Professional Documents
Culture Documents
Section J Issue 2
Alternatives: Ø Construction:
Please ask for details Conductor Bare copper (1x1,12) 1,12
Dielectric Foamed PE 2,95
Tape
Braid
Jacket
Aluminium / mylar (bonded to dielectric)
Tin plated copper
HFS 80 T, Black
3,07
3,70
4,95
1
Weight 35 kg/km
Temperature rating (°C) -25 / +80°C
Order reference 33000-300-00
2
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
80 pF/m
MHz
50
dB/100m
8
6
Velocity of signal propagation 83 % 100 11
Signal delay 4 ns/m 200 15
Working voltage, AC r.m.s. 500 max 400 22
Working voltage, DC
Attenuation, typical values
1000 max
see table
900
1500
33
43
7
(nominal values at an air temperature of +20°C) 1800 47
Power, typical values see table 2000 50
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 56
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
typically -90 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 13mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 50mm
passes IEC 60332-3-24
50
100
1020
550
9
Flammability passes UL 94 V-0 200 385
Halogen free passes IEC 60754-2 400 275
Smoke generation
Connectors
passes IEC 61034-2
Information can be provided on request
900
1500
1800
180
140
130
10
2000 120
2500 100
11
12
Ref: SF-eSF300-02
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2007-04-08
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Please ask for details Conductor Bare copper (1x1,42) 1,42
Dielectric Foamed PE 3,81
Tape
Braid
Jacket
Aluminium / mylar (bonded to dielectric)
Tin plated copper
HFS 80 T, Black
3,90
4,50
6,10
1
Weight 59 kg/km
Temperature rating (°C) -25 / +80°C
Order reference 33000-400-00
2
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
79 pF/m
MHz
50
dB/100m
6
6
Velocity of signal propagation 84 % 100 8
Signal delay 4 ns/m 200 12
Working voltage, AC r.m.s. 500 max 400 17
Working voltage, DC
Attenuation, typical values
1000 max
see table
900
1500
25
33
7
(nominal values at an air temperature of +20°C) 1800 36
Power, typical values see table 2000 38
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 43
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
typically -90 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 20mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 60mm
passes IEC 60332-3-24
50
100
1150
800
9
Flammability passes UL 94 V-0 200 565
Halogen free passes IEC 60754-2 400 400
Smoke generation
Connectors
passes IEC 61034-2
Information can be provided on request
900
1500
1800
260
200
180
10
2000 170
2500 150
11
12
Ref: SF-eSF400-02
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2007-04-08
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Please ask for details Conductor Bare copper (1x1,78) 1,78
Dielectric Foamed PE 4,80
Tape
Braid
Jacket
Aluminium / mylar (bonded to dielectric)
Tin plated copper
HFS 80 T, Black
5,00
5,70
7,60
1
Weight 94 kg/km
Temperature rating (°C) -25 / +80°C
Order reference 33000-500-00
2
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
79 pF/m
MHz
50
dB/100m
5
6
Velocity of signal propagation 85 % 100 7
Signal delay 4 ns/m 200 10
Working voltage, AC r.m.s. 500 max 400 14
Working voltage, DC
Attenuation, typical values
1000 max
see table
900
1500
22
28
7
(nominal values at an air temperature of +20°C) 1800 31
Power, typical values see table 2000 32
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 37
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
typically -90 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 23mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 75mm
passes IEC 60332-3-24
50
100
1600
1125
9
Flammability passes UL 94 V-0 200 795
Halogen free passes IEC 60754-2 400 550
Smoke generation
Connectors
passes IEC 61034-2
Information can be provided on request
900
1500
1800
360
280
250
10
2000 240
2500 210
11
12
Ref: SF-eSF500-02
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2007-04-08
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Please ask for details Conductor Copper covered aluminium (1x2,77) 2,77
Dielectric Foamed PE 7,24
Tape
Braid
Jacket
Aluminium / mylar (bonded to dielectric)
Tin plated copper
HFS 80 T, Black
7,40
8,13
10,3
1
Weight 121 kg/km
Temperature rating (°C) -25 / +80°C
Order reference 33000-700-00
2
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
79 pF/m
MHz
50
dB/100m
3
6
Velocity of signal propagation 84 % 100 4
Signal delay 4 ns/m 200 6
Working voltage, AC r.m.s. 500 max 400 9
Working voltage, DC
Attenuation, typical values
1000 max
see table
900
1500
13
17
7
(nominal values at an air temperature of +20°C) 1800 19
Power, typical values see table 2000 20
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 23
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
typically -90 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 25mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 100mm
passes IEC 60332-3-24
50
100
2600
1835
9
Flammability passes UL 94 V-0 200 1255
Halogen free passes IEC 60754-2 400 880
Smoke generation
Connectors
passes IEC 61034-2
Information can be provided on request
900
1500
1800
580
440
400
10
2000 370
2500 330
11
12
Ref: SF-eSF700-02
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2007-04-08
publication and is subject to change without prior notice. Approved by:
Alternatives: Construction:
Please ask for details Conductor Copper covered aluminium (1x3,61) 3,61
Dielectric Foamed PE 9,40
Tape
Braid
Jacket
Aluminium / polyester (bonded to dielectric)
Tin plated copper
HFS 80 T, Black
9,55
10,3
12,7
1
Weight 150 kg/km
Temperature rating (°C) -25 / +80°C
Order reference 33000-900-00
2
3
Notes:
All dimensions nominal (± 4%)
unless otherwise stated.
All dimensions in mm.
4
5
Electrical: Attenuation
Impedance
Capacitance
50 ± 2 Ohms
79 pF/m
MHz
50
dB/100m
3
6
Velocity of signal propagation 85 % 100 4
Signal delay 4 ns/m 200 5
Working voltage, AC r.m.s. 500 max 400 7
Working voltage, DC
Attenuation, typical values
1000 max
see table
900
1500
11
14
7
(nominal values at an air temperature of +20°C) 1800 15
Power, typical values see table 2000 16
(ambient temperature of 40°C at sea level and VSWR 1.0) 2500 18
Suitable for frequencies
Shielding effectiveness
up to 2,5 GHz
typically -90 dB/m
8
Environmental & Mechanical: Average Power
Minimum bend radius (MBR) single bend (installation) single bend: 32mm MHz W
Minimum bend radius (MBR) dynamic use
Flame resistance
multiple bends: 130mm
passes IEC 60332-3-24
50
100
3400
2325
9
Flammability passes UL 94 V-0 200 1675
Halogen free passes IEC 60754-2 400 1165
Smoke generation
Connectors
passes IEC 61034-2
Information can be provided on request
900
1500
1800
750
570
520
10
2000 490
2500 430
11
12
Ref: SF-eSF900-02
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of Date: 2007-04-08
publication and is subject to change without prior notice. Approved by: