Sl._| Description of Specifications . Features & Testing Requirement. No. 1. | Analog Inputs: 4 no's. of 4-20 mA de inputs into 250 ohms input Resistor. a) Accuracy + 0.5% or better b) Resolution 12 Bits ©) Input Filter time constant 0 t0 999 sec or more (selectable time constant for analog inputs), 2. | Digital Inputs: Two contact inputs (potential free) 3. | Analog Outputs: Two analog outputs programmable for any parameter ( One isolated control output and one non isolated aux. output) a) Control Output: Isolated 4-20 mA de into 660 -Ohms (max.) 'b) Auxiliary Output: Non Isolated 4-20 mA de signal into 500 -Ohms( Max.) ©) Accuracy 0.5% or better @) Output Noise: 1% peak to peak or better 4. | Digital Outputs: Two potential free contact outputs (2 Nos. Relays having contact rating 15W/VA) & shall be programmable independently. Displays: a) Bar-graph Indicator = Shall use dual 101 segment green fluorescent display to indicate Set point and Measurement on one side and output on another side on front facia, The set point shall be flashing. 'b) Range for input & output 0 to 100 % at bar-graph ©) Resolution 1% 4) Digital Display Green 8 digit. 7 Segment fluorescent. ©) LED Indicator To indicate Auto/Manual. Remote/Local, Work station/Panel, Alarm. 1) Setpoint Manipulation : Through increase/decrease keys on front facia 2) Output Manipulation: Through increase/decrease keys on front facia hh) Mode Selection ‘Auto / Manual keys on front facia. i) Setpoint Selection = Remote/Local keys on front facia. j) Workstation/Panel selection: Through Workstation’ Panel Keys on front panel. 1) Cysle Time Programmable (minimum 100 milli second ) 1. Alarm Indicator TED shall be mounted on front facia 1m) Watch Dog Indicator LED shall be mounted on front facia and begin to flash when microprocessor fails. 6. | Suppl Woltags a) AC Supply Voltage 110 Vac, SOHz; +/- 10% ) Power Consumption VA Max, 7. | Transmitter Power Supply: It should have a provision for 25 V de nominal fickl power to two-4-20 mA de transmitters 8, | Eavironmental Specifications a) Operating temperature 5°C 10 50°C or bewer ) Relative humidity 5 and 95% non-condensing 9, _ | Physical Specifications: a) Power Connections 3 Pin connector with 3 t0 4 feet cable, 'b) Signal Connections _ 32 position Terminal blocks with compression, ‘terminal for wires sizes upto 2.5 sq.mm (14 AWG) ©) Weight ‘Not more than 5.5 Kgs ‘Mounting: Panel mounied (Panel cut out: 138 mm (H) X 68 mm (W)). ©) Coniroller Housing Size” Height: 137 mm, Widih: 66 mm. (Tolerance +/- 0.5 mm) and Length : Between 490 to 520 mm. 1) Bezel Size of Controller : 72 mm (W) x 169 mm (H) (Tolerance +/- 0.5 mm) TD, | Software Blocks: PID Controller should have minimum following 19 nos Software functions blocks Programmable from front keys of the controller. No external media required to programme controller. 3) PiD-Proportional Integral Derivative (PID) block having Proportional Band setting: 1 to 500%, Integral time setting 0 to 9999 sec, Derivative time setting 0 to 9999 sce and shall be configured for P, PI, PD & PID. i) Differential Gap Integral Piccowise linear characterizer Alara Logic Gate ‘Switch Selector Tag compensation Dead Time Signal Selector Ramp Generator Timer xii) Computation xiv) Summer xx) Accumulator Xvi) Square root extractor xvii) Pulsar xviii) Constant 12. Salient Features: Controller should have following salient features. a) Application like simple controller ( P, PI, PD & PID). three element boiler drum level control, Ratio control, cascade control, feed forward or non linear control with BUMPLESS transfer from manual to auto & auto to manual shall be easily met. ’b) Programmable, Configuration & Parameter entry through front panel Keys. No need of separate unit for configuration & parameter entry. ©) No batteries shall be required for data retention during power failure @) Power failure recover logic ) Pass code security for any unauthorized change in configuration/loop parameters, Testing of Controllers and Documents Requirements a) Pre-dispatch inspection will be done by NPCIL QA. b) Burn in Test: ( To be performed by supplier ) Each controller shall go under burn in test for 100 hrs at room temperature >27degree C in energized condition. There shall not be any failures, malfunction of controller. After performing the above test, Test Report to be submitted. ©) Power ON/OFF Cycling Test: (1 110 VAC Power Supply ON/OFF cycling test shall be carried out on each controller. The AC power supply shall be turned ON and OFF immediately for a total 10 cycles. There shall not be any failure, malfunction in the controller. After performing the above test, Test Report to be submitted be performed by supplier )

You might also like