You are on page 1of 1

TOP PLAN VIEW

175
5-12MMØ MATTING
BARS SPCD.

850
1000
EQUALLY O.C.B.W.
6"THK PROPOSED RAILING L=179 M.
BEAM
CHB

600
250 175

88
150x250 BEAM WITH 12MMØ
200 200 200 MAIN BARS AND 10MMØ STIRRUPS

250
600 SPCD. SPCD. AT 200MM O.C.

SECTION ELEVATION VIEW


6" THK CHB WITH 10MMØ

H1=1650 ALONG STA. 0+010.00-0+079.50


H2=1400 ALONG STA. 0+079.50-0+169.00
H3=1050 ALONG STA. 0+169.00-0+179.00
150x250MM REINFORCED VERTICAL AND HORIZONTAL BARS
250

CONCRETE BEAM EVERY 3RD LAYER OF CHB

EXISTING RIPRAP WITH


PROPOSED ROUGH-IN WALL
PLASTERING

4-12MMØ
H1=1300 ALONG STA. 0+000.00-0+079.50
H2=1650 ALONG STA. 0+079.50-0+169.00
H3=1900 ALONG STA. 0+169.00-0+179.00

AREA CUT

VARIABLE:
VERTIVAL BARS W/
EXCAVATION
10MMØ STIRRUPS
SPCD. AT 2-50MM,
3-100MM,
4-150MM REST AT
200MM O.C.
VARIABLE:

750
6"THK CHB

100 150
750

ON-FILL 12MMØ R.S.B. SPCD.


@ 300MM O.C.B.W.
COARSE 250x200 COLUMN AT
AGGREGATES 600x600 FOOTING
200

5-12MMØ MATTING SPCD. EVERY 6.00 METERS


BARS SPCD. VARIABLE:
EQUALLY O.C.B.W. W1=1150 ALONG STA. 0+010.00-0+079.50
100

W2=1500 ALONG STA. 0+079.50-0+169.00


COARSE
W3=2800 ALONG STA. 0+169.00-0+179.00
200 200 200 AGGREGATES
600
CANAL TYPICAL DETAIL
COLUMN FOOTING DETAIL STA.0+010.00-0+179.50
SCALE: 1:15 MILLIMETERS SCALE: 1:15 MILLIMETERS

PREPARED BY: PROJECT NAME: CHECKED BY: APPROVED BY: SHEET NO.

V.M.JHEK BUILDERS
LICENSED CIVIL ENGINEER
REG. NO.: TIN NO.:
CONSTRUCTION OF DRAINAGE CANAL AT P-7 D
PTR. NO.: DATE: 24
CONTRACTOR ISSUED AT: LOCATION: BARANGAY TAGANITO, CLAVER, SURIGAO DEL NORTE