dseGenset

dse8810
ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY
BS EN 61000-6-2
COLOUR AUTO START LOAD SHARE MODULE EMC Generic Immunity Standard for
the Industrial Environment
BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
FEATURES ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment

The DSE8810 is an easy-to-use, The event log will record 250 events to KEY LOAD SHARE FEATURES: TEMPERATURE
loadshare module, designed to facilitate easy maintenance. An • Sequential set start BS EN 60068-2-1
Ab/Ae Cold Test -30 oC
synchronise and work within a extensive number of fixed and • R.O.C.O.F. and vector shift BS EN 60068-2-2
loadshare system of up to 32 flexible monitoring, metering and • Generator load demand Bb/Be Dry Heat +70 oC
generators including electronic and protection features are included • Automatic hours run balancing VIBRATION
non-electronic engines. as well as comprehensive • Dead bus sensing BS EN 60068-2-6
communication and system • Bus failure detection Ten sweeps in each of three
major axes
The DSE8810 monitors the generator expansion options. • Direct governor and AVR control 5 Hz to 8 Hz @ +/-7.5 mm,
and indicates operational status and • Volts and frequency matching 8 Hz to 500 Hz @ 2 gn
fault conditions, automatically Using the DSE PC Configuration • kW and kV Ar load sharing HUMIDITY
starting or stopping the engine on Suite Software allows easy alteration BS EN 60068-2-30
load demand or fault condition. of the operational sequences, timers Db Damp Heat Cyclic 20/55 oC
@ 95% RH 48 Hours
and alarms. With all communication BS EN 60068-2-78
System alarms are annunciated on ports capable of being active at the Cab Damp Heat Static 40 oC
@ 93% RH 48 Hours
the LCD screen (multiple language same time, the DSE8810 is ideal for a
options available), illuminated LED wide variety of demanding load share SHOCK
and audible sounder. applications. BS EN 60068-2-27
Three shocks in each of three major axes
15 gn in 11 mS

DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
BS EN 60529
COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY IP65 - Front of module when installed into the
control panel with the supplied sealing gasket.
OF LOAD SHARE APPLICATIONS
DSE2130 MODEM MODBUS PC
DSE2131
DSE2133
DSE2152 2 11 6 4
DSE2157
DSE2548 232 485

DSENET ®
RS232 AND USB USB CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER
EXPANSION RS485 PORT HOST INPUTS SENDERS STOP SUPPLY 8-35V
+
ETHERNET

DEUTZ
DSE8810 MSC
ISUZU
PERKINS
CATERPILLAR
7
MTU
8x60 ­8x10 ­8x80 ­8x10 ­8x60 VOLVO
OTHER CUMMINS
SCANIA

BUS VOLT FREE GENERATOR SENSING FUEL & CRANK CHARGE ELECTRONIC MAGNETIC
SENSING OUTPUTS OUTPUTS ALTERNATOR ENGINES PICK-UP
FLEXIBLE WITH CAN

CURRENT VOLTS
D­+
+ W/L

1ph 2 1ph 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N NE N

ISSUE 1
®

dseGenset

dse8810
SPECIFICATION

DC SUPPLY
CONTINUOUS VOLTAGE RATING
COLOUR AUTO START LOAD SHARE MODULE 8 V to 35 V continuous

CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
supply recovers to 5 V. This is achieved
FEATURES without the need for internal batteries

MAXIMUM OPERATING CURRENT


600 mA at 12 V, 300 mA at 24 V

MAXIMUM STANDBY CURRENT


330 mA at 12 V, 160 mA at 24 V

CHARGE FAIL/EXCITATION RANGE


0 V to 35 V

OUTPUTS
OUTPUT A (FUEL)
15 A DC at supply voltage

OUTPUT B (CRANK)
15 A DC at supply voltage

OUTPUTS C & D
8 A AC at 250 V AC (Volt free)

AUXILIARY OUTPUTS E TO J
2 A DC at supply voltage

GENERATOR & BUS


VOLTAGE RANGE
15 V to 333 V AC (L-N)

FREQUENCY RANGE
3.5 Hz to 75 Hz

KEY FEATURES • Configurable event log (250) with modem diagnostics MAGNETIC PICK-UP
VOLTAGE RANGE
• Configurable inputs (11) • Easy access diagnostic page • DSENet® expansion compatible +/- 0.5 V to 70 V
• Configurable outputs (8) • CAN and Magnetic Pick-up/Alt. • Integral PLC editor
FREQUENCY RANGE
• Built-in governor and AVR control sensing 10,000 Hz (max)
• Comprehensive electrical • Fuel usage monitor and low fuel KEY BENEFITS
BUILT-IN GOVERNOR CONTROL
protection alarms • Dual processor for improved MINIMUM LOAD IMPEDANCE
• Comprehensive loadshare • Manual fuel pump control response 1000Ω
Fully isolated
capabilities • “Protections disabled” feature • RS232, RS485 & Ethernet can be
• RS232, RS485 & Ethernet remote • kW overload protection used at the same time GAIN VOLTAGE
communications • Reverse power protection • High number of inputs and 0 V to 10 V DC
Fully isolated
• Modbus RTU/TCP support • Power monitoring (kW h, kV Ar, kV outputs
• Back-lit LCD graphical display A h, kV Ar h) • Worldwide language support OFFSET VOLTAGE
+/- 10 V DC
• Configurable display languages • Load switching (load shedding • Data logging & trending Fully isolated
• Audible alarm and dummy load outputs) • Harmonics display for clear
BUILT-IN AVR CONTROL
• Reduced file transfer time • Unbalanced load protection monitoring* MINIMUM LOAD IMPEDANCE
• Engine protection • Independent Earth Fault trip • Modules can be integrated into 1000Ω
Fully isolated
• Fault condition notification to • USB connectivity building management systems
a designated PC • Backed up real time clock (BMS) GAIN VOLTAGE
0 V to 10 V DC
• Compatible with DSE8700 & • Fully configurable via DSE • Licence-free PC software Fully isolated
DSE8600 Series Configuration Suite PC software • IP65 rating (with supplied gasket)
OFFSET VOLTAGE
• Front panel editing with PIN • Advanced SMS messaging offers increased resistance to +/- 10 V DC
protection (additional external modem water ingress Fully isolated
• Flexible sender inputs required) • PLC editor allows user DIMENSIONS
• Configurable timers and alarms • Start & stop capability via SMS configurable functions to meet OVERALL
245 mm x 184 mm x 50 mm
• 3 configurable maintenance alarms messaging specific application requirements 9.6” x 7.2” x 2”
• Multiple date and time scheduler • Additional display screens to help *Available soon
PANEL CUTOUT
220 mm x 160 mm
8.7” x 6.3”
RELATED MATERIALS
MAXIMUM PANEL THICKNESS
TITLE PART NO’S 8 mm
DSE8810 Installation Instructions 053-137 0.3”
DSE88xx Operator Manual 057-163
STORAGE TEMPERATURE RANGE
DSE88xx PC Configuration Suite Manual 057-164 -40 oC to +85 oC

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-116/03/12 (1) US
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457