Anesthetic Gas Scavenging System (AGSS)

The materials and information provided via this brochure are


Type of the Applicable Disposable System: Low flow
Size: 430 mm x 147 mm x 95 mm
distributed internationally, but not all the products or services
found on this brochure are necessarily available in your country
or area. Please contact local office or agents to make sure of the
A5
Extract Flow: 25 to 50 L/min availability of the relevant products or services. Anesthesia System
Type of the Applicable Disposable System: High flow Brazil
Address: Rua Joaquim Floriano, 488, floor Intermediário - cj 02,
Size: 430 mm x 147 mm x 95 mm Itaim Bibi, São Paulo - SP, CEP 04534-002, Brazil
Tel: (55-11) 3078-8026
Extract Flow: 75 to 105 L/min
Canada
Interface Specification Address: 4250 Kingsway, Suite 206, Burnaby, BC, Canada V5H 4T7

Communication Port (SP1): RS-232C compatible serial interface (DB9)


Tel: (1-604) 451-1199
Stockholm
Technical Specifications
Egypt Moscow
Network Port (CS1): RJ-45 network port Address: 24th floor,34 EL-Obour Buildings, Salah Salem Amsterdam Physical Specification
London Frankfurt Vancouver
Street, Helioplis, Cairo, Egypt
USB Ports (SB1, SB2): Two USB ports Tel: (20-2) 2260-9728 Paris Milan Seattle Toronto Dimensions and Weight
Istanbul Beijing Mahwah, NJ
Madrid 31 Branch Offices
Nanjing
Data Port (DP1): One test port for connection of calibration equipment by a Mindray-authorized service representative France Xi’an
Shanghai Height: 1400 mm
Address: Europarc Créteil Cedex 123, Chemin des Bassins 94000 Cairo New Delhi Chengdu
Global HQ in
Electrical specifications Créteil France Mumbai Shenzhen Mexico City Width: 1050 mm
Tel: (33-1) 4513-9145
Main Electrical Power Bogota Depth: 805 mm
Germany
Address: Zwischen den Bächen 4, 64625 Bensheim Jakarta
Power Supply Input Voltage: 100-240 VAC, 50/60 Hz, 7A max Weight: 160 kg(without vaporizers and gas cylinders)
Tel: (49-6251) 17524-0
Power Supply Current Input: 7 A max (2 A max for A5 unit, 5 A max for auxiliary outlets) Sao Paulo Top Shelf
India
Power Consumption: Approx. 200 VA (not including auxiliary outlets) Address: Unit No. 401/402, NDM-1, Netaji Subhash PlaceWazirpur
Weight limit: 40 kg
District Centre, New Delhi 110 034 India
Power Cord: 5M (length) Tel: (91-11) 4923-0000 Width: 616 mm
Battery Power Indonesia
Address: Menara Dea 1, Suite 301, Kav E4 No.3/1, Mega Kuningan, Subsidiary R&D Center Depth: 362 mm
Battery type: Sealed Lithium-ion, 11.1 V, 4.5 Ah (2 batteries) Jakarta Selatan 12950, Indonesia
Tel: (62-21) 576-2650
Work Surface
Battery Run-time: New battery: minimum 150 minutes under typical operating conditions Italy
Height: 850 mm
Time to Shutdown from Lower Battery Alarm: 5 minutes minimum (new fully-charged battery) Address: Via Girardo Patecchio, 4 - 20141 Milano, Italy
Width: 616 mm
Tel: (39-02) 57402-4444
Battery Charge Time: 8 hours max from an initial charge of 10%. Charging occurs whenever AC is applied to the A5 System(New Battery) Depth: 380 mm
Mexico
Auxiliary Electrical Outlets Address: Insurgentes Sur # 1787 Piso 2, DIN Rail
Col. Guadalupe Inn, Mexico D.F. 01020
Number of Outlets: 4 Tel: (52-55) 5661-9450 Supporting weight: 25 kg at a maximum distance of 0.41 m
Output Current: 3 A for each outlet, 5 A for total Netherlands Drawer (Internal Dimensions)
Address: Saturnusstraat 17, 2132HB Hoofddorp,
Environmental specifications The Netherlands Height: 135 mm
Tel: (31-23) 574-9656
Operating Temperature: +10 to +40°C Width: 440 mm
Russia
Storage Temperature: - 20 to +60°C (Oxygen sensor: -20 to +50°C) Address: Kondratyuka Str. 3 129515, Moscow Depth: 385 mm
Tel: (7-499) 553-6036
Humidity (Operating and Storage): 15 to 90% RH, non-condensing Bag Arm
Spain
Atmospheric Pressure (Operating): 70 kPa - 103 kPa Address:Avenida Manoteras 38, Bloque B, Bajo B008. Madrid Height: 1150 mm
28050, Spain
Atmospheric Pressure (Storage): 50 kPa - 103 kPa Tel: (34-91)392-3754 Length: 312 mm
Resistance to Ingress of Fluids: Complies with the requirements of clause 44.3 in IEC 60601-1 and also the requirements in IEC 60529 for Turkey Swiveling angle: 150°
Address: General Ali Rıza Gürcan Cad. Metropol Center No:31 A
Non-protective equipment (IPX0) Blok K.13 D.52 Merter/Istanbul, Turkey Casters
Tel: (90-212) 482-0877
Diameter: 15 cm
UK
Address: 3 Percy Road, St. John's Park, Huntingdon, Cambs, Pe29 Brakes: central brake with lock/unlock indicator
6SZ, United Kingdom
Tel: (44-1480) 416-840 Work Light
USA Settings: Off, Low, High
Address: 800 MacArthur Blvd., Mahwah, NJ 07430-0619, USA
Tel: (1-800) 288 2121, (1-201) 995-8000 Screen
Display: Color LCD, 15inch, diagonal TFT with touch screen Display parameters: All setting and alarm parameters
(including Breath rate, I:E ratio, Tidal volume, Minute volume, PEEP, Pmean, Ppeak, Pplat, and O2 concentration)

Display graphics: Waves of Pressures-Time, Flow-Time


Spirometry Loops: Pressure-Volume, Flow-Volume
Timer: Display on the screen
Screen Control: Touch pad or Touch screen
Ventilator Specifications
Modes of ventilation
Manual/Spontaneous Ventilation

2011
P/N:ENG-A5date-420285-20110727
Volume Control Ventilation (VCV) with tidal volume compensation ≥30 cmH2O: not defined Auxiliary O2Gas Power Outlet
Pressure Control Ventilation (PCV) with/without volume guarantee(VG) Respiration Monitoring: ±1bpm or 10% of the set value, whichever is smaller Pressure range: 280 to 600 kPa
Pressure Support Ventilation (PS) with apnea backup Minute Volume Monitoring: 0 to 30 L/min ±15% of the displayed value, repeatable to ±5% over a 1-hour period Maximum flow: ≥90 L/min
Synchronized Intermittent Mandatory Ventilation (SIMV-Volume Controlled and SIMV-Pressure Controlled) Alarm limits O2 Flush
Ventilation Parameters Ranges Paw High: The greater of 10 and (Paw Low+1) to 100 cmH2O Flow rate: 35 to 50 L/min
Tidal Volume Range: 20 -1500mL(increments of 1 mL) (VCV, SIMV-VC, PCV) Paw Low: 0 to the lesser of 70 and (Paw High–1) cmH2O Vaporizer
Pressure (Pinsp) Range: 5 - 70 cmH2O (increments of 1 cmH2O) (PCV, SIMV-PC) MV High: The greater of 0.2 and (MV Low+0.1) to 25 L/min Anesthetic agent delivery
Pressure (Plimit) Range: 10 -100 cmH2O (increments of 1 cmH2O) (VCV, SIMV-VC) MV Low: 0 to the lesser of 20 and (MV High–1) L/min Vaporizer: Penlon Sigma Delta, Sigma Alpha or Mindray V60 Anesthetic vaporizer
Pressure support (ΔP) Range: 3 - 50 cmH2O (increments of 1 cmH2O) (SIMV-VC, SIMV-PC, PS) FiO2 High: The greater of 21 and (FiO2 Low+1) to 100% Type: Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane
Respiration Rate Range: 4 - 100 bpm (increments of 1 bpm) (VCV, PCV,SIMV-VC, SIMV-PC) FiO2 Low: 18 to the lesser of 98 and (FiO2 High–1)% Vaporizer positions: 3 positisons (2 active, 1 inactive)
Minimum Rate Range: 2 - 60 bpm (increments of 1 bpm) (PS) Data Storage (Non-Volatile) and Recording Mounting mode: Selectatec® with interlocking function
I:E Range: 4:1 - 1:8 (increments of 0.5) (VCV, PCV) Configuration Storage: Factory configuration, one user configuration Breathing Circuit Specification
Tpause Rang: OFF, 5 - 60 % (increments of 1%) (VCV, SIMV-VC) Patient types: Adult, child, and small child for each Configuration CO2 Absorber Assembly
Tinsp Range: 0.2 - 5sec (increments of 0.1s) (SIMV-VC, SIMV-PC) Log Storage: 500 entries of alarm log Absorber capacity: 1 Pre-Pak or 1500 mL
Trigger Range: 1 - 15L/min (increments of 1L/min) (SIMV-VC, SIMV-PC, PS) 500 entries of activity log Absorber Canister Contents: 1 Pre-Pak canister or Loose Fill absorbent
Tslope Range: 0.0 -2.0sec (increments of 0.1s) (SIMV-VC, SIMV-PC, PCV, PS) 500 entries of error log Water Collection Cup
VtG Range: OFF, 20 -1500mL (increments of 1 mL) (PCV) 500 entries of service log Mode: Detachable separately
PlimVG Range: 5 -100cmH2O (increments of 1 cmH2O) (PCV) Pneumatic Specifications Capacity: 6 mL
Apnea Ti Range: 0.2 -5sec (increments of 0.1s) (PS) Pipeline Supply Inspiratory Airway Pressure Gauge
Positive End Expiratory Pressure (PEEP) Gas Configuration: O2, N2O and Air Range: -20 to 100 cmH2O
Type: Integrated, Electronically controlled Pipeline input range: 280 to 600 kPa (40 to 87 psi) Accuracy : ±(4% of full scale reading + 4% of actual reading)
Range: OFF, 3 to 30 mH2O (increments of 1 cm H2O) (VCV, PCV, SIMV-VC, SIMV-PC, PS) Pipeline connections: DISS or NIST Flow sensor
Ventilator performance Cylinder Supply Type: Variable orifice flow sensor
Drive Pressure Range: 280 to 600kPa Cylinder Supply: E size Cylinder (American and UK style) Location: Inspiratory and expiratory port
Peak Gas Flow: 110 L/min O2 Cylinder Input Range: 6.9 to 15 MPa (1000 to 2175 psi) Oxygen sensor
Flow Valve Range : 1 to 110 L/min N2O Cylinder Input Range: 4.2 to 6 MPa (600 to 870 psi) Type: Galvanic fuel cell
Ventilator Monitoring Air Cylinder Input Range: 6.9 to 15 MPa (1000 to 2175 psi) Breathing system connections
Minute Volume Range: 0 -100 L Cylinder Connections: Pin-Index Safety System (PISS) Exhalation connection: 22 mm OD ISO / 15 mm ID ISO conical
Tidal Volume Range: 0 - 3000 mL/min Yoke Configuration: O2, N2O, Air Inhalation connection: 22 mm OD ISO /15 mm ID ISO conical
Inspired Oxygen (FiO2): 18% -100% N2O Automatic Cutoff Manual bag port: 22 mm OD ISO /15 mm ID ISO conical
Peak Pressure (Peak): -20 - 120 cmH2O An N2O automatic cutoff stops the flow of N2O when O2 flow is less than 200 mL/min. Connections to a Gas Scavenger: 30 mm OD ISO
Mean Pressure (Pmean): -20 - 120 cmH2O Electronic display and mechanical control flow meters Adjustable Pressure Limiting (APL) valve

Plateau Pressure(Pplateau): -20 - 120 cmH2O Configuration : O2,N2O, Air Range: SP, 5 to 75 cmH2O

PEEP Range: 0 -70 cmH2O Displayed range (O2, N2O, Air): 0 to 15 L/min Adjustable Range of Motion: 330

Rate Range: 0 - 120 bpm Control range (O2, Air): 0 to 15 L/min Tactile Knob Indication: ≥30 cmH2O

Ventilator accuracy Control range (N2O): 0 to 10 L/min Bag-to-Ventilator Switch

Control/Monitoring Accuracy Accuracy: ±10% or 0.12 L/min, whichever is greater Type: Bi-stable

Volume Control: < 60mL, ±10mL Resolution: 50 mL/min @ 0 to 1 L/min Control: The switch between manual ventilation and mechanical ventilation

≥60 mL and ≤210mL, ±15mL 100 mL/min @ 1 to 15 L/min Materials

210mL ,±7 % of the set value Total Flow Meter All materials in contact with exhaled patient’s gas are autoclavable, except flow sensors, O2 cell, and mechanical pressure gauge.

Pressure Control: Pinsp: ±2.5 cmH2O or ± 7% of the set value, whichever is greater Control range: 0 to 10 L/min ±10% of the indicated value for flows(between 10% and 100% of full scale with Oxygen) All materials in contact with patient’s gas are latex-free.

Plimt: ±10% of the set value O2 Controls Breathing circuit parameters


PEEP Control: 3 to 30H2O: ±2 cm H2O or ± 10% of the displayed value, whichever is greater O2 supply failure alarm: ≤ 220 kPa (32 psi) System Compliance: ≤ 2mL/cm H2O Volume of gas lost due to internal compliance (manual ventilation mode only)

OFF: not defined Hypoxic Guard System Impedance in Manual /Mode: ≤ 6 cmH2O (the gas under test is a bi-directional sine wave at a frequency of 20 with tidal volume of 1 L)
Volume Monitoring: < 60mL, ±10mL Oxygen Ratio Controller: Oxygen concentration ≥ 21% Impedance in Mechanical Ventilation Mode: ≤ 6 cmH2O (the gas under test is a semi-sine wave at a frequency of 20 with tidal volume of 1 L)
≥60 mL and ≤210mL, ±18mL Provides 25% ± 4% O2 when N2O valve is fully open and O2 flow range is 0.8L/min to 3L/min. Leakage: ≤ 150 mL @ 3kPa
≥210mL ±9% of the set value Auxiliary O2 and Air Flow meter System Safety Pressure on Patient Circuit: 110 ±10 cmH2O
Airway Pressure Monitoring: ±2 cmH2O or ± 5% of the set value, whichever is greater Flow range: For each meter 0 to 15 L/min
PEEP Monitoring: 0 to 30 cmH2O: ±2 cm H2O or ± 10% of the displayed value, whichever is greater Indicator: Flow tube Selectatec® is the registered trademark of GE/Detax-Ohmeda.