You are on page 1of 2

Job No Sheet No Rev

P7531 1 A2

Part 1
Software licensed to
Job Title seawater filtration package Ref 1
By MEZ Date21-Feb-18 Chd NAS
Client TecnipFMC File seawater filter package_2 Date/Time 23-Feb-2018 21:49

Job Information
Engineer Checked Approved

Name: MEZ NAS


Date: 21-Feb-18 21-Feb-18

Structure Type SPACE FRAME

Number of Nodes 143 Highest Node 143


Number of Elements 201 Highest Beam 201

Number of Basic Load Cases -2


Number of Combination Load Cases 9

Included in this printout are data for:


All The Whole Structure

Included in this printout are results for load cases:


Type L/C Name

Primary 11 STRUCTURAL DEAD LOADS


Primary 12 STRUCTURAL MISCELLANEOUS DEAD L
Primary 21 EQUIPMENT ERECTED LOAD
Primary 22 EQUIPMENT OPERATING LOAD
Primary 23 EQUIPMENT TEST LOAD
Primary 31 PIPING ERECTED LOAD
Primary 32 PIPING OPERATING LOAD
Primary 33 PIPING TEST LOAD
Primary 41 E&I ERECTED LOAD
Primary 51 LIVE LOADS
Primary 61 WIND LOAD DIR+X
Primary 62 WIND LOAD DIR+Z
Primary 71 SEISMIC LOADS DIR-X
Primary 72 SEISMIC LOADS DIR-Z
Primary 81 MONORAIL LOADS
Combination 101 OPERATION WITHOUT WIND
Combination 102 OPERATING WITH WIND DIR+X
Combination 103 OPERATING WITH WIND DIR+Z
Combination 104 TEST WITH WIND DIR+X
Combination 105 TEST WITH WIND DIR+Z
Combination 106 MAINTENANCE WITH WIND DIR+X
Combination 107 MAINTENANCE WITH WIND DIR+Z
Combination 108 EARTHQUAKE LOAD DIR+X
Combination 109 EARTHQUAKE LOAD DIR+Z

Print Time/Date: 24/02/2018 00:32 STAAD.Pro V8i (SELECTseries 5) 20.07.10.65 Print Run 1 of 2
Job No Sheet No Rev
P7531 2 A2

Part 1
Software licensed to
Job Title seawater filtration package Ref 1
By MEZ Date21-Feb-18 Chd NAS
Client TecnipFMC File seawater filter package_2 Date/Time 23-Feb-2018 21:49

PROPOSAL BRACING

Print Time/Date: 24/02/2018 00:32 STAAD.Pro V8i (SELECTseries 5) 20.07.10.65 Print Run 2 of 2

You might also like