the GCM module timely shakes
hands with the peer-end modules. After sending a handshaking request
message to each peer-end module, the GCM module starts this timer,
and waits for the handshaking response messages from the peer
modules.
2. After receiving the handshaking response messages from all the peer
modules, the GCM module stops this timer.

6.18 Timer 205119


Macro Name of Timer

gcm_T_WaitResumeT6

Timer Name

GCM Wait Resume_T6

Value Range

0~180000ms

Default Duration

90000ms

Adjustment Step Length

1ms

Flow Description
6-16

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

1. When a call enters the stable status, the network of the peer-end office
suspends this call. After receiving an EV_L3L4_SUSPEND_IND
message, the GCM module starts this timer.
2. After receiving an EV_L3L4_RESUME_IND message, the GCM module
stops this timer.

6.19 Timer 205120


Macro Name of Timer

gcm_T_WaitRelSigRsp

Timer Name

GCM Wait RelSigRsp

Value Range

0~65535ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

6-17

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

M_Gcm_Timer_Wait
RelSigRsp

1. If the bearer is not in the IDLE status, when the GCM module initiates a
bearer release procedure, the SIG module is required to return a
response message after releasing the bearer. After sending an
EV_L4L3_RELEASE_IND message to the SIG module, the GCM
module starts this timer.
2. After receiving an EV_L4L3_RELEASE_IND message from the SIG
module, the GCM module stops this timer.

6.20 Timer 205123


Macro Name of Timer

gcm_T_CallPeriodTraffic

Timer Name

GCM Wait CallPeriodTraffic

Value Range

60000~300000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

6-18

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

M_Gcm_Time
r_CallPeriodT
raffic

1. After receiving an EV_HC_StartConv message, the GCM module at the


OP side starts this timer.
2. After this timer expires, the GCM module reports the traffic statistics,
and sends an mohTrafficDataInEvent message.
3. Then the GCM module restarts this timer. After this timer expires, the
GCM module reports the traffic statistics again.

6.21 Timer 205125


Macro Name of Timer

gcm_T_R2WaitAddr

Timer Name

GCM Wait R2 Address

Value Range

0~180000ms

Default Duration

45000ms

Adjustment Step Length

1ms

Flow Description

6-19

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

M_Gcm_Timer_R2
WaitAddr

1. During an incoming call over CAS, after the bearer is successfully


established, the GCM module tells the SIG module to start receiving
numbers, and starts this timer.
2. After receiving an EV_L3L4_INFORMATION_IND message carrying the
number information, the GCM module stops this timer.
3. In another case, this timer will be started. After the number analysis, if it
is required to make the number reach the maximum number length, the
GCM module actively sends an EV_L4L3_INFOREQUEST_IND
message, and starts this timer. After receiving an
EV_L3L4_INFORMATION_IND message, the GCM module stops this
timer.

6.22 Timer 205126


Macro Name of Timer

gcm_T_WaitAuthRslt

Timer Name

GCM Wait AuthRslt

Value Range

1000~120000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description
6-20

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

M_Gcm_Timer_Wai
tAuthRslt

1. During an incoming call, after the number analysis, if it is required to


start the blacklist/whitelist authentication function, the GCM module
sends an authentication request message to the authentication module.
Then the GCM module starts this timer, and waits for a response
message.
2. During an outgoing call, when the GCM module sends a SETUP
message to peer-end office, if it is required to start the blacklist/whitelist
authentication function, the GCM module sends an authentication
request message to the authentication module. Then the GCM module
starts this timer, and waits for a response message.
3. After receiving the DM_AUTH response message, the GCM module
stops this timer.

6.23 Timer 205127


Macro Name of Timer

gcm_T_WaitAcc

Timer Name

GCM Wait Acc

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

6-21

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Flow Description

M_Gcm_TimerLen_
WaitAcc

1. After receiving a REL message carrying the ACC parameter from the
backward office, the GCM module starts this timer for this adjacent
office.
2. If this timer expires, the GCM module gets the congestion level from the
DB. After the congestion level decreases by one level, the GCM module
restarts this timer.

6.24 Timer 205128


Macro Name of Timer

gcm_T_WaitResumeT2

Timer Name

GCM Wait Resume_T2

Value Range

0~300000ms

Default Duration

180000ms

Adjustment Step Length

1ms

Flow Description

6-22

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

M_Gcm_Timer_Wait
Resume T6

1. When a call enters the stable status, the subscriber of the peer-end
office suspends this call. After receiving an EV_L3L4_SUSPEND_IND
message, the GCM module starts this timer.
2. After receiving an EV_L3L4_RESUME_IND message, the GCM module
stops this timer.

6.25 Timer 205129


Macro Name of Timer

gcm_T_60sShortBusyTone

Timer Name

GCM Wait 60sBusyTone

Value Range

0~3600000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

6-23

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

60sShortBusyTo
M_Gcm_Timer_
ne

1. When a call enters the stable status, the GCM module receives an
EV_HC_Release message. If the fast busy tone is supported, and the
switching of playing 60s-fast-busy-tone is opened, the GCM module
starts playing the tone, and starts this timer.
2. After this timer expires, the GCM module stops playing the tone.

6.26 Timer 205130


Macro Name of Timer

gcm_T_oWaitCotToneInd(T24)

Timer Name

GCM Wait Check tone result T24

Value Range

0~10000ms

Default Duration

1500ms

Adjustment Step Length

1ms

Flow Description

6-24

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

M_Gcm_Timer_oWait
CotToneIndT24

1. The GCM module at the TP side judges that it needs to initiate the
continuity on this section, so it sends a continuity tone play directive to
the H248 module, and sends an EV_L4L3_SETUP_IND message. Then
the GCM module starts this timer.
2. After receiving the continuity result from the H248 module, the GCM
module stops this timer.
3. In case of the re-continuity, or the continuity command sent from the
OMC, the GCM module sends an EV_L4L3_COTREQUEST_IND
message to the peer-end office, and other processing procedures are
the same.

6.27 Timer 205131


Macro Name of Timer

gcm_T_oCallWaitReCheck(T25)

Timer Name

GCM Call Wait to Re-Check T25

Value Range

0~10000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

6-25

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

M_Gcm_Timer_oC
allWaitReCheckT2
5

1. During a call, after the continuity at the outgoing side fails, the GCM
module receives an message. Then the GCM module starts this timer.
After this timer expires, the GCM module will initiate a re-continuity
procedure.
2. If this timer expires, the GCM module sends a re-continuity
(EV_L4L3_COTREQUEST_IND) message to the peer-end office, and
sends a continuity-tone check directive.
3. If the GCM module has not received an EV_L3L4_RELEASE_IND
message before this timer expires, it stops this timer, and does not
initiate a re-continuity procedure again.

6.28 Timer 205132


Macro Name of Timer

gcm_T_oWaitReCheck(T26)

Timer Name

GCM CRO Wait to trig ReCot T26

Value Range

0~180000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

6-26

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

WaitReCheckT26
M_Gcm_Timer_o

1. During the re-continuity procedure at the outgoing side, after the GCM
module receives the continuity failure result, it tells the backward office
to stop playing the continuity tone. If the GCM module is required to
initiate a re-continuity procedure again, it starts this timer.
2. If this timer expires, the GCM module initiates a re-continuity procedure,
and sends an EV_L4L3_COTREQUEST_IND message to the backward
office. Then the GCM module plays the continuity tone.
3. If the GCM module has received an EV_L3L4_RELEASE_IND message
before this timer expires, it stops this timer.

6.29 Timer 205133


Macro Name of Timer

gcm_T_iWaitCCRMsg(T27)

Timer Name

GCM CRI Wait CCR T27

Value Range

0~240000ms

Default Duration

240000ms

Adjustment Step Length

1ms

Flow Description

6-27

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

M_Gcm_Timer_iW
aitCCRMsgT27

1. During an incoming call, after the continuity on this section fails, a


re-continuity is initiated. The GCM module sends an EV_Gcm_StartCci
message to itself, and triggers this timer.
2. After receiving a re-continuity (EV_L3L4_COTREQUEST_IND(CCR)
message from the forward office, the GCM module stops this timer.
3. The GCM module loops the continuity tone back. Then it starts this timer,
and waits for the continuity result from the forward office.
4. If the GCM module receives a continuity result
(EV_L3L4_COTRESULT_IND) message or an
EV_L3L4_RELEASE_IND message, it stops this timer.

6.30 Timer 205134


Macro Name of Timer

SIG_EarlyACM_Timer

Timer Name

SIG_EarlyACM_Timer

Value Range

1000~20000ms

Default Duration

6000ms

Adjustment Step Length

1ms

Flow Description

6-28

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

M_Gcm_Timer_WaitS
dEarlyAcm

1. During an incoming call, after the GCM module sends an EV_HC_Setup


message to the called party, if the GCM module does not send an ACM
message to the forward office, and the switch of supporting ACM TYPE2
being sent early is opened, the GCM module starts this timer.
2. If the GCM module has received an EV_HC_Alerting or
EV_HC_StartConv message before this timer expires, it stops this timer.
3. If this timer expires, GCM module sends an EV_L4L3_ALERTING_IND
message to the SIG module.

6.31 Timer 205135


Macro Name of Timer

gcm_T_ContToneLimit

Timer Name

GCM send tone Wait caller rel

Value Range

60000~86400000ms

Default Duration

14400000ms

Adjustment Step Length

1ms

Flow Description

6-29

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

M_Gcm_Timer_ContT
oneLimit
1. An incoming call is analyzed to the tone-play service through the
number analysis, and “continuous tone play for incoming special
numbers” is configured. After the GCM module constructs an Alerting
message, and sends it to the peer-end office, it starts this timer.
2. If this timer expires, the GCM module releases the call.
3. If the GCM module receives an EV_L3L4_RELEASE_IND message
from the calling party during the course of tone play, it releases the call,
and stops this timer.

6.32 Timer 205136


Macro Name of Timer

gcm_T_ContTonePeriod

Timer Name

GCM periodically send tone

Value Range

60000~600000ms

Default Duration

600000ms

Adjustment Step Length

1ms

Flow Description

6-30

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with GCM Module

er_ContTone
M_Gcm_Tim

Period
1. An incoming call is analyzed to the tone-play service through the
number analysis, and “continuous tone play for incoming special
numbers” is configured. After the GCM module constructs an Alerting
message, and sends it to the peer-end office, it starts timer
M_Gcm_Timer_ContTonePeriod.
2. If timer M_Gcm_Timer_ContTonePeriod expires, but timer
M_Gcm_Timer_ContToneLimit does not expire, the GCM module plays
the tone again and restarts timer M_Gcm_Timer_ContTonePeriod.

6.33 Timer 205137


Macro Name of Timer

gcmTmrWaitMRBTonePlayEnd_M

Timer Name

GCM Wait MRB Play Complete

Value Range

1000~120000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

6-31

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

T1

During a tone resource test, after the GCM module sends a tone play request, it
starts this timer. If the GCM module has received a TONECmpInd message from
the MGW before this timer expires, it continuously performs call-related processing.
If the GCM module has not received a TONECmpInd message from the MGW
before this timer expires, it releases the call.

6.34 Timer 205138


Macro Name of Timer

gcm_T_WtSendDTMFFnsh

Timer Name

GCM wait Dtmf Completed

Value Range

0~65535ms

Default Duration

250ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the interval of sending DTMF signals.


1. After sending a DTMF signal, the GCM module starts this timer.
2. After this timer expires, if the GCM module needs to send another
DTMF signal, it stops sending the previous one. Otherwise, the GCM
module performs no processing.
3. If the call is released, the GCM module stops this timer.

6-32

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter7
Timers Related with LICA
Module
———————————————————————————————————————————

7.1 Timer 205201


Macro Name of Timer

LICA_TIMER_WAIT_TPINFO

Timer Name

LICA Wait TPINFO

Value Range

0~3600000ms

Default Duration
10000ms

Adjustment Step Length

1ms

Flow Description

During an outgoing call over the X3 channel of the LICA module, after the LICA
module sends a resource request message to the DB (internal database), it starts
this timer, and waits for a response message from the DB.
The service flow is shown in the figure below.

7-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. The LICA module sends a request message for getting resources to the
DB.
2. The LICA module starts this timer.
3. If this timer expires, the LICA module releases the call over the X3
channel.

7.2 Timer 205202


Macro Name of Timer

LICA_TIMER_WAIT_ALERTING

Timer Name

LICA Wait ALERTING

Value Range

0~3600000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

During an outgoing call over the X3 channel of the LICA module, after the LICA
module sends an outgoing call message to the peer, it starts this timer, and waits
for a response message from the peer.
The service flow is shown in the figure below.

7-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with LICA Module

LICA Peer

TpInfo

Alerting

1. The LICA module receives a TPINFO message.


2. The LICA module starts this timer.
3. If this timer expires, the LICA module releases the call.

7.3 Timer 205203


Macro Name of Timer

LICA_TIMER_WAIT_ANSWER

Timer Name

LICA Wait ANSWER

Value Range

0~3600000ms

Default Duration
60000ms

Adjustment Step Length

1ms

Flow Description

After receiving an Alerting message from the peer, the LICA module starts this timer,
and waits for a Start Conversation message from the peer.
The service flow is shown in the figure below.

7-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

LICA Peer

Alerting

StartConversation

1. The LICA module receives an Alerting message from the peer.


2. The LICA module starts this timer.
3. If this timer expires, the LICA module releases the call.

7.4 Timer 205204


Macro Name of Timer

LICA_TIMER_WAIT_H248Rsp

Timer Name

LICA Wait H248Rsp

Value Range

0~3600000ms

Default Duration
10000ms

Adjustment Step Length

1ms

Flow Description

During the phase of establishing the X3 channel, after the LICA module sends an
MC_PREPARE_REQ_CDMA (terminal preparation) message, it starts this timer,
and waits for an MC_PREPARE_RSP_CDMA message from the H248 module.
The service flow is shown in the figure below.

7-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with LICA Module

1. The LICA module sends a terminal-moving request message to the


H248 module, and starts this timer.
2. After receiving the response message, the LICA module stops this timer.
3. If this timer expires, and X3 channel fails to be established, the LICA
module releases the call.

7.5 Timer 205205


Macro Name of Timer

LICA_TIMER_AliveTest_UserData

Timer Name

LICA AliveTest UserData

Value Range

0~3600000ms

Default Duration

480000ms

Adjustment Step Length

1ms

Flow Description

This timer is a survival test timer of the LICA data area. When the LICA module
successfully applies for a LICA data area, it starts this timer in this data area. Where,
the key word is the type of this data area (USER) plus the index of this data area.
After this timer expires, the LICA module starts to perform a survival test on the data
area.
The LICA module performs survival tests according to the following types of data
areas.
z User data area
7-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

z Leg data area


z Interface data area
z Basic-call data area
z Message-queue data area
This timer is the response timeout timer for waiting for the survival test operation on
a user data area.
The working flow of this timer under the condition that the detection is performed in
the user data area is as follows:
The LICA module shakes hands with the triggering module. If the handshaking is
successful, the LICA module restarts this timer. Otherwise, the LICA module
releases the whole LICA data area.
The service flow is shown in the figure below.

7.6 Timer 205206


Macro Name of Timer

LICA_TIMER_AliveTest_LegData

Timer Name
LICA AliveTest LegData

Value Range

0~3600000ms

Default Duration

540000ms

Adjustment Step Length

1ms

Flow Description

7-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with LICA Module

This timer is a survival test timer of the LICA data area. When the LICA module
successfully applies for a LICA data area, it starts this timer in this data area. Where,
the key word is the type of this data area (LEG) plus the index of this data area.
After this timer expires, the LICA module starts to perform a survival test on the data
area.
The LICA module performs survival tests according to the following types of data
areas.
z User data area
z Leg data area
z Interface data area
z Basic-call data area
z Message-queue data area
This timer is the response timeout timer for waiting for the survival test operation on
a leg data area.
The working flow of this timer under the condition that the detection is performed in
the leg data area is as follows:
The LICA module checks whether the upper-level user data area exists. If the
upper-level user data area exists, the LICA module restarts this timer. If the
handshaking fails, the LICA module releases the leg data area.

7.7 Timer 205207


Macro Name of Timer

LICA_TIMER_AliveTest_InterData

Timer Name

LICA AliveTest InterData

Value Range

0~3600000ms

Default Duration

600000ms

Adjustment Step Length

1ms

Flow Description

This timer is a survival test timer of the LICA data area. When the LICA module
successfully applies for a LICA data area, it starts this timer in this data area. Where,
the key word is the type of this data area (INTER) plus the index of this data area.

7-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

After this timer expires, the LICA module starts to perform a survival test on the data
area.
The LICA module performs survival tests according to the following types of data
areas.
z User data area
z Leg data area
z Interface data area
z Basic-call data area
z Message-queue data area
This timer is the response timeout timer for waiting for the survival test operation on
an interface data area.
The working flow of this timer under the condition that the detection is performed in
the interface data area is as follows:
The LICA module checks whether the upper-level user data area exists. If the
upper-level user data area exists, the LICA module restarts this timer. If the test fails,
the LICA module releases the interface data area, and those data areas under it
and the resources.

7.8 Timer 205208


Macro Name of Timer

LICA_TIMER_AliveTest_CallData

Timer Name

LICA AliveTest CallData

Value Range
0~3600000ms

Default Duration

660000ms

Adjustment Step Length

1ms

Flow Description

This timer is a survival test timer of the LICA data area. When the LICA module
successfully applies for a LICA data area, it starts this timer in this data area. Where,
the key word is the type of this data area (CALL) plus the index of this data area.
After this timer expires, the LICA module starts to perform a survival test on the data
area.

7-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with LICA Module

The LICA module performs survival tests according to the following types of data
areas.
z User data area
z Leg data area
z Interface data area
z Basic-call data area
z Message-queue data area
This timer is the response timeout timer for waiting for the survival test operation on
a basic-call data area.
The working flow of this timer under the condition that the detection is performed in
the basic-call data area is as follows:
The LICA module checks whether the upper-level user data area exists. If the
upper-level user data area exists, the LICA module restarts this timer. If the test fails,
the LICA module releases the basic-call data area, and those data areas under it
and the resources.

7.9 Timer 205209


Macro Name of Timer

LICA_TIMER_AliveTest_MsgQueData

Timer Name

LICA AliveTest MsgQueData

Value Range

0~3600000ms

Default Duration

720000ms

Adjustment Step Length

1ms

Flow Description

This timer is a survival test timer of the LICA data area. When the LICA module
successfully applies for a LICA data area, it starts this timer in this data area. Where,
the key word is the type of this data area (MSGQUE) plus the index of this data
area.
After this timer expires, the LICA module starts to perform a survival test on the data
area.

7-9

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

The LICA module performs survival tests according to the following types of data
areas.
z User data area
z Leg data area
z Interface data area
z Basic-call data area
z Message-queue data area
This timer is the response timeout timer for waiting for the survival test operation on
a message-queue data area.
The working flow of this timer under the condition that the detection is performed in
the message-queue data area is as follows:
The LICA module checks whether the upper-level user data area exists. If the
upper-level user data area exists, the LICA module restarts this timer. If the test fails,
the LICA module releases the message-queue data area.

7.10 Timer 205210


Macro Name of Timer

LICA_TIMER_Wait_ShakeHandAck

Timer Name

LICA Wait ShakeHandAck

Value Range

0~3600000ms

Default Duration
20000ms

Adjustment Step Length

1ms

Flow Description

To prevent data areas being suspended, the LICA module timely shakes hands with
the triggering module. After receiving a message of timer alivetest expiring, the
LICA module sends an EV_MoniShakeHandReq message to the triggering module,
and starts timer LICA Wait ShakeHandAck. After receiving the
EV_MoniShakeHandReq message, the triggering module judges whether the
module number, the index, and other information of LicaIndex are the same with the
records on the triggering module. If they are the same, the triggering module returns
an EV_MoniShakeHandAck message to the LICA module. After receiving the

7-10

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with LICA Module

acknowledgment message, the LICA module restarts timer LICA Wait


ShakeHandAck.
If the LICA module receives a message of timer LICA Wait ShakeHandAck expiring,
it releases the data area and the related resources.
The service flow is shown in the figure below.

1. The LICA module sends an EV_MoniShakeHandReq message to the


triggering module.
2. The LICA module starts timer LICA Wait ShakeHandAck.
3. If this timer expires, the LICA module releases the call.

7.11 Timer 205211


Macro Name of Timer

LICA_TIMER_WAIT_H248_DDEACK

Timer Name
LICA Wait H248 DDEACK

Value Range

0~3600000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

During the interception process, the LICA data area shakes hands with the
triggering module. After sending a handshaking request message, the LICA module
starts this timer, and waits for a response message.
7-11

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

The service flow is shown in the figure below.


TIMER

1. LICA module sends a handshaking request message to the triggering


module. Then it starts this timer, and waits for a response message from
the triggering module.
2. After receiving the response message, the LICA module stops this timer.
3. If this timer expires, the LICA module stops this timer, and stops
receiving digits.

7.12 Timer 205212


Macro Name of Timer

LICA_TIMER_WAIT_SRF_ACK

Timer Name

LICA Wait SRF ACK

Value Range

0~3600000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

It is required to play tones for the interception service, such as playing the tone for
the PIN code being intercepted, playing the failure tone, and playing the call
forwarding tone.

7-12

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with LICA Module

The service flow is shown in the figure below.

TIMER

1. The LICA module sends a tone play request message (such as


EV_PSRFPlayAnn_R message) to the SRF module, and starts this
timer.
2. After receiving the tone play acknowledgement message, the LICA
module stops this timer.
3. If this timer expires, the LIC fails to intercept the tone played to the
target subscriber.

7.13 Timer 205213


Macro Name of Timer

LICA_X3_Send_ShakeHand

Timer Name

LICA X3 Send ShakeHand

Value Range

0~3600000ms

Default Duration

600000ms

Adjustment Step Length

1ms

Flow Description

The call data area of the LICA module receives an Answer message, and starts this
timer. Then it performs handshaking and survival test operations.

7-13

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

The service flow is shown in the figure below.

LICA GCM

Answer

ShakeHandReq

1. The LICA module receives an Answer message from the peer end.
2. The LICA module starts this timer.
3. If this timer expires, the LICA module restarts this timer, and shakes
hands with the peer end to perform the survival test.

7.14 Timer 205214


Macro Name of Timer

LICA_X3_WAIT_ShakeHandACK

Timer Name

LICA X3 Wait ShakeHandACK

Value Range

0~3600000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the interception process, the LICA data area shakes hands with the
triggering module. After sending a handshaking request message, the LICA module
starts this timer, and waits for a response message.
The service flow is shown in the figure below.

7-14

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with LICA Module

LICA GCM

MoniShakeHandReq
TIMER

MoniShakeHandRsp

1. LICA module sends a handshaking request message to the triggering


module. Then it starts this timer, and waits for a response message from
the triggering module.
2. After receiving the response message, the LICA module stops this timer.
3. If this timer expires, the LICA module releases the X3 channel.

7.15 Timer 205215


Macro Name of Timer

LICA_X3_TrafficPeriod

Timer Name

LICA X3 TrafficPeriod

Value Range

0~3600000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

After receiving an Answer message from the peer end, the LICA module starts this
timer, and reports the statistics data.
The service flow is shown in the figure below.

7-15

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

MSC Peer

Answer
TIMER

Reporting the traffic


statistics data

1. The LICA module receives an Answer message from the peer end.
2. The LICA module starts this timer.
3. If this timer expires, the LICA module restarts this timer, and reports the
traffic statistics data.

7.16 Timer 205216


Macro Name of Timer

LICA_TIMER_DELAY_IAM

Timer Name

LICADelayIAM

Value Range

0~3600000ms

Default Duration

7000ms

Adjustment Step Length

1ms

Flow Description

After the first call branch is released, when the interception voice channel is
established for the second time, this timer is started. After this timer expires, the
LICA establishes a terminal, and sends an IAM message to the LIC.
The service flow is shown in the figure below.

7-16

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with LICA Module

LICA GCM LIC

EV_HC_Release

EV_MONISETUP

GCM
EV_HC_SETUP

L4L3_SETUP_ACK
IAM

1. The LICA module sends a message of releasing the X3 channel of the


first call to the GCM module.
2. When the LICA module receives the second call, and if the security
variable “Delaying sending the second IAM” is opened, the LICA module
starts this timer.
3. After this timer expires, the LICA module sends an L4L3_SETUP_IND
message to the signaling module for establishing the second X3
channel.
When the target subscriber enables the CFNA service, after the terminal is
prepared, this timer is started. Then the LICA module sends the second IAM
message to the LIC. This timer is used to prevent the failure to establish the
interception voice channel because of the line being busy (which is caused by that
the second IAM message is sent before the first voice channel is released).

7-17

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


7-18

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter8
Timers Related with LIM
Module
———————————————————————————————————————————

8.1 Timer 205301


Macro Name of Timer

limWaitMChangeOverT

Timer Name

LIM Wait MChangeOver

Value Range

0~20000ms

Default Duration
10000ms

Adjustment Step Length

1ms

Flow Description

In the standby status, the LIM module receives and message, and then judges
whether the communication between the active module and the standby one is
normal. If the communication is normal, the LIM module starts this timer, and waits
for a limChangeOverEvent message (of the active board being switched to the
standby one).
z If the LIM module has received a limChangeOverEvent message from
the active module before this timer expires, it is switched to the active
module.
z If the LIM module has not received a limChangeOverEvent message
8-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

from the active module before this timer expires, it is switched to the
active module.
The LIM module uses this system to prevent the case of two active boards.

8.2 Timer 205302


Macro Name of Timer

limCheckReqT

Timer Name

LIM CheckReq

Value Range

30000~1800000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

After the link between the LIM module and the LIG module is established, they send
check messages to each other for handshaking. This timer is started for the first
time when the link is established. After this timer expires, the LIM module sends a
CheckReq message to the LIG module, and restarts this timer.

8.3 Timer 205303


Macro Name of Timer

limWaitCheckAckT

Timer Name

LIM Wait CheckAck

Value Range

5000~30000ms

8-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter8 Timers Related with LIM Module

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

After the link between the LIM module and the LIG module is established, they send
check messages to each other for handshaking. If the LIM module actively sends a
CheckReq message to the LIG module, it starts this timer, and waits for a response
message from the LIG module. If the LIM module has not received a response
message from the LIG module before this timer expires, it reports the alarm of
failure to shake hands with the LIG module.

8.4 Timer 205304


Macro Name of Timer

limResendSynReqT

Timer Name

LIM ResendSynReq

Value Range

5000~30000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

After the link between the LIM module and the LIG module is established, the LIM
module actively sends a SyncReq message to the LIG module. Then it starts this
timer, and requests for synchronizing all tables. If the LIM module does not receive
a SynBeginReq message from the LIG module, it restarts this timer, and sends the
SyncReq message again. This procedure is circulated until the LIM module receives
a SynBeginReq message from the LIG module.

8-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

8.5 Timer 205305


Macro Name of Timer

limGetMsInfoReqT

Timer Name

LIM GetMsInfoReq

Value Range

5000~30000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After receiving a GetMsInfoReq message from the LIG module, the LIM module
sends this message to the VLR to get the subscriber data. Then it starts this timer. If
the LIM module has not received a response message from the VLR before this
timer expires, it fails to get the subscriber, and sends a failure response message to
the LIG module. In addition, after this timer is started, if the LIM module returns no
response message to the LIG module, and receives another GetMsInfoReq
message from the LIG module, it directly rejects it.

8.6 Timer 205306


Macro Name of Timer

limReInitLinkT

Timer Name

LIM ReInitLink

Value Range

5000~300000ms

Default Duration

8-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter8 Timers Related with LIM Module

10000ms

Adjustment Step Length

1ms

Flow Description

When being powered on or switched to the active module, the LIM module initializes
the interception, and attempts to establish a connection with the LIG module. If the
LIM module fails to establish the connection, it starts this timer. After this timer
expires, the LIM module initializes the interception, and attempts to establish a
connection with the LIG module again. This procedure is circulated until the LIM
module successfully establishes the connection.

8.7 Timer 205307


Macro Name of Timer

limSendShakeToLicaT

Timer Name

LIM Send ShakeHandToLICA

Value Range

60000~600000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

When being powered on or switched to the active module, the LIM module initializes
the interception, and attempts to establish a connection with the LIG module. If the
LIM module fails to establish the connection, it starts this timer. After this timer
expires, the LIM module initializes the interception, and attempts to establish a
connection with the LIG module again. This procedure is circulated until the LIM
module successfully establishes the connection
After allocating the CallNumber data area, the LIM module sends a handshaking
message to the LICA module every the duration of this timer. If the LIM module
8-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

does not receive a handshaking response message from the LICA module, it
releases the CallNumber data area.

8-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter9
Timers Related with PBRT
Module
———————————————————————————————————————————

9.1 Timer 205401


Macro Name of Timer

PBRTWtTpAckT

Timer Name

PBRT Wait TpAck

Value Range

0~86400000ms

Default Duration
3000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of waiting for the TpInfo message from the peer
end.
1. When the outgoing service is the PBRT service, the PBRT module starts
this timer, and waits for a TpInfo message from the peer end.
2. If this timer expires, the PBRT module releases the call.

9.2 Timer 205402


Macro Name of Timer

9-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

PBRTWtAcmT

Timer Name

PBRT Wait AcmT

Value Range

0~86400000ms

Default Duration

3000ms

Adjustment Step Length

1ms

Flow Description

1. The MCC module sends a message to the PBRT module.


2. The MCC module starts this timer, and waits for an ACM message from
the PBRT module.
3. If this timer expires, the MCC module releases the call.

9.3 Timer 205403


Macro Name of Timer

PBRTWtClearT

Timer Name

PBRT Wait ClearT

Value Range

0~86400000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

9-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with PBRT Module

This timer specifies the duration of waiting for the altering response message from
the PBRT center.
1. After the PBRT module receives an alerting message, and the call
enters the stable status, the PBRT module plays the PBRT, and starts
this timer.
2. After this timer expires, the PBRT module stops playing the PBRT.

9.4 Timer 205404


Macro Name of Timer

PBRTWtRLCT

Timer Name

PBRT Wait RLCT

Value Range

0~86400000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of waiting for the release completion message of
the video PRBT.
1. After sending an MbrtReleaseEvent message to the NNI module, the
video PRBT module starts this timer, and waits for a release completion
message.
2. After receiving the release completion message, the video PRBT
module stops this timer.

9.5 Timer 205405


Macro Name of Timer

PBRTWtCcsAcmT

Timer Name

9-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

PBRT Wait Ccs ACMT

Value Range

0~2147483647ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

1. The MCC module sends a StartPBRTEvent message to the PBRT


module to start the PBRT procedure, and starts this timer.
2. After receiving a ChangePBRTTermEvent message from the PBRT
module, the MCC module stops this timer.
3. If this timer expires, the MCC module performs timeout processing.

9-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter10
Timers Related with SIPCM
Module
———————————————————————————————————————————

10.1 Timer 205501


Macro Name of Timer

SIPCM_WtStartConv

Timer Name

SIPCM Wait StartConv

Value Range

0~86400000ms

Default Duration
70000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the OP waiting for an answer message.

10.2 Timer 205502


Macro Name of Timer

SIPCM_WtAlert

Timer Name

SIPCM Wait Alert


10-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Value Range

0~65535ms

Default Duration

35000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the OP waiting for an alerting message.

10.3 Timer 205503


Macro Name of Timer

SIPCM_WtINVITE

Timer Name

SIPCM Wait INVITE

Value Range

0~65535ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the OP waiting for a SAM message.

10.4 Timer 205504


Macro Name of Timer

SIPCM_WtTpRsp

Timer Name

10-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with SIPCM Module

SIPCM Wait TpRsp

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the OP waiting for a TPINFO message.

10.5 Timer 205505


Macro Name of Timer

SIPCM_WtACK

Timer Name

SIPCM Wait ACK

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the OP waiting for an ACK message.

10.6 Timer 205506


Macro Name of Timer

SIPCM_WtCOT

10-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Timer Name

SIPCM Wait COT

Value Range

0~65535ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the OP waiting for a BCBM message.

10.7 Timer 205507


Macro Name of Timer

SIPCM_WtSetUpEvent

Timer Name

SIPCM Wait SetUpEvent

Value Range

1~120s

Default Duration

30s

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the TP waiting for an OP SETUP message.

10.8 Timer 205508


Macro Name of Timer

10-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with SIPCM Module

SIPCM_Wt180Ring

Timer Name

SIPCM Wait 180Ring

Value Range

0~65535ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the TP waiting for an alerting message.

10.9 Timer 205509


Macro Name of Timer

SIPCM_WtINVITERsp

Timer Name

SIPCM Wait INVITERsp

Value Range

0~86400000ms

Default Duration

70000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the TP waiting for an answer message.

10-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

10.10 Timer 205510


Macro Name of Timer

SIPCM_WtH248Rsp

Timer Name

SIPCM Wait H248Rsp

Value Range

0~65535ms

Default Duration

8000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of waiting for a terminal operation response.

10.11 Timer 205511


Macro Name of Timer

SIPCM_WtBYERsp

Timer Name

SIPCM Wait BYERsp

Value Range

0~65535ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of waiting for a BYTE or CANCEL response.

10-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with SIPCM Module

10.12 Timer 205512


Macro Name of Timer

SIPCM_WtEnumRsp

Timer Name

SIPCM Wait Enum Rsp

Value Range

3000~30000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of waiting for an ENUM query response from the
DNSCLIENT.

10-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


10-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter11
Timers Related with SORMUP
Module
———————————————————————————————————————————

11.1 Timer 205601


Macro Name of Timer

SORMUP_WaitAliveTest

Timer Name

SORMUP_WaitAliveTest

Value Range

0~3600000ms

Default Duration
1800000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the SORMUP module initiating an activation test.
1. After entering the stable status, the SORMUP module starts this timer.
2. After this timer expires, the SORMUP module initiates an activation test,
and restarts this timer.
3. If the SORMUP module releases the process, it stops this timer.

11.2 Timer 205602


Macro Name of Timer

11-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SORMUP_WaitAliveTestRsp

Timer Name

SORMUP_WaitAliveTestRsp

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer is used to protect the processing of activation tests.


1. When initiating an activation test, the SORMUP module starts this timer,
and waits for a response from the peer-end module.
2. After this timer expires, the SORMUP module releases the activation
test.
3. When the SORMUP module receives all activation test responses, or
needs to release the activation test, it stops this timer.

11.3 Timer 205603


Macro Name of Timer

SORMUP_WaitH248SRsp

Timer Name

SORMUP_WaitH248SRsp

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

11-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 11 Timers Related with SORMUP Module

Flow Description

This timer is used to protect the processing of reserving a circuit or releasing a


terminal between the SORMUP module and the H248S module.
1. When initiating a request for reserving a circuit or for releasing a
terminal, the SORMUP module starts this timer.
2. After this timer expires, the SORMUP module releases the process.
3. When the SORMUP module receives a response to reserving a circuit
or to releasing a terminal, or the SORMUP module needs to release the
process due to other exceptions, it stops this timer.

11.4 Timer 205604


Macro Name of Timer

SORMUP_WaitMpConnected

Timer Name

SORMUP_WaitMpConnected

Value Range

0~65535ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is used to protect the interaction between the SORMUP module and the
BCBM module.
1. When triggering the BSBM module, the SORMUP module starts this
timer.
2. After this timer expires, the SORMUP module releases the process.
3. When the SORMUP module receives all messages from the BCBM
module, the BSCM releases the process, or the SORMUP module
needs to release the process due to other causes, the SORMUP module
stops this timer.

11-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

11.5 Timer 205605


Macro Name of Timer

SORMUP_WaitMTLAck

Timer Name

SORMUP_WaitMTLAck

Value Range

0~65535ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

This timer is used to protect the MTL interaction between the SORMUP module and
the DB.
1. When initiating an asynchronization request (MTL) to the DB, the
SORMUP module starts this timer.
2. After this timer expires, the SORMUP module releases the process.
3. After receiving an MTL response from the DB, the SORMUP module
stops this timer.

11.6 Timer 205606


Macro Name of Timer

SORMUP_WaitChgThrouConnRsp

Timer Name

SORMUP_WaitChgThrouConnRsp

Value Range

0~65535ms

Default Duration

5000ms

11-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 11 Timers Related with SORMUP Module

Adjustment Step Length

1ms

Flow Description

This timer is used to protect the modification of the stream mode flow between the
SORMUP module and the H248S module.
1. After sending an EV_MC_CHANGE_THROUGH_CONN_REQ message
to the H248S module, the SORMUP module starts this timer.
2. After this timer expires, the SORMUP module releases the process.
3. After the SORMUP module receives an
EV_MC_CHANGE_THROUGH_CONN_RSP message from the H248S
module, or needs to release the process due to other causes, it stops
this timer.

11-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


11-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter12
Timers Related with TCM
Module
———————————————————————————————————————————

12.1 Timer 205701


Macro Name of Timer

Tcm_TestProtect_M

Timer Name

TCM_TestProtect

Value Range

0~600000ms

Default Duration
300000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the TCM module waiting for entering the stable
status.

12.2 Timer 205702


Macro Name of Timer

TCM_TalkingProtect_M

Timer Name
12-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

TCM_TalkingProtect

Value Range

0~70000ms

Default Duration

70000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the TCM module waiting for timeout of the call.

12.3 Timer 205703


Macro Name of Timer

TCM_CallRetry_M

Timer Name

TCM_CallRetry

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer is a TCM call retry timer.

12.4 Timer 205704


Macro Name of Timer

TCM_WaitMcPrepareRsp

12-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 12 Timers Related with TCM Module

Timer Name

TCM_WaitMcPrepareRsp

Value Range

0~65535ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the TCM module waiting for a terminal
establishment response.

12.5 Timer 205705


Macro Name of Timer

TCM_WaitSigSetupAck

Timer Name

TCM_WaitSigSetupAck

Value Range

0~65535ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the TCM module waiting for a “SIG SetupAck”
message.

12-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

12.6 Timer 205706


Macro Name of Timer

TCM_WaitSigAnswer

Timer Name

TCM_WaitSigAnswer

Value Range

0~65535ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the TCM module waiting for a “SIG Answer”
message.

12.7 Timer 205707


Macro Name of Timer

TCM_WaitMcModifyRsp

Timer Name

TCM_WaitMcModifyRsp

Value Range

0~65535ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

12-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 12 Timers Related with TCM Module

This timer specifies the duration of the TCM module waiting for a terminal
modification response.

12.8 Timer 205708


Macro Name of Timer

TCM_WaitMcAduitRsp

Timer Name

TCM_WaitMcAuditRsp

Value Range

0~65535ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the TCM module waiting for a terminal audit
response.

12.9 Timer 205709


Macro Name of Timer

TCM_WaitMcRelRsp

Timer Name

TCM_WaitMcRelRsp

Value Range

0~65535ms

Default Duration

60000ms

Adjustment Step Length

12-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1ms

Flow Description

This timer specifies the duration of the TCM module waiting for a terminal release
response.

12.10 Timer 205710


Macro Name of Timer

TCM_WaitSigRelAck

Timer Name

TCM_WaitSigRelAck

Value Range

0~65535ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the TCM module waiting for a “SIG RelAck”
message.

12-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter13
Timers Related with SPS Alarm
Module
———————————————————————————————————————————

13.1 Timer 205801


Macro Name of Timer

spsPreAlarmTrm_M

Timer Name

C_PreAlarm Dur

Value Range

0~65535ms

Default Duration
3000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the interval for performing time forecasting detections on data
areas/resources, and for detecting whether data areas are suspended.

13.2 Timer 205802


Macro Name of Timer

spsAlarmTrm_M

13-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Timer Name

C_Alarm Dur

Value Range

0~65535ms

Default Duration

3000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the interval for performing time alarm detections on data
areas/resources.

13.3 Timer 205803


Macro Name of Timer

SpsDataAreaScanTimer

Timer Name

SpsDataAreaScanTimer

Value Range

0~65535ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the interval for scanning public data areas.

13.4 Timer 205804


Macro Name of Timer
13-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 13 Timers Related with SPS Alarm Module

SpsSubDataAreaScanTimer

Timer Name

SpsSubDataAreaScanTimer

Value Range

1000~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the interval for scanning sub-data areas.

13-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


13-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter14
Timers Related with Public
Processing Module
———————————————————————————————————————————

14.1 Timer 205901


Macro Name of Timer

Common_T_ShankeHand

Timer Name

Handshake Timer

Value Range

0~6000000ms

Default Duration
1800000ms

Adjustment Step Length

1ms

Flow Description

After a call in the system, this timer expires, and the service module sends a
handshaking message to the adjacent module.

14.2 Timer 205902


Macro Name of Timer

Common_T_WaitShankeHandAck

Timer Name
14-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Wait HandShake Ack Timer

Value Range

0~600000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

After a call in the system, the service module sends a handshaking message to the
adjacent module. The service module starts this timer, and waits for a handshaking
response message from the adjacent module. If this timer expires, the handshaking
fails, and the service module releases the call.

14.3 Timer 206303


Macro Name of Timer

NNSF_NNSFGETBSCCIC

Timer Name

NNSF_NNSFGETBSCCIC

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the BSSAP waits for a GETBSCCICACK
message.

14-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 14 Timers Related with Public Processing Module

14.4 Timer 208102


Macro Name of Timer

LinkCongestShortTimer

Timer Name

Link Congest Short Timer

Value Range

1000~300000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

After the H248S process receives a congestion indication message of the


bottom-layer link, the MSCS starts this timer. Within the timer interval, the
subsequent congestion indication messages are not processed.

14.5 Timer 208103


Macro Name of Timer

LinkCongestLongTimer

Timer Name

Link Congest Long Timer

Value Range

1000~600000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description
14-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

After the H248S process receives a congestion indication message of the


bottom-layer link, the MSCS starts this timer. Within the timer interval, the
subsequent congestion indication messages are not processed.

14-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter15
Timers Related with ISDN
Module
———————————————————————————————————————————

15.1 Timer 208502


Macro Name of Timer

ISDNL3_T301

Timer Name

ISDNL3_T301

Value Range

0~300000ms

Default Duration
180000ms

Adjustment Step Length

1ms

Flow Description

During the course of a common ISDN call being connected, the originating office
waits for a response from the terminating office after receiving an alerting message
from the terminating office. The service flow is shown in the figure below.

15-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. SP A originates a call by sending a Setup message. SP B normally


connects this call and returns an Alerting message to SP A, indicating
that the called MS enters the ringing status.
2. After receiving an Alerting message, SP A starts this timer, and waits for
a response from the MS in SP B.
3. SP B sends a Connect message to SP A. SP A receives the Connect
message, and stops this timer. The flow continues.

15.2 Timer 208503


Macro Name of Timer

ISDNL3_T302

Timer Name

ISDNL3_T302

Value Range

0~45000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

15-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

The originating office sends a Setup message carrying an incomplete number. The
call processing module in the terminating office requires the originating office to
resend the number. Thus the flow of repeatedly sending a number occurs.
The service flow is shown in the figure below.

T302

1. SP A originates a call by sending a Setup message.


2. After receiving the Setup message, SP B finds that the carried number
information is not complete through the number analysis, so it sends a
SetupAck message to SP A. Then SP B starts this timer, and requires
SP A to resend the number information.
3. After receiving the SetupAck message, SP A sends the rest number
information through the Information message to SP B.
4. After SP B receives the Information message, and the call processing
module verifies that a complete number is received, SP B returns a
CallProceeding message to SP A, and stops this timer. The flow
continues.

15.3 Timer 208504


Macro Name of Timer

ISDNL3_T303

Timer Name

ISDNL3_T303

15-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Value Range

0~12000ms

Default Duration

4000ms

Adjustment Step Length

1ms

Flow Description

During the course of a common ISDN call being connected, the originating office
waits for a response from the terminating office after sending a SETUP message to
the terminating office.
The service flow is shown in the figure below.
T30
3

1. SP A originates a call by sending a Setup message, and starts this timer.


2. After receiving the Setup message, SP B returns a SETUP
ACKNOWLEDGE message to SP A.
3. After receiving the SETUP ACKNOWLEDGE message, SP A stops this
timer. The flow continues.

15.4 Timer 208505


Macro Name of Timer

ISDNL3_T304

Timer Name
15-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

ISDNL3_T304

Value Range

0~80000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

The originating office sends a Setup message carrying an incomplete number. The
call processing module in the terminating office requires the originating office to
resend the number. Thus the flow of repeatedly sending a number occurs.
The service flow is shown in the figure below.
T304

1. SP A originates a call by sending a Setup message.


2. After receiving the Setup message, SP B finds that the carried number
information is not complete through the number analysis, so it sends a
SetupAck message to SP A, and requires SP A to resend the number
information.
3. After receiving the SetupAck message, SP A sends an Information
message carrying the number, and starts this timer.

15-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

4. After receiving the Information message, SP B returns a CallProceeding


message indicating the calling processing condition to SP A after the
number analysis.
5. After receiving the CallProceeding message, SP A stops this timer. The
flow continues.

15.5 Timer 208506


Macro Name of Timer

ISDNL3_T305

Timer Name

ISDNL3_T305

Value Range

0~120000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

The call release flow is shown in the figure below.


T305

15-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

1. SP A originates a call, and SP B answers this call. The call enters the
conversation status.
2. After the call ends, the network side of SP A originates the call release
procedure. SP A judges that it is not required to play tones to the
subscriber, so it sends a Disconnect message indicating clearing to SP
B, and starts this timer.
3. After receiving the Disconnect message, SP B returns a release
message to SP A after releasing the bearer resources.
4. After receiving the Release message, SP A stops this timer. The flow
continues.

15.6 Timer 208507


Macro Name of Timer

ISDNL3_T306

Timer Name

ISDNL3_T306

Value Range

0~120000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

The call release flow is shown in the figure below.

15-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

T306

1. SP A originates a call, and SP B answers this call. The call enters the
conversation status.
2. After the call ends, the network side of SP A originates the call release
procedure. SP A judges that it is required to play tones to the subscriber,
so it sends a Disconnect message indicating clearing to SP B (carrying
progress indicator No.8), and starts this timer.
3. After receiving the Disconnect message, SP B returns a release
message to SP A after releasing the bearer resources.
4. After receiving the Release message, SP A stops this timer. The flow
continues.

15.7 Timer 208508


Macro Name of Timer

ISDNL3_T307

Timer Name

ISDNL3_T307

Value Range

0~640000ms

Default Duration

180000ms

15-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

Adjustment Step Length

1ms

Flow Description

This function is not supported at present, so this timer is not used.


The call suspension flow is shown in the figure below.

SP A SP B
SETUP

SETUP ACKNOWLEDGE

CONNECT

CONNECT ACKNOWLEDGE

Conversation status
SUSPEND

SUSPEND ACKNOWLEDGE

RESUME

RESUME ACKNOWLEDGE

1. SP A originates a call, and SP B answers this call. The call enters the
conversation status.
2. During the course of conversation, SP A initiates the suspension
operation to hold the call by sending a SUSPEND message to SP B.
3. After SP B receives the SUSPEND message, the call processing
module processes the message and returns a SUSPEND
ACKNOWLEDGE message to SP A. Then SP B starts this timer, and
waits for a restoration operation.
4. After receiving a RESUME message, SP B restores the call, and returns
a RESUME ACKNOWLEDGE message. Then SP B stops this timer.
The flow continues.

15.8 Timer 208509


Macro Name of Timer

15-9

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

ISDNL3_T308

Timer Name

ISDNL3_T308

Value Range

0~12000ms

Default Duration

4000ms

Adjustment Step Length

1ms

Flow Description

The call release flow is shown in the figure below.


T308

1. SP A originates a call, and SP B answers this call. The call enters the
conversation status until the call is released.
2. The subscriber in SP A hangs up, and sends a Disconnect message to
SP B.
3. After receiving the Disconnect message, SP B releases the bearer. The
call processing module processes the message and returns a Release
message to SP A. Then SP B starts this timer, and waits for a response
message.

15-10

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

4. After receiving the Release message, SP A returns a “Release


Complete” message to SP B after releasing the bearer at the local end.
5. After receiving the “Release Complete” message, SP B stops this timer.
The flow continues.

15.9 Timer 208510


Macro Name of Timer

ISDNL3_T309

Timer Name

ISDNL3_T309

Value Range

0~240000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

When a call is in the stable status, after the system detects exceptions on the
signaling channel or receives a clearing directive of the D channel, it starts this timer.
If the signaling channel has been restored before this timer expires, the call
continues without influence. If this timer expires, the system releases the call, and
erases the information related with this call. This timer is only started when a call is
in the conversation status. If the system detects exceptions on the signaling channel
when a call is in the ringing status, it directly releases the call.

15.10 Timer 208511


Macro Name of Timer

ISDNL3_T310

Timer Name

ISDNL3_T310

Value Range
15-11

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

0~40000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

The ringing flow of a common ISDN call is shown in the figure below.
T31
0

1. SP A originates a call by sending a Setup message. After SP B receives


this message, and the call processing module performs number analysis,
SP B returns a “Call Proceeding” message to SP A after verifying
whether the call is terminated or transferred.
2. After receiving the “Call Proceeding” message, SP A starts this timer,
and waits for an Alerting message.
3. After establishing the bearer, SP B returns an Alerting message to SP A.
After receiving the Alerting message, SP A stops this timer.

15.11 Timer 208512


Macro Name of Timer

ISDNL3_T312

Timer Name

ISDNL3_T312
15-12

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

Value Range

0~16000ms

Default Duration

8000ms

Adjustment Step Length

1ms

Flow Description

This function is not supported at present, so this timer is not used.


In the multi-point-broadcast signaling networking environment, the ISDN call
connection flow is shown in the figure below.

Multi-point
SP A Broadcast
SETUP Network
T312

SETUP
T312

SETUP ACKNOWLEDGE

CALL PROCEEDING

ALERTING

CONNECT

1. SP A originates a call by sending a Setup message, and starts this timer.


2. If SP A has not received a “SETUP ACKNOWLEDGE” message before
this timer expires, it restarts this timer, and resends the Setup message.
3. If SP A has received a “SETUP ACKNOWLEDGE” message from the
broadcast network before this timer expires, it stops this timer. The flow
continues.

15.12 Timer 208513


Macro Name of Timer

ISDNL3_T316

Timer Name
15-13

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

ISDNL3_T316

Value Range

0~480000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

During the initialization flow of D channel establishment, after Q931 receives a


message of acknowledging establishment of a D channel, if no call in the stable
status exists on this D channel, the flow of restarting all interfaces is triggered. The
ISDN module sends a RESTART message. Then it starts this timer, and waits for a
“RESTART ACKNOWLEDGE” message. On the first expiry of this timer, the ISDN
module resends a RESTART message and restarts this timer. On the second expiry
of this timer, ISDN module releases the data area, and waits for the flow of
establishing another D channel.

15.13 Timer 208514


Macro Name of Timer

ISDNL3_T317

Timer Name

ISDNL3_T317

Value Range

0~240000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

This function is not supported at present, so this timer is not used.


15-14

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

15.14 Timer 208515


Macro Name of Timer

ISDNL3_T320

Timer Name

ISDNL3_T320

Value Range

0~120000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This function is not supported at present, so this timer is not used.

15.15 Timer 208516


Macro Name of Timer

ISDNL3_T321

Timer Name

ISDNL3_T321

Value Range

0~120000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This function is not supported at present, so this timer is not used.

15-15

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

15.16 Timer 208517


Macro Name of Timer

ISDNL3_T322

Timer Name

ISDNL3_T322

Value Range

0~12000ms

Default Duration

4000ms

Adjustment Step Length

1ms

Flow Description

During the initialization flow of D channel establishment, after Q931 receives a


message of acknowledging establishment of a D channel, if any call in the stable
status exists on this D channel, the ISDN module sends a “STATUS ENQ” message
to the peer end to query the status. Then it starts this timer, and waits for a STATUS
message.

15.17 Timer 208518


Macro Name of Timer

ISDNL3_T329

Timer Name

ISDNL3_T329

Value Range

0~360000ms

Default Duration

90000ms

Adjustment Step Length

15-16

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

1ms

Flow Description

The ISDN module queries the status of a call instance at the peer end when a call is
in the activation status. During a call in the stable status, when the ISDN module
receives a status indication message from the peer end indicating that a call
instance at the peer end is in the number sending, ringing, answering, or call
connection status, it holds the call, and starts this timer. If this timer expires, the
ISDN module queries the information of the call data area at another side.

15.18 Timer 208519


Macro Name of Timer

ISDN_TGCM_SETUPACK

Timer Name

ISDN_TGCM_SETUPACK

Value Range

0~10000ms

Default Duration

3000ms

Adjustment Step Length

1ms

Flow Description

After receiving a SETUP message from the calling MS, the incoming side sends an
internal message (EV_L3L4_SETUP_IND) to the GCM module. The service flow is
shown in the figure below.

15-17

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

ISDN_TID_WaitL4SETUPAC
K

1. After receiving a SETUP message from the calling MS, the ISDNL3
module at the incoming side sends an internal message
(EV_L3L4_SETUP_IND) to the GCM module. Then it starts this timer,
and waits for an EV_L4L3_SETUP_ACK message from the GCM
module.
2. After receiving the EV_L3L4_SETUP_IND message, the GCM module
sends the EV_L4L3_SETUP_ACK message to the ISDNL3 module.
After receiving the EV_L4L3_SETUP_ACK message, the ISDNL3
module stops this timer. The call continues.

15.19 Timer 208520


Macro Name of Timer

ISDN_TGCM_ALERTING

Timer Name

ISDN_TGCM_ALERTING

Value Range

0~180000ms

Default Duration

60000ms

Adjustment Step Length

1ms
15-18

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

Flow Description

After receiving an EV_L4L3_CallProced_IND message from the GCM module, the


ISDNL3 module at the incoming side waits for an alerting message from the called
MS. The service flow is shown in the figure below.

ISDNL3 GCM

EV_L3L4_Setup_IND

EV_L4L3_Setup_ACK

EV_L4L3_CallProced_IND

EV_L4L3_Alerting_IND

EV_L4L3_Answer_IND

1. After receiving a SETUP message from the calling MS, the ISDNL3
module at the incoming side sends an internal message
(EV_L3L4_SETUP_IND) to the GCM module. After receiving the
message, the GCM module performs number analysis to decide
whether the call is terminated or transferred to another office. Then the
GCM module sends an EV_L4L3_CallProced_IND message to the
ISDNL3 module.
2. After receiving the EV_L4L3_CallProced_IND message, the ISDNL3
module at the incoming side starts this timer, and waits for an
EV_L4L3_Alerting_IND message from the GCM module. At the same
time, the ISDNL3 module sends an ISDNL3_CALLPROC_M message
to the calling MS to notify it of this call being connected.
3. After receiving an Alerting message from the called MS, the GCM
module at the CPCI side sends an EV_L4L3_Alerting_IND message to
the ISDNL3 module. After receiving the message, the ISDNL3 module
stops this timer, and sends an ISDNL3_Alerting _M message to the
calling MS. The call continues.

15.20 Timer 208521


Macro Name of Timer

ISDN_TGCM_ANSWER
15-19

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Timer Name

ISDN_TGCM_ANSWER

Value Range

0~300000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

After receiving an EV_L4L3_Alerting_IND message from the GCM module, the


ISDNL3 module at the incoming side waits for an answering message from the
called MS. The service flow is shown in the figure below.

ISDNL3 GCM

EV_L3L4_Setup_IND

EV_L4L3_Setup_ACK

EV_L4L3_CallProced_IND
ISDN_TID_WaitL4ANSWE

EV_L4L3_Alerting_IND
R

EV_L4L3_Answer_IND

1. After receiving a SETUP message from the calling MS, the ISDNL3
module at the incoming side tells the GCM module to normally connect
the call until the GCM module receives an alerting message from the
called MS. Then the GCM module sends an EV_L4L3_Alerting_IND
message to the ISDNL3 module.
2. After receiving the EV_L4L3_Alerting_IND message from the GCM
module, the ISDNL3 module at the incoming side starts this timer, and
waits for the subsequent response message from the GCM module.

15-20

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

3. After receiving the EV_L4L3_Answer_IND message from the GCM


module, the ISDNL3 module stops this timer, and sends an
ISDNL3_Answer _M message to the calling MS. The call enters the
conversation status.

15.21 Timer 208522


Macro Name of Timer

ISDN_TGCM_TPCALLACK

Timer Name

ISDN_TGCM_TPCALLACK

Value Range

0~10000ms

Default Duration

3000ms

Adjustment Step Length

1ms

Flow Description

After the ISDNL3 module at the outgoing side receives a GETTPCIC message from
the DB, an outgoing call flow is triggered. The service flow is shown in the figure
below.

15-21

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

GCM ISDNL3

EV_L3L4_TPCall_IND

EV_L4L3_TPCall_ACK

EV_L4L3_Setup_IND

EV_L3L4_CallProced_IND

EV_L3L4_Alerting_IND

EV_L3L4_Answer_IND

1. After receiving a GETTPCIC message from the DB, the ISDNL3 module
at the outgoing side sends an EV_L3L4_TPCall_IND message to the
GCM module. Then it starts this timer, and waits for a response
message from the GCM module.
2. After receiving the EV_L3L4_TPCall_IND message from the ISDNL3
module, the GCM module at the CPCO side sends an
EV_L4L3_TPCall_ACK message to the ISDNL3 module.
3. After receiving the EV_L4L3_TPCall_ACK message from the GCM
module, the ISDNL3 module at the outgoing side stops this timer. The
call continues.

15.22 Timer 208523


Macro Name of Timer

ISDN_TGCM_SETUPIND

Timer Name

ISDN_TGCM_SETUPIND

Value Range

0~30000ms

Default Duration

15000ms

15-22

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

Adjustment Step Length

1ms

Flow Description

After the ISDNL3 module at the outgoing side receives an EV_L4L3_TPCall_ACK


message from the GCM module, an outgoing call flow is triggered. The service flow
is shown in the figure below.

GCM ISDNL3

EV_L3L4_TPCall_IND

EV_L4L3_TPCall_ACK

EV_L4L3_Setup_IND

EV_L3L4_CallProced_IND

EV_L3L4_Alerting_IND

EV_L3L4_Answer_IND

1. After receiving a GETTPCIC message from the DB and an


EV_L4L3_TPCall_ACK message from the GCM module, the ISDNL3
module at the outgoing side starts this timer, and waits for the
subsequent message from the GCM module.
2. After receiving a Setup message from the calling MS, the GCM module
at the CPCO side sends an EV_L4L3_Setup _IND message to the
ISDNL3 module.
3. After receiving the EV_L4L3_Setup_IND message, the ISDNL3 module
at the outgoing side stops this timer, and sends an ISDNL3_Setup _M
message to the called MS. The call continues.

15.23 Timer 208524


Macro Name of Timer

ISDN_TGCM_RELEASEACK

Timer Name

15-23

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

ISDN_TGCM_RELEASEACK

Value Range

0~20000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the call release flow (containing the following two cases), the ISDNL3
module waits for a release response message from the GCM module.
z The ISDNL3 module initiates a call release flow.
z The GCM module initiates a call release flow.
The service flow is shown in the figure below.
ISDN_TID_WaitL4RELACK

15-24

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

GCM ISDNL3

EV_L3L4_TPCall_IND

EV_L3L4_Answer_IND

Conversation status

EV_L4L3_Release_IND

EV_L3L4_Release_Rsp

EV_L4L3_Release_ACK

(b)

z The ISDNL3 module initiates a call release flow.


i. After receiving an ISDNL3_Disconnect _M message from the peer end,
the ISDNL3 module sends an EV_L3L4_Release_IND message to tell
the GCM module to release this call. Then it starts this timer, and waits
for a release response message from the GCM module.
ii. After receiving the EV_L3L4_Release_IND message from the ISDNL3
module, the GCM module tells the peer end to release this call. After the
call is released, the GCM module sends an EV_L4L3_Release_ACK
message to the ISDNL3 module.
iii. After receiving the EV_L4L3_Release_ACK message from the GCM
module, the ISDNL3 module stops this timer, and sends an
ISDNL3_Release _M message to the peer end. Then it waits for a
release completion message from the peer end.
z The GCM module initiates a call release flow.
i. The GCM module sends an EV_L4L3_Release_IND message to tell the
ISDNL3 module to release this call.
ii. After receiving the EV_L4L3_Release_IND message from the GCM
module, the ISDNL3 module sends an ISDNL3_Disconnect _M
message to tell the peer end to release this call. Then it waits for a
release response message from the peer end.
iii. After receiving the ISDNL3_Release _M message from the peer end,
the ISDNL3 module sends an EV_L3L4_Release_Rsp message to the
GCM module. Then it starts this timer, and waits for a response
message from GCM module.
iv. After receiving the EV_L3L4_Release_Rsp message from the ISDNL3
module, the GCM module sends an EV_L4L3_Release_ACK message
15-25

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

to the ISDNL3 module.


v. After receiving the EV_L4L3_Release_ACK message from the GCM
module, the ISDNL3 module stops this timer, and sends an
ISDNL3_Release Complete_M message to the peer end. This call is
released.

15-26

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter16
Timers Related with CAS
Module
———————————————————————————————————————————

16.1 Timer 208601


Macro Name of Timer

CAS_T1_WtAddr

Timer Name

CAS_T1_WtAddr

Value Range

0~300000ms

Default Duration
180000ms

Adjustment Step Length

1ms

Flow Description

The R2 module at the incoming side receives an


EV_L4L3_CALLPROCEEDING_IND message from the GCM module, and waits for
receiving numbers. The service flow is shown in the figure below.

16-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. The R2 module at the incoming side receives an


EV_L4L3_CALLPROCEEDING_IND message from the GCM module,
and waits for receiving numbers.
2. The R2 module at the incoming side sends a number receiving request
to the MGW through the H248 module. Then it starts this timer, and
waits for the number receiving result.
3. After receiving a number receiving completion (EV_MC_R2_ADDR_IND)
message, the R2 module at the incoming side stops this timer.

16.2 Timer 208602


Macro Name of Timer

CAS_T2_WtCf

Timer Name

CAS_T2_WtCf

Value Range

0~65535ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.


16-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

TIMER_WTCF

1. The R2 module sends a CB request message, and starts this timer.


2. After receiving the forward release message from the H248S module,
the R2 module stops this timer.

16.3 Timer 208603


Macro Name of Timer

CAS_T3_WtSza

Timer Name

CAS_T3_WtSza

Value Range

0~65535ms

Default Duration

3000ms

Adjustment Step Length

1ms

Flow Description

16-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

The service flow is shown in the figure below.

GCM R2 H248S
EV_L4L3_SETUP_IN
D

EV_L3L4_SETUP_AC
K
EV_MC_R2_SZSIG_RE
Q

EV_MC_R2_SZSIG_RS
TIMER_WTSZA

EV_MC_R2_SZA_IND

1. The R2 module receives an L4L3_SETUP message from the GCM


module, carrying the CIC and the MGW ID that the GCM has applied for
and used for establishing a terminal. The R2 module returns a response
message to the GCM module.
2. The R2 module sends a signal seizing request message to the MGW
through the H248S module. Then it starts this timer, and waits for a
response message.

16.4 Timer 208604


Macro Name of Timer

CAS_T4_WtCprs

Timer Name

CAS _T4_WtCprs

Value Range

0~300000ms

Default Duration

180000ms

Adjustment Step Length

1ms
16-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

Flow Description

The service flow is shown in the figure below.

GCM R2 H248S

EV_L4L3_INFORMATION_IND

EV_MC_R2_ADDRSIG_RE
Q

EV_MC_R2_ADDRSIG_RS
TIMER_WTCPRS

EV_MC_R2_CPRS_IN
D

1. The R2 module receives an L3L4_INFOMATION message from the


GCM module, carrying the CIC and the office ID.
2. The R2 module successfully seizes the line signal and sends the
number information to the MGW through the H248S module. Then it
receives a response message from the MGW.
3. After receiving the status signal of the called party (indicating the
completion of number receiving) from the MGW, the R2 module stops
this timer.

16.5 Timer 208605


Macro Name of Timer

CAS_T5_WtRlg

Timer Name

CAS _T5_WtRlg

Value Range

0~65535ms

Default Duration

30000ms

16-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

1. The R2 module sends a request for sending CF forward clearing signal


to the MGW through the H248S module, and starts this timer.
2. After receiving the RLG signal from the MGW, the R2 module stops this
timer.

16.6 Timer 208606


Macro Name of Timer

CAS_T6_WtAlert

Timer Name

CAS _T6_WtAlert

Value Range

0~180000ms

Default Duration

16-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

180000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

1. After receiving the number information from the H248S module, the R2
module reports it through the INFORMATION message to the GCM
module, and starts this timer.
2. After receiving an ALERTING message, the R2 module stops this timer.

16.7 Timer 208608


Macro Name of Timer

CAS_T8_WtSetup

Timer Name

CAS _T8_WtSetup

Value Range

0~65535ms

Default Duration

10000ms

Adjustment Step Length

16-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1ms

Flow Description

The service flow is shown in the figure below.

1. After receiving a message (bring the attribute information of the GCM


module to the GCM module) from the GCM module, the R2 module
starts this timer.
2. The GCM module establishes a terminal at the 248 side (not shown in
the above figure). After receiving an L4L3_SETUP message from the
GCM module, the R2 module stops this timer.

16.8 Timer 208610


Macro Name of Timer

CAS_T9_IntToll

Timer Name

CAS_T9_IntToll

Value Range

0~120000ms

Default Duration

120000ms

Adjustment Step Length

16-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

1ms

Flow Description

The service flow is shown in the figure below.

1. After receiving a CPRSSIG_RSP message, the R2 module sends a


RBT_ACK message to the GCM module, and starts this timer.
2. After receiving the RBT_ACK message, the GCM module sends a
response message to the R2 module. After receiving the response
message, the R2 module stops this timer.

16.9 Timer 208613


Macro Name of Timer

CAS_T10_WtH248sRsp

Timer Name

CAS_T10_WtH248sRsp

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

16-9

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Flow Description

This timer is used to wait for a response from the H248S module after the MSCS
CAS module sends an event to the H248S module. The corresponding timers
include TIMER_WTSZRSP and TIMER_WTADDRRSP.
The service flow is shown in the figure below.

1. The R2 module sends a seizure request message to the H248 module,


and starts this timer.
2. After the H248 module returns a seizure response message, the R2
module stops this timer.

16.10 Timer 208614


Macro Name of Timer

CAS_T11_BillPulseIntvl

Timer Name

CAS_T11_BillPulseIntvl

Value Range

0~300000ms

Default Duration

180000ms

Adjustment Step Length


16-10

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

1ms

Flow Description

This timer is dedicated for India and Brazil.


1. During a call, when the MSCS receives a message of expiry of this timer,
it sends an EV_MC_R2_MTSIG_REQ message to the H248S module.
2. After the call ends, the MSCS stops this timer.

16.11 Timer 208615


Macro Name of Timer

CAS_T12_WtAddrOL

Timer Name

CAS_T12_WtAddrOL overlap

Value Range

0~65535ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

16-11

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

H248S R2

EV_MC_R2_ADDREVT_REQ(x)

EV_MC_R2_ADDR_IND

In the OVERLAP mode, when the incoming side waits for receiving numbers, the
duration of this timer is that of receiving one digit.

16.12 Timer 208616


Macro Name of Timer

CAS_T13_DelaySndRlg

Timer Name

CAS_T13_DelaySendRelGud

Value Range

0~65535ms

Default Duration

500ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

16-12

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

1. After receiving a message, the CAS module starts this timer.


2. If this timer expires, the CAS module sends a RLG message.

16.13 Timer 208617


Macro Name of Timer

CAS_T14_WtCb

Timer Name

CAS_T14_WtCb

Value Range

0~65535ms

Default Duration

2000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

16-13

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. The R2 module sends a forward release request message to the H248


module, and starts this timer.
2. After receiving the backward release message from the H248 module,
the R2 module stops this timer.

16.14 Timer 208618


Macro Name of Timer

CAS_T15_WtReAns

Timer Name

CAS_T15_WtReAns

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

This timer is dedicated for the operators of Indonesia.


The service flow is shown in the figure below.

16-14

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

1. After the R2 module receives the backward on-hook signal, and if the
protocol is the Indonesia sub protocol, the R2 module starts this timer.
2. After receiving a Reans message, the R2 module stops this timer.

16.15 Timer 208619


Macro Name of Timer

CAS_TGCM_WTSETUPACK

Timer Name

CAS_TGCM_WTSETUPACK

Value Range

0~65535ms

Default Duration

3000ms

Adjustment Step Length

16-15

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1ms

Flow Description

The service flow is shown in the figure below.

1. After sending a SetupInd message to the GCM module, the R2 module


starts this timer.
2. After receiving the SetupInd message, the GCM module creates a data
area, and sends the GCM process message through the SetupAck
message to the R2 module. The R2 module stops this timer.

16.16 Timer 208620


Macro Name of Timer

CAS_TGCM_WTCALLPROCEED

Timer Name

CAS_TGCM_WTCALLPROCEED

Value Range

0~65535ms

Default Duration

10000ms
16-16

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

1. After receiving a SETUP_ACK message (bringing the GCM process


message to the R2 module) from the GCM module, the R2 module
starts this timer.
2. The GCM module sends a message to tell the R2 module to receive
numbers. The R2 module stops this timer.

16.17 Timer 208621


Macro Name of Timer

CAS_TGCM_WTINFOREQ

Timer Name

CAS_TGCM_WTINFOREQ

Value Range

0~300000ms

16-17

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Default Duration

180000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.


TIMER_WTINFOREQ

1. When the R2 module receives the number information from the H248
module for the first time, the R2 module sends it through the information
message to the GCM module, and starts this timer.
2. After the GCM module receives enough digits of the called number, it
performs number analysis. The GCM module sends an inforequest
message (containing the min length and max length of the called
number, and the location information of the calling MS) to the R2
module. Then the R2 module stops this timer.

16.18 Timer 208622


Macro Name of Timer

CAS_TGCM_RELACK

Timer Name

CAS_TGCM_RELACK

Value Range

16-18

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

0~65535ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

The called MS initiates


the call release

H248S R2 GCM

EV_L4L3_RELEASE_IND

EV_MC_R2_RLG_RSP EV_L3L4_RELEASE_RSP
TIMER_WTRELACK

EV_L4L3_RELEASE_ACK

16-19

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. No matter whether the calling MS or the called MS initiates the call


release, the R2 module notifies the GCM module, and starts this timer.
2. The GCM module clears the terminal created at the H248 side, and then
sends a RELEASE_ACK message to the R2 module. The R2 module
stops this timer.

16.19 Timer 208623


Macro Name of Timer

CAS_TGCM_TPCALLACK

Timer Name

CAS_TGCM_TPCALLACK

Value Range

0~65535ms

Default Duration

3000ms

Adjustment Step Length

1ms
16-20

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

Flow Description

The service flow is shown in the figure below.

1. After receiving a DM_GETTPCIC message, the R2 module establishes


a call data control area, and sends a TPCALL_IND message to the
GCM module. Then the R2 module starts this timer.
2. The GCM module sends a TPCALL_ACK message to the R2 module.
After receiving the TPCALL_ACK message, the R2 module stops this
timer.

16.20 Timer 208624


Macro Name of Timer

SIG_NUMCOMPLETE

Timer Name

CAS_NUM_COMPLETE

Value Range

0~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

16-21

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Flow Description

The service flow is shown in the figure below.

1. After receiving an INFOREQUEST message from the GCM module, the


R2 module starts this timer.
2. The R2 sends the information through the ADDREVT message to the
H248S module. After receiving the number information from the peer
end, the R2 module stops this timer.

16-22

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter17
Timers Related with AGR
Module
———————————————————————————————————————————

17.1 Timer 208651


Macro Name of Timer

agrTmrWaitHookOn

Timer Name

AGR Wait HookOn

Value Range

1000~65535ms

Default Duration
15000ms

Adjustment Step Length

1ms

Flow Description

AGR GCM

L3L4_Release_ind

L3L4_release_Ack

17-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

This timer specifies the duration of waiting for on-hook after the AGR module plays
the fast busy tone.
After receiving a release message from the GCM module, the AGR module plays
the fast busy tone to the subscriber, and starts this timer. If the AGR module has
received an on-hook message from the subscriber before this timer expires, it sets
the AT terminal to on-hook status, sends a release response to the GCM module,
and releases the call data area. If the AGR module has not received an on-hook
message from the subscriber before this timer expires, it sends a release response
to the GCM module, and releases the call data area.

17.2 Timer 208652


Macro Name of Timer

agrTmrWaitDTRsp

Timer Name

AGR Wait DialTone Response

Value Range

1000~65535ms

Default Duration

2000ms

Adjustment Step Length

1ms

Flow Description

AGR H248

EV_MC_AGR_SEND_TONE_DIGIT_REQ

EV_MC_AGR_SEND_TONE_DIGIT_Rsp

This timer specifies the duration of the AGR module waiting for a tone-playing
success response.

17-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

After sending a request for playing the dialing tone to the H248S module, the AGR
module starts this timer. If the AGR module has received a response from the
H248S module before this timer expires, it stops this timer, and waits for the
completion of tone playing. If this timer expires, the AGR module reports failure,
stops playing the dialing tone, and plays the fast busy tone.

17.3 Timer 208653


Macro Name of Timer

agrTmrWaitDTCmp

Timer Name

AGR Wait DialTone Complete

Value Range

1000~65535ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the AGR module waiting for the completion of
tone-playing.
After receiving a response message of successfully playing the dialing tone from the
H248S module, the AGR module stops timer agrTmrWaitDTRsp, and starts timer
agrTmrWaitDTCmp. If the AGR module has received a tone-playing completion
notification from the H248S module before timer agrTmrWaitDTCmp expires, it
stops this timer, and starts timer agrTmrWaitDNCmp. If timer agrTmrWaitDTCmp
expires, the AGR module reports failure, and plays the fast busy tone.
17-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

17.4 Timer 208654


Macro Name of Timer

agrTmrWaitDNCmp

Timer Name

AGR Wait Dialed Number Complete

Value Range

1000~65535ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

AGR H248

EV_MC_TONE_CMPLT_IND

EV_TONE_PREPORT_DTMF_IND

This timer specifies the duration of the AGR module waiting for the completion of
receiving numbers.
After receiving a notification of playing the dialing tone being completed, the AGR
module starts this timer. If the AGR module has received a number-receiving
completion notification from the H248S module before this timer expires, it returns a
response message to the H248S module. If this timer expires, the AGR module
reports failure, and plays the fast busy tone.

17.5 Timer 208655


Macro Name of Timer

agrTmrWaitAlRiRsp

17-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

Timer Name

AGR Wait Al Ring Response

Value Range

1000~65535ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

AGR GCM

EV_L3L4_SETUP_ACK

EV_L3L4_ALERT_IND

This timer specifies the duration of the AGR module waiting for a ringing response
message.
After sending a response message to the GCM module, the AGR module sends an
alerting request to the H248 module, and starts this timer. If the AGR module has
received an alerting response message from the H248 module before this timer
expires, it stops this timer, and migrates to the alerting status. If this timer expires,
the AGR module reports failure, and releases the GCM module.

17.6 Timer 208656


Macro Name of Timer

agrTmrWaitAlAnswer

Timer Name

AGR Wait Al Answer

Value Range

17-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1000~65535ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

AGR H248S

EV_MC_AL_RING_RSP

EV_MC_AL_OFF_IND

This timer specifies the duration of the AGR module waiting for the called party to
answer the call.
After receiving an alerting response message from the H248 module, the AGR
module sends a terminal alerting message to the GCM module, and starts this timer.
If the AGR module has received an on-hook message from the H248 module before
this timer expires, it sends an answer message to the GCM module, and modifies
the status of the terminal to the answer status. If this timer expires, the AGR module
reports failure, and releases the GCM module.

17.7 Timer 208657


Macro Name of Timer

agrTmrWaitSBTRsp

Timer Name

AGR Wait ShortBusyTone Rsp

Value Range

1000~65535ms

Default Duration

2000ms
17-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

Adjustment Step Length

1ms

Flow Description

AGR H248

EV_MC_AGR_SEND_TONE_REQ

EV_MC_AGR_SEND_TONE_RSP

This timer specifies the duration of the AGR module waiting for success in playing
the fast busy tone.
After sending a request for playing the fast busy tone to the H248 module, the AGR
module starts this timer. If the AGR module has received a message of success in
playing the fast busy tone from the H248 module before this timer expires, it stops
this timer, and enters the release status. If this timer expires, the AGR module
releases the GCM module.

17.8 Timer 208658


Macro Name of Timer

agrTmrWaitAlert

Timer Name

AGR Wait TP Alert

Value Range

1000~30000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

17-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

AGR GCM

EV_L3L4_INFORMATION_IND

EV_L3L4_ALERT_IND

This timer specifies the duration of the AGR module waiting for an alerting
message.
After sending an Information message to the GCM module, the AGR module starts
this timer. If the AGR module has received an alerting message of the called party
from the GCM module before this timer expires, it judges bToneTestFlag. If
bToneTestFlag is 0, non-tone resources are monitored. In this case, the AGR
module modifies the status of the data area to alerting status, and starts timer
agrTmrWaitAnswer. If bToneTestFlag is 1, the AGR module starts timer
agrTmrWaitMRBPlayCmp. If this timer expires, the AGR module reports failure, and
releases the GCM module.

17.9 Timer 208659


Macro Name of Timer

agrTmrWaitAnswer

Timer Name
AGR Wait TP Answer

Value Range

1000~120000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

17-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

AGR GCM

EV_L4L3_ALERTING_IND

EV_L4L3_ANSWER_IND

This timer specifies the duration of the AGR module waiting for an answer
message.
After receiving an alerting message of the called party from the GCM module, the
AGR module starts this timer. If the AGR module has received an answer message
of the called party from the GCM module before this timer expires, it modifies the
status of the calling data area to conversation status. If this timer expires, the AGR
module reports failure, and releases the GCM module.

17.10 Timer 208660


Macro Name of Timer

agrTmrWaitMRBPlayCmp

Timer Name

AGR Wait MRB Play Complete

Value Range
1000~180000ms

Default Duration

180000ms

Adjustment Step Length

1ms

Flow Description

17-9

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

AGR GCM

EV_L4L3_ALERTING_IND

EV_L4L3_RELEASE_IND

This timer specifies the duration of the AGR module waiting for the completion of
playing the monitored tone.
After receiving an alerting message from the GCM module, the AGR module judges
bToneTestFlag. If bToneTestFlag is 1, the tone resources are monitored. In this
case, the AGR module starts this timer. Before this timer expires, the MRB tone is
being played. After this timer expires, the AGR module sends a release message to
the GCM module to stop playing the MRB tone.

17.11 Timer 208661


Macro Name of Timer

agrTmrWaitCprs

Timer Name

AGR Wait Cprs

Value Range
1000~65535ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

17-10

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

AGR GCM

EV_L4L3_SETUP_ACK
T1

EV_L4L3_CALLPROCEDING_IND

This timer specifies the duration of the AGR module waiting for the GCM module to
prepare a terminal.
After receiving an off-hook signal, the AGR module sends a SETUPIND message to
the GCM module, and then starts this timer. After receiving a CallProceeding
message from the GCM module, the AGR module stops this timer. If this timer
expires, the AGR module sends a release message to the GCM module.

17.12 Timer 208662


Macro Name of Timer

agrTmrWaitTpCallAck

Timer Name

AGR Wait Tp Call Ack

Value Range

1000~65535ms

Default Duration

2000ms

Adjustment Step Length

1ms

Flow Description

17-11

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

AGR GCM

EV_L3L4_RELEASE_IND

EV_L4L3_RELEASE_RSP

This timer specifies the duration of the AGR module waiting for a release response
message from the GCM module.
After sending a RELEASEIND message to the GCM module, the AGR module
starts this timer. After receiving an L4L3_RELEASE_RS message from the GCM
module, the AGR module stops this timer. If this timer expires, the AGR module
directly releases the local data area.

17.13 Timer 208663


Macro Name of Timer

agrTmrWaitRelAck

Timer Name

AGR Wait Release Ack

Value Range
1000~65535ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

17-12

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 17 Timers Related with AGR Module

AGR GCM

EV_L4L3_TPCALL_ACK

EV_L4L3_SETUP_IND

This timer specifies the duration of the AGR module waiting for a SETUP message
from the GCM module.
After receiving an L4L3_TPCALL_ACK message from the GCM module, the AGR
module starts this timer. After receiving an L4L3_SETUP_IND message from the
GCM module, the AGR module stops this timer. If this timer expires, the AGR
module sends a release message to the GCM module.

17.14 Timer 208664


Macro Name of Timer

agrTmrWaitSetup

Timer Name

AGR Wait Setup

Value Range
1000~65535ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the AGR module waiting for a SETUP message
from the GCM module.

17-13

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

AGR GCM

EV_L3L4_TPCALL_IND

EV_L4L3_TPCALL_ACK

This timer specifies the duration of the AGR module waiting for a TPCALL ACK
message from the GCM module.
After receiving a get_tpcic message from the DB module, the AGR module sends
an L3L4_TPCALL_IND message to the GCM module, and starts this timer. After
receiving a TPCALL ACK message from the GCM module, the AGR module stops
this timer. If this timer expires, the AGR module initiates the release procedure.

17-14

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter18
Timers Related with TUP
Module (ITU Protocol)
———————————————————————————————————————————

18.1 Timer 208701


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T0

Timer Name

SS7_TIMER_TUP_ITUT_T0

Value Range

0~240000ms

Default Duration
120000ms

Adjustment Step Length

1ms

Flow Description 1

After the TUP module receives an EV_L4L3_ALERTING_IND message from the


GCM module, and the “(Incoming) Send UNN When TUP Play Blank Tone” trunk
switch is opened, the TUP module sends an UNN message to the peer end. Then it
starts this timer, and waits for an EV_L4L3_ANSWER_IND message. If this timer
expires, the TUP module sends a CFL message to the L3 module.
The service flow is shown in the figure below.

18-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

TUP GCM

EV_L4L3_ALERTING_IND
UNN

EV_L4L3_ANSWER_IND

CFL

Flow Description 2

After receiving an EV_L4L3_ALERTING_IND message from the GCM module, the


TUP module sends an ACM message to the peer end. Then it starts this timer, and
waits for an EV_L4L3_ANSWER_IND message. If this timer expires, the TUP
module sends a CFL message to the L3 module. The service flow is shown in the
figure below.
T0

Flow Description 3

After receiving an ACM message from the peer end, the TUP module starts this
timer, and waits for an ANM message from the peer end. If this timer expires, the
TUP module sends a CFL message to the peer end. The service flow is shown in
the figure below.

18-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

18.2 Timer 208702


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T1

Timer Name

SS7_TIMER_TUP_ITUT_T1

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description 1

During a basic call flow, after SP A receives an IAM message carrying a continuity
indicator, if it does not receive the continuity signal or continuity fault signal within
10s~15s, it releases all devices and clears the connection.
The service flow is shown in the figure below.

18-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SP A SP B

IAM

COT
T1

CLF

RLG

1. SP A receives an IAM/IAI message carrying a continuity indicator, and


starts this timer.
2. If SP A has received a COT message before this timer expires, it stops
this timer.
3. If this timer expires, SP A releases the call.

Flow Description 2

During a basic call flow, after the TUP module at the outgoing side receives an
EV_L4L3_SETUP_IND message carrying a non-zero continuity indicator from the
GCM module, it starts this timer, and waits for an EV_L4L3_COTRESULT_IND
message. If this timer expires, the TUP module sends a CLF message to the peer
end, releasing the peer end before releasing L4.
The service flow is shown in the figure below.

18.3 Timer 208703


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T2
18-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

Timer Name

SS7_TIMER_TUP_ITUT_T2

Value Range

0~60000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description 1

During a basic call flow, if the call cannot be normally connected within 20s~60s
after SP A sends the last address message, SP A releases all devices and clears
the connection.
The service flow is shown in the figure below.
T2

1. After sending the last address message, SP A starts this timer.


2. If SP A has received an ACM message before this timer expires, it stops
this timer.
3. If this timer expires, SP A releases the call.

Flow Description 2

During a basic call flow, after sending a SetUpInd message, the TUP module at the
incoming side starts this timer. If the TUP module has not received an
EV_L4L3_ALERTING_IND message before this timer expires, it releases the call.
The service flow is shown in the figure below.

18-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

T2

18.4 Timer 208704


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T3

Timer Name

SS7_TIMER_TUP_ITUT_T3

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length


1ms

Flow Description

During a basic call flow, after SP B sends the status signal of the called MS
(indicating incomplete address, call congestion fault, or failing to complete the call),
if SP B cannot receive the incoming circuit clearing signal within 4s~15s, it should
send the call fault signal. The service flow is shown in the figure below.

18-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

1. SP B initiates a call release procedure. After sending the status signal of


the called MS (indicating incomplete address, call congestion fault, or
failing to complete the call), SP B starts this timer.
2. If SP B has received the forward clearing signal before this timer, it
stops this timer.
3. If this timer expires, SP B sends call fault signal.

18.5 Timer 208705


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T4

Timer Name

SS7_TIMER_TUP_ITUT_T4

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a basic call flow, after SP A sends the failure signal, if SP A cannot receive
the incoming circuit clearing signal within 5~60s, it should send the call fault signal.
The service flow is shown in the figure below.

18-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SP A SP B

CFL

CLF

CFL

1. After sending the call failure signal, SP A starts this timer.


2. If SP A has received a forward clearing signal before this timer expires, it
stops this timer.
3. If this timer expires, SP A sends the call fault signal, and restarts this
timer.

18.6 Timer 208706


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T5

Timer Name

SS7_TIMER_TUP_ITUT_T5

Value Range
0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

During a basic call flow, if SP A does not receive the forward clearing signal within
one minute after sending the fault signal of this call, SP A should stop resending the
call fault signal, and report alarms to the maintenance personnel.
The service flow is shown in the figure below.

18-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

1. After sending a CFL message, SP A starts this timer.


2. If SP A has received a CLF message before this timer expires, it stops
this timer.
3. If this timer expires, SP A stops sending the call failure message.

18.7 Timer 208707


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T6

Timer Name

SS7_TIMER_TUP_ITUT_T6

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

If SP A does not receive the release-guard signal responding to the clearing signal
within 4s~15s, it resends the clearing signal.
The service flow is shown in the figure below.

18-9

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. After sending a CLF message, SP A starts this timer.


2. If SP A has received a RLG message before this timer expires, it stops
this timer.
3. After this timer expires, SP A resends the forward clearing message,
and restarts this timer until it receives a RLG message or T7 expires.

18.8 Timer 208708


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T7

Timer Name

SS7_TIMER_TUP_ITUT_T7

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

If SP A does not receive the release-guard signal within one minute after sending
the first forward clearing signal, SP A should report alarms to the maintenance
personnel. SP A stops repeatedly sending the clearing signal, and sends the
blocking signal.
The service flow is shown in the figure below.

18-10

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

1. After sending the first CLF signal, SP A starts this timer.


2. If SP A has received a RLG message before this timer expires, it stops
this timer.
3. If SP A does not receive a RLG message within one minute, it stops
repeatedly sending the clearing signal.
4. SP A sends a RSC message to SP B.

18.9 Timer 208709


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T8

Timer Name

SS7_TIMER_TUP_ITUT_T8

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

If SP B does not receive the continuity result of the backward continuity tone within
15s, it is considered that the continuity check fails.
The service flow is shown in the figure below.

18-11

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

T8
1. After sending a continuity tone, SP B starts this timer.
2. If SP B has received a continuity result indicator before this timer
expires, it stops this timer.
3. If SP B has not received a continuity result indicator before this timer
expires, it is considered that the continuity check fails.

18.10 Timer 208710


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T12

Timer Name

SS7_TIMER_TUP_ITUT_T12

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

If an office does not receive the blocking acknowledgement signal 5s after sending
the single-circuit blocking signal, it resends the blocking signal.
The service flow is shown in the figure below.

18-12

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

SP A SP B

BLO

BLA

BLO

1. After sending a BLO message, SP A starts this timer.


2. If SP A has received a BLA message before this timer expires, it stops
this timer.
3. After this timer expires, SP A resends the BLO message, and restarts
this timer until T13 expires.

18.11 Timer 208711


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T13

Timer Name

SS7_TIMER_TUP_ITUT_T13

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

After sending the first BLO message, SP A starts this timer. If SP A does not
receive the blocking acknowledgement message one minute later, it should report
alarms to the maintenance personnel. The interval of resending BLO messages is
one minute.
The service flow is shown in the figure below.

18-13

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. When starting T12, SP A starts this timer.


2. If SP A has received a BLA message before this timer expires, it stops
this timer.
3. After this timer expires, SP A stops T12, starts T14, and resends a BLO
message.

18.12 Timer 208712


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T14

Timer Name

SS7_TIMER_TUP_ITUT_T14

Value Range
0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

If SP A does not receive the blocking acknowledgement message one minute after
sending the first blocking signal (T13), it should report alarms to the maintenance
personnel. The interval of resending the blocking signal or group blocking
messages is one minute (T14).
The service flow is shown in the figure below.

18-14

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

SP A SP B

BLO

BLA
T13

BLO
BLO
T14

BLO

1. After T13 expires, SP A starts this timer.


2. If SP A has received a BLA message before this timer expires, it stops
this timer.
3. After this timer expires, SP A resends a BLO message, and restarts this
timer. At the same time, the number of resent BLO messages increases.
SP A stops sending the BLO message until the number of resent BLO
messages reaches the maximum number supported by the system, and
stops this timer.

18.13 Timer 208713


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T15

Timer Name

SS7_TIMER_TUP_ITUT_T15

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

18-15

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Flow Description

If an office does not receive the unblocking acknowledgement signal 5s after


sending the single-circuit unblocking signal, it resends the unblocking signal.
The service flow is shown in the figure below.

1. After sending a UBL message, SP A starts this timer.


2. If SP A has received a UBA message before this timer expires, it stops
this timer.

18.14 Timer 208714


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T16

Timer Name
SS7_TIMER_TUP_ITUT_T16

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

18-16

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

If SP A does not receive the unblocking acknowledgement message one minute


after sending the first unblocking signal, it should report alarms to the maintenance
personnel. The interval of resending the unblocking signal is one minute.
The service flow is shown in the figure below.

1. After sending a UBL message, SP A starts this timer.


2. If SP A has received a UBA message before this timer expires, it stops
this timer.
3. After this timer expires, SP A stops T15, and starts T17.

18.15 Timer 208715


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T17

Timer Name

SS7_TIMER_TUP_ITUT_T17

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

If SP A does not receive the unblocking acknowledgement message one minute


after sending the first unblocking message (T16), it should report alarms to the
18-17

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

maintenance personnel. The interval of resending the unblocking signal is one


minute (T17).
The service flow is shown in the figure below.

SP A SP B

UBL

UBA
UBL
UBL

UBL

1. After T16 expires, SP A starts this timer.


2. If SP A has received a UBA message before this timer expires, it stops
this timer.
3. After this timer expires, SP A resends a UBL message, and restarts this
timer. At the same time, the number of resent UBL messages increases.
SP A stops sending the UBL message until the number of resent UBL
messages reaches the maximum number supported by the system, and
stops this timer.

18.16 Timer 208716


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T18

Timer Name

SS7_TIMER_TUP_ITUT_T18

Value Range

0~60000ms

Default Duration

5000ms

18-18

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

Adjustment Step Length

1ms

Flow Description

If an office does not receive the circuit reset acknowledgement signal 5s after
sending the single-circuit reset signal, it resends the single-circuit reset signal.
The service flow is shown in the figure below.

1. After sending a RSC message, SP A starts this timer.


2. If SP A has received a RLG message before this timer expires, it stops
this timer.
3. After this timer expires, SP A resends a RSC message, and restarts this
timer.

18.17 Timer 208717


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T19

Timer Name

SS7_TIMER_TUP_ITUT_T19

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

18-19

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1ms

Flow Description

If SP A does not receive the acknowledgment message within one minute after
resending the first reset message, SP A should report alarms to the maintenance
personnel.
The service flow is shown in the figure below.

1. After sending a RSC message, SP A starts T19.


2. If SP A receives a RLG message before T19 expires, it stops T19.
3. On the first expiry of T19, SP A stops T18, resends a RSC message,
and restarts T19. The number of resent RSC messages increases. SP A
stops sending the RSC message until the number of resent RSC
messages reaches the maximum number (4) supported by the system,
and stops T19.

18.18 Timer 208718


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T20

Timer Name

SS7_TIMER_TUP_ITUT_T20

Value Range

0~60000ms

Default Duration

5000ms

18-20

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

Adjustment Step Length

1ms

Flow Description

The circuit-group reset flow over TUP is shown in the figure below.

1. After receiving the first circuit-group reset message, SP B starts this


timer.
2. If SP B has received another circuit-group reset message before this
timer expires, the processing flow of the circuit-group reset operation is
triggered, and SP B stops this timer.
3. After this timer expires, SP B clears the status of waiting for the second
circuit-group reset message, performs no circuit-group reset operation,
and stops this timer.

18.19 Timer 208719


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T21

Timer Name

SS7_TIMER_TUP_ITUT_T21

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

18-21

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1ms

Flow Description

During a circuit-group reset flow, if SP A does not receive the circuit-group reset
acknowledgement (GRA) message 5s after sending the circuit-group reset message,
it resends the circuit-group reset message.
The service flow is shown in the figure below.

1. After sending two GRS messages, SP A starts this timer.


2. If SP A has received a GRA message before this timer expires, it stops
this timer.
3. After this timer expires, SP A sends two RSC messages again, and
restarts this timer.

18.20 Timer 208720


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T22

Timer Name

SS7_TIMER_TUP_ITUT_T22

Value Range

0~120000ms

Default Duration

60000ms

18-22

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

Adjustment Step Length

1ms

Flow Description

During a circuit-group reset flow, if SP A does not receive the circuit-group reset
acknowledgement (GRA) message one minute after sending the first circuit-group
reset message, it should report alarms to the maintenance personnel. Then SP A
sends a circuit-group reset message every one minute until it receives ab
acknowledgement message.
The service flow is shown in the figure below.

1. After sending two GRS messages at the first time, SP A starts T22.
2. If SP A receives a GRA message before T22 expires, it stops T22.
3. On the first expiry of T22, SP A stops T21, sends two GRS messages
again, and restarts T22. The number of resent GRS messages
increases.
4. On the second expiry of T22, SP A sends two GRS messages again,
and restarts T22. The number of resent GRS messages increases. SP A
stops sending the GRS message until the number of resent GRS
messages reaches the maximum number supported by the system.

18.21 Timer 208721


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T23

Timer Name

SS7_TIMER_TUP_ITUT_T23

Value Range
18-23

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group maintenance-blocking flow over TUP, if SP B receives two


circuit-group blocking messages within 5s, the circuit-group maintenance-blocking
flow is triggered.
The service flow is shown in the figure below.

1. After receiving the first MGB message, SP B starts this timer.


2. If SP B has received a second MGB message before this timer expires,
SP B stops this timer, and enters the circuit-group blocking operation
flow.
3. After this timer expires, SP B clears the status of waiting for the second
MGB message, and performs no circuit-group blocking operation.

18.22 Timer 208722


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T24

Timer Name

SS7_TIMER_TUP_ITUT_T24

Value Range
18-24

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group maintenance-unblocking flow over TUP, if SP B receives two


circuit-group blocking messages within 5s, the circuit-group
maintenance-unblocking flow is triggered.
The service flow is shown in the figure below.

1. After receiving the first MGU message, SP B starts this timer.


2. If SP B has received the second MGU message before this timer
expires, SP B stops this timer, and enters the circuit-group
maintenance-unblocking operation flow.
3. After this timer expires, SP B clears the status of waiting for the second
MGU message, and performs no circuit-group maintenance-unblocking
operation.

18.23 Timer 208723


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T26

Timer Name

SS7_TIMER_TUP_ITUT_T26

18-25

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group maintenance-blocking flow, if an office does not receive the


circuit-group maintenance-blocking acknowledgement message 5s after sending a
circuit-group maintenance-blocking message, it resends the circuit-group
maintenance-blocking message.
The service flow is shown in the figure below.

1. After sending two MGB messages, SP A starts this timer.


2. If SP A has received a MGA message before this timer expires, it stops
this timer.
3. After this timer expires, SP A sends two MGB messages again, and
restarts this timer.

18.24 Timer 208724


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T27

18-26

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

Timer Name

SS7_TIMER_TUP_ITUT_T27

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group maintenance-blocking flow, if an office does not receive the


circuit-group maintenance-blocking acknowledgement message one minute after
sending a circuit-group maintenance-blocking message, it should report alarms to
the maintenance personnel. The interval of resending circuit-group
maintenance-blocking messages is one minute.
The service flow is shown in the figure below.

1. After sending two MGB messages, SP A starts this timer.


2. If SP A has received a MGA message before this timer expires, it stops
this timer.
3. On the first expiry of T27, SP A stops T26, sends two MGB messages
again, and restarts T27. The number of resent MGB messages
increases.
4. On the second expiry of T27, SP A sends two MGB messages again,
and restarts T27. The number of resent MGB messages increases by
one. SP A stops sending MGB messages until the number of resent

18-27

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

MGB messages reaches the maximum number (4) supported by the


system.

18.25 Timer 208725


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T28

Timer Name

SS7_TIMER_TUP_ITUT_T28

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group maintenance-unblocking flow, if an office does not receive the


circuit-group maintenance-unblocking acknowledgement message 5s after sending
a circuit-group maintenance-unblocking message, it resends the circuit-group
maintenance-unblocking message.
The service flow is shown in the figure below.
T28

1. After sending two MGU messages, SP A starts this timer.

18-28

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

2. If SP A has received a MUA message before this timer expires, it stops


this timer.
3. After this timer expires, SP A sends two MGU messages again, and
restarts this timer.

18.26 Timer 208726


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T29

Timer Name

SS7_TIMER_TUP_ITUT_T29

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group maintenance-unblocking flow, if an office does not receive the


circuit-group maintenance-unblocking acknowledgement message one minute after
sending a circuit-group maintenance-unblocking message, it should report alarms to
the maintenance personnel. The interval of resending circuit-group
maintenance-unblocking messages is one minute.
The service flow is shown in the figure below.

18-29

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. After sending two MGU messages, SP A starts this timer.


2. If SP A has received a MUA message before this timer expires, it stops
this timer.
3. On the first expiry of T29, SP A stops T28, sends two MGU messages
again, and restarts T29. The number of resent MGU messages
increases by one.
4. On the second expiry of T29, SP A sends two MGU messages again,
and restarts T29. The number of resent MGU messages increases. SP A
stops sending MGU messages and stops T29 until the number of resent
MGU messages reaches the maximum number (4) supported by the
system.

18.27 Timer 208727


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T30

Timer Name

SS7_TIMER_TUP_ITUT_T30

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group hardware-blocking flow, if SP B receives two circuit-group


hardware-blocking messages within 5s, the proper measures are performed.
The service flow is shown in the figure below.

18-30

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

1. After receiving the first HGB message, SP B starts this timer.


2. If SP B has received the second HGB message before this timer expires,
SP B stops this timer, and enters the circuit-group hardware-blocking
operation flow.
3. After this timer expires, SP B clears the status of waiting for the second
HGB message, and performs no circuit-group hardware-blocking
operation.

18.28 Timer 208728


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T31

Timer Name

SS7_TIMER_TUP_ITUT_T31

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group hardware-unblocking flow, if SP B receives two circuit-group


hardware-unblocking messages within 5s, the proper measures are performed.
The service flow is shown in the figure below.

18-31

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. After receiving the first HGU message, SP B starts this timer.


2. If SP B has received the second HGU message before this timer expires,
SP B stops this timer, and enters the circuit-group hardware-unblocking
operation flow.
3. After this timer expires, SP B clears the status of waiting for the second
HGU message, and performs no circuit-group hardware-unblocking
operation.

18.29 Timer 208729


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T32

Timer Name

SS7_TIMER_TUP_ITUT_T32

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group hardware-blocking flow, if an office does not receive the


circuit-group hardware-blocking acknowledgement message 5s after sending a

18-32

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

circuit-group hardware-blocking message, it resends the circuit-group


hardware-blocking message.
The service flow is shown in the figure below.

SP A SP B
HGB
HGB

HBA
T32

HGB

HGB

1. After sending two HGB messages, SP A starts this timer.


2. If SP A has received a HBA message before this timer expires, it stops
this timer.
3. After this timer expires, SP A sends two HGB messages again, and
restarts this timer.

18.30 Timer 208730


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T33

Timer Name

SS7_TIMER_TUP_ITUT_T33

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

18-33

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

During a circuit-group hardware-blocking flow, if an office does not receive the


circuit-group hardware-blocking acknowledgement message one minute after
sending a circuit-group hardware-blocking message, it should report alarms to the
maintenance personnel. The interval of resending circuit-group hardware-blocking
messages is one minute.
The service flow is shown in the figure below.

1. After sending two HGB messages, SP A starts this timer.


2. If SP A has received a HBA message before this timer expires, it stops
this timer.
3. On the first expiry of T33, SP A stops T32, sends two HGB messages
again, and restarts T33. The number of resent HGB messages
increases by one.
4. On the second expiry of T33, SP A sends two HGB messages again,
and restarts T33. The number of resent HGB messages increases by
one. SP A stops sending HGB messages and stops T33 until the
number of resent HGB messages reaches the maximum number (4)
supported by the system.

18.31 Timer 208731


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T34

Timer Name

SS7_TIMER_TUP_ITUT_T34

Value Range

0~60000ms

18-34

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group hardware-unblocking flow, if an office does not receive the


circuit-group hardware-unblocking acknowledgement message 5s after sending a
circuit-group hardware-unblocking message, it resends the circuit-group
hardware-unblocking message.
The service flow is shown in the figure below.

SP A SP B
HGU
HGU

HUA
T34

HGU
HGU

1. After sending two HGU messages, SP A starts this timer.


2. If SP A has received a HUA message before this timer expires, it stops
this timer.
3. After this timer expires, SP A sends two HGU messages again, and
restarts this timer.

18.32 Timer 208732


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T35

Timer Name

SS7_TIMER_TUP_ITUT_T35

Value Range

18-35

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

During a circuit-group hardware-unblocking flow, if an office does not receive the


circuit-group hardware-unblocking acknowledgement message one minute after
sending a circuit-group hardware-unblocking message, it should report alarms to
the maintenance personnel. The interval of resending circuit-group
hardware-unblocking messages is one minute.
The service flow is shown in the figure below.

1. After sending two HGU messages, SP A starts this timer.


2. If SP A has received a HUA message before this timer expires, it stops
this timer.
3. On the first expiry of T35, SP A stops T34, sends two HGU messages
again, and restarts T35. The number of resent HGU messages
increases by one.
4. On the second expiry of T35, SP A sends two HGU messages again,
and restarts T35. The number of resent HGU messages increases by
one. SP A stops sending HGU messages and stops T35 until the
number of resent HGU messages reaches the maximum number (4)
supported by the system.

18-36

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

18.33 Timer 208733


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T52

Timer Name

SS7_TIMER_TUP_ITUT_T52

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During a basic incoming call flow, after the TUP module sends an L3L4SetUpInd
message to the GCM module, it starts this timer, and waits for an L4L3SetUpAck
message from the GCM module. If this timer expires, the TUP module releases the
call (releasing L3 before releasing L4).
This timer is for interaction between internal modules. The service flow is as follows:
1. During an incoming call, after the TUP module receives an IAM
message, it correctly decodes the message, and sends an
L3L4SetUpInd message to the GCM module. Then the TUP module
starts this timer.
2. If the TUP module has received an L4L3SetUpAck message before this
timer expires, it stops this timer.
3. If this timer expires, the TUP module releases the call.

18.34 Timer 208734


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T53

Timer Name

SS7_TIMER_TUP_ITUT_T53

Value Range

18-37

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present.

18.35 Timer 208735


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T54

Timer Name

SS7_TIMER_TUP_ITUT_T54

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

During a basic call flow, after the TUP module receives a REL message, it sends an
L3L4ReleaseInd message to the GCM module. Then it starts this timer, and waits
for an L4L3ReleaseAck message from the GCM module. If this timer expires, the
TUP module releases the call.
This timer is for interaction between internal modules. The service flow is as follows:
1. After the TUP module receives a REL message, it correctly decodes the
message. Then the TUP module starts this timer, and waits for a
processing response message from the call processing module.
2. If the TUP module has received an L4L3ReleaseAck message before
this timer expires, it stops this timer, and encodes the RLC message.

18-38

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

3. If this timer expires, and if the TUP module is in the dual-seizure status,
it releases this call, and then encodes the RLC message and notifies the
peer end.

18.36 Timer 208736


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T55

Timer Name

SS7_TIMER_TUP_ITUT_T55

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

During a basic call flow, after the TUP module receives an L4L3AlertingInd
message, it starts this timer, and waits for an L4L3AnswerInd message from the
GCM module. If this timer expires, the TUP module releases the call.
This timer is for interaction between internal modules. The service flow is shown in
the figure below.

18-39

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. After receiving an L4L3AlertingInd message, the TUP module starts this


timer, and waits for an L4L3AnswerInd message.
2. If the TUP module has received an L4L3AnswerInd message before this
timer expires, it stops this timer.
3. If this timer expires, the TUP module releases the call.

18.37 Timer 208737


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T56

Timer Name

SS7_TIMER_TUP_ITUT_T56

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present.

18.38 Timer 208738


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T58

Timer Name

SS7_TIMER_TUP_ITUT_T58

Value Range

0~240000ms

Default Duration

120000ms
18-40

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

Adjustment Step Length

1ms

Flow Description

This timer is not used at present.

18.39 Timer 208739


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T62

Timer Name

SS7_TIMER_TUP_ITUT_T62

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present. LPA is only used in ANSI.

18.40 Timer 208740


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T63

Timer Name

SS7_TIMER_TUP_ITUT_T63

Value Range

0~240000ms

Default Duration

18-41

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer for waiting for the answer from the called party during
a national toll call. The service flow is shown in the figure below.

1. SP A originates a call by sending an IAM message to SP B. The IAM


message indicates that this call is a national toll call.
2. After SP A receives an ACM message or the ringing indicator from the
called party, it starts this timer, and waits for an ANM message from SP
B.
3. If SP A has received an ANM message or the answer indicator from the
called party before this timer expires, it stops this timer.
4. The subsequent steps are the same with those in the message release
flow after the call.

18.41 Timer 208741


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T64

Timer Name

SS7_TIMER_TUP_ITUT_T64

Value Range

18-42

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer for waiting for the answer from the called party during
an international toll call. The service flow is shown in the figure below.

1. SP A originates a call by sending an IAM message to SP B. The IAM


message indicates that this call is an international toll call.
2. After SP A receives an ACM message or the ringing indicator from the
called party, it starts this timer, and waits for an ANM message from SP
B.
3. If SP A has received an ANM message or the answer indicator from the
called party before this timer expires, it stops this timer.
4. The subsequent steps are the same with those in the message release
flow after the call.

18.42 Timer 208742


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T66

Timer Name

18-43

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SS7_TIMER_TUP_ITUT_T66

Value Range

0~240000ms

Default Duration

90000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer used in the call suspension flow. The service flow is
shown in the figure below.

1. During an outgoing call, after SP A receives a CKB message, it starts


this timer, and waits for a suspension restoration message.
2. If SP A has received a RAN message before this timer expires, it stops
this timer.
3. If this timer expires, SP A initiates call release by sending a CLF
message.

18.43 Timer 208743


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T68

Timer Name

18-44

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

SS7_TIMER_TUP_ITUT_T68

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

After receiving a GetTpCicAck message from the DB, the local office sends an
L3L4TpCallInd message to the GCM module. Then it starts this timer, and waits for
an L4L3TpCallAck message. If this timer expires, the local office directly releases
the call.

18.44 Timer 208744


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T69

Timer Name

SS7_TIMER_TUP_ITUT_T69

Value Range

18-45

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

After receiving a GetTpCicAck message from the DB, the local office sends an
L3L4TpCallInd message to the GCM module. Then it starts this timer, and waits for
an L4L3SetUpInd message. If this timer expires, the local office directly releases the
call.

18.45 Timer 208745


Macro Name of Timer

SS7_TIMER_TUP_ITUT_T70

Timer Name

SS7_TIMER_TUP_ITUT_T70

Value Range

0~120000ms

Default Duration

18-46

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 18 Timers Related with TUP Module (ITU Protocol)

70000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

SS7UP SS7UP

COT

CCR

RSC
RLG

After receiving a COT (continuity failure) message from the peer end, the local
office starts this timer, and waits for a CCR (re-continuity) message. If this timer
expires, the local office sends a RSC (reset) message to the peer end, and releases
the circuit.

18-47

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


18-48

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter19
Timers Related with TUP
Module (CHINA Protocol)
———————————————————————————————————————————

19.1 Timer 208751


Macro Name of Timer

SS7_TIMER_TUP_CN_T0

Timer Name

SS7_TIMER_TUP_CN_T0

Value Range

0~240000ms

Default Duration
120000ms

Adjustment Step Length

1ms

Flow Description 1

After the TUP module receives an EV_L4L3_ALERTING_IND message from the


GCM module, and the “(Incoming) Send UNN When TUP Play Blank Tone” trunk
switch is opened, the TUP module sends an UNN message to the peer end. Then it
starts this timer, and waits for an EV_L4L3_ANSWER_IND message. If this timer
expires, the TUP module sends a CFL message to the L3 module.
The service flow is shown in the figure below.

19-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

TUP GCM

EV_L4L3_ALERTING_IND
UNN

EV_L4L3_ANSWER_IND

CFL

Flow Description 2

After receiving an EV_L4L3_ALERTING_IND message from the GCM module, the


TUP module sends an ACM message to the peer end. Then it starts this timer, and
waits for an EV_L4L3_ANSWER_IND message. If this timer expires, the TUP
module sends a CFL message to the L3 module. The service flow is shown in the
figure below.

TUP GCM

EV_L4L3_ALERTING_IND
ACM
T0

EV_L4L3_ANSWER_IND

CFL

Flow Description 3

After receiving an ACM message from the peer end, the TUP module starts this
timer, and waits for an ANM message from the peer end. If this timer expires, the
19-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

TUP module sends a CFL message to the peer end. The service flow is shown in
the figure below.

T0

19.2 Timer 208752


Macro Name of Timer

SS7_TIMER_TUP_CN_T1

Timer Name

SS7_TIMER_TUP_CN_T1

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description 1

During a basic call flow, after SP A receives an IAM message carrying a continuity
indicator, if it has not received the continuity signal or continuity fault signal within
10s~15s, it releases all devices and clears the connection.
19-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

The service flow is shown in the figure below.


T1

1. SP A receives an IAM/IAI message carrying a continuity indicator, and


starts this timer.
2. If SP A has received a COT message before this timer expires, it stops
this timer.
3. If this timer expires, SP A releases the call.

Flow Description 2

During a basic call flow, after the TUP module at the outgoing side receives an
EV_L4L3_SETUP_IND message carrying a non-zero continuity indicator from the
GCM module, it starts this timer, and waits for an EV_L4L3_COTRESULT_IND
message. If this timer expires, the TUP module sends a CLF message to the peer
end, releasing the peer end before releasing L4.
The service flow is shown in the figure below.

19-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

T1
19.3 Timer 208753
Macro Name of Timer

SS7_TIMER_TUP_CN_T2

Timer Name

SS7_TIMER_TUP_CN_T2

Value Range

0~60000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description 1

During a basic call flow, if the call cannot be normally connected within 20s~60s
after SP A sends the last address message, SP A releases all devices and clears
the connection.
The service flow is shown in the figure below.

19-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SP A SP B

IAI/IAM

ACM

CLF

RLG

1. After sending the last address message, SP A starts this timer.


2. If SP A has received an ACM message before this timer expires, it stops
this timer.
3. If this timer expires, SP A releases the call.

Flow Description 2

During a basic call flow, after sending a SetUpInd message, the TUP module at the
incoming side starts this timer. If the TUP module has not received an
EV_L4L3_ALERTING_IND message before this timer expires, it releases the call.
The service flow is shown in the figure below.

TUP GCM
IAI/IAM
EV_L3L4_SETUP_IND

EV_L4L3_ALERTING_IND
CFL

RLG

19.4 Timer 208754


Macro Name of Timer

19-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

SS7_TIMER_TUP_CN_T3

Timer Name

SS7_TIMER_TUP_CN_T3

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a basic call flow,after SP B sends the status signal of the called MS
(indicating incomplete address, call congestion fault, or failing to complete the call),
if SP B can not receive the incoming circuit clearing signal within 4s~15s, it should
send the call fault signal.
The service flow is shown in the figure below.

SP A SP B

ADI

CLF

CFL

1. SP A initiates a call release procedure. After sending the status signal of


the called MS (indicating incomplete address, call congestion fault, or
failing to complete the call), SP A starts this timer.
2. If SP B has received the forward clearing signal before this timer, it
stops this timer.
3. If this timer expires, SP B sends the call fault signal.

19-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

19.5 Timer 208755


Macro Name of Timer

SS7_TIMER_TUP_CN_T4

Timer Name

SS7_TIMER_TUP_CN_T4

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

During a basic call flow, after SP A sends the failure signal, if SP A cannot receive
the incoming circuit clearing signal within 5~60s, it should send the call fault signal.
The service flow is shown in the figure below.
T4

1. After sending the call failure signal, SP A starts this timer.


2. If SP A has received the forward clearing signal before this timer expires,
it stops this timer.
3. If this timer expires, SP A sends the call fault signal, and restarts this
timer.

19-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

19.6 Timer 208756


Macro Name of Timer

SS7_TIMER_TUP_CN_T5

Timer Name

SS7_TIMER_TUP_CN_T5

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

During a basic call flow, if SP A does not receive the forward clearing signal within
one minute after sending the fault signal of this call, SP A should stop resending the
call fault signal, and reports alarms to the maintenance personnel.
The service flow is shown in the figure below.

SP A SP B

CFL

CFL
T5

CLF
CFL

1. After sending a CFL message, SP A starts this timer.


2. If SP A has received a CLF message before this timer expires, it stops
this timer.
3. If this timer expires, SP A stops sending the call failure message.

19-9

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

19.7 Timer 208757


Macro Name of Timer

SS7_TIMER_TUP_CN_T6

Timer Name

SS7_TIMER_TUP_CN_T6

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

If SP A does not receive the release-guard signal responding to the clearing signal
within 4s~15s, it resends the clearing signal.
The service flow is shown in the figure below.

SP A SP B

CLF
T6

RLG
CLF

1. After sending a CLF message, SP A starts this timer.


2. If SP A has received a RLG message before this timer expires, it stops
this timer.
3. After this timer expires, SP A resends the forward clearing message,
and restarts this timer until it receives a RLG message or T7 expires.

19-10

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

19.8 Timer 208758


Macro Name of Timer

SS7_TIMER_TUP_CN_T7

Timer Name

SS7_TIMER_TUP_CN_T7

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

If SP A does not receive the release-guard signal within one minute after sending
the first forward clearing signal, SP A should report alarms to the maintenance
personnel. SP A stops repeatedly sending the clearing signal, and sends the
blocking signal.
The service flow is shown in the figure below.

SP A SP B

CLF

RLG
T7

CLF

RSC

1. After sending the first CLF signal, SP A starts this timer.


2. If SP A has received a RLG message before this timer expires, it stops
this timer.

19-11

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

3. If SP A does not receive a RLG message within one minute, it stops


repeatedly sending the clearing signal.
4. SP A sends a RSC message to SP B.

19.9 Timer 208759


Macro Name of Timer

SS7_TIMER_TUP_CN_T8

Timer Name

SS7_TIMER_TUP_CN_T8

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

If SP B does not receive the continuity result of the backward continuity tone within
15s, it is considered that the continuity check fails.
The service flow is shown in the figure below.

SP A SP B

CCR
T8

CCR

CCF

1. After sending a continuity tone, the TUP module starts this timer.

19-12

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

2. If the TUP module has received the continuity result indicator before this
timer expires, it stops this timer.
3. If the TUP module has not received the continuity result indicator before
this timer expires, it is considered that the continuity check fails.

19.10 Timer 208760


Macro Name of Timer

SS7_TIMER_TUP_CN_T52

Timer Name

SS7_TIMER_TUP_CN_T52

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is for interaction between internal modules. The service flow is as follows:
1. During an incoming call, after the TUP module receives an IAM
message, it correctly decodes it, and sends an L3L4SetUpInd message
to the GCM module. Then the TUP module starts this timer.
2. If the TUP module has received an L4L3SetUpAck message before this
timer expires, it stops this timer.
3. If this timer expires, the TUP module releases the call (releasing L3
before releasing L4).

19.11 Timer 208761


Macro Name of Timer

SS7_TIMER_TUP_CN_T53

Timer Name

19-13

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SS7_TIMER_TUP_CN_T53

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present.

19.12 Timer 208762


Macro Name of Timer

SS7_TIMER_TUP_CN_T54

Timer Name

SS7_TIMER_TUP_CN_T54

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is for interaction between internal modules. The service flow is as follows:
1. After receiving a REL message, the TUP module sends an
L3L4ReleaseInd message to the GCM module. Then the TUP module
starts this timer, and waits for a processing response message from the
GCM module.

19-14

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

2. If the TUP module has received an L4L3ReleaseAck message before


this timer expires, it stops this timer, and encodes the RLC message.
3. If this timer expires, and if the TUP module is in the dual-seizure status,
it releases this call, and then encodes the RLC message and notifies the
peer end.

19.13 Timer 208763


Macro Name of Timer

SS7_TIMER_TUP_CN_T55

Timer Name

SS7_TIMER_TUP_CN_T55

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

During a basic call flow, after the TUP module receives an L4L3AlertingInd message,
it starts this timer, and waits for an L4L3AnswerInd message from the GCM module.
If this timer expires, the TUP module releases the call.
This timer is for interaction between internal modules. The service flow is shown in
the figure below.

19-15

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SS7UP GCM

L4L3AlertingInd

L4L3AnswerInd

REL
RLC
L3L4ReleaseInd

L4L3ReleaseAck

1. After receiving an L4L3AlertingInd message, the TUP module starts this


timer, and waits for an L4L3AnswerInd message.
2. If the TUP module has received an L4L3AnswerInd message before this
timer expires, it stops this timer.
3. If this timer expires, the TUP module releases the call.

19.14 Timer 208764


Macro Name of Timer

SS7_TIMER_TUP_CN_T56

Timer Name

SS7_TIMER_TUP_CN_T56

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

19-16

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

This timer is not used at present.

19.15 Timer 208765


Macro Name of Timer

SS7_TIMER_TUP_CN_T58

Timer Name

SS7_TIMER_TUP_CN_T58

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present.

19.16 Timer 208766


Macro Name of Timer

SS7_TIMER_TUP_CN_T62

Timer Name

SS7_TIMER_TUP_CN_T62

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

19-17

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1ms

Flow Description

This timer is not used at present. LPA is only used in ANSI.

19.17 Timer 208767


Macro Name of Timer

SS7_TIMER_TUP_CN_T63

Timer Name

SS7_TIMER_TUP_CN_T63

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer used when waiting for the answer from the called
party during a national toll call. The service flow is shown in the figure below.

SP A SP B

IAM(national\international call indicator=0)

ACM
T63

ANM

REL

RLC

19-18

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

1. SP A originates a call by sending an IAM message to SP B. The IAM


message indicates that this call is a national toll call.
2. After SP A receives an ACM message or the ringing indication from the
called party, it starts this timer, and waits for an ANM message from SP
B.
3. If SP A has received an ANM message or the answer indicator from the
called party before this timer expires, it stops this timer.
4. The subsequent steps are the same with those in the message release
flow after the call.

19.18 Timer 208768


Macro Name of Timer

SS7_TIMER_TUP_CN_T64

Timer Name

SS7_TIMER_TUP_CN_T64

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer used when waiting for the answer from the called
party during an international toll call. The service flow is shown in the figure below.

19-19

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SP A SP B

IAM(national\international call indicator=1)

ACM
T64

ANM

CLF

RLG

1. SP A originates a call by sending an IAM message to SP B. The IAM


message indicates that this call is an international toll call.
2. After SP A receives an ACM message or the ringing indication from the
called party, it starts this timer, and waits for an ANM message from SP
B.
3. If SP A has received an ANM message or the answer indicator from the
called party before this timer expires, it stops this timer.
4. The subsequent steps are the same with those in the message release
flow after the call.

19.19 Timer 208769


Macro Name of Timer

SS7_TIMER_TUP_CN_T66

Timer Name

SS7_TIMER_TUP_CN_T66

Value Range

0~240000ms

Default Duration

90000ms

Adjustment Step Length

1ms

19-20

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

Flow Description

This timer is an internal timer used in the call suspension flow. The service flow is
shown in the figure below.

SP A SP B

CBK

RAN
T64

REL

RLC

1. During an outgoing call, after SP A receives a CKB message, it starts


this timer, and waits for a suspension restoration message.
2. If SP A has received a RAN message before this timer expires, it stops
this timer.
3. If this timer expires, SP A initiates call release by sending a CLF
message.

19.20 Timer 208770


Macro Name of Timer

SS7_TIMER_TUP_CN_T68

Timer Name

SS7_TIMER_TUP_CN_T68

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

19-21

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1ms

Flow Description

The service flow is shown in the figure below.

GCM SS7UP
GetTpCicAck
L3L4TpCallInd

T68
L4L3TpCallAck
CLF
RLG
L3L4ReleaseInd
L4L3ReleaseAck

After receiving a GetTpCicAck message from the DB, the local office sends an
L3L4TpCallInd message to the GCM module. Then it starts this timer, and waits for
an L4L3TpCallAck message. If this timer expires, the local office directly releases
the call.

19.21 Timer 208771


Macro Name of Timer

SS7_TIMER_TUP_CN_T69

Timer Name

SS7_TIMER_TUP_CN_T69

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

19-22

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 19 Timers Related with TUP Module (CHINA Protocol)

Flow Description

The service flow is shown in the figure below.

GCM SS7UP
GetTpCicAck
L3L4TpCallInd

L4L3TpCallAck

T69
L4L3SetUpInd
CLF
RLG
L3L4ReleaseInd
L4L3ReleaseAck

After receiving a GetTpCicAck message from the DB, the local office sends an
L3L4TpCallInd message to the GCM module. Then it starts this timer, and waits for
an L4L3SetUpInd message. If this timer expires, the local office directly releases the
call.

19.22 Timer 208772


Macro Name of Timer

SS7_TIMER_TUP_CN_T70

Timer Name

SS7_TIMER_TUP_CN_T70

Value Range

0~120000ms

Default Duration

70000ms

Adjustment Step Length

1ms

Flow Description

19-23

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

The service flow is shown in the figure below.

T70
After receiving a COT (continuity failure) message from the peer end, the local office
starts this timer, and waits for a CCR (re-continuity) message. If this timer expires,
the local office sends a RSC (reset) message to the peer end, and releases the
circuit.

19-24

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter20
Timers Related with ISUP
Module (ITU Protocol)
———————————————————————————————————————————

20.1 Timer 208781


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T1

Timer Name

SS7_TIMER_ISUP_ITUT_T1

Value Range

0~60000ms

Default Duration
15000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

20-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. SP B originates s a call to SP A by sending an IAM message to SP A.


2. After receiving the IAM message, SP A returns an ACM (address
completion) message to SP B.
3. SP A returns an ANM message to SP B.
4. SP A clears this call by sending a REL message. Then it starts this timer.
After this timer expires, SP A continues to send REL messages.

20.2 Timer 208782


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T5

Timer Name

SS7_TIMER_ISUP_ITUT_T5

Value Range

0~900000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

This timer is used for the clearing phase. After the ISUP module sends a REL
message, it starts this timer, and waits for a RLC message from the peer end.
20-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

The service flow is shown in the figure below.

1. SP B originates s a call to SP A by sending an IAM message to SP A.


2. After receiving the IAM message, SP A returns an ACM (address
completion) message to SP B.
3. SP A returns an ANM message to SP B.
4. SP A clears this call by sending a REL message. Then it starts this timer,
and waits for a RLC message from the peer end.
5. After this timer expires, SP A sends a RSCL message.

20.3 Timer 208783


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T6

Timer Name

SS7_TIMER_ISUP_ITUT_T6

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

20-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1ms

Flow Description

The service flow is shown in the figure below.

After receiving an SUS message, SP A starts this timer, and waits for a RES
(restoration) message.

20.4 Timer 208784


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T7

Timer Name

SS7_TIMER_ISUP_ITUT_T7

Value Range

0~60000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description 1

This timer specifies the duration of waiting for the ACM message after sending the
address. If SP A has not received an ACM message before this timer expires, it
releases the circuit.
The service flow is shown in the figure below.

20-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

1. SP A originates s a call to SP B by sending an IAM or SAM message to


SP B (not shown in the above figure).
2. After sending the address, SP A starts this timer, and waits for an ACM
message from SP B.
3. After SP A receives an ACM message from SP B, it stops this timer.
4. The subsequent steps are the same with those of the basic call flow.

Flow Description 2

During a basic call flow, after sending a SetUpInd message, the ISUP module at the
incoming side starts this timer. If the ISUP module has not received an
EV_L4L3_ALERTING_IND message before this timer expires, it releases the call.
The service flow is shown in the figure below.

20.5 Timer 208785


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T8

Timer Name
20-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SS7_TIMER_ISUP_ITUT_T8

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description 1

When the IAM message indicates that a continuity check is required or that the
continuity check should be performed at the front end, SP A starts this timer, and
waits for a COT message.
The service flow is shown in the figure below.

1. SP B originates s a call to SP A by sending an IAM message to SP A.


2. After SP A receives the IAM message indicating that a continuity check
is required to be performed at the local end or the front end, it starts this
timer, and waits for a COT message.
3. After receiving the COT message, SP A stops this timer.
4. The subsequent steps are the same with those of the basic call flow.

Flow Description 2

During a basic call flow, after the ISUP module at the outgoing side receives an
EV_L4L3_SETUP_IND message carrying a non-zero continuity indicator from the
GCM module, it starts this timer, and waits for an EV_L4L3_COTRESULT_IND
message. If this timer expires, the ISUP module sends a REL message to the peer
end, releasing the peer end before releasing L4.
20-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

The service flow is shown in the figure below.

20.6 Timer 208786


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T9

Timer Name

SS7_TIMER_ISUP_ITUT_T9

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description 1

After receiving an EV_L4L3_ALERTING_IND message from the GCM module, the


ISUP module sends an ACM message to the peer end. Then it starts this timer, and
waits for an EV_L4L3_ANSWER_IND message. If this timer expires, the ISUP
module sends a REL message to the L3 module. The service flow is shown in the
figure below.

20-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

T9

Flow Description 2

After receiving an ACM message from the peer end, the ISUP module starts this
timer, and waits for an ANM message from the peer end. If this timer expires, the
ISUP module sends a REL message to the peer end.
The service flow is shown in the figure below.

20.7 Timer 208787


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T12

Timer Name

SS7_TIMER_ISUP_ITUT_T12
20-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

After sending a BLO message, SP A starts T12, and waits for a BLA message from
SP B. If SP B does not return a BLA message, SP A sends BLO messages all the
while, and stops T12 until T13 expires.
The service flow is shown in the figure below.

SPA SPB

BLO

BLA

20.8 Timer 208788


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T13

Timer Name

SS7_TIMER_ISUP_ITUT_T13

Value Range

0~600000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

20-9

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

After sending a BLO message, SP A starts T13, and waits for a BLA message from
SP B. On the first expiry of T13, SP A resends a BLO message, and restarts T13.
The number of resent BLO messages increases by one. On the second expiry of
T13, SP A resends a BLO message again, and restarts T13. The number of resent
BLO messages increases by one. SP A stops sending BLO messages and stops
T13 until the number of resent BLO messages reaches the maximum number (2)
supported by the system.
The service flow is shown in the figure below.

20.9 Timer 208789


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T14

Timer Name

SS7_TIMER_ISUP_ITUT_T14

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

After sending a UBL message, SP A starts T14, and waits for a UBA message from
SP B. If SP B does not return a UBA message, SP A sends UBL messages all the
while, and stops T14 until T15 expires.
The service flow is shown in the figure below.

20-10

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

20.10 Timer 208790


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T15

Timer Name

SS7_TIMER_ISUP_ITUT_T15

Value Range

0~600000ms

Default Duration

300000ms

Adjustment Step Length


1ms

Flow Description

After sending a UBL message, SP A starts T15, and waits for a UBA message from
SP B. On the first expiry of T15, SP A resends a UBL message, and restarts T13.
The number of resent UBL messages increases by one. On the second expiry of
T15, SP A resends a UBL message again, and restarts T15. The number of resent
UBL messages increases by one. SP A stops sending UBL messages and stops
T15 until the number of resent UBL messages reaches the maximum number (2)
supported by the system.
The service flow is shown in the figure below.

20-11

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

20.11 Timer 208791


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T16

Timer Name

SS7_TIMER_ISUP_ITUT_T16

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length


1ms

Flow Description

After sending a RSC (circuit reset) message, SP A starts this timer, and waits for a
REL message from SP B.
The service flow is shown in the figure below.

20-12

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

20.12 Timer 208792


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T17

Timer Name

SS7_TIMER_ISUP_ITUT_T17

Value Range

0~600000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

After sending a RSC message, SP A starts T17, and waits for a REL message from
SP B. On the first expiry of T17, SP A resends a RSC message, and restarts T17.
The number of resent RSC messages increases by one. On the second expiry of
T17, SP A resends a RSC message again, and restarts T17. The number of resent
RSC messages increases by one. SP A stops sending RSC messages and stops
T17 until the number of resent RSC messages reaches the maximum number (2)
supported by the system.
The service flow is shown in the figure below.

20.13 Timer 208793


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T18

Timer Name

20-13

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SS7_TIMER_ISUP_ITUT_T18

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

After sending a CGB message, SP A starts T18, and waits for a CGBA message
from SP B.
The service flow is shown in the figure below.

20.14 Timer 208794


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T19

Timer Name

SS7_TIMER_ISUP_ITUT_T19

Value Range

0~600000ms

Default Duration

300000ms

Adjustment Step Length

1ms

20-14

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

Flow Description

After sending a CGB message, SP A starts T19, and waits for a CGBA message
from SP B. On the first expiry of T19, SP A resends a CGB message, and restarts
T19. The number of resent CGB messages increases by one. On the second expiry
of T19, SP A resends a CGB message again, and restarts T19. The number of
resent CGB messages increases by one. SP A stops sending CGB messages and
stops T19 until the number of resent CGB messages reaches the maximum number
(2) supported by the system.
The service flow is shown in the figure below.

20.15 Timer 208795


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T20

Timer Name

SS7_TIMER_ISUP_ITUT_T20

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

After sending a CGU (circuit-group unblocking) message, SP A starts this timer, and
waits for a CGUA (circuit-group unblocking acknowledgement) message from SP B.
The service flow is shown in the figure below.

20-15

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

20.16 Timer 208796


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T21

Timer Name

SS7_TIMER_ISUP_ITUT_T21

Value Range

0~600000ms

Default Duration

300000ms

Adjustment Step Length


1ms

Flow Description

After sending a CGU message, SP A starts T21, and waits for a CGUA message
from the peer end. On the first expiry of T21, SP A resends a CGU message, and
restarts T21. The number of resent CGU messages increases by one. On the
second expiry of T21, SP A resends a CGU message again, and restarts T21. The
number of resent CGU messages increases by one. SP A stops sending CGU
messages and stops T21 until the number of resent CGU messages reaches the
maximum number (2) supported by the system.
The service flow is shown in the figure below.

20-16

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

20.17 Timer 208797


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T22

Timer Name

SS7_TIMER_ISUP_ITUT_T22

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length


1ms

Flow Description

After sending a GRS (circuit-group reset) message, SP A starts this timer, and waits
for a GRA (circuit-group reset acknowledgement) message from SP B.
The service flow is shown in the figure below.

20-17

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

20.18 Timer 208798


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T23

Timer Name

SS7_TIMER_ISUP_ITUT_T23

Value Range

0~600000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

After sending a GRS message, SP A starts T23, and waits for a GRA message from
SP B. On the first expiry of T23, SP A resends a GRS message, and restarts T23.
The number of resent GRS messages increases by one. On the second expiry of
T23, SP A resends a GRS message again, and restarts T23. The number of resent
GRS messages increases by one. SP A stops sending GRS messages and stops
T23 until the number of resent GRS messages reaches the maximum number (2)
supported by the system.
The service flow is shown in the figure below.

20.19 Timer 208799


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T24

Timer Name

20-18

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

SS7_TIMER_ISUP_ITUT_T24

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

If the ISUP module does not receive the continuity result of the backward continuity
tone within two minutes, it is considered that the continuity check fails.
The service flow is as follows:
1. During an outgoing continuity check, this timer specifies the duration of
waiting for the backward continuity tone.
2. After sending a continuity tone, the ISUP module starts this timer.
3. If the ISUP module has received the continuity result indicator before
this timer expires, it stops this timer.
4. If the ISUP module has not received the continuity result indicator before
this timer expires, it is considered that the continuity check fails.

20.20 Timer 208800


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T28

Timer Name

SS7_TIMER_ISUP_ITUT_T28

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

20-19

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Flow Description

After sending a CQM (circuit-group query) message, SP A starts this timer, and
waits for a CQR (circuit-group query response) message from SP B.
The service flow is shown in the figure below.

20.21 Timer 208801


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T33

Timer Name

SS7_TIMER_ISUP_ITUT_T33

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of requesting for the calling number. If this timer
expires, SP A releases the call, and the background reports alarm.
The service flow is shown in the figure below.

20-20

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

1. After receiving an IAM message, SP B finds no calling number, so it


requests for the calling number.
2. SP B sends an INR message of requesting for the calling number, and
starts this timer.
3. After receiving the INR message, SP A fills the calling number in an INF
message.
4. After receiving the INF message, SP B stops this timer. The flow of
requesting for the calling number ends. The subsequent steps are the
same with those of the basic call flow.

20.22 Timer 208802


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T52

Timer Name

SS7_TIMER_ISUP_ITUT_T52

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Function Description
20-21

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

This timer is for interaction between internal modules.


1. During an incoming call, after the ISUP module receives an IAM
message, it correctly decodes the message, and sends an
L3L4SetUpInd message to the GCM module. Then the ISUP module
starts this timer.
2. If the ISUP module has received an L4L3SetUpAck message before this
timer expires, it stops this timer.
3. If this timer expires, the ISUP module releases the call (releasing L3
before releasing L4).

20.23 Timer 208803


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T53

Timer Name

SS7_TIMER_ISUP_ITUT_T53

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present.

20.24 Timer 208804


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T54

Timer Name

SS7_TIMER_ISUP_ITUT_T54

Value Range

20-22

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is for interaction between internal modules.


1. After receiving a REL message, the ISUP module correctly decodes the
message, and sends an L3L4ReleaseInd message to the GCM module.
Then the ISUP module starts this timer, and waits for a processing
response message from the call processing module.
2. If the ISUP module has received an L4L3ReleaseAck message before
this timer expires, it stops this timer, and encodes the RLC message.
3. If this timer expires, and if the ISUP module is in the dual-seizure status,
it releases this call, and then encodes the RLC message and notifies the
peer end.

20.25 Timer 208805


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T55

Timer Name

SS7_TIMER_ISUP_ITUT_T55

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

20-23

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

During a basic call flow, after the ISUP module receives an L4L3AlertingInd
message, it starts this timer, and waits for an L4L3AnswerInd message from the
GCM module. If this timer expires, the ISUP module releases the call.
This timer is for interaction between internal modules. The service flow is shown in
the figure below.
T55

1. After receiving an L4L3AlertingInd message, the ISUP module starts this


timer, and waits for an L4L3AnswerInd message.
2. If the ISUP module has received an L4L3AnswerInd message before
this timer expires, it stops this timer.
3. If this timer expires, the ISUP module releases the call.

20.26 Timer 208806


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T56

Timer Name

SS7_TIMER_ISUP_ITUT_T56

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

20-24

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

1ms

Flow Description

This timer is not used at present.

20.27 Timer 208807


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T62

Timer Name

SS7_TIMER_ISUP_ITUT_T62

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present. LPA is only used in ANSI.

20.28 Timer 208808


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T63

Timer Name

SS7_TIMER_ISUP_ITUT_T63

Value Range

0~240000ms

Default Duration

120000ms

20-25

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer for waiting for the answer from the called party during
a national toll call. The service flow is shown in the figure below.

1. SP A originates a call by sending an IAM message to SP B. The IAM


message indicates that this call is a national toll call.
2. After SP A receives an ACM message or the ringing indicator from the
called party, it starts this timer, and waits for an ANM message from SP
B.
3. If SP A has received an ANM message or the answer indicator from the
called party before this timer expires, it stops this timer. If this timer
expires, SP A releases the call.
4. The subsequent steps are the same with those in the message release
flow after the call.

20.29 Timer 208809


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T64

Timer Name

SS7_TIMER_ISUP_ITUT_T64

Value Range

0~240000ms

20-26

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer for waiting for the answer from the called party during
an international toll call.The service flow is shown in the figure below.

1. SP A originates a call by sending an IAM message to SP B. The IAM


message indicates that this call is an international toll call.
2. After SP A receives an ACM message or the ringing indicator from the
called party, it starts this timer, and waits for an ANM message from SP
B.
3. If SP A has received an ANM message or the answer indicator from the
called party before this timer expires, it stops this timer. If this timer
expires, SP A releases the call.
4. The subsequent steps are the same with those in the message release
flow after the call.

20.30 Timer 208810


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T68

Timer Name

SS7_TIMER_ISUP_ITUT_T68

20-27

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After receiving a GetTpCicAck message from the DB, the local office sends an
L3L4TpCallInd message to the GCM module. Then it starts this timer, and waits for
an L4L3TpCallAck message. If this timer expires, the local office directly releases
the call.
The service flow is shown in the figure below.

20.31 Timer 208811


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T69

Timer Name

SS7_TIMER_ISUP_ITUT_T69

Value Range

0~60000ms

Default Duration

20-28

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 20 Timers Related with ISUP Module (ITU Protocol)

30000ms

Adjustment Step Length

1ms

Flow Description

After receiving a GetTpCicAck message from the DB, the local office sends an
L3L4TpCallInd message to the GCM module. Then it starts this timer, and waits for
an L4L3SetUpInd message. If this timer expires, the local office directly releases the
call.
The service flow is shown in the figure below.

20.32 Timer 208812


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T27

Timer Name

SS7_TIMER_ISUP_ITUT_T27

Value Range

0~900000ms

Default Duration

240000ms

Adjustment Step Length

1ms

20-29

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Flow Description

After receiving a COT (continuity failure) message from the peer end, the local
office starts this timer, and waits for a CCR (re-continuity) message. If this timer
expires, the local office sends a RSC (reset) message to the peer end, and releases
the circuit.
The service flow is shown in the figure below.

SS7UP SS7UP

COT

CCR

RSC
RLC

20-30

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter21
Timers Related with ISUP
Module (CHINA Protocol)
———————————————————————————————————————————

21.1 Timer 208821


Macro Name of Timer

SS7_TIMER_ISUP_CN_T1

Timer Name

SS7_TIMER_ISUP_CN_T1

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

21-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SPA SPB

IAM

ACM

Ringing tone

ANM

Connectivity

REL
T1

REL

1. SP B originates s a call to SP A by sending an IAM message to SP A.


2. After receiving the IAM message, SP A returns an ACM (address
completion) message to SP B.
3. SP A returns an ANM message to SP B.
4. SP A clears this call by sending a REL message. Then it starts this timer.
After this timer expires, SP A continues to send REL messages.

21.2 Timer 208822


Macro Name of Timer

SS7_TIMER_ISUP_CN_T5

Timer Name

SS7_TIMER_ISUP_CN_T5

Value Range

0~900000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description
21-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 21 Timers Related with ISUP Module (CHINA Protocol)

This timer is used for the clearing phase. After the ISUP module sends a REL
message, it starts this timer, and waits for a RLC message from the peer end.
The service flow is shown in the figure below.

SPA SPB

IAM

ACM

ANM

REL

REL

RSC

RLC

1. SP B originates s a call to SP A by sending an IAM message to SP A.


2. After receiving the IAM message, SP A returns an ACM (address
completion) message to SP B.
3. SP A returns an ANM message to SP B.
4. SP A clears this call by sending a REL message. Then it starts this timer,
and waits for a RLC message from the peer end.
5. After this timer expires, SP A sends a RSCL message.

21.3 Timer 208823


Macro Name of Timer

SS7_TIMER_ISUP_CN_T6

Timer Name

SS7_TIMER_ISUP_CN_T6

Value Range

0~240000ms

21-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

SPA SPB

SUS
T6

RES

After receiving an SUS message, SP A starts this timer, and waits for a RES
(restoration) message.

21.4 Timer 208824


Macro Name of Timer

SS7_TIMER_ISUP_CN_T7

Timer Name

SS7_TIMER_ISUP_CN_T7

Value Range

0~60000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description1

21-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 21 Timers Related with ISUP Module (CHINA Protocol)

This timer specifies the duration of waiting for the ACM message after sending the
address. If SP A has not received an ACM message before this timer expires, it
releases the circuit.
The service flow is shown in the figure below.

SPA SPB

IAM
T7

ACM

ANM

REL

RLC

1. SP A originates s a call to SP B by sending an IAM or SAM message to


SP B (not shown in the above figure).
2. After sending the address, SP A starts this timer, and waits for an ACM
message from SP B.
3. After SP A receives an ACM message from SP B, it stops this timer.
4. The subsequent steps are the same with those of the basic call flow.

Flow Description 2

During a basic call flow, after sending a SetUpInd message, the ISUP module at the
incoming side starts this timer. If the ISUP module has not received an
EV_L4L3_ALERTING_IND message before this timer expires, it releases the call.
The service flow is shown in the figure below.

ISUP GCM
IAM
EV_L3L4_SETUP_IND

EV_L4L3_ALERTING_IND
REL

RLC

21-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

21.5 Timer 208825


Macro Name of Timer

SS7_TIMER_ISUP_CN_T8

Timer Name

SS7_TIMER_ISUP_CN_T8

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description1

When the IAM message indicates that a continuity check is required or that the
continuity check should be performed at the front section, SP A starts this timer, and
waits for a COT message.
The service flow is shown in the figure below.

SPA SPB

IAM

COT

ACM
ANM

REL

1. SP B originates s a call to SP A by sending an IAM message to SP A.


2. After SP A receives the IAM message indicating that a continuity check
is required to be performed at the local end or the front section, it starts
this timer, and waits for a COT message.
3. After receiving a COT message, SP A stops this timer.
21-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 21 Timers Related with ISUP Module (CHINA Protocol)

4. The subsequent steps are the same with those of the basic call flow.

Flow Description 2

During a basic call flow, after the ISUP module at the outgoing side receives an
EV_L4L3_SETUP_IND message carrying a non-zero continuity indicator from the
GCM module, it starts this timer, and waits for an EV_L4L3_COTRESULT_IND
message. If this timer expires, the ISUP module sends a REL message to the peer
end, releasing the peer end before releasing L4.
The service flow is shown in the figure below.

T8

21.6 Timer 208826


Macro Name of Timer

SS7_TIMER_ISUP_CN_T9

Timer Name

SS7_TIMER_ISUP_CN_T9

Value Range

0~240000ms

Default Duration

120000ms

21-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Adjustment Step Length

1ms

Flow Description1

After receiving an EV_L4L3_ALERTING_IND message from the GCM module, the


ISUP module sends an ACM message to the peer end. Then it starts this timer, and
waits for an EV_L4L3_ANSWER_IND message. If this timer expires, the ISUP
module sends a REL message to the L3 module. The service flow is shown in the
figure below.

ISUP GCM

EV_L4L3_ALERTING_IND
ACM
T9

EV_L4L3_ANSWER_IND

REL

Flow Description 2

After receiving an ACM message from the peer end, the ISUP module starts this
timer, and waits for an ANM message from the peer end. If this timer expires, the
ISUP module sends a REL message to the peer end.
The service flow is shown in the figure below.

21-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 21 Timers Related with ISUP Module (CHINA Protocol)

SPA-ISUP SPB-ISUP

ACM

ANM

REL

RLC

21.7 Timer 208827


Macro Name of Timer

SS7_TIMER_ISUP_CN_T24

Timer Name

SS7_TIMER_ISUP_CN_T24

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

If ISUP module can not receive the continuity result of the backward continuity tone
within two minutes, it is considered that the continuity check fails.
The service flow is as follows:
1. During an outgoing continuity check, this timer specifies the duration of
the ISUP module waiting for the backward continuity tone.
21-9

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

2. After sending a continuity tone, the ISUP module starts this timer.
3. If the ISUP module has received the continuity result indicator before
this timer expires, it stops this timer.
4. If the ISUP module has not received the continuity result indication
before this timer expires, it is considered that the continuity check fails.

21.8 Timer 208828


Macro Name of Timer

SS7_TIMER_ISUP_CN_T33

Timer Name

SS7_TIMER_ISUP_CN_T33

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of requesting for the calling number. If this timer
expires, SP A releases the call, and the background reports alarm.
The service flow is shown in the figure below.

21-10

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 21 Timers Related with ISUP Module (CHINA Protocol)

T33

1. After receiving an IAM message, SP B finds no calling number, so it


requests for the calling number.
2. SP B sends an INR message of requesting for the calling number, and
starts this timer.
3. After receiving the INR message, SPA fills the calling number in an INF
message.
4. After receiving the INF message, SP B stops this timer. The flow of
requesting for the calling number ends. The subsequent steps are the
same with those of the basic call flow.

21.9 Timer 208829


Macro Name of Timer

SS7_TIMER_ISUP_CN_T52

Timer Name

SS7_TIMER_ISUP_CN_T52

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms
21-11

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Flow Description

This timer is for interaction between internal modules.


1. During an incoming call, after the ISUP module receives an IAM
message, it correctly decodes the message, and sends an
L3L4SetUpInd message to the GCM module. Then the ISUP module
starts this timer.
2. If the ISUP module has received an L4L3SetUpAck message before this
timer expires, it stops this timer.
3. If this timer expires, the ISUP module releases the call (releasing L3
before releasing L4).

21.10 Timer 208830


Macro Name of Timer

SS7_TIMER_ISUP_CN_T53

Timer Name

SS7_TIMER_ISUP_CN_T53

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present.

21.11 Timer 208831


Macro Name of Timer
SS7_TIMER_ISUP_CN_T54

Timer Name
SS7_TIMER_ISUP_CN_T54

21-12

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 21 Timers Related with ISUP Module (CHINA Protocol)

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is for interaction between internal modules.


1. After receiving a REL message, the ISUP module correctly decodes the
message, and sends an L3L4ReleaseInd message to the GCM module.
Then the ISUP module starts this timer, and waits for a processing
response message from the GCM module.
2. If the ISUP module has received an L4L3ReleaseAck message before
this timer expires, it stops this timer, and encodes the RLC message.
3. If this timer expires, and if the ISUP module is in the dual-seizure status,
it releases this call, and then encodes the RLC message and notifies the
peer end.

21.12 Timer 208832


Macro Name of Timer

SS7_TIMER_ISUP_CN_T55

Timer Name

SS7_TIMER_ISUP_CN_T55

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description
21-13

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

During a basic call flow, after the ISUP module receives an L4L3AlertingInd
message, it starts this timer, and waits for an L4L3AnswerInd message from the
GCM module. If this timer expires, the ISUP module releases the call.
This timer is for interaction between internal modules. The service flow is shown in
the figure below.

SS7UP GCM

L4L3AlertingInd

L4L3AnswerInd

REL
RLC
L3L4ReleaseInd

L4L3ReleaseAck

1. After receiving an L4L3AlertingInd message, the ISUP module starts this


timer, and waits for an L4L3AnswerInd message.
2. If the ISUP module has received an L4L3AnswerInd message before
this timer expires, it stops this timer.
3. If this timer expires, the ISUP module releases the call.

21.13 Timer 208833


Macro Name of Timer

SS7_TIMER_ISUP_CN_T56

Timer Name

SS7_TIMER_ISUP_CN_T56

Value Range

0~60000ms

Default Duration

30000ms
21-14

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 21 Timers Related with ISUP Module (CHINA Protocol)

Adjustment Step Length

1ms

Flow Description

This timer is not used at present.

21.14 Timer 208834


Macro Name of Timer

SS7_TIMER_ISUP_CN_T62

Timer Name

SS7_TIMER_ISUP_CN_T62

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present. LPA is only used in ANSI.

21.15 Timer 208835


Macro Name of Timer

SS7_TIMER_ISUP_CN_T63

Timer Name

SS7_TIMER_ISUP_CN_T63

Value Range

0~240000ms

21-15

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer used when waiting for the answer from the called
party during a national toll call. The service flow is shown in the figure below.

SPA SPB

IAM(national\international call indicator=0)

ACM
T63

ANM

REL

RLC

1. SP A originates a call by sending an IAM message to SP B. The IAM


message indicates that this call is a national toll call.
2. After SP A receives an ACM message or the ringing indicator from the
called party, it starts this timer, and waits for an ANM message from SP
B.
3. If SP A has received an ANM message or the answer indicator from the
called party before this timer expires, it stops this timer. If this timer
expires, SP A releases the call.
4. The subsequent steps are the same with those in the message release
flow after the call.

21.16 Timer 208836


Macro Name of Timer

SS7_TIMER_ISUP_CN_T64

Timer Name
21-16

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 21 Timers Related with ISUP Module (CHINA Protocol)

SS7_TIMER_ISUP_CN_T64

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer used when waiting for the answer from the called
party during an international toll call. The service flow is shown in the figure below.

SPA SPB

IAM(national\international call indicator=1)

ACM
T64

ANM

REL

RLC

1. SP A originates a call by sending an IAM message to SP B. The IAM


message indicates that this call is an international toll call.
2. After SP A receives an ACM message or the ringing indicator from the
called party, it starts this timer, and waits for an ANM message from SP
B.
3. If SP A has received an ANM message or the answer indicator from the
called party before this timer expires, it stops this timer. If this timer
expires, SP A releases the call.
4. The subsequent steps are the same with those in the message release
flow after the call.

21-17

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

21.17 Timer 208837


Macro Name of Timer

SS7_TIMER_ISUP_CN_T68

Timer Name

SS7_TIMER_ISUP_CN_T68

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After receiving a GetTpCicAck message from the DB, the local office sends an
L3L4TpCallInd message to the GCM module. Then it starts this timer, and waits for
an L4L3TpCallAck message. If this timer expires, the local office directly releases
the call.
The service flow is shown in the figure below.

GCM SS7UP
GetTpCicAck
L3L4TpCallInd
T68

L4L3TpCallAck
REL
RLC
L3L4ReleaseInd
L4L3ReleaseAck

21.18 Timer 208838


Macro Name of Timer
21-18

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 21 Timers Related with ISUP Module (CHINA Protocol)

SS7_TIMER_ISUP_CN_T69

Timer Name

SS7_TIMER_ISUP_CN_T69

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

After receiving a GetTpCicAck message from the DB, the local office sends an
L3L4TpCallInd message to the GCM module. Then it starts this timer, and waits for
an L4L3SetUpInd message. If this timer expires, the local office directly releases the
call.
The service flow is shown in the figure below.

GCM SS7UP
GetTpCicAck
L3L4TpCallInd

L4L3TpCallAck
T69

L4L3SetUpInd
REL
RLC
L3L4ReleaseInd
L4L3ReleaseAck

21.19 Timer 208839


Macro Name of Timer

SS7_TIMER_ISUP_CN_T27

Timer Name
21-19

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SS7_TIMER_ISUP_CN_T27

Value Range

0~900000ms

Default Duration

240000ms

Adjustment Step Length

1ms

Flow Description

After receiving a COT (continuity failure) message from the peer end, the local office
starts this timer, and waits for a CCR (re-continuity) message. If this timer expires,
the local office sends a RSC (reset) message to the peer end, and releases the
circuit.
The service flow is shown in the figure below.
T27

21-20

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter22
Timers Related with ISUP
Module (ANSI Protocol)
———————————————————————————————————————————

22.1 Timer 208841


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T1

Timer Name

SS7_TIMER_ISUP_ANSI_T1

Value Range

0~60000ms

Default Duration
15000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

22-1

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. SP B originates s a call to SP A by sending an IAM message to SP A.


2. After receiving the IAM message, SP A returns an ACM (address
completion) message to SP B.
3. SP A returns an ANM message to SP B.
4. SP A clears this call by sending a REL message. Then it starts this timer.
After this timer expires, SP A continues to send REL messages.

22.2 Timer 208842


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T5

Timer Name

SS7_TIMER_ISUP_ANSI_T5

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

This timer is used for the clearing phase. After the ISUP module sends a REL
message, it starts this timer, and waits for a RLC message from the peer end.
22-2

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

The service flow is shown in the figure below.

1. SP B originates s a call to SP A by sending an IAM message to SP A.


2. After receiving the IAM message, SP A returns an ACM (address
completion) message to SP B.
3. SP A returns an ANM message to SP B.
4. SP A clears this call by sending a REL message. Then it starts this timer,
and waits for a RLC message from the peer end.
5. After this timer expires, SP A sends a RSCL message.

22.3 Timer 208843


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T6

Timer Name

SS7_TIMER_ISUP_ANSI_T6

Value Range

0~120000ms

Default Duration

30000ms

Adjustment Step Length

22-3

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1ms

Flow Description

The service flow is shown in the figure below.

After receiving an SUS message, SP A starts this timer, and waits for a RES
(restoration) message.

22.4 Timer 208844


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T7

Timer Name

SS7_TIMER_ISUP_ANSI_T7

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description 1

This timer specifies the duration of waiting for an ACM message after sending the
address. If SP A has not received an ACM message before this timer expires, it
releases the circuit. The service flow is shown in the figure below.

22-4

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

1. SP A originates s a call to SP B by sending an IAM or SAM message to


SP B (not shown in the above figure).
2. After sending the address, SP A starts this timer, and waits for an ACM
message from SP B.
3. After SP A receives an ACM message from SP B, it stops this timer.
4. The subsequent steps are the same with those of the basic call flow.

Flow Description 2

During a basic call flow, after sending a SetUpInd message, the ISUP module at the
incoming side starts this timer. If the ISUP module has not received an
EV_L4L3_ALERTING_IND message before this timer expires, it releases the call.

22.5 Timer 208845


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T8

Timer Name

SS7_TIMER_ISUP_ANSI_T8
22-5

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description 1

When the IAM message indicates that a continuity check is required or that the
continuity check should be performed at the front end, SP A starts this timer, and
waits for a COT message.
The service flow is shown in the figure below.

1. SP B originates s a call to SP A by sending an IAM message to SP A.


2. After SP A receives the IAM message indicating that a continuity check
is required to be performed at the local end or the front end, it starts this
timer, and waits for a COT message.
3. After receiving the COT message, SP A stops this timer.
4. The subsequent steps are the same with those of the basic call flow.

Flow Description 2

During a basic call flow, after the ISUP module at the outgoing side receives an
EV_L4L3_SETUP_IND message carrying a non-zero continuity indicator from the
GCM module, it starts this timer, and waits for an EV_L4L3_COTRESULT_IND
message. If this timer expires, the ISUP module sends a REL message to the peer
end, releasing the peer end before releasing L4.
The service flow is shown in the figure below.

22-6

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

22.6 Timer 208846


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T9

Timer Name

SS7_TIMER_ISUP_ANSI_T9

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description 1

After receiving an EV_L4L3_ALERTING_IND message from the GCM module, the


ISUP module sends an ACM message to the peer end. Then it starts this timer, and
waits for an EV_L4L3_ANSWER_IND message. If this timer expires, the ISUP
module sends a REL message to the L3 module. The service flow is shown in the
figure below.

22-7

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

T9

Flow Description 2

After receiving an ACM message from the peer end, the ISUP module starts this
timer, and waits for an ANM message from the peer end. If this timer expires, the
ISUP module sends a REL message to the peer end.
The service flow is shown in the figure below.

22.7 Timer 208847


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T12

Timer Name

SS7_TIMER_ISUP_ANSI_T12
22-8

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

After sending a BLO message, the local end starts T12, and waits for a BLA
message from the peer end. If the peer end does not return a BLA message, the
local end sends BLO messages all the while, and stops T12 until T13 expires.
The service flow is shown in the figure below.

SPA SPB

BLO

BLA

22.8 Timer 208848


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T13

Timer Name

SS7_TIMER_ISUP_ANSI_T13

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

22-9

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

After sending a BLO message, the local end starts T13, and waits for a BLA
message from the peer end. On the first expiry of T13, the local end resends a BLO
message, and restarts T13. The number of resent BLO messages increases by one.
On the second expiry of T13, the local end resends a BLO message again, and
restarts T13. The number of resent BLO messages increases by one. The local end
stops sending BLO messages and stops T13 until the number of resent BLO
messages reaches the maximum number (2) supported by the system.
The service flow is shown in the figure below.

22.9 Timer 208849


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T14

Timer Name

SS7_TIMER_ISUP_ANSI_T14

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

After sending a UBL message, the local end starts T14, and waits for a UBA
message from the peer end. If the peer end does not return a UBA message, the
local end sends UBL messages all the while, and stops T14 until T15 expires.
The service flow is shown in the figure below.

22-10

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

22.10 Timer 208850


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T15

Timer Name

SS7_TIMER_ISUP_ANSI_T15

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length


1ms

Flow Description

After sending a UBL message, the local end starts T15, and waits for a UBA
message from the peer end. On the first expiry of T15, the local end resends a UBL
message, and restarts T13. The number of resent UBL messages increases by one.
On the second expiry of T15, the local end resends a UBL message again, and
restarts T15. The number of resent UBL messages increases by one. The local end
stops sending UBL messages and stops T15 until the number of resent UBL
messages reaches the maximum number (2) supported by the system.
The service flow is shown in the figure below.

22-11

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

22.11 Timer 208851


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T16

Timer Name

SS7_TIMER_ISUP_ANSI_T16

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length


1ms

Flow Description

After sending a RSC (circuit reset) message, the local end starts this timer, and
waits for a REL message from the peer end.
The service flow is shown in the figure below.

22-12

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

22.12 Timer 208852


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T17

Timer Name

SS7_TIMER_ISUP_ANSI_T17

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

After sending a RSC message, the local end starts T17, and waits for a REL
message from the peer end. On the first expiry of T17, the local end resends a RSC
message, and restarts T17. The number of resent RSC messages increases by one.
On the second expiry of T17, the local end resends a RSC message again, and
restarts T17. The number of resent RSC messages increases by one. The local end
stops sending RSC messages and stops T17 until the number of resent RSC
messages reaches the maximum number (2) supported by the system.
The service flow is shown in the figure below.

22.13 Timer 208853


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T18

Timer Name

22-13

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

SS7_TIMER_ISUP_ANSI_T18

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

After sending a CGB message, the local end starts T18, and waits for a CGBA
message from the peer end.
The service flow is shown in the figure below.

22.14 Timer 208854


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T19

Timer Name

SS7_TIMER_ISUP_ANSI_T19

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

22-14

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

Flow Description

After sending a CGB message, the local end starts T19, and waits for a CGBA
message from the peer end. On the first expiry of T19, the local end resends a CGB
message, and restarts T19. The number of resent CGB messages increases by one.
On the second expiry of T19, the local end resends a CGB message again, and
restarts T19. The number of resent CGB messages increases by one. The local end
stops sending CGB messages and stops T19 until the number of resent CGB
messages reaches the maximum number (2) supported by the system.
The service flow is shown in the figure below.

22.15 Timer 208855


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T20

Timer Name

SS7_TIMER_ISUP_ANSI_T20

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

After sending a CGU (circuit-group unblocking) message, SP A starts this timer, and
waits for a CGUA (circuit-group unblocking acknowledgement) message from SP B.
The service flow is shown in the figure below.

22-15

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

22.16 Timer 208856


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T21

Timer Name

SS7_TIMER_ISUP_ANSI_T21

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length


1ms

Flow Description

After sending a CGU message, SP A starts T21, and waits for a CGUA message
from the peer end. On the first expiry of T21, SP A resends a CGU message, and
restarts T21. The number of resent CGU messages increases by one. On the
second expiry of T21, SP A resends a CGU message again, and restarts T21. The
number of resent CGU messages increases by one. SP A stops sending CGU
messages and stops T21 until the number of resent CGU messages reaches the
maximum number (2) supported by the system.
The service flow is shown in the figure below.

22-16

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

22.17 Timer 208857


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T22

Timer Name

SS7_TIMER_ISUP_ANSI_T22

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length


1ms

Flow Description

After sending a GRS (circuit-group reset) message, SP A starts this timer, and waits
for a GRA (circuit-group reset acknowledgement) message from SP B.
The service flow is shown in the figure below.

22-17

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

22.18 Timer 208858


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T23

Timer Name

SS7_TIMER_ISUP_ANSI_T23

Value Range

0~120000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

After sending a GRS message, SP A starts T23, and waits for a GRA message from
SP B. On the first expiry of T23, SP A resends a GRS message, and restarts T23.
The number of resent GRS messages increases by one. On the second expiry of
T23, SP A resends a GRS message again, and restarts T23. The number of resent
GRS messages increases by one. SP A stops sending GRS messages and stops
T23 until the number of resent GRS messages reaches the maximum number (2)
supported by the system.
The service flow is shown in the figure below.

22.19 Timer 208859


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T24

Timer Name

22-18

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

SS7_TIMER_ISUP_ANSI_T24

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

If the ISUP module cannot receive the continuity result of the backward continuity
tone within two minutes, it is considered that the continuity check fails.
The service flow is as follows:
1. During an outgoing continuity check, this timer specifies the duration of
waiting for the backward continuity tone.
2. After sending a continuity tone, the ISUP module starts this timer.
3. If the ISUP module has received the continuity result indicator before
this timer expires, it stops this timer.
4. If the ISUP module has not received the continuity result indicator before
this timer expires, it is considered that the continuity check fails.

22.20 Timer 208860


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T28

Timer Name

SS7_TIMER_ISUP_ANSI_T28

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

22-19

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Flow Description

After sending a CQM (circuit-group query) message, SP A starts this timer, and
waits for a CQR (circuit-group query response) message from SP B.
The service flow is shown in the figure below.

22.21 Timer 208861


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T33

Timer Name

SS7_TIMER_ISUP_ANSI_T33

Value Range

0~60000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of requesting for the calling number. If this timer
expires, SP A releases the call, and the background reports alarm.
The service flow is shown in the figure below.

22-20

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

1. After receiving an IAM message, SP B finds no calling number, so it


requests for the calling number.
2. SP B sends an INR message of requesting for the calling number, and
starts this timer.
3. After receiving the INR message, SPA fills the calling number in an INF
message.
4. After receiving the INF message, SP B stops this timer. The flow of
requesting for the calling number ends. The subsequent steps are the
same with those of the basic call flow.

22.22 Timer 208862


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T50

Timer Name

SS7_TIMER_ISUP_ANSI_T50

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description
22-21

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

This timer is not used at present.

22.23 Timer 208863


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T51

Timer Name

SS7_TIMER_ISUP_ANSI_T51

Value Range

0~60000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present.

22.24 Timer 208864


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T52

Timer Name

SS7_TIMER_ISUP_ANSI_T52

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

22-22

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

Flow Description

This timer is for interaction between internal modules.


1. During an incoming call, after the ISUP module receives an IAM
message, it correctly decodes the message, and sends an
L3L4SetUpInd message to the GCM module. Then the ISUP module
starts this timer.
2. If the ISUP module has received an L4L3SetUpAck message before this
timer expires, it stops this timer.
3. If this timer expires, the ISUP module releases the call (releasing L3
before releasing L4).

22.25 Timer 208865


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T53

Timer Name

SS7_TIMER_ISUP_ANSI_T53

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer is not used at present.

22.26 Timer 208866


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T54

Timer Name

SS7_TIMER_ISUP_ANSI_T54

22-23

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is for interaction between internal modules.


1. After receiving a REL message, the ISUP module correctly decodes the
message, and sends an L3L4ReleaseInd message to the GCM module.
Then the ISUP module starts this timer, and waits for a processing
response message from the GCM module.
2. If the ISUP module has received an L4L3ReleaseAck message before
this timer expires, it stops this timer, and encodes the RLC message.
3. If this timer expires, and if the ISUP module is in the dual-seizure status,
it releases this call, and then encodes the RLC message and notifies the
peer end.

22.27 Timer 208867


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T55

Timer Name

SS7_TIMER_ISUP_ANSI_T55

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

22-24

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

During a basic call flow, after the ISUP module receives an L4L3AlertingInd
message, it starts this timer, and waits for an L4L3AnswerInd message from the
GCM module. If this timer expires, the ISUP module releases the call.
This timer is for interaction between internal modules. The service flow is shown in
the figure below.
T55

1. After receiving an L4L3AlertingInd message, the ISUP module starts this


timer, and waits for an L4L3AnswerInd message.
2. If the ISUP module has received an L4L3AnswerInd message before
this timer expires, it stops this timer.
3. If this timer expires, the ISUP module releases the call.

22.28 Timer 208868


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T56

Timer Name

SS7_TIMER_ISUP_ANSI_T56

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

22-25

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1ms

Flow Description

This timer is not used at present.

22.29 Timer 208869


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T63

Timer Name

SS7_TIMER_ISUP_ANSI_T63

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer for waiting for the answer from the called party during
a national toll call. The service flow is shown in the figure below.

1. SP A originates a call by sending an IAM message to SP B. The IAM


message indicates that this call is a national toll call.
22-26

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

2. After SP A receives an ACM message or the ringing indicator from the


called party, it starts this timer, and waits for an ANM message from SP
B.
3. If SP A has received an ANM message or the answer indicator from the
called party before this timer expires, it stops this timer. If this timer
expires, SP A releases the call.
4. The subsequent steps are the same with those in the message release
flow after the call.

22.30 Timer 208870


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T64

Timer Name

SS7_TIMER_ISUP_ANSI_T64

Value Range

0~240000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal timer for waiting for the answer from the called party during
an international toll call. The service flow is shown in the figure below.

22-27

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

1. SP A originates a call by sending an IAM message to SP B. The IAM


message indicates that this call is an international toll call.
2. After SP A receives an ACM message or the ringing indicator from the
called party, it starts this timer, and waits for an ANM message from SP
B.
3. If SP A has received an ANM message or the answer indicator from the
called party before this timer expires, it stops this timer. If this timer
expires, SP A releases the call.
4. The subsequent steps are the same with those in the message release
flow after the call.

22.31 Timer 208871


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T67

Timer Name

SS7_TIMER_ISUP_ANSI_T67

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

22-28

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

Flow Description

The service flow is shown in the figure below.

1. The continuity check initiated by SP A to SP B fails, so SP A sends a


COT message carrying the failure flag to SP B.
2. SP A continues to send CCR messages to SP B.
3. SP A starts this timer, and waits for a LPA message from SP B.

22.32 Timer 208872


Macro Name of Timer

SS7_TIMER_CGST_SHORT

Timer Name

SS7_TIMER_CGST_SHORT

Value Range

0~60000ms

Default Duration

500ms

Adjustment Step Length

1ms

Flow Description

Both the SS7UP module and the BICC module use the same
LinkCongestShortTimer.

22-29

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

22.33 Timer 208873


Macro Name of Timer

SS7_TIMER_CGST_LONG

Timer Name

SS7_TIMER_CGST_LONG

Value Range

0~60000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

Both the SS7UP module and the BICC module use the same
LinkCongestLongTimer.

22.34 Timer 208874


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T68

Timer Name

SS7_TIMER_ISUP_ANSI_T68

Value Range

0~60000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

22-30

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

After receiving a GetTpCicAck message from the DB, the local office sends an
L3L4TpCallInd message to the GCM module. Then it starts this timer, and waits for
an L4L3TpCallAck message. If this timer expires, the local office directly releases
the call.
The service flow is shown in the figure below.

22.35 Timer 208875


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T69

Timer Name

SS7_TIMER_ISUP_ANSI_T69

Value Range

0~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

After receiving a GetTpCicAck message from the DB, the local office sends an
L3L4TpCallInd message to the GCM module. Then it starts this timer, and waits for
an L4L3SetUpInd message. If this timer expires, the local office directly releases the
call.

22-31

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

The service flow is shown in the figure below.

22.36 Timer 208876


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T27

Timer Name

SS7_TIMER_ISUP_ANSI_T27

Value Range

0~900000ms

Default Duration

200000ms

Adjustment Step Length

1ms

Flow Description

After receiving a COT (continuity failure) message from the peer end, the local
office starts this timer, and waits for a CCR (re-continuity) message. If this timer
expires, the local office sends a RSC (reset) message to the peer end, and releases
the circuit.
The service flow is shown in the figure below.

22-32

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

SS7UP SS7UP

COT

CCR

RSC
RLC

22.37 Timer 208891


Macro Name of Timer

SS7_TIMER_UNACCESS_PROTECT

Timer Name

SS7_TIMER_UNACCESS_PROTECT

Value Range

1000~120000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

This timer is an internal protection timer of the signaling point being inaccessible.
The service flow is as follows:
1. After receiving a message of the signaling point being inaccessible, the
ISUP module starts this timer.
2. If the ISUP module has received a message of the signaling point being
accessible before this timer expires, it stops this timer.
3. After this timer expires, the ISUP module processes the flow of the
signaling point being inaccessible.

22-33

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

22.38 Timer 208893


Macro Name of Timer

SS7_TIMER_CALLRELSCAN

Timer Name

SS7UP CALL RELEASE SCAN

Value Range

100~30000ms

Default Duration

1000ms

Adjustment Step Length

1ms

Flow Description

1. If the query on the call release to the local office is not completed, or if
the call is not successfully released, the ISUP module starts this timer.
2. After this timer expires, the ISUP module releases the call in the stable
status.

22.39 Timer 208894


Macro Name of Timer

SS7_TIMER_ISUP_ITUT_T4

Timer Name

SS7_TIMER_ISUP_ITUT_T4

Value Range

300000~900000ms

Default Duration

300000ms

Adjustment Step Length

1ms

22-34

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


Chapter 22 Timers Related with ISUP Module (ANSI Protocol)

Flow Description

1. After sending a UPT message to the peer end, the local office starts this
timer.
2. If the local office has received a UPA message before this timer expires,
it stops this timer.
3. After this timer expires, the local office resends the UPT message, and
restarts this timer.

22.40 Timer 208895


Macro Name of Timer

SS7_TIMER_ISUP_ANSI_T37

Timer Name

SS7_TIMER_ISUP_ANSI_T37

Value Range

30000~30000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

1. After sending a UPT message to the peer end, the local office starts this
timer.
2. If the local office has received a UPA message before this timer expires,
it stops this timer.
3. After this timer expires, the local office resends the UPT message, and
restarts this timer.

22.41 Timer 200004


Macro Name of Timer

DB_WPSTQT_Timer1

Timer Name

22-35

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference Ⅰ

DB_WPSTQT_Timer1

Value Range

10000~120000ms

Default Duration

28000ms

Adjustment Step Length

1ms

Flow Description

1. During an outgoing WPS&gets call, when the ISUP module receives a


waiting indicator, it starts this timer.
2. After receiving a message, the ISUP module stops this timer.
3. If this timer expires, the ISUP module releases the call.

22-36

SJ-20101208143956-020|2011-2-28(R1.0) ZTE Proprietary and Confidential


A Index
———————————————————————————————————————————

AGR module III, 17-2, 17-3, 17-4, 17-5, 17-6, 21-8, 21-9, 21-10, 21-12, 21-13, 21-14, 22-2,
17-7, 17-8, 17-9, 17-10, 17-11, 17-12, 17-13, 22-5, 22-6, 22-7, 22-8, 22-19, 22-23, 22-24,
17-14 22-25, 22-33, 22-34, 22-36
ALCAP module II, 5-2, 5-3, 5-4, 5-5 LICA module II, 7-1, 7-2, 7-3, 7-4, 7-5, 7-6,
CAS module II, 6-9, 16-10, 16-13 7-7, 7-8, 7-9, 7-10, 7-11, 7-12, 7-13, 7-14,
GCM module II, 6-2, 6-3, 6-4, 6-5, 6-6, 6-7, 7-15, 7-16, 7-17, 8-5
6-8, 6-9, 6-10, 6-15, 6-16, 6-17, 6-18, 6-19, LIM module II, 8-1, 8-2, 8-3, 8-4, 8-5
6-20, 6-21, 6-22, 6-23, 6-24, 6-25, 6-26, MTP2 module I
6-27, 6-28, 6-29, 6-30, 6-31, 6-32, 7-17, MTP3 module I
15-17, 15-18, 15-19, 15-20, 15-21, 15-22, PBRT module II, 9-1, 9-2, 9-3, 9-4
15-23, 15-24, 15-25, 15-26, 16-1, 16-2, 16-4, SCCP module I, 1-1, 1-2, 1-3, 1-4, 1-5, 1-6,
16-5, 16-7, 16-8, 16-9, 16-16, 16-17, 16-18, 1-7
16-20, 16-21, 16-22, 17-2, 17-5, 17-6, 17-7, SIGTRANT module II
17-8, 17-9, 17-10, 17-11, 17-12, 17-13, SIPCM module II
17-14, 18-1, 18-2, 18-4, 18-37, 18-38, 18-39, SORMUP module II, 11-1, 11-2, 11-3, 11-4,
18-46, 19-1, 19-2, 19-4, 19-13, 19-14, 19-15, 11-5
19-22, 19-23, 20-6, 20-7, 20-22, 20-23, SPS Alarm module II
20-24, 20-28, 20-29, 21-7, 21-8, 21-12, TCM module II, 12-1, 12-2, 12-3, 12-4, 12-5,
21-13, 21-14, 21-18, 21-19, 22-6, 22-7, 12-6
22-23, 22-24, 22-25, 22-31 TUP module 18-1, 18-2, 18-4, 18-5, 18-37,
ISDN module II, 15-14, 15-16, 15-17 18-38, 18-39, 18-40, 19-1, 19-2, 19-4, 19-6,
ISUP module 20-2, 20-5, 20-6, 20-7, 20-8, 19-12, 19-13, 19-14, 19-15, 19-16
20-19, 20-22, 20-23, 20-24, 21-3, 21-5, 21-7,