SPECIFICATIONS AND FUNCTIONS
Measuring range: inside: 0-6" 0-150 mm depth: 0-6" 0-150 mm
outside: 0-6" 0-150 mm step: 0-6" 0-150 mm
Resolution: .0005" 0.01 mm
Accuracy: .001" 0.03 mm
Repeatability: .0005" 0.01 mm
Maximum measuring speed: > 60"/sec. - > 1.5 m/sec.
Measuring units: inch/metric, switch able (true conversion)
Measuring system: non-contacting linear SYLVAC measuring system (patented)
Display: LCD display, minus sign "-",5 digits with .185"/4.7 mm character height, small digit
"5" and "IN" sign for inch measuring unit
Power: one battery, 1.5 V., sylver oxyde (high drain), 190 mAh.
End of battery life warning by flashing display.
Battery life: 12 months of continuous use (reading constantly visible)
Operating temperature: 0° to + 40° C
Storage temperature: - 20° to + 70° C
Influence of humidity: not important within 0 to 80% of relative humidity
Data output: serial
Interface: RS 232
Jaws and body: hardened and ground stainless steel
Weight: 145 grams

NOTE: If the display does not operate correctly (display does not count or it is impossible
to reset to zero), remo e the battery (see page 6), wait 30 seconds and reinsert bat-
tery.
Do not use the digital caliper without its cap (on data output). This cap has to be
removed only in the event of the connection to an interface.

,-- __ Inside measuring jaws

r--- Positive locking screw


Step
measuring face

Wiper Scale

Depth
measuring blade
Zero setting
(zero setting at any position within the measuring range)
'------ INCH/METRIC change over
(true conversion)

Outside measuring jaws


SELECTION OF INCH OR METRIC READING
Close jaws, select inch or metric Example of metric reading Example of inch reading (last figure
mode, press zero button key no digit or small five)

INCH/Metric

ZERO SETTING AND MEASURING


While maintaining pressure on Move the jaw (3)
jaw (1) press button key for zero
display (2)

Outside measurements Inside measurements Step measurements


APPLICATIONS
Deviation from reference size (A reference size). Outside or inside measurement

Comparisons, e.g. between plug and hole

Measurement of wall thickness


APPLICATIONS
Measurement of center distance between two identical holes

MEASURING IN PLACES WHERE READING IS DIFFICULT


Set zero (3) while main-
taining pressure on jaw (2)

Close jaws (5). Read result while main-


taining pressure on jaw (disregard
minus sign)
CHANGING OF BATTERIES
2 screws

remove the 4 screws


remove the housing

2 screws

remove the battery and replace


y it
-I:DDO ~-;UU. • mount the housing
WARNING: sensitive contact
l ~(\
I~---da~-~ It
springs. Do not force the hous-

VJery
Contact springs
ing into position
locate first and than attach the
4 screws

Battery reference guide: 1.5 V., silver oxyde, high drain, 190 mAh.
UCAR 357
Ever-Ready 357 (UNION CARBIDE)
National WL 14
Seiko SB-B9
Mallory 0357 (10 L 14)
Bulova 228
Timex Typ J

IF owler 1 F_r_e_d_V_" _F_o_w_le_r_C_o---'",_I_"_c" _

CHICAGO BRANCH OFFICE: MAIN OFFICE LOS ANGELES BRANCH OFFICE:


825 N. Cass Ave., Suite 31 0 66 Rowe Street 5434 E. Washington Blvd.
Westmont, Illinois 60559 P.O. Box 48 Los Angeles, California 90040
(312) 325-5522 Newton, Massachusetts 02166 (213) 721-8883
(617) 332-7004
CABLE ADDRESS:
" Precision· Auburndale"
Telex 92 2435

You might also like