You are on page 1of 2

GPS TIME SYNCHRONIZATION EQUIPMENT

SYNTIME

Features Applications
n
GPS Time and Frequency reference n
SCADA
n
Built in NCO. Provides additional redundancy using OCXO or TCXO n
Energy Management System
n
2048 KHz, E1 output for communication Networks n
Dynamic Demand Management System
n
Time signals in IRIG B/E, RS-232, MODBUS (RS-485) n
Energy Meters - HT Consumers & Feeders
n
10 / 100 MBPS NTP / SNTP output n
ABT / Boundary meters
n
Sleek and small 1U footprint n
Disturbance Recorders
n
Isolated and protected interfaces n
Event Loggers
n
Fibre Optic outputs n
Load Dispatch Centre
n
Large size Remote Display Unit
n
SNMP output for remote monitoring

Technical Specifications: Syntime


Antenna Computer Interface
nConfiguration : Single (Standard) nRS-232 : 2 Nos front panel (optional)
: Dual redundant (Optional) nUSB : 2 Nos front panel (optional)
nAntenna Type : Active
nGain : 35±3 dB
nCoverage : 360º Azimuth: 0 to 90º Elevation
Pulse Signals
nPulse Per Second : 1 x 250 V, 0.2 A, SPST-
nOperating temp : -40 to +85ºC
: PFC Solid state relay
nEnvironmental : All weather water proof : 1x Isolated TTL
nAccuracy : < 100 ns rms
nPulse width : 2 50 m S ± 2 0 m S
GPS Receiver (100 mS to 250 mS)
nConfiguration : Single (Standard) nPulse out puts : 4-PPS, PPM, PPHH, PPH and PPD
: Dual redundant (Optional) (all 4 ports can be field configured
nOutputs : PPS, Time, Position & Frequency for any pulse)
nSatellite Tracking nConnector : Euroterminal, Twistedpair
: 12 Channels, C/A code
n
Acquisition Time : Cold < 45s
: Warm < 38s Time Code Signals
: Hot < 5s nIRIGB : AM & PWM
: Re acquisition <0.5s nConnector : 75E coax for both
(IRIG E instead of IRIG B Optional)
External Clock input (Optional)
nFrequency : 1- 20MHz (Factory set) Serial Time signals
: Coax 75E nModbus on RS-485 : 1 x Broadcast mode
nE1 clock : 2048 KHz, HDB3 coding nConnector : Euroterminal or DB9
nContent : Time, position, status (customisable)
: Coax 75E or TP-120E
(RS-232 instead of RS-485-optional)
nEthernet Port : 2 x 10/100Mbps
Event Input nConnector : RJ45
nProtocol : NTP / SNTP (SNMP optional)
nExternal : Isolated, TTL/ 5V CMOS
nConnector : Euro terminal, two wire

User Interface
n
LCD Display : 20 x 2 Alphanumeric
n
Status LEDs : 4- GPS, NTP, RTC, Power
n
Keys : 3-Up, Down and Enter
n
Alarm contacts : SPST- 125 VAC, 0.3A

ISO 9001:2008 Certified Company

www.sandsindia.com
Front View

Rear View

Optical Ports ( Optional) Compliance


No of Ports
n : 1 x Pulse, 1 x IRIGB PWM Safety
n : IEC 60950
Type
n : IR LED 820 nm ESD
n : IEC 61000-4-2,Contact ±4KV
Connector
n : SC / ST simplex : (Lvl 2); Air ± 8KV(Lvl 3)
Fiber
n : 62.5/125um, Graded Radiated Immunity : IEC 61000-4-3; 3V/m,
n
Range
n : up to 1500mtrs : 80 MHz to 1000 MHz. (Lvl 2)
Radiated Emission:
n EN55022 Class A
EFT
n : IEC 61000-4-4; 1KV (Lvl 2)
Cold
n : IEC 60068-2-1; -25±3°C, 72Hrs
Mechanical Dry Heat
n : IEC 60068-2-2; +70 ±2°C, 72 Hrs
Enclosure
n : 1U, 19” rack mountable Shock Test
n : IEC 60255-21-2;
: Rear entry, customizable back panel : 30g, Half sine,11ms-3 x 6 Shocks
Size
n : 44 H x 443 W x 270 D mm Damp heat
n : IEC 60068-2-30;+40±2°C, 2cycles
Weight
n : 5Kg (Max) (48Hrs-Off Condition)
compliance
n : IP20 Vibration
n : IEC60068-2-6 ; 10-150-10 Sweep,
: 4 mm P to P/2.2g, 1 octave/min,1hr
: Each in 3 axis and both directions
Standard Accessories:
Power Supply Antenna
n
Standard
n : AC 90 to 260V, 47-63Hz or DC 130V to 370V Mounting assy : 1 for each antenna
Custom
n : 110V DC, 48V DC, 24V DC or any other Power Cord
n : 1(2mts)
(Custom requirements need to be confirmed) Mating connectors
n : 1 set
Power
n : < 30 W Software
n : 1 CD
nDocuments : User manual, test reports
(Cables and connectors extra as per installation requirements)

BCS Software Optional Accessories


Configuration
n Remote Receiver
n

Software : Windows based IRIG B AM Hub


n
IRIG B PWM Hub
n
RS-485 Hub
n
RS-485 to RS-232 converter
n

300 mm Display
DS
SAN

Remote
Display Unit

100 mm Display
S
ND
SA

REMOTE DISPLAY UNIT

HO.: 15/D-19, SIPCOT IT Park, Siruseri, Chennai, Tamilnadu - 603 103. Ph.: 044 - 27470001, 27470002
27470003, 27470087, 27470088. Telefax: 044 - 27470002, e-mail: sands@sandsindia.com,
UNIT Delhi: T-74 B, Ground Floor, Krishna Mandir Lane, Khirki Extn, Malaviya Nagar, New Delhi - 110 017.
Ph: 011-29542914, Telefax: 011-29542842. e-mail: sandsdelhi@sandsindia.com
Product developement is continuous process - Specification subject to change
EDITION : 03-14’
www.sandsindia.com

You might also like