You are on page 1of 2

DATA SHEET

SB1020FCT~SB10100FCT

ISOLATION SCHOTTKY BARRIER RECTIFIERS


VOLTAGE- 20 to 100 Volts CURRENT - 10.0 Ampere ITO-220AB Unit: inch ( mm )

FEATURES

.100(2.55)
.112(2.85)
.406(10.3) MAX .189(4.8)MAX

.272(6.9)
.248(6.3)
.134(3.4)
.130(3.3)MAX
• Plastic package has Underwriters Laboratory .118(3.0)
Flammability Classification 94V-O.
Flame Retardant Epoxy Molding Compound.
• Exceeds environmental standards of

.606(15.4)
.583(14.8)
MIL-S-19500/228
• Low power loss, high efficiency.
• Low forwrd voltge, high current capability
• High surge capacity.
• For use in low voltage,high frequency inverters .114(2.9)
.071(1.8) MAX .098(2.5)
free wheeling , and polarlity protection applications.

.543(13.8)
.512(13.0)
.161(4.1) MAX
.055(1.4) MAX
.032(.8)
MAX
MECHANICAL DATA .035(.9) MAX

Case: ITO-220AB Molded plastic


.1 .1
Terminals: Solder plated, solderable per MIL-STD-202, Method 208 (2.55) (2.55)
Polarity: As marked. AC

+
Standard packaging: Any Positive CT

Weight: 0.08 ounces, 2.24grams. AC

MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS


Ratings at 25°C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%

SB1020FCT SB1030FCT SB1040FCT SB1050FCT SB1060FCT SB1080FCT SB10100FCT UNIT

Maximum Recurrent Peak Reverse Voltage 20.0 30.0 40.0 50.0 60.0 80.0 100.0 V

Maximum RMS Voltage 14.0 21.0 28.0 35.0 42.0 56.0 70.0 V

Maximum DC Blocking Voltage 20.0 30.0 40.0 50.0 60.0 80.0 100.0 V

Maximum Average Forward Rectified Current at Tc=90°C 10 A


Peak Forward Surge Current,
8.3 ms single half sine-wave 150 A
superimposed on rated load (JEDEC method)

Maximum Instantaneous Forward Voltage 0.85


0.55 0.75 V
at 5.0A per element

Maximum DC Reverse Current (Note 1) Ta=25°C 0.5


mA
at Rated DC Blocking Voltage Ta=100°C 50

Typical Thermal Resistance Note RθJA 60 °C/W

Operating and Storage Temperature Range TJ -50 to +125 °C

NOTES:

1. Thermal Resistance Junction to Ambient .

DATE : OCT.15.2002 PAGE . 1


RATING AND CHARACTERISTIC CURVES
50,60V
40

INSTANTANEOUS FORWARD CURRENT


20,30,40V

25.0
AVERAGE FORWARD CURRENT

10 80,100V
8
6
20.0
4

AMPERES
15.0 2

1.0
10.0 .8
.6
.4 O
5.0 TJ = 25 C
.2 Pulse Width = 300ms
1% Duty Cycle
0
0 .1
50 100 150
.4 .5 .6 .7 .8 .9 1.0 1.1
O
CASE TEMPERATURE, C INSTANTANEOUS FORWARD VOLTAGE, VOLTS

Fig.1- FORWARD CURRENT DERATING CURVE Fig.2- TYPICAL INSTANTANEOUS FORWARD


CHARACTERISTIC
INSTANTANEOUS REVERSE CURRENT, MILAMPERES

100
TC = 100OC
150
PEAK FORWARD SURGE CURRENT,

10 120
8.3ms Single
Half Since-Wave
O 110 JEDEC Method
TC = 75 C
90
1.0
70
TC = 25OC
50

0.1 30

20

10
0.01 1 2 5 10 20 50 100
0 100 200 300 NO. OF CYCLE AT 60HZ
PERCENT OF PEAK REVERSE VOLTAGE
Fig.3- TYPICAL REVERSE CHARACTERISTIC Fig.4- MAXIMUM NON-REPETITIVE SURGE CURRENT

400

350
CAPACITANCE, pF

O
TJ = 25 C
300

250

200

150

0
1 2 5 10 20 50 100 200 500

REVERSE VOLTAGE, VOLTS

Fig.5- TYPICAL JUNCTION CAPACITANCE

DATE : OCT.15.2002 PAGE . 2