ULS Load Factors for NZTA Bridge Manual from table 3.2.

locked in force due to

overload with impact


normal live load with

centrifugal efects of

prestress shortening
temperature efect -
foodwater pressure

shrinkage and creep


horizontal efects of
Constructon loads
Dead load + SDL

pedestrian load

and secondary
ordinary water
earth pressure

water ponding

collision loads
impact factor

ground water
constructon

trafc loads

trafc loads

overall and
diferental
setlement

with scour

snow load
wind load
sequence

pressure

seismic

efects
factor
DL CN EL LLxI OLxI FP HE CF EP GW ST OW FW PW EQ WD SN CO TP SG PS
1A(max) 1.35 1.35 2.25 1.76 2.25 1.82 1 1.35 1.35 1.35 1
1A(min) 1 1 2.25 1.76 2.25 1.35 1 1 1.35 1 1
Primary 1B(max) 1.35 1.35 1.82 1 1.35 1.35 1.69 1.35 1
trafc 1B(min) 1 1 1.35 1 1 1.35 1.69 1 1
2A(max) 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1 1.2 1.2 1.2 1.2 1
2A(min) 1 1 1.2 1.2 1.2 1.2 1 1 1 1.2 1.2 1 1
2B(max) 1.35 1.35 1.35 1.35 1.35 1.35 1.35 1 1.35 1.35 1 1.35 1
2B(min) 1 1 1.35 1.35 1.35 1.35 1 1 1 1.35 1 1 1
Secondary
normal 2C(max) 1.35 1.35 1.35 1.35 1.35 1.35 1.35 1 1.35 1 1 1.35 1
trafc cases 2C(min) 1 1 1.35 1.35 1.35 1.35 1 1 1 1 1 1 1
3A 1 1 1.35 1 1 1.35 1 0.33 1 1
3B(max) 1.1 1.1 1.38 1 1.1 1 1 1.1 1
3B(min) 1 1 1.25 1 1 1 1 1 1
3C 1 1 1.35 1 1 1.35 1.5 0.33 1 1
Primary
lateral load 3D(max) 1.2 1.2 1.2 1 1.2 1.2 1 0.33 1 1.2 1.2 1
cases 3D(min) 1 1 1 1 1 1.2 1 0.33 1 1.2 1 1
trafc 4A(max) 1.35 1.35 1.49 0.95 1.49 1.35 1 1.35 1.35 0.45 1.35 1
overload 4A(min) 1 1 1.49 0.95 1.49 1 1 1 1.35 0.45 1 1
Load Case (M Hog, M Sag, Vmax) Msag SAGGING MOMENT
Loads 6212 5562 0 1271 0
Factored Loads
Load Combinaton DL CN EL LLxI OLxI FP HE CF EP GW ST OW FW PW EQ WD SN CO TP SG PS total
1A(max) 8386 0 0 12514 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 20901
1A(min) 6212 0 0 12514 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18726
Primary 1B(max) 8386 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2147 0 0 10533
trafc 1B(min) 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2147 0 0 8359
2A(max) 7454 0 0 6674 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1525 0 0 15653
2A(min) 6212 0 0 6674 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1525 0 0 14411
2B(max) 8386 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 15895
2B(min) 6212 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13721
Secondary
normal 2C(max) 8386 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 15895
trafc cases 2C(min) 6212 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13721
3A 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 419 0 0 6631
3B(max) 6833 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6833
3B(min) 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6212
3C 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 419 0 0 6631
Primary
lateral load 3D(max) 7454 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1525 0 0 8979
cases 3D(min) 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1525 0 0 7737
trafc 4A(max) 8386 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 572 0 0 8958
overload 4A(min) 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 572 0 0 6784

ULS DL on girder only 5482 max 20901


Mhog ULS DL on composite secton 2904 min 6212
Msag
Vmax

file:///conversion/tmp/scratch/382911295.xlsx ULS 03/30/2018


382911295.xlsx
ULS Load Factors for NZTA Bridge Manual from table 3.2.1

locked in force due to

overload with impact


normal live load with

centrifugal efects of

prestress shortening
temperature efect -
foodwater pressure

shrinkage and creep


horizontal efects of
Constructon loads
Dead load + SDL

pedestrian load

and secondary
ordinary water
earth pressure

water ponding

collision loads
impact factor

ground water
constructon

trafc loads

trafc loads

overall and
diferental
setlement

with scour

snow load
wind load
sequence

pressure

seismic

efects
factor
DL CN EL LLxI OLxI FP HE CF EP GW ST OW FW PW EQ WD SN CO TP SG PS
1A(max) 1 0 1 1.35 0 1 0 1 1 1 1 1 0 0 0 0 0 0 0 1 1
1A(min) 1 0 1 1.35 0 1 0 1 1 1 1 1 0 0 0 0 0 0 0 1 1
Primary 1B(max) 1 0 1 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1
trafc 1B(min) 1 0 1 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1
2A(max) 1 0 1 1.35 0 1 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1
2A(min) 1 0 1 1.35 0 1 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1
2B(max) 1 0 1 1.35 0 1 1 1 1 1 1 1 0 0 0 1 0 0 0 1 1
2B(min) 1 0 1 1.35 0 1 1 1 1 1 1 1 0 0 0 1 0 0 0 1 1
Secondary
normal 2C(max) 1 0 1 1.35 0 1 1 1 1 1 1 0 1 1 0 0 0 0 0 1 1
trafc cases 2C(min) 1 0 1 1.35 0 1 1 1 1 1 1 0 1 1 0 0 0 0 0 1 1
3A 1 0 1 0 0 0 0 0 1 1 1 1 0 0 1 0 0 0 1 0.33 1
3B(max) 1 0 1 0 0 0 0 0 1 1 1 0 0 1 0 1 0 0 0 1 1
3B(min) 1 0 1 0 0 0 0 0 1 1 1 0 0 1 0 1 0 0 0 1 1
3C 1 0 1 0 0 0 0 0 1 1 1 1 0 0 0 0 0 1 1 0.33 1
Primary
lateral load
cases
trafc 4A(max) 1 0 1 0 1 0.5 0 1 1 1 1 1 0 0 0 0 0 0 1 1 1
overload 4A(min) 1 0 1 0 1 0.5 0 1 1 1 1 1 0 0 0 0 0 0 1 1 1
Msag SAGGING MOMENT
Loads 6212 0 0 5562 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1271 0 0
Factored Loads
Load Combinaton DL CN EL LLxI OLxI FP HE CF EP GW ST OW FW PW EQ WD SN CO TP SG PS total
1A(max) 6212 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13721
1A(min) 6212 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13721
Primary 1B(max) 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1271 0 0 7483
trafc 1B(min) 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1271 0 0 7483
2A(max) 6212 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1271 0 0 14991
2A(min) 6212 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1271 0 0 14991
2B(max) 6212 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13721
2B(min) 6212 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13721
Secondary
normal 2C(max) 6212 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13721
trafc cases 2C(min) 6212 0 0 7509 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13721
3A 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1271 0 0 7483
3B(max) 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6212
3B(min) 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6212
3C 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1271 0 0 7483
Primary
lateral load
cases
trafc 4A(max) 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1271 0 0 7483
overload 4A(min) 6212 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1271 0 0 7483

max 14991
min 6212

file:///conversion/tmp/scratch/382911295.xlsx SLS 03/30/2018


382911295.xlsx
M Hog M Sag Vmax
10 kN/m UDL -1531 857 218

DL 47 kN/m -7255 4061 1033


SDL 25 kN/m -3843 2151 547
barrier (included in SDL) 0 0 0
Total Dead load -11098 6212 1580

HN UDL (1 lane) -1608 1222 230


HN axle (1 lane) -790 1452 220
Total Live load -2398 2674 450
Equivalent no of lanes 1.6 1.6 1.6
Impact factor 1.3 1.3 1.3
Final Live load including impact -4988 5562 936

Dif temp -648 1271


Dif shrinkage -3701 0

equivalent no of lanes is from 2D spacegass model with crossbeam


going to rigid supports
Demands on Girder
Span 35 m
Steel Girder Depth 2050 mm
Tributary Width 6.0 m
Girder Area 0.0909 m2
Girder SW 7.1 kN/m
crossbeam length 9m
crossbeam weight 1.1 kN/m
crossbeam spacing 3.6 m
equivalent UDL longitudinally 3 kN/m

Slab max thickness 0.25 m


slab UDL 38 kN/m

Total Girder DL UDL 47 kN/m

Footpath Deck
thickness 0m
width 0m
Footpath UDL 0 kN/m
Barrier Width 1.00 m if barrier is located on this girder
Barrier Load 15 kN/m (1.5 barriers)

Surfacing 10 kN/m (1.5 kpa+levelling of 50mm)


Services 0.1 kN/m

Total SDL UDL 25 kN/m

Total permanent UDL 72 kN/m


Pier section b tw
top flange 600 50
web 1950 20
bot flange 750 50
area 106500
length of section 15

Midspan b tw
top flange 600 30
web 1950 16
bot flange 600 50
area 79200
length of section 20

Average area 90900


Stiffened web shear capacity

dp 2100 mm
tw 20 mm
fy 350 Mpa

spacing between stfeners s = 4000 mm


s/dp = 1.9 Stfened web
dp/tw = 105
dp/tw x (Fy/250)0.5 = 124
Vb = av.ad.af.Vw
av = 0.53
ad = 1.36
af = 1 use 1.0
Vb 6328 kN
fVb = 5695 kN

You might also like